From ff474e7e63c13f4977e5b9934959b86935b9969d Mon Sep 17 00:00:00 2001 From: Giulio Mazzoleni Date: Wed, 4 Mar 2026 15:28:54 +0100 Subject: [PATCH] Outdoor Lamp Controller: added additional number of counters and alarms - Control Gear overall failure condition counter - Control Gear external supply under voltage - Control Gear external supply under voltage counter - Control Gear external supply over voltage - Control Gear external supply over voltage counter - Control Gear output power limitation - Control Gear external output power limitation counter - Light Source overall failure condition counter - Dimming Curve Linearity --- 3416.xml | 94 +++- DDF.xml | 14 + version_history/3416_3_1.xml | 855 +++++++++++++++++++++++++++++++++++ 3 files changed, 961 insertions(+), 2 deletions(-) create mode 100644 version_history/3416_3_1.xml diff --git a/3416.xml b/3416.xml index 9c89e7e3f..ed5b54426 100644 --- a/3416.xml +++ b/3416.xml @@ -36,9 +36,9 @@ Outdoor lamp controller The uCIFI outdoor lamp controller object provides attributes to control, command and monitor outdoor luminaires in streets, in tunnels, on roads and for illumination of park and gardens. 3416 - urn:oma:lwm2m:ext:3416:3.0 + urn:oma:lwm2m:ext:3416:3.1 1.0 - 3.0 + 3.1 Multiple Optional @@ -719,6 +719,96 @@ bit 7: Sensor Ready Power Type: Apparent Energy]]> + + Control Gear overall failure condition counter + R + Single + Optional + Integer + + + + + + Control Gear external supply under voltage + R + Single + Optional + Boolean + + + + + + Control Gear external supply under voltage counter + R + Single + Optional + Integer + + + + + + Control Gear external supply over voltage + R + Single + Optional + Boolean + + + + + + Control Gear external supply over voltage counter + R + Single + Optional + Integer + + + + + + Control Gear output power limitation + R + Single + Optional + Boolean + + + + + + Control Gear external output power limitation counter + R + Single + Optional + Integer + + + + + + Light Source overall failure condition counter + R + Single + Optional + Integer + + + + + + Dimming Curve Linearity + RW + Single + Optional + Boolean + + + + Timestamp R diff --git a/DDF.xml b/DDF.xml index 2f37df9fb..c26217e72 100644 --- a/DDF.xml +++ b/DDF.xml @@ -3641,6 +3641,20 @@ Instances of this Object are linked from Instances of Object 0 using the OSCORE uCIFI 1 3.0 + version_history/3416-3_0.xml + + 1 + + 0 + + + 3416 + urn:oma:lwm2m:ext:3416:3.1 + Outdoor lamp controller + The uCIFI outdoor lamp controller object provides attributes to control, command and monitor outdoor luminaires in streets, in tunnels, on roads and for illumination of park and gardens. + uCIFI + 1 + 3.1 3416.xml 1 diff --git a/version_history/3416_3_1.xml b/version_history/3416_3_1.xml new file mode 100644 index 000000000..ed5b54426 --- /dev/null +++ b/version_history/3416_3_1.xml @@ -0,0 +1,855 @@ + + + + + Outdoor lamp controller + The uCIFI outdoor lamp controller object provides attributes to control, command and monitor outdoor luminaires in streets, in tunnels, on roads and for illumination of park and gardens. + 3416 + urn:oma:lwm2m:ext:3416:3.1 + 1.0 + 3.1 + Multiple + Optional + + + Command + RW + Single + Mandatory + Integer + 0..100 + /100 + + + + Command in action + R + Single + Optional + Integer + 0..100 + /100 + + + + Dimming level + R + Single + Mandatory + Integer + 0..100 + /100 + + + + Default dimming level + RW + Single + Optional + Integer + 0..100 + /100 + + + + Lamp failure + R + Single + Optional + Boolean + + + + + + Lamp failure reason + R + Single + Optional + Integer + + + + + + Control gear failure + R + Single + Optional + Boolean + + + + + + Control gear failure reason + R + Single + Optional + Integer + + + + + + Relay failure + R + Single + Optional + Boolean + + + + + + Day burner + R + Single + Optional + Boolean + + + + + + Cycling failure + R + Single + Optional + Boolean + + + + + + Control gear communication failure + R + Single + Optional + Boolean + + + + + + Lamp operating hours + R + Single + Optional + Float + + h + + + + Lamp operating hours reset + E + Single + Optional + + + + + + + Lamp ON timestamp + R + Single + Optional + Time + + + + + + Lamp switch counter + R + Single + Optional + Integer + + + + + + Lamp switch counter reset + E + Single + Optional + + + + + + + Control gear start counter + R + Single + Optional + Integer + + + + + + Control gear temperature + R + Single + Optional + Float + + Cel + + + + Control gear thermal derating + R + Single + Optional + Boolean + + + + + + Control gear thermal derating counter + R + Single + Optional + Integer + + + + + + Control gear thermal derating counter reset + E + Single + Optional + + + + + + + Control gear thermal shutdown + R + Single + Optional + Boolean + + + + + + Control gear thermal shutdown counter + R + Single + Optional + Integer + + + + + + Control gear thermal shutdown counter reset + E + Single + Optional + + + + + + + Output port + RW + Single + Optional + Integer + + + + + + Standby mode + RW + Single + Optional + Boolean + + + + + + Constant light output + RW + Single + Optional + Boolean + + + + + + Cleaning factor enabled + RW + Single + Optional + Boolean + + + + + + Cleaning period + RW + Single + Optional + Integer + + + + + + Initial lamp cleaning factor + RW + Single + Optional + Integer + 0..100 + /100 + + + + Lamp cleaning date + RW + Single + Optional + Time + + + + + + Control type + RW + Multiple + Optional + Integer + 0..13 + + + + + Nominal Lamp wattage + RW + Single + Optional + Integer + + W + + + + Minimum dimming level + RW + Single + Optional + Integer + + /100 + + + + Minimum lamp wattage + RW + Single + Optional + Integer + + W + + + + Light color temperature command + RW + Single + Optional + Integer + + K + + + + Actual light color temperature + R + Single + Optional + Integer + + K + + + + Virtual power output + RW + Single + Optional + Integer + 0..100 + /100 + + + + Voltage at max dim level + RW + Single + Optional + Float + + V + + + + Voltage at min dim level + RW + Single + Optional + Float + + V + + + + Light source voltage + R + Single + Optional + Float + + V + + + + Light source current + R + Single + Optional + Float + + A + + + + Light source active power + R + Single + Optional + Float + + W + + + + Light source active energy + R + Single + Optional + Float + + kWh + + + + Maximum light source current + RW + Single + Optional + Float + + A + + + + Default fade time + RW + Single + Optional + Float + + s + + + + Manual override start time + RW + Single + Optional + Time + + + + + + Manual override end time + RW + Single + Optional + Time + + + + + + Manual override fade + RW + Single + Optional + Float + + s + + + + Manual override default duration + RW + Single + Optional + Integer + + s + + + + Manual override active + R + Single + Optional + Boolean + + + + + + Default Light color temperature + RW + Single + Optional + Integer + + K + + + + Driver operating hours + R + Single + Optional + Float + + h + + + + Driver operating hours reset + E + Single + Optional + + + + + + + Manufacturer GTIN + R + Single + Optional + String + + + + + + Manufacturer Serial Number + R + Single + Optional + String + + + + + + Firmware Version + R + Single + Optional + String + + + + + + DALI Version + R + Single + Optional + String + + + + + + + Device capabilities + R + Single + Optional + Integer + + + + + + Lamp max operating hours threshold + RW + Single + Optional + Float + + h + + + + Lamp max operating hours exceeded + R + Single + Optional + Boolean + + + + + + Control Gear overall failure condition counter + R + Single + Optional + Integer + + + + + + Control Gear external supply under voltage + R + Single + Optional + Boolean + + + + + + Control Gear external supply under voltage counter + R + Single + Optional + Integer + + + + + + Control Gear external supply over voltage + R + Single + Optional + Boolean + + + + + + Control Gear external supply over voltage counter + R + Single + Optional + Integer + + + + + + Control Gear output power limitation + R + Single + Optional + Boolean + + + + + + Control Gear external output power limitation counter + R + Single + Optional + Integer + + + + + + Light Source overall failure condition counter + R + Single + Optional + Integer + + + + + + Dimming Curve Linearity + RW + Single + Optional + Boolean + + + + + + Timestamp + R + Single + Optional + Time + + + The timestamp of when the measurement was performed. + + + Fractional Timestamp + R + Single + Optional + Float + 0..1 + s + Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms). + + + Measurement Quality Indicator + R + Single + Optional + Integer + 0..23 + + Measurement quality indicator reported by a smart sensor. 0: UNCHECKED No quality checks were done because they do not exist or can not be applied. 1: REJECTED WITH CERTAINTY The measured value is invalid. 2: REJECTED WITH PROBABILITY The measured value is likely invalid. 3: ACCEPTED BUT SUSPICIOUS The measured value is likely OK. 4: ACCEPTED The measured value is OK. 5-15: Reserved for future extensions. 16-23: Vendor specific measurement quality. + + + Measurement Quality Level + R + Single + Optional + Integer + 0..100 + + Measurement quality level reported by a smart sensor. Quality level 100 means that the measurement has fully passed quality check algorithms. Smaller quality levels mean that quality has decreased and the measurement has only partially passed quality check algorithms. The smaller the quality level, the more caution should be used by the application when using the measurement. When the quality level is 0 it means that the measurement should certainly be rejected. + + + + +