"modbusError": false, // (Boolean) Was there a problem reading from the charge controller?
"controller": {
"chargingMode": "FLOAT", // Charging mode being used right now.
"temperature": 21, // (*C) Controller internal temperature.
"days": 1002, // Lifetime count of the number of days the charge controller has been operational.
"overDischarges": 6, // Lifetime count of times the batteries were over-discharged.
"fullCharges": 1477 // Lifetime count of times the batteries wre fully charged
},
"charging": {
"amps": 2.58, // (A) Amp reading from charge controller to battery right now.
"maxAmps": 8.46, // (A) Highest amp reading from charge controller to battery seen today.
"watts": 76, // (W) Power generation right now.
"maxWatts": 251, // (W) Highest power generation seen today.
"dailyAmpHours": 25, // (Ah) Amp hours generated today.
"totalAmpHours": 51.734, // (kAh) Lifetime amp hours generated.
"dailyPower": 0.715, // (kWh) Power generated today.
"totalPower": 1404.9 // (kWh) Lifetime power generated.
},
"battery": {
"stateOfCharge": 100, // (%) Battery state of charge.
"volts": 28.2, // (V) Battery voltage reading right now.
"minVolts": 24.4, // (V) Minimum battery voltage seen today.
"maxVolts": 29.9, // (V) Maximum battery voltage seen today.
"temperature": 11 // (*C) Battery temperature measured by attached probe.
},
"panels": {
"volts": 86.1, // (V) Voltage reading from panels to charge controller.
"amps": 0.88 // (A) Amp reading from panels to charge controller.
},
"load": {
"state": true, // (Boolean) Load state.
"volts": 28.2, // (V) Load voltage reading right now.
"amps": 0, // (A) Load amp reading right now.
"watts": 0, // (W) Load power draw right now.
"maxAmps": 0, // (A) Highest load amp reading seen today.
"maxWatts": 0, // (W) Highest load power draw seen today.
"dailyAmpHours": 0, // (Ah) Load amp hours used today.
"totalAmpHours": 0.001, // (kAh) Lifetime load amp hours.
"dailyPower": 0, // (kWh) Load power used today.
"totalPower": 0.024 // (kWh) Lifetime load power consumption.
},
"faults": [ // List of faults currently being reported by the controller.
"Charge MOS short circuit",
"Anti-reverse MOS short",
"PV panel reversely connected",
"PV working point over voltage",
"PV counter current",
"PV input side over-voltage",
"PV input side short circuit",
"PV input overpower",
"Ambient temp too high",
"Controller temp too high",
"Load over-power/current",
"Load short circuit",
"Battery undervoltage warning",
"Battery overvoltage",
"Battery over-discharge"
]
}