-
Notifications
You must be signed in to change notification settings - Fork 292
/
check-lte-firmware-upgrade.rsc
103 lines (87 loc) · 3.86 KB
/
check-lte-firmware-upgrade.rsc
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
#!rsc by RouterOS
# RouterOS script: check-lte-firmware-upgrade
# Copyright (c) 2018-2024 Christian Hesse <mail@eworm.de>
# https://git.eworm.de/cgit/routeros-scripts/about/COPYING.md
#
# requires RouterOS, version=7.14
#
# check for LTE firmware upgrade, send notification
# https://git.eworm.de/cgit/routeros-scripts/about/doc/check-lte-firmware-upgrade.md
:global GlobalFunctionsReady;
:while ($GlobalFunctionsReady != true) do={ :delay 500ms; }
:do {
:local ScriptName [ :jobname ];
:global SentLteFirmwareUpgradeNotification;
:global ScriptLock;
:if ([ $ScriptLock $ScriptName ] = false) do={
:error false;
}
:if ([ :typeof $SentLteFirmwareUpgradeNotification ] != "array") do={
:global SentLteFirmwareUpgradeNotification ({});
}
:local CheckInterface do={
:local ScriptName $1;
:local Interface $2;
:global Identity;
:global SentLteFirmwareUpgradeNotification;
:global FormatLine;
:global IfThenElse;
:global LogPrint;
:global ScriptFromTerminal;
:global SendNotification2;
:global SymbolForNotification;
:local IntName [ /interface/lte/get $Interface name ];
:local Firmware;
:local Info;
:do {
:set Firmware [ /interface/lte/firmware-upgrade $Interface as-value ];
:set Info [ /interface/lte/monitor $Interface once as-value ];
} on-error={
$LogPrint debug $ScriptName ("Could not get latest LTE firmware version for interface " . \
$IntName . ".");
:return false;
}
:if ([ :len ($Firmware->"latest") ] = 0) do={
$LogPrint info $ScriptName ("An empty string is not a valid version.");
:return false;
}
:if (($Firmware->"installed") = ($Firmware->"latest")) do={
:if ([ $ScriptFromTerminal $ScriptName ] = true) do={
$LogPrint info $ScriptName ("No firmware upgrade available for LTE interface " . $IntName . ".");
}
:return true;
}
:if ([ $ScriptFromTerminal $ScriptName ] = true && \
[ :len [ /system/script/find where name="unattended-lte-firmware-upgrade" ] ] > 0) do={
:put ("Do you want to start unattended lte firmware upgrade for interface " . $IntName . "? [y/N]");
:if (([ /terminal/inkey timeout=60 ] % 32) = 25) do={
/system/script/run unattended-lte-firmware-upgrade;
$LogPrint info $ScriptName ("Scheduled lte firmware upgrade for interface " . $IntName . "...");
:return true;
} else={
:put "Canceled...";
}
}
:if (($SentLteFirmwareUpgradeNotification->$IntName) = ($Firmware->"latest")) do={
$LogPrint debug $ScriptName ("Already sent the LTE firmware upgrade notification for version " . \
($Firmware->"latest") . ".");
:return false;
}
$LogPrint info $ScriptName ("A new firmware version " . ($Firmware->"latest") . " is available for " . \
"LTE interface " . $IntName . ".");
$SendNotification2 ({ origin=$ScriptName; \
subject=([ $SymbolForNotification "sparkles" ] . "LTE firmware upgrade"); \
message=("A new firmware version " . ($Firmware->"latest") . " is available for " . \
"LTE interface " . $IntName . " on " . $Identity . ".\n\n" . \
[ $IfThenElse ([ :len ($Info->"manufacturer") ] > 0) ([ $FormatLine "Manufacturer" ($Info->"manufacturer") ] . "\n") ] . \
[ $IfThenElse ([ :len ($Info->"model") ] > 0) ([ $FormatLine "Model" ($Info->"model") ] . "\n") ] . \
[ $IfThenElse ([ :len ($Info->"revision") ] > 0) ([ $FormatLine "Revision" ($Info->"revision") ] . "\n") ] . \
"Firmware version:\n" . \
[ $FormatLine " Installed" ($Firmware->"installed") ] . "\n" . \
[ $FormatLine " Available" ($Firmware->"latest") ]); silent=true });
:set ($SentLteFirmwareUpgradeNotification->$IntName) ($Firmware->"latest");
}
:foreach Interface in=[ /interface/lte/find ] do={
$CheckInterface $ScriptName $Interface;
}
} on-error={ }