Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathhs6PROCESS_SEABASS.m
257 lines (233 loc) · 13 KB
/
hs6PROCESS_SEABASS.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
% hs6PROCESS_SEABASS
% Jesse Bausell
% September 13, 2017
%
% Updated: June 11, 2019
%
% This matlab script takes raw hs6 data files that are produced by
% HydroSoft, a commercial software package produced by HOBI Labs, parent
% company of hs6. hs6PROCESS_SEABASS re-organizes data into a format that
% is compatible with NASA's SEABASS data portal. Data, should NOT be
% sigma-corrected in HydroSoft, as this script performs sigma-correction if
% indicated by the metadata file (see readme).
%
% Required matlab scripts and functions:
% Doxarian_SIGMA.m
% hs6_binFUNCTION.m
% HS6_fileREADER_MS.m
% metaData_Reader_hs6.m
% morel_Correction_pw.m
%
% Required data files:
% Seabass_header_ACS5.mat
clear all; close all; clc;
%% 1. Read in HS6 data
% Read in the selected HS6 file and creates the variables and create variables
% to be used in the rest of the program.
HS6_fileREADER_MS; % Script to uipload data and create variables associated
% with particulate backscattering.
%% 2. Time-syncrhonize hs-6 data.
% hs-6 data is commonly collected in conjunction with ac-s data (or data
% from another instrument). To submit data onto Seabass, time-stamp
% variables from synchronously deployed instruments must be time-stamped.
% The following interactive code allows user to calibrate a time stamp in
% so that it will be synchronous with another instrument (see readme).
keY = 1; % reference variable for cycling through the while-loop below
while 1
% This large while-loop enables user to interactively synchronize hs6
% data with another instrument that was deployed simultaneously. It
% eliminates the guess work of doing this by hand with pen and paper.
if isequal(keY,1)
% If reference variable is 1, this code displays a time-series
% (time defined as cast index of hs6 position (depth) in the water
% column. It asks user to then chose an index to use as a reference
% point in the automated time synchronization.
disp('Select a point as reference time'); % dispay in the command window
plot(deptH,'b','LineWidth',2); % Plot depth over bbp specrum index
xlabel('Index','FontSize',20); ylabel('Depth (m)','FontSize',20); % label axes
title('HS6 Cast Depth','FontSize',20); % plot title
set(gca,'ydir','reverse'); % orient plot in correct direction
time_IND = input('Select a time point: '); % ask user to select a time point
close all; clc; keY = keY + 1; % close everything
elseif isequal(keY,2)
% In the event user selected a reference point, re-plot the
% previous figure (see above) including the selected data point.
% This plot allows user to see his/her selection.
plot(deptH,'b','LineWidth',2); hold on; % Re-plot depth over bbp specrum index
scatter(time_IND,deptH(time_IND),'or','MarkerFaceColor','r'); % Plot user-selected reference point
xlabel('Index','FontSize',20); ylabel('Depth (m)','FontSize',20); % Re-plot labels
title('HS6 Cast Depth','FontSize',20); % Re-plot title
set(gca,'ydir','reverse'); % Orient the plot correctly
while 1
% This nested while-loop gives uer an opportunity to
% approve/reject previously selected reference point while
% viewing it (see code directly above)
% asks user to accepts or rejects reference point
question = input('Accept this point as reference time? (y/n): ','s');
if strcmpi(question,'y')
% User accepts reference point
keY = keY+1; % While-loop reference variable (keY) increases
break % nested while-loop is broken
elseif strcmpi(question,'n')
keY = 1; % While loop reference variable decreases to original value
% This causes the large while-loop to reset and begin again
% anew.
close all; % All open figures are closed
break % nested for-loop is broken
else
% User makes invalid entry
disp('Invalid selection. Must select y or n.') % Displays warning message
% User is prompted to correct his/her command window entry
end
end
else
% If while-loop reference variable is increased to 3 (AKA: user
% selects and accepts a reference index for the automated time
% syncrhonization
while 1
% Nested while loop prompts user to define reference index with
% a time stamp. User is prompted to enter a time-stamp
% (military time, hours:minutes:seconds) manually.
ref_time = input('Enter Reference Time (HH:MM:SS):' ,'s'); % Prompts user to enter time stamp
q10 = input('Is this reference time acceptable? (y/n): ','s'); % Asks user to accept/reject time stamp
if strcmpi(q10,'y')
% If user accept the time stamp he/she entered, this
% section of code will create an array of time stamps for
% each hs6 (bbp & fl) measurement.
title(ref_time); % Stamp title onto re-plotted figure containing hs6 depth profiles + user-selected reference time point
ref_time = datenum(ref_time) - floor(datenum(ref_time)); % Convert reference to matday (no days, only time)
delta_t = timE - timE(time_IND); % calculates time differences from reference time
tiME = ref_time + delta_t; % Calculates time for all bb/fl measurements in terms of actual time (using time differences)
% Now that time has been converted into matday and re-scaled
% according to input time stamp, first and last time value
% are converted to strings, day (whole number) is discarded
% and first and last values are converted to strings for
% eventual use in the header
start_time = datestr(tiME(1),'HH:MM:SS'); % Start time
stop_time = datestr(tiME(end),'HH:MM:SS'); % Stop time
break % Break the while-loop. Time arrayfor hs6 has been created.
elseif strcmpi(q10,'n')
% If user rejects his/her previously input time stamp.
clc; % clear the command window
disp('Try again.'); % Instruct user to try again
end
savefig([in_DIR in_FILE(1:end-4)]); % Save the currently opened figure
% Currently opened figure (never closed from before) consists
% of the hs6 depth time series (instrument depth over time,
% with "time" displayed as measurement index), user-selected
% reference point, and user-selected reference time stamp as
% the title. This is saved as a matlab figure and can be used
% for future reference.
end
break % break the while-loop. It is no longer necessary
end
end
%% 3. QA/QC HS6 data.
% Now that all backscattering processing steps have been applied (creating
% particulate backscattering from backscattering), bbp and fl are combined
% into one data matrix.
HS6_data = [HS6_data HS6_data_fl]; % Combines the bb and fl
HS6_min = min(HS6_data,[],2); % Finds maximum value in each row of data
HS6_max = max(HS6_data,[],2); % Finds minimum value in each row of data
bad_IND = find(HS6_min < 0 | HS6_max > 0.5); % Flag all rows with values > 0.5 or < 0
% Eliminate all flagged rows from:
HS6_data(bad_IND,:) = []; % bbp and fl
deptH(bad_IND) = []; % depth
tiME(bad_IND) = []; % time
%% 4. Create the Seabass HS6 file header
% Now that the data itself has been processed and is Seabass-ready,
% hs6PROCESS_SEABASS.m now creates a header. This header will be used for
% single-measurement (yo-yo) file, as well as Doxaran-corrected
% depth-binned files should the user specify their creation.
load('Seabass_header_ACS5.mat');
% Generic header field data. Originally made for ac-s, but the first 25
% header lines work here too.
fid_hs6 = fopen([in_DIR experiment '_' station '_bb' '.txt'],'w');
% Create Header in the file: Header lines 1-25
fprintf(fid_hs6,'%s\n',headER(1).c); %Line 1
fprintf(fid_hs6,'%s\n',[headER(2).c datestr(datenum(date),'yyyymmdd')]); %Line 2
fprintf(fid_hs6,'%s\n',[headER(3).c affiliations]); %Line 3
fprintf(fid_hs6,'%s\n',[headER(4).c investigators]); %Line 4
fprintf(fid_hs6,'%s\n',[headER(5).c contact]); %Line 5
fprintf(fid_hs6,'%s\n',[headER(6).c experiment]); %Line 6
fprintf(fid_hs6,'%s\n',[headER(7).c experiment '_' dat]); %Line 7
fprintf(fid_hs6,'%s\n',[headER(8).c station]); %Line 8
fprintf(fid_hs6,'%s\n',headER(9).c); %Line 9
fprintf(fid_hs6,'%s\n',[headER(10).c lon '[deg]']); %Line 10
fprintf(fid_hs6,'%s\n',[headER(11).c lon '[deg]']); %Line 11
fprintf(fid_hs6,'%s\n',[headER(12).c lat '[deg]']); %Line 12
fprintf(fid_hs6,'%s\n',[headER(13).c lat '[deg]']); %Line 13
fprintf(fid_hs6,'%s\n',[headER(15).c dat]); %Line 14
fprintf(fid_hs6,'%s\n',[headER(16).c dat]); %Line 15
fprintf(fid_hs6,'%s\n',[headER(17).c start_time '[GMT]']); %Line 16
fprintf(fid_hs6,'%s\n',[headER(18).c stop_time '[GMT]']); %Line 17
fprintf(fid_hs6,'%s\n',[headER(19).c in_FILE]); %Line 18
fprintf(fid_hs6,'%s\n',[headER(20).c 'NA']); %Line 19
