@@ -101,7 +101,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
101
101
// uninitialized sizing type
102
102
Real64 sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
103
103
EXPECT_TRUE (errorsFound);
104
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::ErrorType2, sizer.errorType ) );
104
+ EXPECT_ENUM_EQ ( AutoSizingResultType::ErrorType2, sizer.errorType );
105
105
EXPECT_NEAR (0.0 , sizedValue, 0.01 ); // unitialized sizing types always return 0
106
106
errorsFound = false ;
107
107
@@ -113,7 +113,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
113
113
// Test #1 - Zone Equipment, no autosizing
114
114
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
115
115
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
116
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
116
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
117
117
EXPECT_FALSE (sizer.wasAutoSized );
118
118
EXPECT_NEAR (5125.3 , sizedValue, 0.01 ); // hard-sized value
119
119
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -130,7 +130,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
130
130
state->dataSize ->ZoneEqSizing (1 ).DesCoolingLoad = sizedValue;
131
131
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
132
132
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
133
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
133
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
134
134
EXPECT_FALSE (sizer.wasAutoSized );
135
135
EXPECT_NEAR (5125.3 , sizedValue, 0.01 ); // hard-sized value
136
136
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -170,7 +170,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
170
170
sizer.zoneSizingInput (1 ).ZoneNum = 1 ;
171
171
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
172
172
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
173
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
173
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
174
174
EXPECT_TRUE (sizer.wasAutoSized );
175
175
EXPECT_NEAR (4981.71 , sizedValue, 0.01 );
176
176
EXPECT_NEAR (1.2 , state->dataEnvrn ->StdRhoAir , 0.01 );
@@ -186,7 +186,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
186
186
sizer.wasAutoSized = false ;
187
187
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
188
188
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
189
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
189
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
190
190
EXPECT_TRUE (sizer.wasAutoSized );
191
191
EXPECT_NEAR (4000.0 , sizedValue, 0.01 );
192
192
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -200,7 +200,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
200
200
sizer.wasAutoSized = false ;
201
201
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::CoilWater_CoolingHXAssisted), " MyHXCoil" , printFlag, routineName);
202
202
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
203
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
203
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
204
204
EXPECT_TRUE (sizer.wasAutoSized );
205
205
EXPECT_NEAR (4268.66 , sizedValue, 0.01 );
206
206
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -214,7 +214,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
214
214
sizer.wasAutoSized = false ;
215
215
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
216
216
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
217
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
217
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
218
218
EXPECT_TRUE (sizer.wasAutoSized );
219
219
EXPECT_NEAR (3500.0 , sizedValue, 0.01 );
220
220
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -228,7 +228,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
228
228
sizer.wasAutoSized = false ;
229
229
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::CoilDX_CoolingSingleSpeed), " MyDXCoil" , printFlag, routineName);
230
230
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
231
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
231
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
232
232
EXPECT_TRUE (sizer.wasAutoSized );
233
233
EXPECT_NEAR (4981.71 , sizedValue, 0.01 );
234
234
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -242,7 +242,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
242
242
sizer.wasAutoSized = false ;
243
243
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::CoilDX_CoolingSingleSpeed), " MyDXCoil" , printFlag, routineName);
244
244
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
245
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
245
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
246
246
EXPECT_TRUE (sizer.wasAutoSized );
247
247
EXPECT_NEAR (3899.81 , sizedValue, 0.01 );
248
248
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -256,7 +256,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
256
256
sizer.wasAutoSized = false ;
257
257
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::CoilDX_CoolingSingleSpeed), " MyDXCoil" , printFlag, routineName);
258
258
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
259
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
259
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
260
260
EXPECT_TRUE (sizer.wasAutoSized );
261
261
EXPECT_NEAR (4981.71 , sizedValue, 0.01 );
262
262
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -272,7 +272,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
272
272
sizer.wasAutoSized = false ;
273
273
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
274
274
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
275
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
275
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
276
276
EXPECT_FALSE (sizer.wasAutoSized );
277
277
EXPECT_NEAR (5500.0 , sizedValue, 0.01 ); // hard size value
278
278
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -305,7 +305,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
305
305
printFlag = false ;
306
306
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
307
307
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
308
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
308
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
309
309
EXPECT_FALSE (sizer.wasAutoSized );
310
310
EXPECT_NEAR (2700.8 , sizedValue, 0.0001 ); // hard-sized value
311
311
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -332,7 +332,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
332
332
printFlag = false ;
333
333
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
334
334
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
335
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
335
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
336
336
EXPECT_TRUE (sizer.wasAutoSized );
337
337
EXPECT_NEAR (4981.71 , sizedValue, 0.01 );
338
338
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -347,7 +347,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
347
347
printFlag = false ;
348
348
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
349
349
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
350
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
350
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
351
351
EXPECT_TRUE (sizer.wasAutoSized );
352
352
EXPECT_NEAR (4981.71 , sizedValue, 0.01 ); // no change in capacity because coil is in air loop
353
353
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -363,7 +363,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
363
363
printFlag = false ;
364
364
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
365
365
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
366
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
366
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
367
367
EXPECT_TRUE (sizer.wasAutoSized );
368
368
EXPECT_NEAR (4582.31 , sizedValue, 0.01 ); // change in capacity because precool conditions mixed with return
369
369
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -393,7 +393,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
393
393
printFlag = false ;
394
394
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
395
395
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
396
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
396
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
397
397
EXPECT_TRUE (sizer.wasAutoSized );
398
398
EXPECT_NEAR (4740.64 , sizedValue, 0.01 ); // change in capacity because precool conditions mixed with return
399
399
EXPECT_NEAR (158.33 , sizer.primaryAirSystem (1 ).FanDesCoolLoad , 0.01 ); // air loop fan heat is saved in sizer class
@@ -413,7 +413,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
413
413
printFlag = false ;
414
414
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
415
415
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
416
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
416
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
417
417
EXPECT_TRUE (sizer.wasAutoSized );
418
418
EXPECT_NEAR (unScaledCapacity * 0.5 , sizedValue, 0.01 ); // change in capacity because precool conditions mixed with return
419
419
EXPECT_NEAR (158.33 , sizer.primaryAirSystem (1 ).FanDesCoolLoad , 0.01 ); // air loop fan heat is saved in sizer class
@@ -432,7 +432,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
432
432
printFlag = false ;
433
433
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
434
434
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
435
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
435
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
436
436
EXPECT_TRUE (sizer.wasAutoSized );
437
437
EXPECT_NEAR (4500.0 , sizedValue, 0.01 ); // capacity precalculated and saved in FinalSysSizing(1).CoolingTotalCapacity
438
438
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -447,7 +447,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
447
447
printFlag = false ;
448
448
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
449
449
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
450
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
450
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
451
451
EXPECT_TRUE (sizer.wasAutoSized );
452
452
EXPECT_NEAR (3500.0 , sizedValue, 0.01 ); // capacity precalculated and saved in FinalSysSizing(1).CoolingTotalCapacity
453
453
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -463,7 +463,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
463
463
printFlag = false ;
464
464
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
465
465
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
466
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
466
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
467
467
EXPECT_TRUE (sizer.wasAutoSized );
468
468
EXPECT_NEAR (2500.0 , sizedValue, 0.01 ); // capacity precalculated and saved in UnitarySysEqSizing(1).DesCoolingLoad
469
469
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -481,7 +481,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
481
481
printFlag = false ;
482
482
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
483
483
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
484
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
484
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
485
485
EXPECT_TRUE (sizer.wasAutoSized );
486
486
EXPECT_NEAR (1500.0 , sizedValue, 0.01 ); // capacity precalculated and saved in OASysEqSizing(1).DesCoolingLoad
487
487
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -509,7 +509,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
509
509
printFlag = false ;
510
510
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
511
511
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
512
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
512
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
513
513
EXPECT_TRUE (sizer.wasAutoSized );
514
514
EXPECT_NEAR (5634.12 , sizedValue, 0.01 ); // capacity includes system fan heat
515
515
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -525,7 +525,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
525
525
printFlag = true ;
526
526
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
527
527
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
528
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
528
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
529
529
EXPECT_FALSE (sizer.wasAutoSized );
530
530
EXPECT_NEAR (4200.0 , sizedValue, 0.01 ); // hard sized capacity
531
531
sizer.autoSizedValue = 0.0 ; // reset for next test
@@ -561,7 +561,7 @@ TEST_F(AutoSizingFixture, CoolingCapacitySizingGauntlet)
561
561
printFlag = false ;
562
562
sizer.initializeWithinEP (*this ->state , HVAC::cAllCoilTypes (HVAC::Coil_CoolingWater), " MyWaterCoil" , printFlag, routineName);
563
563
sizedValue = sizer.size (*this ->state , inputValue, errorsFound);
564
- EXPECT_TRUE ( compare_enums ( AutoSizingResultType::NoError, sizer.errorType ) );
564
+ EXPECT_ENUM_EQ ( AutoSizingResultType::NoError, sizer.errorType );
565
565
EXPECT_TRUE (sizer.wasAutoSized );
566
566
EXPECT_NEAR (5633.933 , sizedValue, 0.01 ); // capacity includes system fan heat
567
567
sizer.autoSizedValue = 0.0 ; // reset for next test
0 commit comments