#include "m328_readings.h"
#include "common.h"
#include "temp.h"
#include <Arduino.h> // ???
/* TEMP 10000*C */
// https://code.google.com/p/tinkerit/wiki/SecretThermometer
long m328_read_Temp() {
long result;
// Read temperature sensor against 1.1V reference
ADMUX = _BV(REFS1) | _BV(REFS0) | _BV(MUX3);
delay(5); // Wait for Vref to settle
ADCSRA |= _BV(ADSC); // Convert
while (bit_is_set(ADCSRA,ADSC));
result = ADCL;
result |= ADCH<<8;
result = (result - 125) * 1075 ;
return result;
}
/* VCC*1000 */
// https://code.google.com/p/tinkerit/wiki/SecretVoltmeter
long m328_read_Vcc() {
long result;
// Read 1.1V reference against AVcc
ADMUX = _BV(REFS0) | _BV(MUX3) | _BV(MUX2) | _BV(MUX1);
delay(5); // Wait for Vref to settle
ADCSRA |= _BV(ADSC); // Convert
while (bit_is_set(ADCSRA,ADSC));
result = ADCL;
result |= ADCH<<8;
result = 1126400L / result; // Back-calculate AVcc in mV
return result;
}
/*
Print m328 readings
*/
void m328_print_readings(void) {
long temp, vcc;
temp = m328_read_Temp();
vcc = m328_read_Vcc();
MSG_TMP("LOCAL value='"); temp_print_value_long(temp,10000); PRINTF("' unit='C' dev_type='m328'\n");
MSG("VCC LOCAL value='%ld' unit='mV' dev_type='m328'\n", vcc);
}