Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathdata_chp.m
135 lines (130 loc) · 4.49 KB
/
data_chp.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
% Input data file
%wind data
% Wind data
load('AV_AEMO');
% Wmin Wmax El_Bus
gridinfo.WindDATA=[
0 50 3; %1
0 50 2; %1
% 0 200 6; %1
];
gridinfo.ChpDATA=[
% Pmin Pmax R+ R- El_Bus C_el phi Hmin Hmax C_heat Coef
15 208.3 40 40 6 3.6 12.65 0 250 0.06002 1.5 ; %1
% 0 152 40 40 2 22 13.45 0 304 4 1.5; %2
];
gridinfo.HPDATA=[
% Hmin Hmax R+ R- El_Bus Cel Cheat COP
5 100 20 5 3 12 4 2.5; %1
% 0 152 40 40 2 22 4 0.9; %2
];
%Heat system data
%% District heating data
%gridinfo.Nodes=["N1"; "N2"; "N3"; "N4"; "N5"];
heatgrid.Nodes=[1; 2; 3; 4; 5; 6; 7];
%%Set of nodes with single pipes starting
%gridinfo.NodesS=["N5"; "N1"; "N3"];
heatgrid.NodesS=[1; 6];
%gridinfo.NodesE=["N1"; "N2"; "N3"; "N4"];
heatgrid.NodesE=[2; 3; 4; 5; 7;];
%Set of pipes ending at node N;
%%Matrix NODESxPIPES
PipesEND=[0 0 0 0 0 0;
1 0 0 0 0 0;
0 1 0 0 0 0;
0 0 1 0 1 0;
0 0 0 1 0 0;
0 0 0 0 0 0;
0 0 0 0 0 1;];
PipesSTART=[1 0 0 0 0 0;
0 1 1 0 0 0;
0 0 0 0 0 0;
0 0 0 1 0 1;
0 0 0 0 0 0;
0 0 0 0 1 0;
0 0 0 0 0 0;];
heatgrid.PipesEND=PipesEND;
heatgrid.PipesSTART=PipesSTART;
%Heat load
% Heat load Node mfMax mfmin
Hl=[
0 1 0 0;
0 2 0 0;
0.45 3 700 300; %l1
0 4 0 0;
0.40 5 700 300; %l2
0 6 0 0;
0.50 7 700 300; %l3
];
%Heat source heat data
% Node mfMax mfmin
HS=[
1 700 300; %s1
2 0 0;
3 0 0;
4 0 0;
5 0 0;
6 700 300; %s2
7 0 0;
];
%%IF ADD CHP or HP DONT FOGET TO CHANGE REALLY IMPORTANT!!!!!!!!!
hs_node=[1; 0; 0; 0; 0; 2; 0;];
chp_node=[1; 0; 0; 0; 0; 0; 0;];
hp_node=[0; 0; 0; 0; 0; 1; 0;];
%%IF ADD CHP or HP DONT FOGET TO CHANGE REALLY IMPORTANT!!!!!!!!!
heatgrid.hs_node=hs_node;
heatgrid.chp_node=chp_node;
heatgrid.hp_node=hp_node;
heatgrid.Hl =Hl(:,1);
heatgrid.mf_l_max=Hl(:,3);
heatgrid.mf_l_min=Hl(:,4);
heatgrid.mf_C_max=HS(:,2);
heatgrid.mf_C_min=HS(:,3);
%%
heatgrid.NodeL=[3; 5; 7;];
heatgrid.NodeSource=[1; 6;];
heatgrid.NodeHP=[6;];
heatgrid.NodeCHP=[1;];
%%
%maximum mass flow rates of the load
%%Temperature limits
heatgrid.Ts_max=[65; 65; 65; 65; 65; 65; 65]
heatgrid.Ts_min=[50; 50; 50; 50; 50; 50; 50]
heatgrid.Tr_max=[45; 45; 45; 45; 45; 45; 45]
heatgrid.Tr_min=[25; 25; 25; 25; 25; 25; 25;]
%%Presure limits
heatgrid.prS_max=[30000; 30000; 30000; 30000; 30000; 30000; 30000]
heatgrid.prS_min=[0; 0; 0; 0; 0; 0; 0]
heatgrid.prR_max=[30000; 30000; 30000; 30000; 30000; 30000; 30000]
heatgrid.prR_min=[0; 0; 0; 0; 0; 0; 0]
heatgrid.pr_diff_min=[0; 0; 50; 0; 50; 0; 50]
%% Pipes data
pipes_data_S=[
%pipe %from %to %lemgth,m minMF maxMF minT, C max, T
1 1 2 800 300 700 50 65;
2 2 3 600 300 700 50 65;
3 2 4 800 300 700 50 65;
4 4 5 500 300 700 50 65;
5 6 4 800 300 700 50 65;
6 4 7 500 300 700 50 65;
];
heatgrid.mfS_max=pipes_data_S(:,6);
heatgrid.mfS_min=pipes_data_S(:,5);
heatgrid.Tpipe_S_max=pipes_data_S(:,8);
heatgrid.Tpipe_S_min=pipes_data_S(:,7);
heatgrid.Lp=pipes_data_S(:,4);
%Return pipes
pipes_data_R=[
%pipe %from %to %lemgth,m minMF maxMF minT, C max, T
1 2 1 800 300 700 25 45;
2 3 2 600 300 700 25 45;
3 4 2 800 300 700 25 45;
4 5 4 500 300 700 25 45;
5 4 6 800 300 700 25 45;
6 7 4 500 300 700 25 45;
];
heatgrid.mfR_max=pipes_data_R(:,6);
heatgrid.mfR_min=pipes_data_R(:,5);
heatgrid.Tpipe_R_max=pipes_data_R(:,8);
heatgrid.Tpipe_R_min=pipes_data_R(:,7);
%%Set of HS stations