Notifications
You must be signed in to change notification settings - Fork 1
/
components_regulation.py
152 lines (107 loc) · 7.42 KB
/
components_regulation.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
# -*- coding: utf-8 -*-
"""
Created on Mon Feb 27 10:34:18 2023
@author: jkalanger
"""
import numpy as np
from general_scripts import pressure_drop
def pressure_regulation(T_water_profiles,otec_plant_nom,inputs,HX):
if HX == 'evap':
T_sat_ts = np.where(T_water_profiles - otec_plant_nom['Q_evap_nom']/(otec_plant_nom['m_WW_nom']*inputs['cp_water']) - otec_plant_nom['T_evap_nom'] < inputs['T_pinch_WW'],
T_water_profiles - otec_plant_nom['del_T_WW'] - inputs['T_pinch_WW'],
otec_plant_nom['T_evap_nom'])
elif HX == 'cond':
T_sat_ts = np.where(otec_plant_nom['T_cond_nom'] - (T_water_profiles - otec_plant_nom['Q_cond_nom']/(otec_plant_nom['m_CW_nom']*inputs['cp_water'])) < inputs['T_pinch_CW'],
T_water_profiles + otec_plant_nom['del_T_CW'] + inputs['T_pinch_CW'],
otec_plant_nom['T_cond_nom'])
else:
raise ValueError('Invalid heat exchanger input. Please choose between "evap" and "cond".')
p_sat_ts = 0.00002196*T_sat_ts**3+0.00193103*T_sat_ts**2+0.1695763*T_sat_ts+4.25739601
return T_sat_ts,p_sat_ts
def initial_NTU_and_epsilon(inputs,otec_plant_nom,HX):
if HX == 'evap':
suffix = ['evap','WW_nom']
elif HX == 'cond':
suffix = ['cond','CW_nom']
else:
raise ValueError('Invalid heat exchanger input. Please choose between "evap" and "cond".')
NTU_initial = (inputs['U_'+suffix[0]]*otec_plant_nom['A_'+suffix[0]])/(otec_plant_nom['m_'+suffix[1]]*inputs['cp_water'])
epsilon_initial = 1 - np.exp(-NTU_initial)
return NTU_initial,epsilon_initial
def evaporator_regulation(enthalpies_ts,T_WW_profiles,T_evap_ts,epsilon_evap_initial,inputs,otec_plant_nom):
T_WW_out_initial = T_WW_profiles - epsilon_evap_initial * (T_WW_profiles - T_evap_ts)
m_NH3_initial = (-otec_plant_nom['m_WW_nom']*inputs['cp_water']*(T_WW_out_initial-T_WW_profiles)/(enthalpies_ts['h_3']-enthalpies_ts['h_2']))
# This boolean determines whether ammonia mass flow is restricted by turbine limitations
bool_turb = np.where(m_NH3_initial*(enthalpies_ts['h_4']-enthalpies_ts['h_3']) < otec_plant_nom['p_gross_nom'],1,0)
# This boolean determines whether ammonia mass flow is restricted by condenser limitations
bool_cond = np.where((bool_turb == 0) & (m_NH3_initial*(enthalpies_ts['h_1']-enthalpies_ts['h_4']) < otec_plant_nom['Q_cond_nom']),1,0)
# This boolean determines whether ammonia mass flow is restricted by evaporator limitations
bool_evap = np.where((bool_turb == 0) & (m_NH3_initial*(enthalpies_ts['h_1']-enthalpies_ts['h_4']) >= otec_plant_nom['Q_cond_nom']),1,0)
m_NH3_turb = otec_plant_nom['m_NH3_nom']
Q_evap_turb = m_NH3_turb*(enthalpies_ts['h_3']-enthalpies_ts['h_2'])
T_WW_out_turb_iteration = T_WW_out_initial
difference = np.ones(np.size(bool_turb))
while np.any(abs(difference) > 1E-7):
T_WW_out_turb = T_WW_out_turb_iteration
m_WW_turb = -Q_evap_turb/(inputs['cp_water']*(T_WW_out_turb-T_WW_profiles))
u_evap_turb = inputs['U_evap']*(m_WW_turb/otec_plant_nom['m_WW_nom'])**0.65
NTU_evap_turb = u_evap_turb*otec_plant_nom['A_evap']/(m_WW_turb*inputs['cp_water'])
epsilon_evap_turb = 1-np.exp(-NTU_evap_turb)
T_WW_out_turb_iteration = T_WW_profiles-epsilon_evap_turb*(T_WW_profiles-T_evap_ts)
difference = T_WW_out_turb_iteration - T_WW_out_turb
T_WW_out_turb = T_WW_out_turb_iteration
# Here we make sure that the condenser heat flow does not exceed the nominal design value
m_NH3_target = otec_plant_nom['Q_cond_nom']/(enthalpies_ts['h_1']-enthalpies_ts['h_4'])
