P110, error 52, Since the firmware update yesterday. #27

Closed
Heisenberg2018 opened this issue Dec 1, 2023 · 15 comments
Closed

P110, error 52, Since the firmware update yesterday. #27

Heisenberg2018 opened this issue Dec 1, 2023 · 15 comments

Comments

@Heisenberg2018
Copy link

Describe the bug
Since the firmware update yesterday, my Tapo p110 only gets error 52 in iobroker and cannot connect.

To Reproduce
Happened with the firmware update:
Tapo P110(EU)_V1_1.3.0 Build 230905

Expected behavior
I already thought that there were problems because the firmware also indicated changes to the login security in the changelog

Screenshots & Logfiles
2023-12-01 11:37:21.572 error 52 - Get Device Info failed

Versions:
Adapter:
0.2.0

Additional context
It looks like TP-Link is currently patching all WLAN devices, and it looks like you have to rework the adapter for every device that has the new update!?

@OberstVonGatow
Copy link

Same here also get this error for my P110 with the latest firmware.
I also tried the latest GitHub Version with the same result.

@Heisenberg2018
Copy link
Author

I think that all tapo devices had a security gap, and all devices that have a firmware where the changelog says that the login has been fixed must be renewed in the adapter.

What I just find strange is that if a Tapo device has not yet been replaced in the adapter, all other devices don't really work at that time. 🤷🏻

@OberstVonGatow
Copy link

What do you mean with "must be renewed in the adapter"? I restarted and reinstalled the adapter with new Login and MFA but still get there Error.

And you were right one of my p110 still had an old Firmware.

I also have a old HS110 connected with the tapo App but don't think that should be an issue.

@Heisenberg2018
Copy link
Author

What I mean by this is that the dev probably has to change something on the adapter for each device that receives the firmware update with the new login.

@Heisenberg2018
Copy link
Author

Is there any news about an adapter update?

@Hant0r
Copy link

Hant0r commented Dec 7, 2023

If you also have this problem, please like the first post. That way, not everyone has to comment here that they are also affected and the developer can quickly see how urgent it is

@TA2k
Copy link
Owner

TA2k commented Dec 7, 2023

I waiting for homebridge implementation that they fixing this

@Uwe4313
Copy link

Uwe4313 commented Dec 8, 2023

Tapo P115 Nano Plug is also affected.

@ad2012
Copy link

ad2012 commented Dec 10, 2023

Seems to be fixed but waiting for pull... apatsufas/homebridge-tapo-p100#47

@Heisenberg2018
Copy link
Author

Is there no more update coming?

@padman74
Copy link

I'm also waiting. Or is there any other option to get the power consumption into IOBroker?

@Heisenberg2018
Copy link
Author

I would also be interested in a solution because suddenly and unexpectedly the responsible developer is apparently no longer active after 10 years. I have the feeling that nothing is happening anymore and that's why I need a replacement solution.

@TA2k
Copy link
Owner

TA2k commented Dec 28, 2023

As mentioned still waiting for the homebridge fix

@MaPaSoTo
Copy link

hmm, not sure. Still have this problem. Is it fixed or do we still wait?

@Heisenberg2018
Copy link
Author

The sockets are working again Update to the latest GitHub version.