@@ -628,36 +628,44 @@ TEST_F(EnergyPlusFixture, RoomAirflowNetwork_CheckEquipName_Test)
628
628
EXPECT_EQ (" SupplyNode" , SupplyNodeName);
629
629
}
630
630
631
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode1" ;
632
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode1" ;
631
633
zoneEquipType = DataZoneEquipment::ZoneEquipType::EnergyRecoveryVentilator;
632
634
state->dataFans ->GetFanInputFlag = false ;
633
635
state->dataFans ->Fan .allocate (1 );
634
636
state->dataFans ->Fan (1 ).FanName = EquipName;
635
637
state->dataFans ->Fan (1 ).OutletNodeNum = 1 ;
636
638
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
637
639
if (check) {
638
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
640
+ EXPECT_EQ (" SupplyNode1 " , SupplyNodeName);
639
641
}
640
642
643
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode2" ;
644
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode2" ;
641
645
zoneEquipType = DataZoneEquipment::ZoneEquipType::FourPipeFanCoil;
642
646
state->dataFanCoilUnits ->FanCoil .allocate (1 );
643
647
state->dataFanCoilUnits ->FanCoil (EquipIndex).AirOutNode = 1 ;
644
648
state->dataFanCoilUnits ->FanCoil (EquipIndex).AirInNode = 2 ;
645
649
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
646
650
if (check) {
647
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
648
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
651
+ EXPECT_EQ (" SupplyNode2 " , SupplyNodeName);
652
+ EXPECT_EQ (" ReturnNode2 " , ReturnNodeName);
649
653
}
650
654
655
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode3" ;
656
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode3" ;
651
657
zoneEquipType = DataZoneEquipment::ZoneEquipType::OutdoorAirUnit;
652
658
state->dataOutdoorAirUnit ->OutAirUnit .allocate (1 );
653
659
state->dataOutdoorAirUnit ->OutAirUnit (EquipIndex).AirOutletNode = 1 ;
654
660
state->dataOutdoorAirUnit ->OutAirUnit (EquipIndex).AirInletNode = 2 ;
655
661
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
656
662
if (check) {
657
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
658
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
663
+ EXPECT_EQ (" SupplyNode3 " , SupplyNodeName);
664
+ EXPECT_EQ (" ReturnNode3 " , ReturnNodeName);
659
665
}
660
666
667
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode4" ;
668
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode4" ;
661
669
zoneEquipType = DataZoneEquipment::ZoneEquipType::PackagedTerminalAirConditioner;
662
670
UnitarySystems::UnitarySys thisUnit;
663
671
state->dataUnitarySystems ->unitarySys .push_back (thisUnit);
@@ -668,10 +676,12 @@ TEST_F(EnergyPlusFixture, RoomAirflowNetwork_CheckEquipName_Test)
668
676
state->dataUnitarySystems ->unitarySys [EquipIndex - 1 ].AirInNode = 2 ;
669
677
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
670
678
if (check) {
671
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
672
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
679
+ EXPECT_EQ (" SupplyNode4 " , SupplyNodeName);
680
+ EXPECT_EQ (" ReturnNode4 " , ReturnNodeName);
673
681
}
674
682
683
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode5" ;
684
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode5" ;
675
685
zoneEquipType = DataZoneEquipment::ZoneEquipType::PackagedTerminalHeatPump;
676
686
// UnitarySystems::UnitarySys thisUnit;
677
687
// state->dataUnitarySystems->unitarySys.push_back(thisUnit);
@@ -682,9 +692,11 @@ TEST_F(EnergyPlusFixture, RoomAirflowNetwork_CheckEquipName_Test)
682
692
state->dataUnitarySystems ->unitarySys [EquipIndex - 1 ].AirInNode = 2 ;
683
693
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
684
694
if (check) {
685
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
686
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
695
+ EXPECT_EQ (" SupplyNode5 " , SupplyNodeName);
