Configuration: TIM
T_Shell: 248.0 K
-------------------
VCS1cryocooler power: 0.000 W
VCS1gas cooling power: 2.497 W
VCS2 cryocooler power: 0.000 W
VCS2 gas cooling power: 4.250 W
--------
mdot (g/s): 0.013, Holdtime (days): 28.574
boil-off rate (L/day): 8.749
SLPM (from MT/l): 4.252
SLPM (from MTLoad/l): 4.267
MT power: 0.265 W
MTLoad power: 0.265 W
--------
SFT Loading: 892.552 uW
--------
Stage | Temperature
VCS2 | 131.21 K
VCS1 | 50.45 K
--------
Loads
| SFT | MT | VCS1 | VCS2 |
Aperture | 0.00e+00 W | 3.17e-04 W | 1.69e-02 W | 2.03e-01 W |
Radiative | 7.41e-06 W | 1.46e-01 W | 2.20e+00 W | 5.91e+00 W |
Structural | 8.76e-04 W | 6.43e-02 W | 4.31e-01 W | 4.93e-01 W |
Plumbing | 9.32e-06 W | 1.42e-02 W | 5.26e-02 W | 3.41e-01 W |
Wiring | 0.00e+00 W | 1.50e-02 W | 3.45e-02 W | 0.00e+00 W |
--------
Total | 8.93e-04 W | 2.65e-01 W | 2.73e+00 W | 6.94e+00 W |
--------
Loads distribution
| SFT | MT | VCS1 | VCS2 |
Aperture | 00.00 % | 00.12 % | 00.62 % | 02.92 % |
Radiative | 00.83 % | 54.86 % | 80.43 % | 85.06 % |
Structural | 98.13 % | 24.24 % | 15.77 % | 07.11 % |
Plumbing | 01.04 % | 05.34 % | 01.93 % | 04.91 % |
Wiring | 00.00 % | 05.65 % | 01.26 % | 00.00 % |
--------
In-band detector loading: 0.000 W
--------
Number of Iteration: 28
Run time: 1.044 s
--------