PAL16L8
JLB/CJTC 14AUG86
44302B,11D,LBC1
/Q0 /Q2 /CC2 /BDRY25 /BDRY50 /CGNT /CGNT50 /CACT /TERM GND
/BGNT /CGNTCACT /RT /IORQ TEST NC16 /DSTB /EMD /BGNTCACT VCC
IF (/TEST) EMD = Q2 * QO * CACT ; CPU CYCLE TO BUS SET
+ EMD * CACT 1 ; " HOLD
+ CGNT * CGNTSO ; CPU CYCLE TO MEM SET
+ EMD * RT * CC2 * /TERM ; ) HOLD TERMS FOR
+ EMD * IORQ * CC2 * /TERM ; ) CPU READ, FETCH AND
; ) MAP CYCLES
IF (/TEST) CGNTCACT = CGNT + CACT
IF (/TEST) BGNTCACT = BGNT + CACT
IF (/TEST) DSTB = CGNT + CACT * /BDRY50 * /BDRY25 * /IORQ
+ CACT * IORQ * CC2 ; IOX CYCLE
DESCRIPTION
; 060387 JLB: EMD WAS HOLDING IN ADDRESS PART OF IOX CYCLES AFTER
; BUFFERED WRITE CYCLES.
; EMD - ENABLE DATA PATH BETWEEN CD AND LBD
; 270387 CJTC: NEW SIGNAL DSTB TO SAMPLE DATA AT LBD/CD BUFFERS ON
; CPU FROM BUS READ, AT BDRY.
; 040487 JLB: DSTB MUST NOT CLOCK DATA BEFORE CACT GOES OFF IN IOXES.
; (NEGATIVE SETUP OF DATA IN BUS SPECS.)
;
; 180587 CJTC: 3202B