You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Copy file name to clipboardExpand all lines: docs/read_the_docs/source/changelog/changelog_dev.rst
+16Lines changed: 16 additions & 0 deletions
Original file line number
Diff line number
Diff line change
@@ -6,6 +6,22 @@ Development Changelog
6
6
:released: pending
7
7
8
8
.. change::
9
+
:tags: feature, characteristics
10
+
:pullreq: 1325
11
+
:tickets: resstock-estimation 437
12
+
13
+
**Date**: 2024-11-19
14
+
15
+
Title:
16
+
Well pump distribution using AHS
17
+
18
+
Description:
19
+
Use 2017-2019 AHS data to create Misc Well Pump distribution (~11% nationally) with respect to geography/urbanity, building type, and foundation type. Previously well pump was randomly assigned via a manually created distribution.
Copy file name to clipboardExpand all lines: docs/read_the_docs/source/workflow_inputs/characteristics.rst
+41-29Lines changed: 41 additions & 29 deletions
Original file line number
Diff line number
Diff line change
@@ -35182,7 +35182,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
35182
35182
- auto
35183
35183
- auto
35184
35184
* - None
35185
-
- 23%
35185
+
- 24%
35186
35186
- Percent
35187
35187
- 0
35188
35188
- 0
@@ -35342,7 +35342,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
35342
35342
- auto
35343
35343
- auto
35344
35344
* - None
35345
-
- 23%
35345
+
- 24%
35346
35346
- conditioned space
35347
35347
- auto
35348
35348
- auto
@@ -36374,13 +36374,13 @@ From ``project_national`` the list of options, option stock sturation, and optio
36374
36374
36375
36375
* - Mobile Home
36376
36376
- 6.2%
36377
-
* - Multifamily with 2-4 Units
36377
+
* - Multi-Family with 2 - 4 Units
36378
36378
- 8%
36379
-
* - Multifamily with 5+ units, 1-3 stories
36379
+
* - Multi-Family with 5+ Units, 1-3 Stories
36380
36380
- 13%
36381
-
* - Multifamily with 5+ units, 4-7 stories
36381
+
* - Multi-Family with 5+ Units, 4-7 Stories
36382
36382
- 3.4%
36383
-
* - Multifamily with 5+ units, 8+ stories
36383
+
* - Multi-Family with 5+ Units, 8+ Stories
36384
36384
- 2.1%
36385
36385
* - Single-Family Attached
36386
36386
- 5.9%
@@ -36688,7 +36688,7 @@ Assumption
36688
36688
36689
36689
- \Because we need to assume a foundation type for ground-floor MF units, we use the lumped SFD+SFA distributions for MF2-4 and MF5+ building foundations. (RECS data for households in MF2-4 unit buildings are not useful since we do not know which floor the unitis on. RECS does not include foundation responses for households in MF5+ unit buildings.)
36690
36690
36691
-
- \For SFD and SFA, if no foundation type specified, then sample has Ambient foundation.
36691
+
- \For Single-Family Detached, if no foundation type specified, then sample has Ambient foundation.
36692
36692
36693
36693
36694
36694
Arguments
@@ -38352,10 +38352,10 @@ From ``project_national`` the list of options, option stock sturation, and optio
38352
38352
- ``hvac_blower_fan_watts_per_cfm``
38353
38353
38354
38354
* - No
38355
-
- 23%
38355
+
- 24%
38356
38356
- auto
38357
38357
* - Yes
38358
-
- 77%
38358
+
- 76%
38359
38359
- auto
38360
38360
* - Void
38361
38361
- 0%
@@ -39253,7 +39253,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
39253
39253
- auto
39254
39254
- auto
39255
39255
* - Fuel Boiler, 76% AFUE
39256
-
- 0.83%
39256
+
- 0.89%
39257
39257
- Boiler
39258
39258
- 0.76
39259
39259
- auto
@@ -39298,7 +39298,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
39298
39298
- auto
39299
39299
- auto
39300
39300
* - Fuel Boiler, 80% AFUE
39301
-
- 3.2%
39301
+
- 3.3%
39302
39302
- Boiler
39303
39303
- 0.8
39304
39304
- auto
@@ -39343,7 +39343,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
39343
39343
- auto
39344
39344
- auto
39345
39345
* - Fuel Boiler, 90% AFUE
39346
-
- 0.48%
39346
+
- 0.49%
39347
39347
- Boiler
39348
39348
- 0.9
39349
39349
- auto
@@ -39613,7 +39613,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
39613
39613
- auto
39614
39614
- auto
39615
39615
* - Fuel Wall/Floor Furnace, 68% AFUE
39616
-
- 2.9%
39616
+
- 2.8%
39617
39617
- WallFurnace
39618
39618
- 0.68
39619
39619
- auto
@@ -39703,7 +39703,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
39703
39703
- auto
39704
39704
- auto
39705
39705
* - MSHP, SEER 29.3, 14 HSPF
39706
-
- 0.014%
39706
+
- 0.015%
39707
39707
- none
39708
39708
- 0
39709
39709
- auto
@@ -39993,7 +39993,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
39993
39993
* - Fuel Oil Fuel Furnace
39994
39994
- 2.8%
39995
39995
* - Fuel Oil Fuel Wall/Floor Furnace
39996
-
- 0.3%
39996
+
- 0.29%
39997
39997
* - Fuel Oil Shared Heating
39998
39998
- 0.51%
39999
39999
* - Natural Gas Fuel Boiler
@@ -40007,7 +40007,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
40007
40007
* - None
40008
40008
- 1.1%
40009
40009
* - Other Fuel Fuel Boiler
40010
-
- 0.45%
40010
+
- 0.46%
40011
40011
* - Other Fuel Fuel Furnace
40012
40012
- 0.24%
40013
40013
* - Other Fuel Fuel Wall/Floor Furnace
@@ -40023,7 +40023,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
40023
40023
* - Propane Shared Heating
40024
40024
- 0.16%
40025
40025
* - Void
40026
-
- 0%
40026
+
- 0.00039%
40027
40027
40028
40028
.. _hvac_secondary_heating_efficiency:
40029
40029
@@ -42236,7 +42236,7 @@ From ``project_national`` the list of options, option stock sturation, and optio
42236
42236
- 1.1%
42237
42237
- 3
42238
42238
* - 3 months
42239
-
- 0.35%
42239
+
- 0.36%
42240
42240
- 90
42241
42241
* - Never
42242
42242
- 96%
@@ -47656,17 +47656,29 @@ Misc Well Pump
47656
47656
Description
47657
47657
***********
47658
47658
47659
-
Presence and efficiency of well pump.
