PLIC

Use piecewise linear interface calculation (PLIC) for the reconstruction of the fluid interface from volume of fluid (VOF) fields.

Input

The following input ports are available:

Input Description Type Remark
Grid Grid containing a volume of fluid field. Rectilinear Grid

Grid

The grid contains the following data fields:

Data field Description Data Type Remark
Volume of fluid field A volume of fluid field, whose entries are in the range [0, 1]. Scalar Cell-based
Interface gradients Gradients in interface cells. Vector Cell-based Optional. If not given, the gradients are computed by the filter itself.

Parameters

The following parameters can be set by the user:

Parameter Description Type Accepted values Default value
Number of iterations Number of iterations for the iterative approximation of the interface. Integer >0 15
Perturbation of vertices Perturbation on the input vertices to prevent degenerate cases, which often occur in the initial time steps of the simulation. Double ≥0 1e-5

Output

The output is a polygonal mesh, for which the following data fields are provided:

Data field Description Data Type Remark
Error Error, defined as difference between input volume of fluid and volume enclosed by the reconstructed interface. Scalar Cell-based This field is only available when setting the TPF debug flag.