Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Code does not work for cicularly polarized pulses #8

Open
jonyanjiang opened this issue Oct 18, 2019 · 5 comments
Open

Code does not work for cicularly polarized pulses #8

jonyanjiang opened this issue Oct 18, 2019 · 5 comments
Assignees
Labels

Comments

@jonyanjiang
Copy link

Dear developers, I find maybe a bug.
When I use the code to run only two cicularly polarized lasers, it works ok.
But when plasma added, it breaks out, after laser reaching the surface of plasma.
I used the 1.5.2 version.
Can you help me to solve this? Thanks.
Here is the result and the main file.
circularhhgB_FIELD_000000bin000txt
circularhhgB_FIELD_010000bin000txt
main-piccante.txt

@cenit cenit self-assigned this Oct 18, 2019
@cenit cenit added the bug label Oct 18, 2019
@cenit
Copy link
Member

cenit commented Oct 18, 2019

Thanks for your report. I will investigate it as soon as possible

@sgatto
Copy link
Member

sgatto commented Apr 27, 2020

@cenit , did you reproduce the issue?

@sgatto
Copy link
Member

sgatto commented Apr 27, 2020

@jonyanjiang , can you provide the input file of your simulation?

@cenit
Copy link
Member

cenit commented Apr 27, 2020

@sgatto no, at least not without an input file or a custom main cpp file.

@jonyanjiang
Copy link
Author

@sgatto The input file is attached at the end line of the original issue statement. I changed its suffix from .cpp to .txt to meet the github requirement for attached files.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Projects
None yet
Development

No branches or pull requests

3 participants