From 67f47c4655f9dcbe376bad2948dabf03b8bf6acd Mon Sep 17 00:00:00 2001 From: Jane Date: Tue, 21 Nov 2023 11:17:48 -0800 Subject: [PATCH] Revised type descriptions --- .../resources/HVAC/entity_types/ABSTRACT.yaml | 2 +- .../yaml/resources/HVAC/entity_types/CT.yaml | 2 +- .../yaml/resources/HVAC/entity_types/FCU.yaml | 16 ++-------------- .../HVAC/entity_types/GENERALTYPES.yaml | 5 ++++- ontology/yaml/resources/subfields/subfields.yaml | 2 +- 5 files changed, 9 insertions(+), 18 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 5136286a9..0320faffc 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6963,7 +6963,7 @@ PMDM: HSWTC: guid: "d9cf672c-8081-4e2b-9bba-599d8ac2bbd2" - description: "Heating water valve monitoring on supply water side." + description: "Heating supply water temperature control." is_abstract: true opt_uses: - heating_supply_water_valve_percentage_sensor diff --git a/ontology/yaml/resources/HVAC/entity_types/CT.yaml b/ontology/yaml/resources/HVAC/entity_types/CT.yaml index e8e6cf6cd..13d792065 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CT.yaml @@ -241,4 +241,4 @@ CT_SS_VSC_SWTM_RWISOVM_SWISOVM_FSWISOVM_FRWISOVM: - FRWISOVM opt_uses: - high_water_level_alarm - - low_water_level_alarm + - low_water_level_alarm \ No newline at end of file diff --git a/ontology/yaml/resources/HVAC/entity_types/FCU.yaml b/ontology/yaml/resources/HVAC/entity_types/FCU.yaml index e55456d20..e9496a076 100644 --- a/ontology/yaml/resources/HVAC/entity_types/FCU.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/FCU.yaml @@ -1791,7 +1791,7 @@ FCU_RHDHS_DXDC_DFSS_RTM_DSPM_DFM: - water_leak_alarm - failed_alarm -FCU_DFSS_DFMSC_CSP_CHWZC: +FCU_DFSS_DFMSC_CHWZC: guid: "3d8c3cf8-401f-45d4-89b2-b87f52e4efc9" description: "Chilled water FCU with cooling-only (zone control) and discharge fan multi-speed control." is_canonical: true @@ -1799,16 +1799,4 @@ FCU_DFSS_DFMSC_CSP_CHWZC: - FCU - DFSS - DFMSC - - CSP - - CHWZC - -FCU_DFSS_CSP_DXZC_RAIDC: - guid: "a1652130-9f2c-4d3b-8e89-c9e34d60533e" - description: "Typical DX FCU with cooling-only (discharge control) with return air isolation damper control." - is_canonical: true - implements: - - FCU - - DFSS - - CSP - - DXZC - - RAIDC \ No newline at end of file + - CHWZC \ No newline at end of file diff --git a/ontology/yaml/resources/HVAC/entity_types/GENERALTYPES.yaml b/ontology/yaml/resources/HVAC/entity_types/GENERALTYPES.yaml index afd684e3d..72e816007 100644 --- a/ontology/yaml/resources/HVAC/entity_types/GENERALTYPES.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/GENERALTYPES.yaml @@ -217,10 +217,13 @@ CDWS: ASHP: guid: "548532cf-e175-47e5-b6a1-82ac92362d38" - description: "Tag for air-source heat pumps." + description: "Tag for air-source heat pumps. An ASHP is a device that transfers heat from the surrounding air into + a heating water system through the use of a reversed refrigeration cycle." is_abstract: true opt_uses: - failed_communication_alarm + implements: + - EQUIPMENT CT: guid: "d3872cf4-a6c7-4baf-9115-4cbd92d62e64" diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index 87957b372..7eb7a460d 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -168,7 +168,7 @@ descriptor: model: "Particular design version of an asset (e.g. model_label)." neutral: "Line in the electrical cirucit which carries current back to the source. Distinct from ground." next: "Something that occurs directly in time after the present or most recent one." - no: "Nitrogen monoxide, a colorless gas. It is a toxic air pollutant." + "no": "Nitrogen monoxide, a colorless gas. It is a toxic air pollutant." no2: "Nitrogen dioxide." north: "Cardinal direction; opposite of south" occupancy: "State of being occupied."