Skip to content

Support SHORT_STRING data type for symbolic tag messaging #65

@greg9504

Description

@greg9504

The SHORT_STRING data type is a single byte character string. It is sent with the first byte being the length, followed by the string data. Supporting symbolic (Rockwell) tags with this data type is relatively straightforward. Also add support for USINT (unsigned 8bit data) Code changes here:

https://github.com/greg9504/ST-node-ethernet-ip/tree/Add_Additional_DataTypes_Support

There was also a change for writing SINT data, the code used Buffer.writeUInt8 when I think it should have used Buffer.writeInt8.

Further testing should probably be done, as I've only be able to test using the Micro850 simulator in Connected Components Workbench.

Tested with
CCW version 22
PLC - 2080-LC50-48QWB-SIM (Micro850 Simulator, not actual hardware)

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions