-
Notifications
You must be signed in to change notification settings - Fork 14
/
Copy pathHIKVISION-MIB.mib
318 lines (272 loc) · 7.55 KB
/
HIKVISION-MIB.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
HIKVISION-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter
FROM RFC1155-SMI
enterprises, OBJECT-TYPE, NetworkAddress
FROM SNMPv2-SMI
DisplayString FROM SNMPv2-TC
;
hikvision OBJECT IDENTIFIER ::= { enterprises 50001 }
hikEntity OBJECT IDENTIFIER ::= { hikvision 1 }
-- hikvision persistent property
hikIp OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"hikvision device valid ip address"
::= { hikEntity 1 }
hikPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"hikvision device valid manager port,default is 8000"
::= { hikEntity 2 }
hikEntityIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"hikvision device unique index, for DVR this is serial NO."
::= { hikEntity 3 }
hikEntityType OBJECT IDENTIFIER ::= { hikEntity 100 }
hikEntityType OBJECT-TYPE
SYNTAX INTEGER {
dvr(1),
nvr(2),
ipc(3),
unknown(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"hikvision products type"
::= { hikEntity 100 }
hikEntitySubType OBJECT-TYPE
SYNTAX INTEGER {
dvr-70xx(1),
dvr-71xx(2),
dvr-80xx(20),
dvr-81xx(21),
dvr-90xx(40),
dvr-91xx(41),
nvr(200),
ipc(400),
unknown(65535)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"hikvision product sub type"
::= { hikEntity 101 }
hikOnline OBJECT-TYPE
SYNTAX INTEGER {
online(1),
absent(2),
unknown(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product online status"
::= { hikEntity 102 }
hikService OBJECT-TYPE
SYNTAX INTEGER {
unknown(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product service type, now dvr will return Unknown"
::= { hikEntity 103 }
hikCMSDefType OBJECT-TYPE
SYNTAX INTEGER {
unknown(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product defined CMS type, now dvr will return Unknown"
::= { hikEntity 104 }
hikObjectID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product object ID, now dvr do not need this will return 0"
::= { hikEntity 105 }
hikObjectName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product object Name, now dvr do not need this will return nothing"
::= { hikEntity 106 }
hikTrapHostIp1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product 1st trap host ip address "
::= { hikEntity 110}
--hik cpu info
hikCPUNum OBJECT-TYPE
SYNTAX INTEGER(1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of hikvision product's cpu "
::= { hikEntity 200}
hikCPUFrequency OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the frequency of hikvision product's cpu, format like 2000MHZ "
::= { hikEntity 201}
--hik memery info
hikMemoryCapability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the size of Memory"
::= { hikEntity 220}
hikMemoryUsage OBJECT-TYPE
SYNTAX INTEGER(0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the Usage of hikvision product's Memory, value scope is (0-100)"
::= { hikEntity 221}
hikDeviceStatus OBJECT-TYPE
SYNTAX INTEGER{
online(1),
absent(2),
unknown(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product status"
::= { hikEntity 230}
hikDeviceLanguage OBJECT-TYPE
SYNTAX INTEGER{
english(1),
simple-chinese(2),
traditional-chinese(3),
japanese(4),
korea(5),
unknown(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"display hikvision product language"
::= { hikEntity 231}
-- hikvision disk info --
hikDiskNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of hikvision device local disks"
::= { hikEntity 240}
-- the disk table
hikDiskTable OBJECT-TYPE
SYNTAX SEQUENCE OF HikDiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of disk entries. The number of
entries is given by the value of hikDiskNum."
::= { hikEntity 241 }
hikDiskEntry OBJECT-TYPE
SYNTAX HikDiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A disk entry containing objects at local disk status."
INDEX { hikDiskIndex }
::= { hikDiskTable 1 }
HikDiskEntry ::=
SEQUENCE {
hikDiskIndex
INTEGER,
hikDiskVolume
DisplayString,
hikDiskStatus
INTEGER,
hikDiskFreeSpace
INTEGER,
hikDiskCapability
INTEGER
}
hikDiskIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An unique value for each local disk entry. Its value
ranges between 1 and the value of ifNumber."
::= { hikDiskEntry 1 }
hikDiskVolume OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual string containing information about local
disk"
::= { hikDiskEntry 2 }
hikDiskStatus OBJECT-TYPE
SYNTAX INTEGER{
normal(0),
unformatted(1),
abnormal(2),
smartfailed(3),
mismatch(4),
idle(5),
notonline(6),
reparing(10),
formatting(11)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"local disk status"
::= { hikDiskEntry 3 }
hikDiskFreeSpace OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the size of local disk entry free space,
if we get 100, means free space is 100M"
::= { hikDiskEntry 4 }
hikDiskCapability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the size of local disk entry all space,
if we get 100, means all space is 100M"
::= { hikDiskEntry 5 }
-- hikvisoin trap define
--power status trap
power-PowerOn TRAP-TYPE
ENTERPRISE hikvision
DESCRIPTION
"hikvision device power on"
::= 1
power-PowerOff TRAP-TYPE
ENTERPRISE hikvision
DESCRIPTION
"hikvision device shut down"
::= 2
power-ReBoot TRAP-TYPE
ENTERPRISE hikvision
DESCRIPTION
"hikvision device reboot"
::= 3
END