47659
+
Presence of well pump according to the use of well for domestic water source.
47660
47660
47661
47661
Created by
47662
47662
**********
47663
47663
47664
-
manually created
47664
+
``sources/ahs/ahs2017_2019/tsv_maker.py``
47665
47665
47666
47666
Source
47667
47667
******
47668
47668
47669
-
- \Wilson et al. 'Building America House Simulation Protocols' 2014, national average fraction used for saturation
47669
+
- \2017 and 2019 American Housing Survey (AHS) microdata.
47670
+
47671
+
- \Core Based Statistical Area (CBSA) data based on the Feb 2013 CBSA delineation file.
47672
+
47673
+
47674
+
Assumption
47675
+
**********
47676
+
47677
+
- \All well pumps are assumed to have typical efficiency.
47678
+
47679
+
- \Where the number of samples < 10, the Census Division is aggregated up to Census Region.
47680
+
47681
+
- \AHS has data for buildings up to 7 stories tall. Buildings with 8 or more stories are assumed not to have a well pump.
47670
47682
47671
47683
47672
47684
Arguments
@@ -47724,18 +47736,18 @@ From ``project_national`` the list of options, option stock sturation, and optio
Copy file name to clipboardExpand all lines: project_national/housing_characteristics/Geometry Building Type Height.tsv
+1-1Lines changed: 1 addition & 1 deletion
Original file line number
Diff line number
Diff line change
@@ -1,4 +1,4 @@
1
-
Dependency=Geometry Building Type RECSDependency=Geometry StoriesOption=Mobile HomeOption=Multifamily with 2-4 UnitsOption=Multifamily with 5+ units, 1-3 storiesOption=Multifamily with 5+ units, 4-7 storiesOption=Multifamily with 5+ units, 8+ storiesOption=Single-Family AttachedOption=Single-Family Detachedsource_countsource_weightsampling_probability
1
+
Dependency=Geometry Building Type RECSDependency=Geometry StoriesOption=Mobile HomeOption=Multi-Family with 2 - 4 UnitsOption=Multi-Family with 5+ Units, 1-3 StoriesOption=Multi-Family with 5+ Units, 4-7 StoriesOption=Multi-Family with 5+ Units, 8+ StoriesOption=Single-Family AttachedOption=Single-Family Detachedsource_countsource_weightsampling_probability
Copy file name to clipboardExpand all lines: project_national/housing_characteristics/Geometry Foundation Type.tsv
+1-1Lines changed: 1 addition & 1 deletion
Original file line number
Diff line number
Diff line change
@@ -517,4 +517,4 @@ Dependency=ASHRAE IECC Climate Zone 2004 Dependency=Geometry Building Type RECS
517
517
# Assumption: Single-family attached buildings cannot have Ambient foundations
518
518
# Assumption: Foundation types are the same for each building type except mobile homes and the applicable options.
519
519
# Assumption: Because we need to assume a foundation type for ground-floor MF units, we use the lumped SFD+SFA distributions for MF2-4 and MF5+ building foundations. (RECS data for households in MF2-4 unit buildings are not useful since we do not know which floor the unitis on. RECS does not include foundation responses for households in MF5+ unit buildings.)
520
-
# Assumption: For SFD and SFA, if no foundation type specified, then sample has Ambient foundation.
520
+
# Assumption: For Single-Family Detached, if no foundation type specified, then sample has Ambient foundation.
# Description: The heating fuel of the pool heater if there is a pool.
18
18
# Source: Constructed using U.S. EIA 2020 Residential Energy Consumption Survey (RECS) microdata.
19
19
# Source: Constructed using the California Energy Commision 2019 Residential Appliance Saturation Study (RASS) microdata.
20
-
# Assumption: Within electric pool heaters, proportion of heat pump electric pool heating vs. non-heat
21
-
# Assumption: pump electric pool heating was derived from RASS
20
+
# Assumption: Within electric pool heaters, proportion of heat pump electric pool heating vs. non-heat pump electric pool heating was derived from RASS 2019.
0 commit comments