diff --git a/src/pynxtools_xps/nomad/examples/eln_data.yaml b/src/pynxtools_xps/nomad/examples/eln_data.yaml deleted file mode 100644 index a5f75ea..0000000 --- a/src/pynxtools_xps/nomad/examples/eln_data.yaml +++ /dev/null @@ -1,159 +0,0 @@ -title: EX439_S718_Au in 25 mbar O2 -start_time: 2022-04-08T11:47:02.0200Z -end_time: 2022-04-08T14:52:26.0400Z -entry_identifier: EX439 -experiment_institution: Max Planck Institute for Chemical Energy Conversion -experiment_facility: Surface and Interface Analysis Group -experiment_laboratory: Near-Ambient Pressure XPS Lab -program_name: SpecsLabProdigy -user: - name: Lukas Pielsticker - affiliation: Max Planck Institute for Chemical Energy Conversion - address: Lukas Pielsticker - email: lukas.pielsticker@cec.mpg.de - orcid: - service: orcid - identifier: 0000-0001-9361-8333 -instrument: - device_information: - vendor: SPECS GmbH - model: Custom NAP-XPS instrument - identifier: null - energy_resolution: - type: calibrated - resolution: - value: 0.2 - unit: eV - source_xray: - type: Fixed Tube X-ray - probe: photon - device_information: - vendor: SPECS GmbH - model: µFOCUS 500 - identifier: null - beam_xray: - distance: - value: 0.0 - unit: mm - analyser: - description: hemispherical - device_information: - vendor: SPECS GmbH - model: PHOIBOS 150 NAP - identifier: null - collectioncolumn: - scheme: angular dispersive - device_information: - vendor: SPECS GmbH - model: PHOIBOS 150 NAP - identifier: null - energydispersion: - scheme: hemispherical - diameter: - unit: mm - value: 150 - device_information: - vendor: SPECS GmbH - model: PHOIBOS 150 - identifier: null - detector: - amplifier_type: channeltron - detector_type: Multi-anode - device_information: - vendor: Surface Concept GmbH - model: 1D-DLD detector - identifier: null - manipulator: - device_information: - vendor: SPECS GmbH - model: 5-axis manipulator - identifier: v1.0 - temperature_sensor: - name: type K thermocouple - measurement: temperature - attached_to: sample - type: type K thermocouple - value: - value: 298.0 - unit: K - sample_heater: - name: Coherent Compact Evolution IR Diode LASER (DILAS) - physical_quantity: temperature - type: IR diode laser - heater_power: - value: 0.0 - unit: W - pid: - setpoint: - value: 298.0 - unit: K - cryostat: - name: null - physical_quantity: null - type: null - pid: - setpoint: null - drain_current_amperemeter: - name: Amperemeter 1.0 - measurement: current - type: wire - value: - value: 0.1 - unit: nA - sample_bias_voltmeter: - name: XPS sample voltmeter - measurement: voltage - attached_to: sample - type: oscilloscope - value: - value: 0.0 - unit: V - sample_bias_potentiostat: - name: XPS sample potentiostat - physical_quantity: voltage - type: potentiostat - pid: - setpoint: - value: 0.0 - unit: V - pressure_gauge: - name: Atmion - measurement: pressure - type: hot-filament ionization gauge - value: - value: 0.000000001 - unit: mbar - value_log: - value: - value: null - unit: null - flood_gun: - name: FG 22/35 - physical_quantity: current - type: low energy electron source - current: - value: 0.0 - unit: A - current_log: - value: - value: null - unit: null -sample: - name: Polycristalline Au foil - sample_id: S718 - atom_types: Au - physical_form: foil - situation: vacuum - substance: - name: Au - molecular_mass: - value: 196.96657 - unit: g/mol - cas_number: 7440-57-5 - molecular_formula_hill: Au - history: - sample_preparation: - start_time: 2022-04-08T11:25:00.200Z - end_time: 2022-04-08T11:45:00.200Z - description: sputter cleaned with Ar ions for 20 min - method: Ar sputtering \ No newline at end of file