Skip to content

Commit 94de8c5

Browse files
committed
Revert comit to master in error
This reverts commit 8d9b023.
1 parent 8d9b023 commit 94de8c5

File tree

1 file changed

+24
-2
lines changed

1 file changed

+24
-2
lines changed

doc/processes/instrument_details/HRPD-Instrument-Details.md

Lines changed: 24 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -1,11 +1,10 @@
11
# HRPD
22

33
This page collects information that will be useful for the implementation of the IBEX control system on HRPD.
4-
54
## Background & Timeline ##
65
HRPD, the High Resolution Powder Diffractometer is an instrument on TS1 at ISIS. It is the highest resolution neutron powder diffractometer of its type in the world. The [HRPD](http://www.isis.stfc.ac.uk/instruments/hrpd/hrpd.html) web page describes the background to the instrument.
76

8-
HRPD is currentl being rebuilt as HRPD-X
7+
There is a proposal to re-build HRPD at some point in the next 3-5 years.
98

109
## HRPD Equipment ##
1110
The equipment listed below is used on HRPD. Please add new information (e.g. new items of equipment, new notes, information about drivers, etc. to this table).
@@ -103,3 +102,26 @@ See [magnets at ISIS](http://www.isis.stfc.ac.uk/sample-environment/high-magneti
103102
{#hrpd_noteRamanSpect}
104103
##### Note: mini-Raman Spectrometer #####
105104
1. [B&W Tek i-Raman Plus](http://bwtek.com/products/i-raman-plus/) A Raman Spectrometer is something that HRPD would like to use at a future date (TBD). See also SXD.
105+
106+
## HRPD SECI Configs ##
107+
HRPD has numerous heritage SECI configurations only two of which are now used routinely.
108+
109+
1. One is used for day-to-day operation with samples at RT, in cryostats or furnace (`HRPD_Eurotherms_2.conf`).
110+
1. The second is used with the sample changer (`HRPD_Sample_Changer_new_oct16.conf`).
111+
112+
All located in `C:\\Program Files (x86)\STFC ISIS Facility\SECI\Configurations`
113+
114+
The HRPD team would probably wish to have separate configurations for experiments involving:
115+
116+
1. High-pressure devices (incl. various pressure transducers)
117+
1. Gas handling
118+
1. Magnets
119+
1. In-situ light scattering (laser control, spectrometer data acquisition)
120+
121+
## HRPD Genie Scripts ##
122+
The critical OpenGenie scripts, for initialisation and focussing, are in `C:\\OG` (duplicated, more or less, in `C:\\scripts\OG`)
123+
124+
HRPD has a large collection of Genie scripts accumulated over the years, each of results from a specific user running a specific operation. A number of editable seed scripts are kept in (`C:\\scripts\keep`). These might appropriately be converted to genie_python.
125+
126+
## HRPD Notes ##
127+
Add any notes about special items of equipment, setup or conditions on HRPD that might impact the deployment and configuration of IBEX.

0 commit comments

Comments
 (0)