selected_site: 'br' # choose instrument defined below
refreshrate: 3 # refreshrate of the measurements in sec. It might not make sense to go too low, due to length of measurement and computational constraints
cutoff: 3700 # cm-1 , upper limit of low pass for smoothing the ifg
smoothing: 'hann' # or 'fft' ; method used to produce the smoothed ifg
lwn: 15798.022 # cm-1 , laser wavenumber
spc_plot_xlim: [3000, 11000]
# removed, automatically display only +- npt/2 around zpd
#zpd_interval: [1700, 2300] # zoom to this index interval for zpd
npt: 2000 # number of ifg points to be used around zpd
fitwindowsize: 200 # number of points around zpd to fit smoothed ifg for dip calculation
blockzpd: 40 # number of points to block out dip to fit baseline in smoothed ifg
br: {
ip: '10.10.0.1', # ip of the ifs
# the preview command can be obtained from Opus: While running Check signal in the preferred preview mode, check menu Measure -> Optis Setup & Service -> Optic Communications and copy-paste the relevant command series here
preview_commands: #'cmd.htm?WRK=3&AMD=7&UWN=1&ITC=0&CNM=Default&SNM=Bremen&SFM=cm%2d1%204000%2e0%2011000%2e0%20cm%2d1&DLY=0&DEL=0&RES=14.216020&SRC=104&LPF=10.0&HPF=0&BMS=1&APT=0x2710&DTC=0x4041&VEL=10.0&AQM=0x4e44&HFW=15788.022000&LFW=10.000000&PHR=14.216020&SON=0&PGN=3&OPF=4&OF3=1&ADC=0&CMA=0&COR=0&CHN=1&SOT=0&NSS=1&RDX=0&TSR=0&GNS=1&REP=1&DLR=0',
'cmd.htm?WRK=3&AMD=7&UWN=0&ITC=0&CNM=Default&SNM=Bremen&SFM=cm%2d1%204000%2e0%2011000%2e0%20cm%2d1&DLY=0&DEL=0&RES=14.216020&SRC=104&LPF=10.0&HPF=0&BMS=1&APT=0x1F40&DTC=0x4041&VEL=10.0&AQM=0x4e44&HFW=15788.022000&LFW=10.000000&PHR=14.216020&SON=0&PGN=3&OPF=8&OF3=5&ADC=0&CMA=0&COR=0&CHN=1&SOT=0&NSS=1&RDX=0&TSR=0&GNS=1&REP=1&DLR=0',
# APT=500 : 0.5 mm
# APT=800 : 0.8 mm
# APT=0x03E8 : 1 mm
# APT=0x047E : 1.15 mm
# APT=0x0514 : 1.3 mm
# APT=0x05DC : 1.5 mm
# APT=0x06A4 : 1.7 mm
# APT=0x07D0 : 2 mm
# APT=0x09C4 : 2.5 mm
# APT=0x0C4E : 3.15 mm
# APT=0x0FA0 : 4 mm # lamp image too small
# APT=0x1388 : 5 mm # lamp image too small
# APT=0x189C : 6.3 mm # lamp image too small
# APT=0x1F40 : 8 mm # lamp image too small
# APT=0x2710 : 10 mm # lamp image too small
#
# shutdown commands will be sent to instrument, but no response is displayed when pressing 'Stop Measurement'. Use e.g. to switch off lamp, etc.
shutdown_commands: 'cmd.htm?WRK=3&AMD=7&UWN=1&ITC=0&CNM=Default&SNM=Bremen&SFM=cm%2d1%204000%2e0%2011000%2e0%20cm%2d1&DLY=0&DEL=0&RES=14.216020&SRC=0&LPF=10.0&HPF=0&BMS=1&APT=0x03E8&DTC=0x4041&VEL=10.0&AQM=0x4e44&HFW=15788.022000&LFW=10.000000&PHR=14.216020&SON=0&PGN=3&OPF=4&OF3=1&ADC=0&CMA=0&COR=0&CHN=1&SOT=0&NSS=1&RDX=0&TSR=0&GNS=1&REP=1&DLR=0',
}
# feel free to add additional sites here, keys need to be the same as above