fprintf(fid_hs6,'%s\n',[headER(26).c cal_FILE_ac]); %Line 20
fprintf(fid_hs6,'%s\n',headER(21).c); %Line 21
if ~strcmpi(doC,'NA'); % Line 22
% User specifies additional document in header file
fprintf(fid_hs6,'%s\n',['/documents=kudelalab_HS6_readme.pdf' ',' doC]); %Line 22
else
% User declines to specify additional document in header file
fprintf(fid_hs6,'%s\n','/documents=kudelalab_HS6_readme.pdf'); %Line 22
end
fprintf(fid_hs6,'%s\n',headER(23).c); %Line 23
fprintf(fid_hs6,'%s\n',headER(24).c); %Line 24
fprintf(fid_hs6,'%s\n',[headER(25).c D]); %Line 25
% Create fields and units header lines for Seabass data file
fields = '/fields=time,depth'; % start with the first two fields (they shouldnt' change)
units = '/units=hh:mm:ss,m'; % start with first two units of measurement (they shouldnt' change either)
print_fodder = '%1.3f'; % starts with first two format specifiers for printing .txt file data
for ii = lambdA
% Add backscattering fields to the fields header
fields = [fields ',bbp' num2str(ii)];
units = [units ',1/m'];
print_fodder = [print_fodder '\t%1.6f'];
end
fields = [fields ',stimf_ex470_em510,stimf_ex442_em700']; % Add fluorescence fields
units = [units ',volts,volts']; % Add fluorescence units
print_fodder = [print_fodder '\t%1.6f\t%1.6f\n']; % Add format specifiers for fluorescence
% WARNING: Fluorescence fields and units are hard-coded into hs6PROCESS_SEABASS!!
fprintf(fid_hs6,'%s\n',fields); %Line 26 - "fields" header line
fprintf(fid_hs6,'%s\n',units); %Line 27 - "units" header line
% Lines 28-32 - close out header with hard-coded notes to data consumer
fprintf(fid_hs6,'%s\n','! Data are likely to contain multiple downcasts and upcasts. All downcasts and upcasts are included in this submission.');
fprintf(fid_hs6,'%s\n','! Contaminated bbp spectra were excluded from this file');
fprintf(fid_hs6,'%s\n','! Contaminated bbp spectra are defined as spectra for which bb or corresponding fl are greater than 0.5, or negative.');
fprintf(fid_hs6,'%s\n','! Data have been processed using code written and made avaiable by Jesse Bausell (email: jbausell@ucsc.edu, GitHub: JesseBausell).');
fprintf(fid_hs6,'%s\n','/end_header');
%% 5. Print the Seabass HS6 data matrix
% Now that the Seabass header has been formed, data is printed into the
% Seabass-formatted file of processed hs6 data.
% Create a time string for the Seabass-formatted .txt file
TIME = cell(length(tiME),1); % Create empty cell array for time strings
for ii = 1:length(tiME)
% Create a time string for each set of bbp and fl measurements using
% matdate time variable
TIME{ii} = datestr(tiME(ii),'HH:MM:SS'); % Convert matdate time to time string (military time)
end
HS6_mat = [deptH HS6_data]; % Combine depth with bbp and fl to make total matrix of hs6 processed data
for ii = 1:length(deptH)
% For-loop prints each row of data into Seabass formatted .txt file,
% one row at a time
fprintf(fid_hs6,'%s\t',TIME{ii}); % Print time stamp
fprintf(fid_hs6,print_fodder,HS6_mat(ii,:)); % Print depth, bbp, and fl
end
fclose(fid_hs6); % Close file
%% 6. Produce binned files
% If user specifies binned absorption files in the metadata header, this
% section will
if ~isempty(binned_ABS(1).FILES)
% If user selects to run Doxaran sigma-correction by listing binned
% ac-s absorption files in metadata header.
diR_acs = binned_ABS(1).PTHWY;
for ii = 1:length(binned_ABS)
% This for-loop cycles through binned absorption files listed in
% the metadata header. It performs a Doxaran sigma-correction for
% each of them.
filE_acs = [diR_acs binned_ABS(ii).FILES]; %Give ac-s file and pathway it's own variable
filE_hs6 = [in_DIR experiment '_' station '_bb' '.txt']; %Give hs6 file and pathway it's own variable
hs6_binFUNCTION(filE_acs,filE_hs6,kexp); % Create binned hs6 file with sigma-corrected bbp
end
end