m_NH3_cond = np.ones(np.shape(m_NH3_target),dtype=np.float64)*otec_plant_nom['m_NH3_nom']
m_NH3_cond[m_NH3_target <= otec_plant_nom['m_NH3_nom']] = m_NH3_target[m_NH3_target <= otec_plant_nom['m_NH3_nom']]
m_WW_cond = otec_plant_nom['m_WW_nom']
T_WW_out_cond = T_WW_out_initial
Q_evap_cond = m_NH3_cond*(enthalpies_ts['h_3']-enthalpies_ts['h_2'])
m_NH3_evap = otec_plant_nom['m_NH3_nom']
m_WW_evap = otec_plant_nom['m_WW_nom']
T_WW_out_evap = T_WW_out_initial
Q_evap_evap = - m_WW_evap*inputs['cp_water']*(T_WW_out_initial-T_WW_profiles)
# suffix ts stands for time series
m_NH3_ts = m_NH3_turb*bool_turb + m_NH3_cond*bool_cond + m_NH3_evap*bool_evap
m_WW_ts = m_WW_turb*bool_turb + m_WW_cond*bool_cond + m_WW_evap*bool_evap
T_WW_out_ts = T_WW_out_turb*bool_turb + T_WW_out_cond*bool_cond + T_WW_out_evap*bool_evap
Q_evap_ts = Q_evap_turb*bool_turb + Q_evap_cond*bool_cond + Q_evap_evap*bool_evap
# Sanity check whether regulated values do not exceed nominal design values
if np.any(np.round(np.amax(m_NH3_ts, axis=0),1) > np.round(otec_plant_nom['m_NH3_nom'],1)):
raise Warning('Ammonia mass flow exceeds nominal design value.')
if np.any(np.round(np.amax(m_WW_ts, axis=0),1) > np.round(otec_plant_nom['m_WW_nom'],1)):
raise Warning('Warm seawater mass flow exceeds nominal design value.')
if np.any(np.round(np.amax(Q_evap_ts, axis=0),1) > np.round(otec_plant_nom['Q_evap_nom'],1)):
raise Warning('Evaporator heat flow exceeds nominal design value.')
if np.any(np.round(np.amin(T_WW_out_ts - T_evap_ts, axis=0),1) < np.round(inputs['T_pinch_WW'],1)):
raise Warning('Warm water pinch temperature below nominal design value.')
return m_NH3_ts,m_WW_ts,T_WW_out_ts,Q_evap_ts
def condenser_regulation(T_CW_profiles,inputs,otec_plant_nom,m_NH3_ts,T_cond_ts,enthalpies_ts,epsilon_cond_initial):
T_CW_out_initial = T_CW_profiles + epsilon_cond_initial*(T_cond_ts-T_CW_profiles)
Q_cond_ts = m_NH3_ts*(enthalpies_ts['h_1'] - enthalpies_ts['h_4'])
m_CW_ts = otec_plant_nom['m_CW_nom']
T_CW_out_ts = T_CW_out_initial
T_CW_out_iteration = T_CW_out_initial
difference = np.ones(np.size(T_CW_out_initial))
while np.any(abs(difference) > 1E-7):
T_CW_out_ts = T_CW_out_iteration
m_CW_ts = -Q_cond_ts/(inputs['cp_water']*(T_CW_out_ts-T_CW_profiles))
u_cond_ts = inputs['U_cond']*(m_CW_ts/otec_plant_nom['m_CW_nom'])**0.65
NTU_cond_ts = u_cond_ts*otec_plant_nom['A_cond']/(m_CW_ts*inputs['cp_water'])
epsilon_cond_ts = 1-np.exp(-NTU_cond_ts)
T_CW_out_iteration = T_CW_profiles-epsilon_cond_ts*(T_CW_profiles-T_cond_ts)
difference = T_CW_out_iteration - T_CW_out_ts
T_CW_out_ts = T_CW_out_iteration
# Sanity check whether regulated values do not exceed nominal design values
if np.any(np.round(np.amin(Q_cond_ts, axis=0),1) < np.round(otec_plant_nom['Q_cond_nom'],1)):
raise Warning('Condenser heat flow exceeds nominal design value.')
if np.any(np.round(np.amin(T_cond_ts - T_CW_out_ts, axis=0),1) < np.round(inputs['T_pinch_WW'],1)):
raise Warning('Cold water pinch temperatire below nominal design value.')
return T_CW_out_ts,m_CW_ts,Q_cond_ts
def seawater_pipes_operation(otec_plant_nom,inputs,m_water_ts,t_water_in,rho_water,length,A_pipes,d_pipes,roughness_pipe,K_L,u_HX):
V_water_ts = m_water_ts/rho_water
u_water_ts = V_water_ts/A_pipes
u_HX_ts = u_water_ts/2
p_drop_ts = pressure_drop(t_water_in,u_water_ts,d_pipes,rho_water,roughness_pipe,length,K_L,u_HX_ts)
p_pump_ts = m_water_ts/rho_water*p_drop_ts/inputs['eff_hyd']/inputs['eff_el']
return p_drop_ts,p_pump_ts