696
+ EXPECT_EQ (" ReturnNode5 " , ReturnNodeName);
687
697
}
698
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode6" ;
699
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode6" ;
688
700
zoneEquipType = DataZoneEquipment::ZoneEquipType::PackagedTerminalHeatPumpWaterToAir;
689
701
// UnitarySystems::UnitarySys thisUnit;
690
702
// state->dataUnitarySystems->unitarySys.push_back(thisUnit);
@@ -695,47 +707,55 @@ TEST_F(EnergyPlusFixture, RoomAirflowNetwork_CheckEquipName_Test)
695
707
state->dataUnitarySystems ->unitarySys [EquipIndex - 1 ].AirInNode = 2 ;
696
708
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
697
709
if (check) {
698
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
699
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
710
+ EXPECT_EQ (" SupplyNode6 " , SupplyNodeName);
711
+ EXPECT_EQ (" ReturnNode6 " , ReturnNodeName);
700
712
}
701
713
714
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode7" ;
715
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode7" ;
702
716
zoneEquipType = DataZoneEquipment::ZoneEquipType::UnitHeater;
703
717
state->dataUnitHeaters ->UnitHeat .allocate (1 );
704
718
state->dataUnitHeaters ->UnitHeat (EquipIndex).AirOutNode = 1 ;
705
719
state->dataUnitHeaters ->UnitHeat (EquipIndex).AirInNode = 2 ;
706
720
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
707
721
if (check) {
708
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
709
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
722
+ EXPECT_EQ (" SupplyNode7 " , SupplyNodeName);
723
+ EXPECT_EQ (" ReturnNode7 " , ReturnNodeName);
710
724
}
711
725
726
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode8" ;
727
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode8" ;
712
728
zoneEquipType = DataZoneEquipment::ZoneEquipType::UnitVentilator;
713
729
state->dataUnitVentilators ->UnitVent .allocate (1 );
714
730
state->dataUnitVentilators ->UnitVent (EquipIndex).AirOutNode = 1 ;
715
731
state->dataUnitVentilators ->UnitVent (EquipIndex).AirInNode = 2 ;
716
732
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
717
733
if (check) {
718
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
719
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
734
+ EXPECT_EQ (" SupplyNode8 " , SupplyNodeName);
735
+ EXPECT_EQ (" ReturnNode8 " , ReturnNodeName);
720
736
}
721
737
738
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode9" ;
739
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode9" ;
722
740
zoneEquipType = DataZoneEquipment::ZoneEquipType::VentilatedSlab;
723
741
state->dataVentilatedSlab ->VentSlab .allocate (1 );
724
742
state->dataVentilatedSlab ->VentSlab (EquipIndex).ZoneAirInNode = 1 ;
725
743
state->dataVentilatedSlab ->VentSlab (EquipIndex).ReturnAirNode = 2 ;
726
744
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
727
745
if (check) {
728
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
729
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
746
+ EXPECT_EQ (" SupplyNode9 " , SupplyNodeName);
747
+ EXPECT_EQ (" ReturnNode9 " , ReturnNodeName);
730
748
}
731
749
750
+ state->dataLoopNodes ->NodeID (1 ) = " SupplyNode10" ;
751
+ state->dataLoopNodes ->NodeID (2 ) = " ReturnNode10" ;
732
752
zoneEquipType = DataZoneEquipment::ZoneEquipType::WindowAirConditioner;
733
753
state->dataWindowAC ->WindAC .allocate (1 );
734
754
state->dataWindowAC ->WindAC (EquipIndex).AirOutNode = 1 ;
735
755
state->dataWindowAC ->WindAC (EquipIndex).AirInNode = 2 ;
736
756
check = CheckEquipName (*state, EquipName, SupplyNodeName, ReturnNodeName, EquipIndex, zoneEquipType);
737
757
if (check) {
738
- EXPECT_EQ (" SupplyNode " , SupplyNodeName);
739
- EXPECT_EQ (" ReturnNode " , ReturnNodeName);
758
+ EXPECT_EQ (" SupplyNode10 " , SupplyNodeName);
759
+ EXPECT_EQ (" ReturnNode10 " , ReturnNodeName);
740
760
}
741
761
}