You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I am experiencing a problem while flying with two AR drones. Sometimes the ultrasound sensor is sending incorrect values. I am controlling each drone with one separate PC. As suggested in issue #193 I tried changing the ultrasound_freq to 7 for one drone and to 8 for the other one. I am using this launch file. In one config the parameter ultrasound_freq ist set like this <param name="ultrasound_freq" value="8" /> and in the other one it is set to 7.
The problem that I am experiencing is that even though I am setting these values in my launch file they are not correctly set in data/config.ini of the AR drone. Whenever I try to set them to 8 the config.ini still reads 7. When I now edit the config.ini file and set ultrasound_freq = 8 manually, then start roslaunch again, the value will be overwritten to 7 while it should remain at 8.
The weird thing is that if I set my ultrasound_freq to 9 in my launch file and then start it, it will get overwritten in the config.ini and then reads ultrasound_freq = 9. When I change my launch file back to 8 again and then run it, the config still reads 9. It seems that all values are accepted except for 8. I even tried the example configs where ultrasound_freq is set to 8 but the config.ini still reads ultrasound_freq = 7.
The output when running roslaunch start.launch
$ roslaunch start.launch
... logging to /home/void/.ros/log/ad0ddd28-86d8-11e8-83c6-955de12afcbf/roslaunch-void-2627.log
Checking log directory for disk usage. This may take awhile.
Press Ctrl-C to interrupt
Done checking log file disk usage. Usage is <1GB.
started roslaunch server http://void:46855/
SUMMARY
========
CLEAR PARAMETERS
* /ardrone_autonomy/
PARAMETERS
* /ardrone_autonomy/altitude_max: 1500
* /ardrone_autonomy/altitude_min: 50
* /ardrone_autonomy/bitrate: 4000
* /ardrone_autonomy/control_vz_max: 2000
* /ardrone_autonomy/control_yaw: 1.75
* /ardrone_autonomy/cov/imu_av: [1.0, 0.0, 0.0, 0...
* /ardrone_autonomy/cov/imu_la: [0.1, 0.0, 0.0, 0...
* /ardrone_autonomy/cov/imu_or: [1.0, 0.0, 0.0, 0...
* /ardrone_autonomy/euler_angle_max: 0.18
* /ardrone_autonomy/looprate: 200
* /ardrone_autonomy/max_bitrate: 4000
* /ardrone_autonomy/navdata_demo: 0
* /ardrone_autonomy/realtime_navdata: False
* /ardrone_autonomy/realtime_video: True
* /ardrone_autonomy/ultrasound_freq: 8
* /rosdistro: kinetic
* /rosversion: 1.12.13
NODES
/
ar_track_alvar_bottom (ar_track_alvar/findMarkerBundlesNoKinect)
ar_track_alvar_front (ar_track_alvar/findMarkerBundlesNoKinect)
ardrone_autonomy (ardrone_autonomy/ardrone_driver)
auto-starting new master
process[master]: started with pid [2640]
ROS_MASTER_URI=http://localhost:11311
The text was updated successfully, but these errors were encountered:
I am experiencing a problem while flying with two AR drones. Sometimes the ultrasound sensor is sending incorrect values. I am controlling each drone with one separate PC. As suggested in issue #193 I tried changing the
ultrasound_freq
to 7 for one drone and to 8 for the other one. I am using this launch file. In one config the parameter ultrasound_freq ist set like this<param name="ultrasound_freq" value="8" />
and in the other one it is set to 7.The problem that I am experiencing is that even though I am setting these values in my launch file they are not correctly set in
data/config.ini
of the AR drone. Whenever I try to set them to 8 the config.ini still reads 7. When I now edit the config.ini file and setultrasound_freq = 8
manually, then start roslaunch again, the value will be overwritten to 7 while it should remain at 8.The weird thing is that if I set my ultrasound_freq to 9 in my launch file and then start it, it will get overwritten in the config.ini and then reads
ultrasound_freq = 9
. When I change my launch file back to 8 again and then run it, the config still reads 9. It seems that all values are accepted except for 8. I even tried the example configs where ultrasound_freq is set to 8 but the config.ini still readsultrasound_freq = 7
.The output when running
roslaunch start.launch
The text was updated successfully, but these errors were encountered: