Propulsion Microcontroller API

Anthony Randell edited this page Nov 23, 2016 · 22 revisions

Usage of this Page

This page contains the commands used when communicating to and from the Wireless Communication Modules.

More details about the communication protocol can be found via the API Documentation Homepage.

Command 0x10 – Reset Motor Controller

Request Message:

  • Payload Size: 1 byte (null)

Response Message:

  • Payload Size: 1 byte

Command 0x11 – Set Motor Controller Configuration

Request Message:

Byte Description Valid Range
13 (MSB) MSB of Set Indicator Word 0b00000000 to 0b00001111
12 LSB of Set Indicator Word 0b00000000 to 0b11111111
11 Device ID 0 to 127
10 PWM Parameter 0 to 5
9 Shut Down Motors on Error 0 to 7
8 Serial Timeout 0 to 127
7 Motor M0 Acceleration 0 to 127
6 Motor M1 Acceleration 0 to 127
5 Motor M0 Brake Duration 0 to 127
4 Motor M1 Brake Duration 0 to 127
3 Motor M0 Current Limit / 2 0 to 127
2 Motor M1 Current Limit / 2 0 to 127
1 Motor M0 Current Limit Response 0 to 127
0 (LSB) Motor M1 Current Limit Response 0 to 127

Response Message:

Byte Description Valid Range
12 Reserved for Expansion 0
11 Device ID 0 to 127
10 PWM Parameter 0 to 5
9 Shut Down Motors on Error 0 to 7
8 Serial Timeout 0 to 127
7 Motor M0 Acceleration 0 to 127
6 Motor M1 Acceleration 0 to 127
5 Motor M0 Brake Duration 0 to 127
4 Motor M1 Brake Duration 0 to 127
3 Motor M0 Current Limit / 2 0 to 127
2 Motor M1 Current Limit / 2 0 to 127
1 Motor M0 Current Limit Response 0 to 127
0 (LSB) Motor M1 Current Limit Response 0 to 127

Command 0x12 – Get Motor Controller Configuration

Request Message:

  • Payload Size: 1 byte (null)
  • This command reads the configuration of the motor controller without modifying any of the settings

Response Message:

Byte Description Valid Range
12 Reserved for Expansion 0
11 Device ID 0 to 127
10 PWM Parameter 0 to 5
9 Shut Down Motors on Error 0 to 7
8 Serial Timeout 0 to 127
7 Motor M0 Acceleration 0 to 127
6 Motor M1 Acceleration 0 to 127
5 Motor M0 Brake Duration 0 to 127
4 Motor M1 Brake Duration 0 to 127
3 Motor M0 Current Limit / 2 0 to 127
2 Motor M1 Current Limit / 2 0 to 127
1 Motor M0 Current Limit Response 0 to 127
0 (LSB) Motor M1 Current Limit Response 0 to 127

Command 0x13 – Set Motor Speeds

Request Message:

  • Payload Size: 9 bytes
  • Used to set the speed of both motors simultaneously

Response Message:

  • The response from the microcontroller to a set motor speed is to reply with the new motor speed to confirm the set was successful
  • Payload Size: 9 bytes
Byte Description Valid Range
8 (MSB) Reserved for Expansion 0
7 M0 Speed (MSB) Integer -100 to 100
6 M0 Speed Integer -100 to 100
5 M0 Speed Integer -100 to 100
4 M0 Speed (LSB) Integer -100 to 100
3 M1 Speed (MSB) Integer -100 to 100
2 M1 Speed Integer -100 to 100
1 M1 Speed Integer -100 to 100
0 M1 Speed (LSB) Integer -100 to 100

Command 0x14 - Get Motor Currents

Request Message:

  • Used to request the current being consumed by both motors.
  • Payload Size: 1 byte (null)

Response Message:

  • Reply from the microcontroller contains the current of both motors in milliamps.
  • Payload size: 9 bytes

|:---:|:---:|:---:| Byte|Description|Valid Range 0|Reserved for Expansion| 0 1|M0 Current|Integer > 0 2|M0 Current|Integer > 0 3|M0 Current|Integer > 0 4|M0 Current|Integer > 0 5|M1 Current|Integer > 0 6|M1 Current|Integer > 0 7|M1 Current|Integer > 0 8 (LSB)|M1 Current|Integer > 0