In addition to common configuration parameters described in README.md
in the top directory, following parameters can be specified.
config
intvl_expand
Interval of time step for expanding the box size in x direction.
parameter
:num_process
Number of MPI processes. This must be the same as the number specified
in execusion withmpiexec
ormpirun
.n_ppc
Number of particle per cell in the upstream region.n_x
Number of grid in x direction.n_y
Number of grid in y direction.n_x_ini
Initial number of grid in x direction. The simulation box will expand
everyintvl_expand
step.u_injection
Injection four-velocity from the boundary.mass_ratio
Ion to electron mass ratio: m_i/m_e.sigma_e
Ratio of electron cyclotron-to-plasma frequency squared.omega_pe
Proper plasma frequency in the upstream.v_thi
Thermal velocity of ions in the upsteram.v_the
Thermal velocity of electrons in the upsteram.theta_bn
Magnetic obliquity in the upstream or the shock angle in degrees.phi_bn
Magnetic field orientation in the upstream with respect to the
simulation plane in degrees. The in-plane and out-of-plane magnetic
field configurations correspond to 0 and 90, respectively.l_damp_ini
Length scale for the initial velocity profile in unit of grid size.
This is to smooth out initial disturbances and nothing physical.
For a quicklook, run the script plot_sample.py
as
$ python plot_sample.py