var Logger = require('./utils/logger');
var configurator = require('devjs-configurator');
var FunctionCode = require('./src/l4-functionCode');
var ModbusRTU = require('./src/modbusRTU');
var Scheduler = require('./src/scheduler');
var logger = new Logger( {moduleName: 'Driver', color: 'bgGreen'} );
//---------------------------------------------------------------------
configurator.configure("ModbusRTU",__dirname).then(function(data) {
var options = data;
var scheduler;
var modbus;
var functionCode;
//Set loglevel
global.GLOBAL.ModbusLogLevel = options.logLevel || 2;
logger.info('Starting with options ' + JSON.stringify(options));
options.serialInterfaceOptions.onPortClose = function() {
modbus._state = false;
if(scheduler) {
scheduler.stop();
}
};
options.serialInterfaceOptions.onPortReconstruct = function() {
modbus._state = true;
if(scheduler) {
scheduler.start(modbus, functionCode);
}
};
function startModbus() {
functionCode = new FunctionCode();
functionCode.start(options).then(function() {
modbus = new ModbusRTU(options.modbusResourceId || "ModbusDriver");
scheduler = new Scheduler(options);
scheduler.start(modbus, functionCode);
modbus.start({
fc: functionCode,
resourceTypesDirectory: options.supportedResourceTypesDirectory || "controllers/supportedResourceTypes",
runtimeDirectory: options.runtimeResourceTypesDirectory || "controllers/runtimeResourceTypes",
scheduler: scheduler,
siodev: options.serialInterfaceOptions.siodev,
relayId: options.relayId
}).then(function() {
logger.info('Modbus RTU controller started successfully with ID ' + options.modbusResourceId);
//Instantiate available resource types
modbus.commands.startAll().then(function() {
logger.info('Started device controller on all supported resource types');
modbus._state = true;
}, function(err) {
logger.error('Failed to start device controllers ' + JSON.stringify(err) + err);
});
}, function(err) {
logger.error('Could not start modbus controller ' + (err.stack || JSON.stringify(err)));
if(err.status == 500) {
logger.error('Check the modbusResourceId in config.json, we already have one controller running with the specified id. Change the id and try again!');
}
});
});
}
startModbus();
}, function(err) {
logger.error('Unable to load ModbusRTU config.json, ' + err);
return;
});