This page provides an overview per manufacturer of the ZigBee Devices connected to my Hue bridge, as reported by deCONZ. It lists the endpoints and clusters per device. Server clusters are in boldface.
I joined my RaspBee to the ZigBee network created by my Hue bridge and, after that, these devices where discovered automatically by deCONZ.
TODO:
- Try an make the RaspBee join a ZigBee network created by an Osram Lightify gateway.
- Double check that the Lightify Gateway has FC0F and 0B04 client clusters for Device Setup and Electrical Measurement.
- Try and make the RaspBee join a ZigBee network created by an innr gateway.
Here's the configuration for a second-generation Hue bridge:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
F2 | ZGP | 0061 unknown | |
0021 | ZigBee Green Power Proxy | ||
40 | ZLL | Control Bridge | |
1000 | ZLL Commissioning | ||
0019 | OTAU | ||
1000 | ZLL Commissioning | ||
0004 | Groups | ||
0005 | Scenes | ||
0000 | Basic | ||
0300 | Color Control | ||
0008 | Level Control | ||
0006 | On/Off | ||
41 | ZHA | Combined Interface | |
000F | Binary Input (Basic) | ||
0406 | Occupancy Sensing | ||
0402 | Temperature Measurement | ||
0405 | Humidify Measurement | ||
FC00 | ? Device Setup | ||
0400 | Illuminance Measurement |
Notes:
- So the Hue bridge does talk ZHA?!
- I suspect the Binary Input (Basic) is used for the
buttonevent
of the Hue dimmer switch. - Apparently Philips planned for a ZigBee version of the CLIPHumidity sensor? But no ZigBee version of the CLIPOpenClose sensor?
- The Hue dimmer switch has a corresponding server for the FC00 cluster. Could it be for keeping track which lights are connected to the dimmer switch using touchlink? When connecting a previously standalone dimmer switch to a Hue bridge (using the Hue app), the bridge can "inherit" the lights from the dimmer switch.
Here's the configuration for a Hue Extended Color Light:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
02 | ZLL | Extended Color Light | |
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
1000 | ZLL Commissioning | ||
0019 | OTAU | ||
F2 | ZGP | 0061 unknown | |
0021 | ZigBee Green Power Sink | ||
0021 | ZigBee Green Power Proxy |
Notes:
- A Hue Color Light and a Hue Color Temperature Lights have the same configuration. So does a Hue Dimmable Light, except that, of course, it misses the Color Control cluster.
Here's the configuration for a Hue motion sensor:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
02 | ZHA | Occupancy Sensor | |
0000 | Basic | ||
0001 | Power Configuration | ||
0003 | Identify | ||
0406 | Occupancy Sensing | ||
0400 | Illuminance Measurement | ||
0402 | Temperature Measurement | ||
0019 | OTAU | ||
01 | ZLL | On/Off Sensor | |
0000 | Basic | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
0005 | Scenes |
Notes:
- So the Hue motion sensor does talk ZHA?!
- The 01 endpoint seems to suggest it could work standalone, without a Hue bridge, like the Hue dimmer switch?!
Here's the configuration for a Hue dimmer switch:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZLL | Non-Color-Scene Controller | |
0000 | Basic | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
02 | ZHA | 000C | |
0000 | Basic | ||
0001 | Power Configuration | ||
0003 | Identify | ||
000F | Binary Input (Basic) | ||
FC00 | ? Device Setup | ||
0019 | OTAU |
Notes:
- So the Hue dimmer switch does talk ZHA?!
- deCONZ seems to have troubles communicating with the dimmer switches. Of my six dimmer switches, only two are reporting in the web interface; two show grey, but trying to read attributes through Cluster Info does nothing; two show red and don't even list the discovered endpoints and clusters.
- The Scenes cluster is missing from one of my dimmers, which reports as a Non-Color Controler device. Not sure if this is due to a deCONZ communication error or different firmware?
- I suspect the Binary Input (Basic) is used for
buttonevent
. - The Hue bridge has a corresponding client for the FC00 cluster.
The Hue tap doesn't show in the deCONZ gui.
Here's the configuration for an Osram E14 bulb:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
03 | ZLL | Color Temperature Light | |
1000 | ZLL Commissioning | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
FC0F | ? Device Setup | ||
0019 | OTAU |
Notes:
- No support for ZGP proxy.
- I suspect OSRAM use the FC0F cluster for setting the power-on default.
Here's the configuration for an Osram plug:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
03 | ZLL | On/Off Plug-In Unit | |
1000 | ZLL Commissioning | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0B04 | ? Electrical Measurement | ||
0019 | OTAU |
Notes:
- I don't remember seeing some Electrical Measurement features in the OSRAM Lightly app.
Here's the configuration for an innr RB 162 dimmable light:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZLL | Dimmable Light | |
0000 | Basic | ||
0004 | Groups | ||
0003 | Identify | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
02 | ZLL | 1000 unknown | |
1000 | ZLL Commissioning |
Notes:
- Indeed, no over-the-air update for the firmware as innr support had indicated.
- deCONZ seems to have problems communicating with these lights. They show red after a while in the deCONZ gui. When trying to send a command (from cluster info), deCONZ reports sending failed.
Here's the configuration for an innr PL 110 or UC 110, which use the same control box:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZLL | Dimmable Light | |
0000 | Basic | ||
0004 | Groups | ||
0003 | Identify | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
FFFF | ? | ||
0019 | OTAU | ||
0000 | Basic | ||
0004 | Groups | ||
0003 | Identify | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
0019 | OTAU |
- Huh, support for over-the-air update for the firmware?
- Huh, no ZLL Commissioning? Maybe that's why these aren't listed under certified devices on the ZigBee alliance website?
- I've no clue about the FFFF cluster.
- The box seems to be configurable as a ZigBee control device as well. It does contain an unused header. Maybe innr uses the same board for their gateway?
- deCONZ seems to have problems communicating with these control boards. They show red after a while in the deCONZ gui. When trying to send a command (from cluster info), deCONZ reports sending failed.