Using different SMP initial configurations for Topmodel and LASAM hydrological model #860

Open
stcui007 opened this issue Jul 23, 2024 · 0 comments

Comments

@stcui007
Copy link
Contributor

stcui007 commented Jul 23, 2024

In recent CONUS baseline testing, in particular for running Topmodel and Lumped Arid/Semi-arid Model (LASAM) model, in discussions with hydrologists, it has become apparent that there is a bit of intricacies for running these two models. The intricacies involve SoilMoistureProfile (SMP) submodule. For this submodule, different initial configuration files are needed to run different hydrological models. For running CFE, we have used the config_conceptual.txt equivalent of the initial config, which is appropriate. We have generated the initial config appropriately for each catchment at CONUS scale. For running Topmodel, config_topmodel.txt version of initial configuration should be used. In our testing, due to lack of initial configurations in this form on CONUS, we used the same initial configs as for CFE for SMP submodule with any needed input parameters for Topmodel initialized in the Sloth submodule. The computations run fine but the results probably can only be considered approximate. Using a single config_topmodel.txt for the SMP to run Topmodel appears to run only a few time steps, then abruply stops. For running LASAM, the appropriate version of initial configuration for SMP is config_layered.txt . Due to unavailability of accurate initial config for each catchment at CONUS scale, we used the same initial config for all catchments on CONUS. Nevertheless, This is an initial test of feasibility and in the process we debugged some module codes (such as memory leaking of LGAR-C) and uncovered the limit of some parameters beyond which some submodules would not work (ref. NextGen_on_CONUS in ngen documentation for more details). Despite the issues remaining as described above, this work has forged a path in performimg computations on such large scale, which makes future such computations within Ngen Framework more straightforward.

Current behavior

Unrealistic SMP initial configs. for Topmodel
Unrealistic SMP initial configs. for LASAM model

Expected behavior

Individually fitted SMP initial config. for each catchment at CONUS scale for Topmodel and LASAM.

Steps to replicate behavior (include URLs)

Screenshots

@stcui007 stcui007 changed the title Using different SMP initial configurations for LASAM hydrological model Using different SMP initial configurations for Topmodel and LASAM hydrological model Jul 23, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant