From 55bb8210e94dd11ab22f90f1a60bd07291f5c509 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Fri, 21 Jul 2023 11:34:40 +0100 Subject: [PATCH 01/26] new sensor, new fields, soundintensitylevel subfield --- .../yaml/resources/HVAC/entity_types/SENSOR.yaml | 14 ++++++++++++++ .../yaml/resources/fields/telemetry_fields.yaml | 10 +++++++++- ontology/yaml/resources/subfields/subfields.yaml | 2 ++ ontology/yaml/resources/units/units.yaml | 2 ++ 4 files changed, 27 insertions(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index ac2c77d7c0..5deb084d0a 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -255,3 +255,17 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMM: - CO2M - VOCM - PMM + +SENSOR_ZA_CO2M_VOCM_AQIM_ILL: + description: "Simple air quality sensor with VOC, PM 2.5, CO2, temperature and humidity, air quality index, illuminance and sound level monitoring." + is_canonical: true + implements: + - /SENSOR + - ZA + - CO2M + - VOCM + uses: + - soundintensitylevel_sensor + - illuminance_sensor + - zone_air_aqi_sensor + - zone_air_pm2pt5_density_sensor \ No newline at end of file diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index fbb0ee4176..e6d4d84d3b 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3139,4 +3139,12 @@ literals: - low_discharge_air_temperature_alarm: - ACTIVE - - INACTIVE \ No newline at end of file + - INACTIVE + +- fiveminutefixed_total_water_volume_sensor: + fixed_min: 0 + flexible_max: 100 + +- soundintensitylevel_sensor: + fixed_min: -60 + flexible_max: 200 \ No newline at end of file diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index 78579afb83..db19df6aff 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -21,6 +21,7 @@ aggregation: aggregation_descriptor: fivesecondrolling: "Aggregation over advancing time intervals of five seconds." thirtysecondrolling: "Aggregation over advancing thirty second time interval." + fiveminutefixed: "Aggregation over fixed time intervals of five minutes." tenminutefixed: "Aggregation over fixed time intervals of ten minutes." component: battery: "A device used to store power for use at a later time (e.g. in an emergency where grid power is unavailable)." @@ -312,6 +313,7 @@ measurement: rotationalvelocity: "Vector measure of rotation rate, that refers to how fast an object rotates or revolves relative to another point." specificenergy: "Energy per unit mass." specificenthalpy: "Measure of energy of air per unit mass." + soundintensitylevel: "Logarithmic measure of the sound intensity in comparison to a reference value (1e10-12 W/m^2)." temperature: "Measures the temperature of media within a process or system." thermalconductivity: "Measure of a material's ability to conduct heat." thermalcapacity: "Amount of heat to be supplied to an object to produce a unit change in its temperature." diff --git a/ontology/yaml/resources/units/units.yaml b/ontology/yaml/resources/units/units.yaml index 0b06e33c7f..013e842f65 100644 --- a/ontology/yaml/resources/units/units.yaml +++ b/ontology/yaml/resources/units/units.yaml @@ -429,6 +429,8 @@ resistance: offset: 0 rotationalvelocity: revolutions_per_minute: STANDARD +soundintensitylevel: + decibels: STANDARD specificenergy: joules_per_kilogram_kelvin: STANDARD specificenthalpy: From bf1dfe407dbcfd1a5a6690c2dd682d465d4e723e Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Fri, 21 Jul 2023 12:04:29 +0100 Subject: [PATCH 02/26] water meter --- ontology/yaml/resources/METERS/entity_types/WM.yaml | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/ontology/yaml/resources/METERS/entity_types/WM.yaml b/ontology/yaml/resources/METERS/entity_types/WM.yaml index fdc4df113e..6466b41f84 100644 --- a/ontology/yaml/resources/METERS/entity_types/WM.yaml +++ b/ontology/yaml/resources/METERS/entity_types/WM.yaml @@ -36,3 +36,12 @@ WM_WF: - supply_water_volume_accumulator - water_linearvelocity_sensor - water_volume_accumulator + +WM_WVI: + description: "Water meter with total volume & total volume over last 5 minutes." + implements: + - WM + is_canonical: true + uses: + - water_volume_accumulator + - fiveminutefixed_total_water_volume_accumulator From b417cfaf6f220b0416ee20c7e2437768a26cc5ea Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Fri, 21 Jul 2023 12:06:08 +0100 Subject: [PATCH 03/26] typo --- ontology/yaml/resources/METERS/entity_types/WM.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/METERS/entity_types/WM.yaml b/ontology/yaml/resources/METERS/entity_types/WM.yaml index 6466b41f84..27f95d3423 100644 --- a/ontology/yaml/resources/METERS/entity_types/WM.yaml +++ b/ontology/yaml/resources/METERS/entity_types/WM.yaml @@ -44,4 +44,4 @@ WM_WVI: is_canonical: true uses: - water_volume_accumulator - - fiveminutefixed_total_water_volume_accumulator + - fiveminutefixed_total_water_volume_sensor From 385c719aed2669d0398ea0d300e9bcc15d53f00f Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Fri, 21 Jul 2023 12:16:52 +0100 Subject: [PATCH 04/26] move extra fields into optional values of previous type --- .../yaml/resources/HVAC/entity_types/SENSOR.yaml | 14 +++----------- 1 file changed, 3 insertions(+), 11 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index 5deb084d0a..6890afe81b 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -255,17 +255,9 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMM: - CO2M - VOCM - PMM - -SENSOR_ZA_CO2M_VOCM_AQIM_ILL: - description: "Simple air quality sensor with VOC, PM 2.5, CO2, temperature and humidity, air quality index, illuminance and sound level monitoring." - is_canonical: true - implements: - - /SENSOR - - ZA - - CO2M - - VOCM - uses: + opt_uses: - soundintensitylevel_sensor - illuminance_sensor - zone_air_aqi_sensor - - zone_air_pm2pt5_density_sensor \ No newline at end of file + - zone_air_pm10pt0_density_sensor + - zone_air_pm2pt5_density_sensor From ce429583c8ae350b591c3cfb55fd576724c68ae4 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Fri, 21 Jul 2023 12:40:29 +0100 Subject: [PATCH 05/26] occupancy sensor --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 8 ++++++++ ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 8 ++++++++ ontology/yaml/resources/fields/telemetry_fields.yaml | 6 +++++- ontology/yaml/resources/subfields/subfields.yaml | 1 + 4 files changed, 22 insertions(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index f6c9de776b..c9594e84b8 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6691,3 +6691,11 @@ OAQM: - outside_air_co2_concentration_sensor implements: - MONITORING + +ZOC: + description: "Occupancy counter monitoring" + is_abstract: true + uses: + - zone_occupant_counter + implements: + - MONITORING \ No newline at end of file diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index 6890afe81b..a0cdb892f7 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -261,3 +261,11 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMM: - zone_air_aqi_sensor - zone_air_pm10pt0_density_sensor - zone_air_pm2pt5_density_sensor + +SENSOR_ZHM_ZOC: + description: "Zone occupant counter with zone humidity monitoring." + is_canonical: true + implements: + - /SENSOR + - ZHM + - ZOC \ No newline at end of file diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index e6d4d84d3b..b99554b173 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3147,4 +3147,8 @@ literals: - soundintensitylevel_sensor: fixed_min: -60 - flexible_max: 200 \ No newline at end of file + flexible_max: 200 + +- zone_occupant_counter: + fixed_min: 0 + flexible_max: 1000 \ No newline at end of file diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index db19df6aff..b8fea36d14 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -171,6 +171,7 @@ descriptor: no2: "Nitrogen dioxide." north: "Cardinal direction; opposite of south" occupancy: "State of being occupied." + occupant: "A person who occupies a space." occupied: "State of being within scheduled (time of day or week) run-time parameters." oil: "A viscous liquid derived from petroleum, especially for use as a fuel or lubricant." ongoing: "Hapenning currently, right now." From 8f19b3e623c5e956b80c38728c0cd129ecfa817f Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Tue, 25 Jul 2023 14:58:06 +0100 Subject: [PATCH 06/26] update soundintensitylevel to pressure --- ontology/yaml/resources/fields/telemetry_fields.yaml | 2 +- ontology/yaml/resources/subfields/subfields.yaml | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-) diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index 565795cdea..d5db515909 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3163,7 +3163,7 @@ literals: fixed_min: 0 flexible_max: 100 -- soundintensitylevel_sensor: +- soundpressurelevel_sensor: fixed_min: -60 flexible_max: 200 diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index b8fea36d14..4bb1025a90 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -314,7 +314,7 @@ measurement: rotationalvelocity: "Vector measure of rotation rate, that refers to how fast an object rotates or revolves relative to another point." specificenergy: "Energy per unit mass." specificenthalpy: "Measure of energy of air per unit mass." - soundintensitylevel: "Logarithmic measure of the sound intensity in comparison to a reference value (1e10-12 W/m^2)." + soundpressurelevel: "Logarithmic measure of the sound intensity in comparison to a reference value (1e10-12 W/m^2)." temperature: "Measures the temperature of media within a process or system." thermalconductivity: "Measure of a material's ability to conduct heat." thermalcapacity: "Amount of heat to be supplied to an object to produce a unit change in its temperature." From 47b4be939402dbaa4da9bf625deb8a91682b94c0 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Tue, 25 Jul 2023 15:23:58 +0100 Subject: [PATCH 07/26] fixed based off feedback --- .../resources/HVAC/entity_types/ABSTRACT.yaml | 8 ++++ .../resources/HVAC/entity_types/SENSOR.yaml | 37 +++++++++++++++---- .../resources/METERS/entity_types/WM.yaml | 9 ----- .../resources/fields/telemetry_fields.yaml | 5 --- .../yaml/resources/subfields/subfields.yaml | 1 - ontology/yaml/resources/units/units.yaml | 2 +- 6 files changed, 39 insertions(+), 23 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 786778d05e..a5f23d3d60 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6741,4 +6741,12 @@ ZOC: uses: - zone_occupant_counter implements: + - MONITORING + +SPLM: + description: "Sound pressure level monitoring" + is_abstract: true + uses: + - soundpressurelevel_sensor + implements: - MONITORING \ No newline at end of file diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index a0cdb892f7..8065eac969 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -255,12 +255,6 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMM: - CO2M - VOCM - PMM - opt_uses: - - soundintensitylevel_sensor - - illuminance_sensor - - zone_air_aqi_sensor - - zone_air_pm10pt0_density_sensor - - zone_air_pm2pt5_density_sensor SENSOR_ZHM_ZOC: description: "Zone occupant counter with zone humidity monitoring." @@ -268,4 +262,33 @@ SENSOR_ZHM_ZOC: implements: - /SENSOR - ZHM - - ZOC \ No newline at end of file + - ZOC + +SENSOR_ZTM_ZHM_CO2M_VOCM_PML_SPLM: + description: "Indoor Air Quality sensor with temperature, humidity, CO2, VOC, particulates (density), illuminance and sound monitoring." + is_canonical: true + implements: + - /SENSOR + - ZTM + - ZHM + - CO2M + - VOCM + - SPLM + uses: + - zone_air_aqi_sensor + - illuminance_sensor + - zone_air_pm2pt5_density_sensor + - zone_air_pm10pt0_density_sensor + +SENSOR_ZTM_ZHM_CO2M_VOCM_PML: + description: "Indoor Air Quality sensor with temperature, humidity, CO2, VOC, particulates (density) monitoring." + is_canonical: true + implements: + - /SENSOR + - ZTM + - ZHM + - CO2M + - VOCM + uses: + - zone_air_pm2pt5_density_sensor + - zone_air_pm10pt0_density_sensor \ No newline at end of file diff --git a/ontology/yaml/resources/METERS/entity_types/WM.yaml b/ontology/yaml/resources/METERS/entity_types/WM.yaml index 27f95d3423..fdc4df113e 100644 --- a/ontology/yaml/resources/METERS/entity_types/WM.yaml +++ b/ontology/yaml/resources/METERS/entity_types/WM.yaml @@ -36,12 +36,3 @@ WM_WF: - supply_water_volume_accumulator - water_linearvelocity_sensor - water_volume_accumulator - -WM_WVI: - description: "Water meter with total volume & total volume over last 5 minutes." - implements: - - WM - is_canonical: true - uses: - - water_volume_accumulator - - fiveminutefixed_total_water_volume_sensor diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index d5db515909..1b3233bc7c 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3159,10 +3159,6 @@ literals: - ACTIVE - INACTIVE -- fiveminutefixed_total_water_volume_sensor: - fixed_min: 0 - flexible_max: 100 - - soundpressurelevel_sensor: fixed_min: -60 flexible_max: 200 @@ -3170,4 +3166,3 @@ literals: - zone_occupant_counter: fixed_min: 0 flexible_max: 1000 - diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index 4bb1025a90..25bc574a04 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -21,7 +21,6 @@ aggregation: aggregation_descriptor: fivesecondrolling: "Aggregation over advancing time intervals of five seconds." thirtysecondrolling: "Aggregation over advancing thirty second time interval." - fiveminutefixed: "Aggregation over fixed time intervals of five minutes." tenminutefixed: "Aggregation over fixed time intervals of ten minutes." component: battery: "A device used to store power for use at a later time (e.g. in an emergency where grid power is unavailable)." diff --git a/ontology/yaml/resources/units/units.yaml b/ontology/yaml/resources/units/units.yaml index 013e842f65..c7bc982070 100644 --- a/ontology/yaml/resources/units/units.yaml +++ b/ontology/yaml/resources/units/units.yaml @@ -429,7 +429,7 @@ resistance: offset: 0 rotationalvelocity: revolutions_per_minute: STANDARD -soundintensitylevel: +soundpressurelevel: decibels: STANDARD specificenergy: joules_per_kilogram_kelvin: STANDARD From 394567453bbebad76dc2f57717c5eef8f6ffabed Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 14 Aug 2023 10:33:22 +0100 Subject: [PATCH 08/26] added temperature to occupancy count sensor --- ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index 8065eac969..b28ded90e2 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -256,11 +256,12 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMM: - VOCM - PMM -SENSOR_ZHM_ZOC: - description: "Zone occupant counter with zone humidity monitoring." +SENSOR_ZTM_ZHM_ZOC: + description: "Zone occupant counter with zone temperature & humidity monitoring." is_canonical: true implements: - /SENSOR + - ZTM - ZHM - ZOC From 7970c540e28f060e246ec94317ebf4753c5a5931 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 14 Aug 2023 15:03:21 +0100 Subject: [PATCH 09/26] new indoor sensor --- .../resources/HVAC/entity_types/SENSOR.yaml | 24 ++++++++++++++++++- 1 file changed, 23 insertions(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index b28ded90e2..91b64c7b23 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -292,4 +292,26 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PML: - VOCM uses: - zone_air_pm2pt5_density_sensor - - zone_air_pm10pt0_density_sensor \ No newline at end of file + - zone_air_pm10pt0_density_sensor + +SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_XXXXXXXX: + description: "Indoor Air Quality sensor with temperature, humidity, CO2, CO, sound, particulates (density), illuminance, formaldehyde, pressure sensors with air quality, vape, TVOC indexes and motion & tamper detection." + is_canonical: true + implements: + - /SENSOR + - ZTM + - ZHM + - CO2M + - SPLM + - COM + - ZSPM + uses: + - zone_air_aqi_sensor + - illuminance_sensor + - zone_air_pm2pt5_density_sensor + - motion_status + - zone_air_formaldehyde_concentration_sensor + # need to add: + # vape index + # tvoc index + # tamper status \ No newline at end of file From f597b4fda618ec0daee3f874bed6badd180184d8 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 14 Aug 2023 15:04:09 +0100 Subject: [PATCH 10/26] co monitoring --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index a5f23d3d60..358a20d3f2 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -329,6 +329,13 @@ COC: opt_uses: - high_zone_air_co_concentration_alarm +COM: + description: "Carbon monoxide monitoring." + is_abstract: true + implements: + - MONITORING + uses: + - zone_air_co_concentration_sensor BPC: guid: "8199ef48-de0b-4112-bf7a-15876a4acaff" From 82134885f37fff921669ac48425b706dc07c7365 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 14 Aug 2023 15:39:27 +0100 Subject: [PATCH 11/26] completed fields for new sensor --- .../yaml/resources/HVAC/entity_types/SENSOR.yaml | 11 +++++------ ontology/yaml/resources/fields/telemetry_fields.yaml | 12 ++++++++++++ ontology/yaml/resources/subfields/subfields.yaml | 1 + 3 files changed, 18 insertions(+), 6 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index 91b64c7b23..c3957a870d 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -306,12 +306,11 @@ SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_XXXXXXXX: - COM - ZSPM uses: - - zone_air_aqi_sensor - illuminance_sensor - zone_air_pm2pt5_density_sensor - - motion_status - zone_air_formaldehyde_concentration_sensor - # need to add: - # vape index - # tvoc index - # tamper status \ No newline at end of file + - zone_air_aqi_sensor + - zone_air_voc_aqi_sensor + - zone_air_smoke_aqi_sensor + - motion_status + - tamper_status \ No newline at end of file diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index 1b3233bc7c..dc0e7c761c 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3166,3 +3166,15 @@ literals: - zone_occupant_counter: fixed_min: 0 flexible_max: 1000 + +- zone_air_voc_aqi_sensor: + fixed_min: 0 + flexible_max: 500 + +- zone_air_smoke_aqi_sensor: + fixed_min: 0 + flexible_max: 300 + +- tamper_status: + - FALSE + - TRUE \ No newline at end of file diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index 25bc574a04..f5fe21699c 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -238,6 +238,7 @@ descriptor: standby: "A state of waiting to secure an unreserved place for a journey or performance, allocated on the basis of earliest availability." sweeper: "Action performed in a sump to prevent sediment build-up via water turbulence." sync: "The simultaneous operation or activity of two or more things." + tamper: "To interfere with (something, eg. a device) in order to cause damage or make unauthorized alterations." tertiary: "Associated with the tertiary (peripheral) loops of a production process." totaldissolvedsolids: "Total dissolved solids (TDS) is the amount of minerals, metals, organic material and salts that are dissolved in a certain water volume." transducer: "A device that converts energy from one form to another (e.g., sound energy to electrical energy in a microphone, electrical energy to sound energy in a speaker, etc.)." From b0dcc09f351fce38c25e11f52357a6258d14ca49 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 14 Aug 2023 15:42:06 +0100 Subject: [PATCH 12/26] fix field states --- ontology/yaml/resources/fields/telemetry_fields.yaml | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index dc0e7c761c..ade3541e54 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3176,5 +3176,5 @@ literals: flexible_max: 300 - tamper_status: - - FALSE - - TRUE \ No newline at end of file + - ON + - OFF \ No newline at end of file From 8e4c882e3379fae321307b86261f22f40b4835be Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 14 Aug 2023 15:54:37 +0100 Subject: [PATCH 13/26] complete entity type name --- ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index c3957a870d..f58cfd8019 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -294,7 +294,7 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PML: - zone_air_pm2pt5_density_sensor - zone_air_pm10pt0_density_sensor -SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_XXXXXXXX: +SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_IAQMI_TMPR: description: "Indoor Air Quality sensor with temperature, humidity, CO2, CO, sound, particulates (density), illuminance, formaldehyde, pressure sensors with air quality, vape, TVOC indexes and motion & tamper detection." is_canonical: true implements: From 19c08c5f999752a1be4ece1a9f54a44be259bfda Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Tue, 15 Aug 2023 09:46:56 +0100 Subject: [PATCH 14/26] fix smoke range --- ontology/yaml/resources/fields/telemetry_fields.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index ade3541e54..27f659a72a 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3173,7 +3173,7 @@ literals: - zone_air_smoke_aqi_sensor: fixed_min: 0 - flexible_max: 300 + flexible_max: 80 - tamper_status: - ON From fc05e62ce5216f94da5f27f0c56dd647701d9b72 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 21 Aug 2023 08:58:35 +0100 Subject: [PATCH 15/26] Update ABSTRACT.yaml --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 1 + 1 file changed, 1 insertion(+) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index e720843182..25623c6995 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6428,6 +6428,7 @@ VSMC: - low_speed_status - high_speed_status - schedule_run_command + ZOC: description: "Occupancy counter monitoring" is_abstract: true From a8f1ea76f2a6423dcaae22348383291262a73e7d Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 21 Aug 2023 08:59:36 +0100 Subject: [PATCH 16/26] fix auto formatter --- .../resources/HVAC/entity_types/ABSTRACT.yaml | 6484 ++++++++--------- 1 file changed, 3242 insertions(+), 3242 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 25623c6995..67ebfdf001 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -24,63 +24,63 @@ SD: description: "Single duct VAV type, with basic airflow control." is_abstract: true opt_uses: - - cooling_thermal_power_capacity - - run_command - - supply_air_cooling_flowrate_capacity - - supply_air_damper_percentage_sensor - - supply_air_heating_flowrate_capacity - - supply_air_temperature_sensor - - supply_air_ventilation_flowrate_requirement - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - - purge_command - uses: - - supply_air_damper_percentage_command - - supply_air_flowrate_sensor - - supply_air_flowrate_setpoint - implements: - - CONTROL + - cooling_thermal_power_capacity + - run_command + - supply_air_cooling_flowrate_capacity + - supply_air_damper_percentage_sensor + - supply_air_heating_flowrate_capacity + - supply_air_temperature_sensor + - supply_air_ventilation_flowrate_requirement + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + - purge_command + uses: + - supply_air_damper_percentage_command + - supply_air_flowrate_sensor + - supply_air_flowrate_setpoint + implements: + - CONTROL RDM: guid: "9b0b6094-b092-4d27-b894-6dbc299e4833" description: "Very basic system run duration monitoring. " is_abstract: true uses: - - run_time_accumulator + - run_time_accumulator implements: - - MONITORING + - MONITORING DD: guid: "5b09f1bd-f526-4d77-b1a3-1fceda2ba041" description: "Dual duct flow control (hot deck, cold deck)." is_abstract: true opt_uses: - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - heating_thermal_power_capacity - - run_command - - supply_air_cooling_flowrate_capacity - - supply_air_heating_flowrate_capacity - - supply_air_ventilation_flowrate_requirement - - failed_discharge_air_temperature_alarm + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - heating_thermal_power_capacity + - run_command + - supply_air_cooling_flowrate_capacity + - supply_air_heating_flowrate_capacity + - supply_air_ventilation_flowrate_requirement + - failed_discharge_air_temperature_alarm uses: - - cooling_air_damper_percentage_command - - cooling_air_flowrate_sensor - - cooling_air_flowrate_setpoint - - heating_air_damper_percentage_command - - heating_air_flowrate_sensor - - heating_air_flowrate_setpoint + - cooling_air_damper_percentage_command + - cooling_air_flowrate_sensor + - cooling_air_flowrate_setpoint + - heating_air_damper_percentage_command + - heating_air_flowrate_sensor + - heating_air_flowrate_setpoint implements: - - CONTROL + - CONTROL SRC: guid: "0b8da138-b5be-42d1-81ad-13d4196f5352" description: "Very basic run scheduling command. " is_abstract: true uses: - - schedule_run_command + - schedule_run_command implements: - - CONTROL + - CONTROL # Not deprecated but probably not useful OADM: @@ -88,819 +88,819 @@ OADM: description: "Outside air damper monitoring." is_abstract: true uses: - - outside_air_damper_command + - outside_air_damper_command MOAFC: guid: "76994bbd-4395-4a19-914f-d5c9a21fc99b" description: "Minimum (ventilation) outside air flow control." is_abstract: true opt_uses: - - economizer_mode + - economizer_mode uses: - - ventilation_outside_air_damper_percentage_command - - ventilation_outside_air_flowrate_sensor - - ventilation_outside_air_flowrate_setpoint + - ventilation_outside_air_damper_percentage_command + - ventilation_outside_air_flowrate_sensor + - ventilation_outside_air_flowrate_setpoint implements: - - CONTROL + - CONTROL OAFC: guid: "9a39e296-caaa-41d8-a1b2-af9255eb4019" description: "Outside Air Flow Control" is_abstract: true opt_uses: - - economizer_mode - - mixed_air_temperature_sensor - - failed_mixed_air_temperature_alarm + - economizer_mode + - mixed_air_temperature_sensor + - failed_mixed_air_temperature_alarm uses: - - outside_air_damper_percentage_command - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint + - outside_air_damper_percentage_command + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint implements: - - CONTROL + - CONTROL ZTM: guid: "869b8713-9b16-4ca0-b957-630c26e9e506" description: "Zone temperature monitoring." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - zone_air_temperature_sensor + - zone_air_temperature_sensor implements: - - MONITORING + - MONITORING REFM: guid: "df97ad55-5e8f-4cc2-89b7-c07b7a6f28b4" description: "Refrigerant leak monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - zone_air_refrigerant_concentration_sensor + - zone_air_refrigerant_concentration_sensor CSP: guid: "d741e3d6-4997-4a01-8ac1-07b6ff6d53a7" description: "Single cooling setpoint control (IDF room typically)." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - discharge_air_temperature_sensor - - zone_air_relative_humidity_sensor - - zone_occupancy_status - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - zone_air_relative_humidity_sensor + - zone_occupancy_status + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor ZTC: guid: "6140021d-52a9-4d7c-8846-ca296ab32aa2" description: "Single control setpoint with deadband." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - zone_air_deadband_temperature_setpoint - - zone_air_relative_humidity_sensor - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - zone_occupancy_status + - zone_air_deadband_temperature_setpoint + - zone_air_relative_humidity_sensor + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - zone_occupancy_status uses: - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - zone_air_temperature_sensor + - zone_air_temperature_setpoint DSARC: guid: "d891cb1e-f38c-4bec-ae0f-80cc00e2a346" description: "AHU dual supply air reset control." is_abstract: true opt_uses: - - heating_request_count - - supply_air_flowrate_sensor + - heating_request_count + - supply_air_flowrate_sensor uses: - - cooling_request_count - - pressurization_request_count - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_static_pressure_setpoint + - cooling_request_count + - pressurization_request_count + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_static_pressure_setpoint implements: - - CONTROL + - CONTROL DFMSS: guid: "d2e28e09-b84b-479a-85a6-f3494b50c7d3" description: "Discharge fan Start Stop with uneven statuses." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - discharge_air_flowrate_capacity - - discharge_fan_current_sensor - - discharge_fan_power_capacity - - discharge_fan_power_sensor - - discharge_fan_lost_power_alarm + - discharge_air_flowrate_capacity + - discharge_fan_current_sensor + - discharge_fan_power_capacity + - discharge_fan_power_sensor + - discharge_fan_lost_power_alarm uses: - - discharge_fan_run_command - - discharge_fan_run_status_1 - - discharge_fan_run_status_2 + - discharge_fan_run_command + - discharge_fan_run_status_1 + - discharge_fan_run_status_2 DX2RC: guid: "3ffa6782-30f3-4e94-9a5d-a6a2fa47c91a" description: "Compressor run control on retun side (RC)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - return_air_temperature_sensor - - return_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - return_air_temperature_sensor + - return_air_temperature_setpoint implements: - - CONTROL + - CONTROL DFSMC: guid: "c9972693-cc8b-4191-ba3c-d0306e961ca7" description: "Discharge fan multi-speed control." is_abstract: true uses: - - discharge_fan_run_command - - discharge_fan_speed_mode + - discharge_fan_run_command + - discharge_fan_speed_mode DSP: guid: "662d48d1-95a9-4e23-a6e1-daf2fc80d676" description: "Dual setpoint control (heating/cooling thresholds with deadband in between)." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - discharge_air_temperature_sensor - - zone_air_relative_humidity_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - zone_air_relative_humidity_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor DDSP: guid: "079307e1-3bd4-4f90-9c00-66961afbda6a" description: "Dual setpoint control (heating/cooling thresholds with deadband in between) with two zone temp sensors." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - discharge_air_temperature_sensor - - failed_discharge_air_temperature_alarm + - discharge_air_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor_1 - - zone_air_temperature_sensor_2 + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor_1 + - zone_air_temperature_sensor_2 CO2C: guid: "d2659eb3-d7a4-450a-9152-da9b30c9a267" description: "Carbon dioxide control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - zone_air_co2_concentration_sensor - - zone_air_co2_concentration_setpoint + - zone_air_co2_concentration_sensor + - zone_air_co2_concentration_setpoint opt_uses: - - high_zone_air_co2_concentration_alarm + - high_zone_air_co2_concentration_alarm CO2CDSP: guid: "668a3a75-e78d-4755-a360-b370bceda3c5" description: "Carbon dioxide control with dual setpoint." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - high_limit_zone_air_co2_concentration_setpoint - - low_limit_zone_air_co2_concentration_setpoint - - zone_air_co2_concentration_sensor + - high_limit_zone_air_co2_concentration_setpoint + - low_limit_zone_air_co2_concentration_setpoint + - zone_air_co2_concentration_sensor opt_uses: - - high_zone_air_co2_concentration_alarm + - high_zone_air_co2_concentration_alarm COC: guid: "dee7cc87-51cb-460e-8202-eff4001319db" description: "Carbon monoxide control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - zone_air_co_concentration_sensor - - zone_air_co_concentration_setpoint + - zone_air_co_concentration_sensor + - zone_air_co_concentration_setpoint opt_uses: - - high_zone_air_co_concentration_alarm + - high_zone_air_co_concentration_alarm COM: description: "Carbon monoxide monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - zone_air_co_concentration_sensor + - zone_air_co_concentration_sensor BPC: guid: "8199ef48-de0b-4112-bf7a-15876a4acaff" description: "Building pressure control (stand-alone fan)." is_abstract: true uses: - - building_air_static_pressure_sensor - - building_air_static_pressure_setpoint + - building_air_static_pressure_sensor + - building_air_static_pressure_setpoint implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - high_building_air_static_pressure_alarm - - low_building_air_static_pressure_alarm + - high_building_air_static_pressure_alarm + - low_building_air_static_pressure_alarm BPC2X: guid: "4c27f34b-0132-44fb-b99a-355ba6a25d6c" description: "Building pressure control for two pressure sensors (stand-alone fan)." is_abstract: true opt_uses: - - high_building_air_static_pressure_alarm_1 - - high_building_air_static_pressure_alarm_2 - - low_building_air_static_pressure_alarm_1 - - low_building_air_static_pressure_alarm_2 + - high_building_air_static_pressure_alarm_1 + - high_building_air_static_pressure_alarm_2 + - low_building_air_static_pressure_alarm_1 + - low_building_air_static_pressure_alarm_2 uses: - - building_air_static_pressure_sensor_1 - - building_air_static_pressure_sensor_2 - - building_air_static_pressure_setpoint + - building_air_static_pressure_sensor_1 + - building_air_static_pressure_sensor_2 + - building_air_static_pressure_setpoint implements: - - OPERATIONAL + - OPERATIONAL EDPM: guid: "6051d016-4a78-42f4-aeaf-3701417b8773" description: "Exhaust air damper percentage monitoring." is_abstract: true uses: - - exhaust_air_damper_percentage_command - - exhaust_air_damper_percentage_sensor + - exhaust_air_damper_percentage_command + - exhaust_air_damper_percentage_sensor EDM: guid: "e765d413-988e-4524-99b6-9869cff2f02e" description: "Exhaust air damper monitoring." is_abstract: true uses: - - exhaust_air_damper_command - - exhaust_air_damper_status + - exhaust_air_damper_command + - exhaust_air_damper_status EDBPC: guid: "4e428d76-1f7d-46e9-adc6-2affcd170fb6" description: "Building static control with exhaust damper." is_abstract: true opt_uses: - - exhaust_air_damper_percentage_sensor - - exhaust_air_differential_pressure_sensor - - high_building_air_static_pressure_alarm - - low_building_air_static_pressure_alarm + - exhaust_air_damper_percentage_sensor + - exhaust_air_differential_pressure_sensor + - high_building_air_static_pressure_alarm + - low_building_air_static_pressure_alarm uses: - - building_air_static_pressure_sensor - - building_air_static_pressure_setpoint - - exhaust_air_damper_percentage_command + - building_air_static_pressure_sensor + - building_air_static_pressure_setpoint + - exhaust_air_damper_percentage_command implements: - - CONTROL + - CONTROL EDRPC: guid: "79013451-90f3-412c-bde5-425c455b2de5" description: "Return static control with exhaust damper." is_abstract: true opt_uses: - - exhaust_air_damper_percentage_sensor + - exhaust_air_damper_percentage_sensor uses: - - exhaust_air_damper_percentage_command - - return_air_static_pressure_sensor - - return_air_static_pressure_setpoint + - exhaust_air_damper_percentage_command + - return_air_static_pressure_sensor + - return_air_static_pressure_setpoint implements: - - CONTROL + - CONTROL EFFC: guid: "45dd6520-570d-43c6-8085-124f1a99196e" description: "Exhaust fan flow control." is_abstract: true uses: - - exhaust_air_flowrate_sensor - - exhaust_air_flowrate_setpoint - - speed_percentage_command + - exhaust_air_flowrate_sensor + - exhaust_air_flowrate_setpoint + - speed_percentage_command implements: - - CONTROL + - CONTROL BSPC: guid: "78836ff7-b9e6-427d-bbbc-bef212ae6522" description: "Building static pressure control (as part of a composite device)." is_abstract: true opt_uses: - - exhaust_air_damper_percentage_command - - exhaust_fan_run_status - - failed_exhaust_fan_alarm - - high_building_air_static_pressure_alarm - - low_building_air_static_pressure_alarm + - exhaust_air_damper_percentage_command + - exhaust_fan_run_status + - failed_exhaust_fan_alarm + - high_building_air_static_pressure_alarm + - low_building_air_static_pressure_alarm uses: - - building_air_static_pressure_sensor - - building_air_static_pressure_setpoint - - exhaust_fan_run_command + - building_air_static_pressure_sensor + - building_air_static_pressure_setpoint + - exhaust_fan_run_command implements: - - CONTROL + - CONTROL VSC: guid: "5ac998b4-d72e-40f1-9c8f-c905ec8b5cc6" description: "Variable speed control generic." is_abstract: true opt_uses: - - control_mode - - current_sensor - - energy_accumulator - - motor_temperature_sensor - - power_sensor - - run_mode - - run_time_accumulator - - speed_frequency_sensor - - speed_mode - - speed_percentage_sensor - - torque_sensor - - voltage_sensor - - failed_alarm - - local_override_alarm - - lost_power_alarm - - master_alarm - uses: - - run_command - - run_status - - speed_percentage_command - implements: - - OPERATIONAL + - control_mode + - current_sensor + - energy_accumulator + - motor_temperature_sensor + - power_sensor + - run_mode + - run_time_accumulator + - speed_frequency_sensor + - speed_mode + - speed_percentage_sensor + - torque_sensor + - voltage_sensor + - failed_alarm + - local_override_alarm + - lost_power_alarm + - master_alarm + uses: + - run_command + - run_status + - speed_percentage_command + implements: + - OPERATIONAL EFVSC: guid: "dab0bc02-db86-4b2d-be8d-36a4232ef7c0" description: "Variable speed control for exhaust fans." is_abstract: true opt_uses: - - exhaust_fan_current_sensor - - exhaust_fan_power_sensor - - exhaust_fan_run_mode - - exhaust_fan_speed_frequency_sensor - - exhaust_fan_speed_mode - - exhaust_fan_speed_percentage_sensor - - failed_exhaust_fan_alarm + - exhaust_fan_current_sensor + - exhaust_fan_power_sensor + - exhaust_fan_run_mode + - exhaust_fan_speed_frequency_sensor + - exhaust_fan_speed_mode + - exhaust_fan_speed_percentage_sensor + - failed_exhaust_fan_alarm uses: - - exhaust_fan_run_command - - exhaust_fan_run_status - - exhaust_fan_speed_percentage_command + - exhaust_fan_run_command + - exhaust_fan_run_status + - exhaust_fan_speed_percentage_command implements: - - OPERATIONAL + - OPERATIONAL VSFC: guid: "8dcdc4b0-af94-4468-8346-d28442447f84" description: "Variable speed control or monitor in frequency" is_abstract: true uses: - - speed_frequency_command - - speed_frequency_sensor + - speed_frequency_command + - speed_frequency_sensor SFVSC: guid: "ac42c5d1-24d5-4433-b5e5-4ae8843e9ca8" description: "Variable speed control for supply fans." is_abstract: true opt_uses: - - control_mode - - supply_fan_current_sensor - - supply_fan_energy_accumulator - - supply_fan_power_sensor - - supply_fan_power_status - - supply_fan_run_time_accumulator - - supply_fan_speed_frequency_sensor - - supply_fan_speed_mode - - supply_fan_speed_percentage_sensor - - supply_fan_torque_sensor - - supply_fan_voltage_sensor - - failed_supply_fan_alarm - - supply_fan_lost_power_alarm + - control_mode + - supply_fan_current_sensor + - supply_fan_energy_accumulator + - supply_fan_power_sensor + - supply_fan_power_status + - supply_fan_run_time_accumulator + - supply_fan_speed_frequency_sensor + - supply_fan_speed_mode + - supply_fan_speed_percentage_sensor + - supply_fan_torque_sensor + - supply_fan_voltage_sensor + - failed_supply_fan_alarm + - supply_fan_lost_power_alarm uses: - - supply_fan_run_command - - supply_fan_run_status - - supply_fan_speed_percentage_command + - supply_fan_run_command + - supply_fan_run_status + - supply_fan_speed_percentage_command implements: - - OPERATIONAL + - OPERATIONAL DFVSC: guid: "99ebcfbb-f9a5-446f-8faf-ebf61548e2cd" description: "Variable speed control for discharge fans." is_abstract: true opt_uses: - - control_mode - - discharge_fan_current_sensor - - discharge_fan_energy_accumulator - - discharge_fan_power_sensor - - discharge_fan_run_time_accumulator - - discharge_fan_speed_frequency_sensor - - discharge_fan_speed_mode - - discharge_fan_speed_percentage_sensor - - discharge_fan_torque_sensor - - discharge_fan_voltage_sensor - - discharge_fan_lost_power_alarm - - failed_discharge_fan_alarm - - discharge_air_flowrate_sensor + - control_mode + - discharge_fan_current_sensor + - discharge_fan_energy_accumulator + - discharge_fan_power_sensor + - discharge_fan_run_time_accumulator + - discharge_fan_speed_frequency_sensor + - discharge_fan_speed_mode + - discharge_fan_speed_percentage_sensor + - discharge_fan_torque_sensor + - discharge_fan_voltage_sensor + - discharge_fan_lost_power_alarm + - failed_discharge_fan_alarm + - discharge_air_flowrate_sensor uses: - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_percentage_command + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_percentage_command implements: - - OPERATIONAL + - OPERATIONAL DFVSC2X: guid: "8d7ed5d3-725a-46d7-99e5-6cfbed564551" description: "Variable speed control for discharge fans for 2 separate zones." is_abstract: true opt_uses: - - discharge_fan_current_sensor_1 - - discharge_fan_current_sensor_2 - - discharge_fan_power_sensor_1 - - discharge_fan_power_sensor_2 - - discharge_fan_speed_frequency_sensor_1 - - discharge_fan_speed_frequency_sensor_2 - - discharge_fan_speed_percentage_sensor_1 - - discharge_fan_speed_percentage_sensor_2 - - discharge_fan_lost_power_alarm_1 - - discharge_fan_lost_power_alarm_2 + - discharge_fan_current_sensor_1 + - discharge_fan_current_sensor_2 + - discharge_fan_power_sensor_1 + - discharge_fan_power_sensor_2 + - discharge_fan_speed_frequency_sensor_1 + - discharge_fan_speed_frequency_sensor_2 + - discharge_fan_speed_percentage_sensor_1 + - discharge_fan_speed_percentage_sensor_2 + - discharge_fan_lost_power_alarm_1 + - discharge_fan_lost_power_alarm_2 uses: - - discharge_fan_run_command_1 - - discharge_fan_run_command_2 - - discharge_fan_run_status_1 - - discharge_fan_run_status_2 - - discharge_fan_speed_percentage_command_1 - - discharge_fan_speed_percentage_command_2 + - discharge_fan_run_command_1 + - discharge_fan_run_command_2 + - discharge_fan_run_status_1 + - discharge_fan_run_status_2 + - discharge_fan_speed_percentage_command_1 + - discharge_fan_speed_percentage_command_2 implements: - - OPERATIONAL + - OPERATIONAL DFVSFC: guid: "0f7905ae-ef96-4e44-a52b-10d3fd628de9" description: "Variable speed control with frequency setting for discharge fans." is_abstract: true uses: - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_frequency_command + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_frequency_command opt_uses: - - discharge_fan_speed_frequency_sensor - - failed_discharge_fan_alarm + - discharge_fan_speed_frequency_sensor + - failed_discharge_fan_alarm implements: - - OPERATIONAL + - OPERATIONAL DFMSC: guid: "b9228e0a-91ae-4bcf-911d-f5391941814d" description: "Discharge fan multi-speed control." is_abstract: true uses: - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_mode + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_mode opt_uses: - - discharge_fan_run_mode - - schedule_run_command - - failed_discharge_fan_alarm + - discharge_fan_run_mode + - schedule_run_command + - failed_discharge_fan_alarm ZHM: guid: "2832f316-151a-489e-9bd5-0ab159edb0d2" description: "Zone humidity monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - zone_air_relative_humidity_sensor + - zone_air_relative_humidity_sensor DTM: guid: "576e2b80-1711-4bac-abed-c54f2db5351d" description: "Discharge temperature monitoring." is_abstract: true opt_uses: - - discharge_air_relative_humidity_sensor - - discharge_air_specificenthalpy_sensor - - failed_discharge_air_temperature_alarm + - discharge_air_relative_humidity_sensor + - discharge_air_specificenthalpy_sensor + - failed_discharge_air_temperature_alarm uses: - - discharge_air_temperature_sensor + - discharge_air_temperature_sensor implements: - - MONITORING + - MONITORING SS: guid: "5231c7a0-b1bf-48b2-8443-6f37e3b07376" description: "Basic combination of run command and status (start/stop)." is_abstract: true implements: - - /SS - - OPERATIONAL + - /SS + - OPERATIONAL opt_uses: - - control_mode - - current_sensor - - flowrate_capacity - - power_capacity - - power_sensor - - powerfactor_sensor - - run_time_accumulator - - failed_alarm - - local_override_alarm - - lost_power_alarm + - control_mode + - current_sensor + - flowrate_capacity + - power_capacity + - power_sensor + - powerfactor_sensor + - run_time_accumulator + - failed_alarm + - local_override_alarm + - lost_power_alarm SSPC: guid: "7e0a30ec-8a1d-486c-b9f2-96ae60e695cd" description: "Supply static pressure control via supply fan speed" is_abstract: true opt_uses: - - pressurization_request_count - - supply_air_damper_percentage_command - - supply_air_flowrate_sensor - - supply_fan_run_command - - supply_fan_run_status - - supply_fan_speed_frequency_sensor - - supply_fan_speed_percentage_command - - failed_supply_fan_alarm - - high_supply_air_static_pressure_alarm - - low_supply_air_static_pressure_alarm + - pressurization_request_count + - supply_air_damper_percentage_command + - supply_air_flowrate_sensor + - supply_fan_run_command + - supply_fan_run_status + - supply_fan_speed_frequency_sensor + - supply_fan_speed_percentage_command + - failed_supply_fan_alarm + - high_supply_air_static_pressure_alarm + - low_supply_air_static_pressure_alarm uses: - - supply_air_static_pressure_sensor - - supply_air_static_pressure_setpoint + - supply_air_static_pressure_sensor + - supply_air_static_pressure_setpoint implements: - - OPERATIONAL + - OPERATIONAL SPSS: guid: "0b1c2a43-53d8-4349-883c-8bde722fccb5" description: "Spray pump start stop monitoring." is_abstract: true uses: - - spray_pump_run_command - - spray_pump_run_status + - spray_pump_run_command + - spray_pump_run_status implements: - - OPERATIONAL + - OPERATIONAL EFSS: guid: "1df2cdc8-ef3c-472a-ace0-c85d501e121e" description: "Basic combination of exhaust fan run command and status (start/stop)." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - exhaust_air_flowrate_capacity - - exhaust_fan_current_sensor - - exhaust_fan_power_capacity - - exhaust_fan_power_sensor - - exhaust_fan_run_mode - - failed_exhaust_fan_alarm + - exhaust_air_flowrate_capacity + - exhaust_fan_current_sensor + - exhaust_fan_power_capacity + - exhaust_fan_power_sensor + - exhaust_fan_run_mode + - failed_exhaust_fan_alarm uses: - - exhaust_fan_run_command - - exhaust_fan_run_status + - exhaust_fan_run_command + - exhaust_fan_run_status DFSS: guid: "969a750f-d5a3-4d4c-ae74-b810d6ddb774" description: "Basic combination of discharge fan run command and status (start/stop)." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - discharge_air_flowrate_capacity - - discharge_air_static_pressure_sensor - - discharge_fan_current_sensor - - discharge_fan_power_capacity - - discharge_fan_power_sensor - - discharge_fan_run_time_accumulator - - schedule_run_command - - discharge_fan_lost_power_alarm - - failed_discharge_fan_alarm - - overload_discharge_fan_alarm + - discharge_air_flowrate_capacity + - discharge_air_static_pressure_sensor + - discharge_fan_current_sensor + - discharge_fan_power_capacity + - discharge_fan_power_sensor + - discharge_fan_run_time_accumulator + - schedule_run_command + - discharge_fan_lost_power_alarm + - failed_discharge_fan_alarm + - overload_discharge_fan_alarm uses: - - discharge_fan_run_command - - discharge_fan_run_status + - discharge_fan_run_command + - discharge_fan_run_status DFSS2X: guid: "dddfd3fa-86a8-4cf9-b1ca-8026ab54f991" description: "Two discharge fan run command and status (start/stop). With dampers" is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - discharge_fan_run_command_1 - - discharge_fan_run_command_2 - - discharge_fan_run_status_1 - - discharge_fan_run_status_2 + - discharge_fan_run_command_1 + - discharge_fan_run_command_2 + - discharge_fan_run_status_1 + - discharge_fan_run_status_2 HT2RC: guid: "3a770fea-bfb4-4a78-a0a1-c33922871fa2" description: "Two gas or electric heater control on zone side (HSP, DSP)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - discharge_air_temperature_sensor + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - return_air_temperature_sensor - - return_air_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - return_air_temperature_sensor + - return_air_temperature_setpoint implements: - - CONTROL + - CONTROL HTZTC: guid: "bb4d6089-64cd-4994-9906-2a5555f9155a" description: "Gas or electric heater control on zone side (ZC)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heater_run_status - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - heater_run_status + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heater_run_command - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - heater_run_command + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL HT3ZTC: guid: "bd9a4e2d-2467-43ad-8398-62af5e487ceb" description: "Two gas or electric heater control on zone side (HSP, ZTC)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_command_3 - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - heater_run_command_3 + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL HSOUC: guid: "e64d93ac-29cd-46d6-8e4e-6c54db056eb5" description: "Heating occupied/unoccupied setpoint control." is_abstract: true uses: - - zone_air_occupied_heating_temperature_setpoint - - zone_air_temperature_sensor - - zone_air_unoccupied_heating_temperature_setpoint + - zone_air_occupied_heating_temperature_setpoint + - zone_air_temperature_sensor + - zone_air_unoccupied_heating_temperature_setpoint implements: - - CONTROL + - CONTROL opt_uses: - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm HTZOUC: guid: "5407057a-7f34-4bc6-bb9f-3b8fa1149f14" description: "Gas or electric heater control on zone side (ZC)." is_abstract: true opt_uses: - - heater_run_status - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - heater_run_status + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heater_run_command - - zone_air_occupied_heating_temperature_setpoint - - zone_air_temperature_sensor - - zone_air_unoccupied_heating_temperature_setpoint + - heater_run_command + - zone_air_occupied_heating_temperature_setpoint + - zone_air_temperature_sensor + - zone_air_unoccupied_heating_temperature_setpoint implements: - - CONTROL + - CONTROL LCC: guid: "f686598b-eac2-4397-bcc5-a11a6a34c071" description: "Leaving coil temperature control." is_abstract: true uses: - - chilled_water_valve_percentage_command - - leaving_cooling_coil_temperature_sensor - - leaving_cooling_coil_temperature_setpoint + - chilled_water_valve_percentage_command + - leaving_cooling_coil_temperature_sensor + - leaving_cooling_coil_temperature_setpoint implements: - - CONTROL + - CONTROL LCC2X: guid: "ad8c876b-1c34-4148-9f3c-43d91613bcb3" description: "Double valve leaving coil temperature control." is_abstract: true uses: - - chilled_water_valve_percentage_command_1 - - chilled_water_valve_percentage_command_2 - - leaving_cooling_coil_temperature_sensor - - leaving_cooling_coil_temperature_setpoint + - chilled_water_valve_percentage_command_1 + - chilled_water_valve_percentage_command_2 + - leaving_cooling_coil_temperature_sensor + - leaving_cooling_coil_temperature_setpoint implements: - - CONTROL + - CONTROL SFSS: guid: "1e8dd2f7-192a-430b-af2c-db6065664deb" description: "Basic combination of supply fan run command and status (start/stop)." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - supply_air_flowrate_capacity - - supply_fan_current_sensor - - supply_fan_power_capacity - - supply_fan_power_sensor - - supply_fan_run_mode - - supply_fan_run_time_accumulator - - failed_supply_fan_alarm - - supply_fan_lost_power_alarm + - supply_air_flowrate_capacity + - supply_fan_current_sensor + - supply_fan_power_capacity + - supply_fan_power_sensor + - supply_fan_run_mode + - supply_fan_run_time_accumulator + - failed_supply_fan_alarm + - supply_fan_lost_power_alarm uses: - - supply_fan_run_command - - supply_fan_run_status + - supply_fan_run_command + - supply_fan_run_status RHM: guid: "9b13e30c-52b7-45d1-9798-f7c754e959e9" description: "Return air humidity monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - return_air_relative_humidity_sensor + - return_air_relative_humidity_sensor opt_uses: - - high_return_air_relative_humidity_alarm - - low_return_air_relative_humidity_alarm + - high_return_air_relative_humidity_alarm + - low_return_air_relative_humidity_alarm RTM: guid: "7baf6cba-dc20-47f6-845c-bd71b0fa2ae4" description: "Return air temperature monitoring" is_abstract: true implements: - - MONITORING + - MONITORING opt_uses: - - return_air_relative_humidity_sensor - - return_air_specificenthalpy_sensor - - high_return_air_relative_humidity_alarm - - high_return_air_temperature_alarm - - low_return_air_relative_humidity_alarm - - low_return_air_temperature_alarm + - return_air_relative_humidity_sensor + - return_air_specificenthalpy_sensor + - high_return_air_relative_humidity_alarm + - high_return_air_temperature_alarm + - low_return_air_relative_humidity_alarm + - low_return_air_temperature_alarm uses: - - return_air_temperature_sensor + - return_air_temperature_sensor DTC: guid: "fa2354f6-694c-4fd6-b5b5-6352eff50fe4" description: "Discharge air temperatore control" is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint opt_uses: - - failed_discharge_air_temperature_alarm + - failed_discharge_air_temperature_alarm STC: guid: "68140147-a50c-4ee9-b560-fa78596fbd94" description: "Supply air temperature control" is_abstract: true opt_uses: - - cooling_request_count - - heating_request_count - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - cooling_request_count + - heating_request_count + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - OPERATIONAL + - OPERATIONAL RTC: guid: "2145865b-f060-452b-b78b-2fafa6c92b4f" description: "Return air temperature control" is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - return_air_temperature_sensor - - return_air_temperature_setpoint + - return_air_temperature_sensor + - return_air_temperature_setpoint opt_uses: - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm # Rename to OTM OA: @@ -908,98 +908,98 @@ OA: description: "Basic weather station (drybulb temp and humidity)." is_abstract: true opt_uses: - - outside_air_co2_concentration_sensor - - outside_air_dewpoint_temperature_sensor - - outside_air_pressure_sensor - - outside_air_rain_level_sensor - - outside_air_relative_humidity_sensor - - outside_air_specificenthalpy_sensor - - outside_air_voc_concentration_sensor - - outside_air_wetbulb_temperature_sensor - - wind_direction_angle_sensor - - wind_linearvelocity_sensor - - ultraviolet_irradiance_sensor - - outside_air_pm2pt5_density_sensor - - outside_air_aqi_sensor + - outside_air_co2_concentration_sensor + - outside_air_dewpoint_temperature_sensor + - outside_air_pressure_sensor + - outside_air_rain_level_sensor + - outside_air_relative_humidity_sensor + - outside_air_specificenthalpy_sensor + - outside_air_voc_concentration_sensor + - outside_air_wetbulb_temperature_sensor + - wind_direction_angle_sensor + - wind_linearvelocity_sensor + - ultraviolet_irradiance_sensor + - outside_air_pm2pt5_density_sensor + - outside_air_aqi_sensor uses: - - outside_air_temperature_sensor + - outside_air_temperature_sensor implements: - - MONITORING + - MONITORING ZA: guid: "461b178e-e9be-46e6-b8f1-804c138eb17f" description: "Grouped type for zone air psychrometric conditions (RH and temp)" is_abstract: true uses: - - zone_air_relative_humidity_sensor - - zone_air_temperature_sensor + - zone_air_relative_humidity_sensor + - zone_air_temperature_sensor opt_uses: - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm WDT: guid: "0f31290a-83fd-4526-ba80-8cd9c34ce1f9" description: "Temperature differential across water." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - return_water_temperature_sensor - - supply_water_temperature_sensor + - return_water_temperature_sensor + - supply_water_temperature_sensor opt_uses: - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm CHWDT: guid: "0960d44f-87ff-43f5-b576-c19f8a7f2b83" description: "Temperature differential across chilled water." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - chilled_return_water_temperature_sensor - - chilled_supply_water_temperature_sensor + - chilled_return_water_temperature_sensor + - chilled_supply_water_temperature_sensor CHWDPSC: guid: "16555397-2e6c-401c-bb6e-3b93affe444e" description: "Chilled water valve controlling supply air dewpoint temperature." is_abstract: true opt_uses: - - chilled_supply_water_temperature_sensor - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor + - chilled_supply_water_temperature_sensor + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor uses: - - chilled_water_valve_percentage_command - - supply_air_dewpoint_temperature_sensor - - supply_air_dewpoint_temperature_setpoint + - chilled_water_valve_percentage_command + - supply_air_dewpoint_temperature_sensor + - supply_air_dewpoint_temperature_setpoint implements: - - CONTROL + - CONTROL CHWDPSC2X: guid: "25b52b13-03b0-4b5b-b241-e088bfdb06c6" description: "Chilled water valves (2x) controlling supply air dewpoint temperature." is_abstract: true opt_uses: - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor uses: - - chilled_water_valve_percentage_command_1 - - chilled_water_valve_percentage_command_2 - - supply_air_dewpoint_temperature_sensor - - supply_air_dewpoint_temperature_setpoint + - chilled_water_valve_percentage_command_1 + - chilled_water_valve_percentage_command_2 + - supply_air_dewpoint_temperature_sensor + - supply_air_dewpoint_temperature_setpoint implements: - - CONTROL + - CONTROL CWDT: guid: "3cf2eb19-0557-4565-a72b-4059950f9ac7" description: "Temperature differential across condenser water." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - condensing_return_water_temperature_sensor - - condensing_supply_water_temperature_sensor + - condensing_return_water_temperature_sensor + - condensing_supply_water_temperature_sensor # Rename SFN TOTAL_ SWTC: @@ -1007,101 +1007,101 @@ SWTC: description: "Supply water temperature control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - cooling_request_count - - heating_request_count - - return_water_temperature_sensor - - low_return_water_temperature_alarm - - high_return_water_temperature_alarm - - run_command - - cooling_percentage_command - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - cooling_request_count + - heating_request_count + - return_water_temperature_sensor + - low_return_water_temperature_alarm + - high_return_water_temperature_alarm + - run_command + - cooling_percentage_command + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - supply_water_temperature_sensor + - supply_water_temperature_setpoint RWTC: guid: "e6ef58f6-fbda-421d-ac06-d573b093aecd" description: "Return water temperature control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - run_command - - supply_water_temperature_sensor - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - run_command + - supply_water_temperature_sensor + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - return_water_temperature_sensor - - return_water_temperature_setpoint + - return_water_temperature_sensor + - return_water_temperature_setpoint PSWTC: guid: "3846a514-83b2-4ec3-afde-295c476a5624" description: "Process water temperature control." is_abstract: true opt_uses: - - process_return_water_temperature_sensor + - process_return_water_temperature_sensor uses: - - process_supply_water_temperature_sensor - - process_supply_water_temperature_setpoint + - process_supply_water_temperature_sensor + - process_supply_water_temperature_setpoint implements: - - OPERATIONAL + - OPERATIONAL SCHWTC: guid: "d2af9b79-4eb2-4b63-a03a-dc5483372690" description: "Supply chilled water temperature control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - chilled_return_water_temperature_sensor - - cooling_percentage_command - - cooling_request_count + - chilled_return_water_temperature_sensor + - cooling_percentage_command + - cooling_request_count uses: - - chilled_supply_water_temperature_sensor - - chilled_supply_water_temperature_setpoint + - chilled_supply_water_temperature_sensor + - chilled_supply_water_temperature_setpoint WDPC: guid: "86b2c846-0cc3-4828-8648-88c2082c900e" description: "Differential pressure control in whichever system." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - pressurization_request_count - - high_differential_pressure_alarm - - low_differential_pressure_alarm + - pressurization_request_count + - high_differential_pressure_alarm + - low_differential_pressure_alarm uses: - - differential_pressure_sensor - - differential_pressure_setpoint + - differential_pressure_sensor + - differential_pressure_setpoint CGRWTC: guid: "1672a49a-ab80-4989-9ec6-c300d0f44a9e" description: "Cogeneration return water temperature control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - cogeneration_supply_water_temperature_sensor + - cogeneration_supply_water_temperature_sensor uses: - - cogeneration_return_water_temperature_sensor - - cogeneration_return_water_temperature_setpoint + - cogeneration_return_water_temperature_sensor + - cogeneration_return_water_temperature_setpoint WDPC2X: guid: "6e5ff883-c8e2-4e66-8be4-abb9104090c3" description: "Differential pressure control in whichever system, 2 sensors." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - pressurization_request_count - - run_command + - pressurization_request_count + - run_command uses: - - differential_pressure_sensor_1 - - differential_pressure_sensor_2 - - differential_pressure_setpoint + - differential_pressure_sensor_1 + - differential_pressure_sensor_2 + - differential_pressure_setpoint # Change to low_limit_flowrate_setpoint MINFC: @@ -1109,13 +1109,13 @@ MINFC: description: "Minimum flow control for entire loop." is_abstract: true implements: - - CONTROL + - CONTROL uses: - - bypass_valve_percentage_command - - flowrate_sensor - - min_flowrate_setpoint + - bypass_valve_percentage_command + - flowrate_sensor + - min_flowrate_setpoint opt_uses: - - low_flowrate_alarm + - low_flowrate_alarm # Rename to CPSS CPC: @@ -1123,10 +1123,10 @@ CPC: description: "Circulation pump control" is_abstract: true uses: - - circulation_pump_run_command - - circulation_pump_run_status + - circulation_pump_run_command + - circulation_pump_run_status opt_uses: - - failed_circulation_pump_alarm + - failed_circulation_pump_alarm ### NET NEW TYPES ETM: @@ -1134,501 +1134,501 @@ ETM: description: "Basic exhaust temperature monitoring." is_abstract: true uses: - - exhaust_air_temperature_sensor + - exhaust_air_temperature_sensor implements: - - MONITORING + - MONITORING opt_uses: - - failed_exhaust_air_temperature_alarm + - failed_exhaust_air_temperature_alarm ED: guid: "cfc04603-a257-4077-8181-50b564fbdf96" description: "Exhaust air flow control." is_abstract: true opt_uses: - - exhaust_air_damper_percentage_sensor - - exhaust_air_static_pressure_sensor + - exhaust_air_damper_percentage_sensor + - exhaust_air_static_pressure_sensor uses: - - exhaust_air_damper_percentage_command - - exhaust_air_flowrate_sensor - - exhaust_air_flowrate_setpoint + - exhaust_air_damper_percentage_command + - exhaust_air_flowrate_sensor + - exhaust_air_flowrate_setpoint implements: - - CONTROL + - CONTROL RD: guid: "0aecbeb0-8b01-44a2-a0b6-027a034fb2a5" description: "Return damper flow control." is_abstract: true uses: - - return_air_damper_percentage_command - - return_air_flowrate_sensor - - return_air_flowrate_setpoint + - return_air_damper_percentage_command + - return_air_flowrate_sensor + - return_air_flowrate_setpoint implements: - - CONTROL + - CONTROL MTM: guid: "0d7842e9-2af2-4f9f-b2fe-8ba934925103" description: "Mixed air temperature monitoring." is_abstract: true opt_uses: - - mixed_air_dewpoint_temperature_sensor - - mixed_air_relative_humidity_sensor - - failed_mixed_air_temperature_alarm + - mixed_air_dewpoint_temperature_sensor + - mixed_air_relative_humidity_sensor + - failed_mixed_air_temperature_alarm uses: - - mixed_air_temperature_sensor + - mixed_air_temperature_sensor implements: - - MONITORING + - MONITORING MTC: guid: "9f3b733e-0af2-4297-8727-8420b6ae595c" description: "Mixed air temperature control." is_abstract: true uses: - - mixed_air_temperature_sensor - - mixed_air_temperature_setpoint + - mixed_air_temperature_sensor + - mixed_air_temperature_setpoint implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - failed_mixed_air_temperature_alarm + - failed_mixed_air_temperature_alarm STM: guid: "974c8ef0-da06-41a9-ab19-f2f08b14d14f" description: "Basic supply temperature monitoring." is_abstract: true uses: - - supply_air_temperature_sensor + - supply_air_temperature_sensor implements: - - MONITORING + - MONITORING opt_uses: - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm STDSPC: guid: "8d61249d-297a-471d-aa62-dda04e1fe8c7" description: "Supply temperature control dual setpoint." is_abstract: true opt_uses: - - cooling_request_count - - heating_request_count - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - cooling_request_count + - heating_request_count + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_temperature_sensor + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_temperature_sensor implements: - - OPERATIONAL + - OPERATIONAL DSPRTC: guid: "4dcf4685-9635-473c-aa83-53661d2b55be" description: "Dual setpoint return air temp control." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - return_air_relative_humidity_sensor - - failed_discharge_air_temperature_alarm - - high_return_air_relative_humidity_alarm - - high_return_air_temperature_alarm - - low_return_air_relative_humidity_alarm - - low_return_air_temperature_alarm + - discharge_air_temperature_sensor + - return_air_relative_humidity_sensor + - failed_discharge_air_temperature_alarm + - high_return_air_relative_humidity_alarm + - high_return_air_temperature_alarm + - low_return_air_relative_humidity_alarm + - low_return_air_temperature_alarm uses: - - return_air_cooling_temperature_setpoint - - return_air_heating_temperature_setpoint - - return_air_temperature_sensor + - return_air_cooling_temperature_setpoint + - return_air_heating_temperature_setpoint + - return_air_temperature_sensor implements: - - OPERATIONAL + - OPERATIONAL ZHC: guid: "88754caa-5420-4224-92a2-a57bbcd865a6" description: "Zone relative humidity control." is_abstract: true uses: - - zone_air_relative_humidity_sensor - - zone_air_relative_humidity_setpoint + - zone_air_relative_humidity_sensor + - zone_air_relative_humidity_setpoint implements: - - OPERATIONAL + - OPERATIONAL RHC: guid: "8c138f85-254c-4b40-8e5c-d1183e7985c0" description: "Return air relative humidity control." is_abstract: true opt_uses: - - humidifier_run_time_accumulator - - failed_humidifier_alarm - - high_return_air_relative_humidity_alarm - - low_return_air_relative_humidity_alarm + - humidifier_run_time_accumulator + - failed_humidifier_alarm + - high_return_air_relative_humidity_alarm + - low_return_air_relative_humidity_alarm uses: - - return_air_relative_humidity_sensor - - return_air_relative_humidity_setpoint + - return_air_relative_humidity_sensor + - return_air_relative_humidity_setpoint implements: - - OPERATIONAL + - OPERATIONAL RHDHC: guid: "d2149dc2-ce5c-4589-b7b1-4ceac68cff2c" description: "Return humidification/dehumidification control." is_abstract: true opt_uses: - - economizer_mode - - humidification_percentage_command - - failed_humidifier_alarm - - high_return_air_relative_humidity_alarm - - low_return_air_relative_humidity_alarm + - economizer_mode + - humidification_percentage_command + - failed_humidifier_alarm + - high_return_air_relative_humidity_alarm + - low_return_air_relative_humidity_alarm uses: - - dehumidification_run_command - - humidification_run_command - - return_air_relative_humidity_sensor - - return_air_relative_humidity_setpoint + - dehumidification_run_command + - humidification_run_command + - return_air_relative_humidity_sensor + - return_air_relative_humidity_setpoint implements: - - CONTROL + - CONTROL ZHDHC: guid: "0d8a499a-4934-4860-9d35-277381890e2d" description: "Zone humidification/dehumidification control." is_abstract: true opt_uses: - - humidification_percentage_command - - failed_humidifier_alarm + - humidification_percentage_command + - failed_humidifier_alarm uses: - - dehumidification_run_command - - humidification_run_command - - zone_air_relative_humidity_sensor - - zone_air_relative_humidity_setpoint + - dehumidification_run_command + - humidification_run_command + - zone_air_relative_humidity_sensor + - zone_air_relative_humidity_setpoint implements: - - CONTROL + - CONTROL RHHC: guid: "38ca10af-2a94-4765-be1b-34e9c92ac662" description: "Zone humidification control." is_abstract: true opt_uses: - - humidification_percentage_command - - failed_humidifier_alarm - - high_return_air_relative_humidity_alarm - - low_return_air_relative_humidity_alarm + - humidification_percentage_command + - failed_humidifier_alarm + - high_return_air_relative_humidity_alarm + - low_return_air_relative_humidity_alarm uses: - - humidification_run_command - - return_air_relative_humidity_sensor - - return_air_relative_humidity_setpoint + - humidification_run_command + - return_air_relative_humidity_sensor + - return_air_relative_humidity_setpoint SHC: guid: "c27f33dc-19bc-47f4-937a-eab3293b920f" description: "Supply air relative humidity control." is_abstract: true opt_uses: - - humidification_percentage_command - - failed_humidifier_alarm + - humidification_percentage_command + - failed_humidifier_alarm uses: - - dehumidification_run_command - - humidification_run_command - - supply_air_dehumidification_relative_humidity_setpoint - - supply_air_humidification_relative_humidity_setpoint - - supply_air_relative_humidity_sensor + - dehumidification_run_command + - humidification_run_command + - supply_air_dehumidification_relative_humidity_setpoint + - supply_air_humidification_relative_humidity_setpoint + - supply_air_relative_humidity_sensor implements: - - OPERATIONAL + - OPERATIONAL SHM: guid: "9b5089f5-e0a1-420d-bad9-682ac34d2516" description: "Supply air relative humidity monitoring." is_abstract: true uses: - - supply_air_relative_humidity_sensor + - supply_air_relative_humidity_sensor implements: - - MONITORING + - MONITORING REFC: guid: "e043f5e2-fcc4-44b1-818f-0f4e7584adf5" description: "Refrigerant leak control." is_abstract: true uses: - - zone_air_refrigerant_concentration_sensor - - zone_air_refrigerant_concentration_setpoint + - zone_air_refrigerant_concentration_sensor + - zone_air_refrigerant_concentration_setpoint implements: - - OPERATIONAL + - OPERATIONAL CREFM: guid: "49e6ea15-b389-4741-9a7a-e85c851442e1" description: "Cold Room Refrigerator monitoring." is_abstract: true opt_uses: - - compressor_run_status - - run_status - - run_time_accumulator - - compressor_lost_power_alarm - - failed_alarm - - failed_compressor_alarm - - failed_zone_air_temperature_alarm - - frost_alarm - - high_zone_air_temperature_alarm - - local_override_alarm - - low_zone_air_temperature_alarm - - overload_compressor_alarm + - compressor_run_status + - run_status + - run_time_accumulator + - compressor_lost_power_alarm + - failed_alarm + - failed_compressor_alarm + - failed_zone_air_temperature_alarm + - frost_alarm + - high_zone_air_temperature_alarm + - local_override_alarm + - low_zone_air_temperature_alarm + - overload_compressor_alarm uses: - - defrost_temperature_sensor - - zone_air_temperature_sensor + - defrost_temperature_sensor + - zone_air_temperature_sensor EPC: guid: "3d28895c-d30d-4316-bfb6-1dd70b8ad698" description: "Exhaust pressure control." is_abstract: true uses: - - exhaust_air_static_pressure_sensor - - exhaust_air_static_pressure_setpoint + - exhaust_air_static_pressure_sensor + - exhaust_air_static_pressure_setpoint opt_uses: - - exhaust_air_flowrate_sensor + - exhaust_air_flowrate_sensor implements: - - OPERATIONAL + - OPERATIONAL CO2M: guid: "c73f80ff-e57e-4fe4-8bd6-26e4581b7269" description: "Basic carbon dioxide monitoring." is_abstract: true uses: - - zone_air_co2_concentration_sensor + - zone_air_co2_concentration_sensor implements: - - MONITORING + - MONITORING opt_uses: - - high_zone_air_co2_concentration_alarm + - high_zone_air_co2_concentration_alarm VOCM: guid: "d1d343aa-9b3a-41aa-99fe-850c2ba355a8" description: "Volatile organic compound monitoring." is_abstract: true uses: - - zone_air_voc_concentration_sensor + - zone_air_voc_concentration_sensor implements: - - MONITORING + - MONITORING VOCC: guid: "6fec3446-7de8-433e-b644-b760190400df" description: "Volatile organic compound control." is_abstract: true uses: - - zone_air_voc_concentration_sensor - - zone_air_voc_concentration_setpoint + - zone_air_voc_concentration_sensor + - zone_air_voc_concentration_setpoint implements: - - OPERATIONAL + - OPERATIONAL RAVOCC: guid: "abaa943a-7d39-42cf-a950-4451cd928316" description: "Volatile organic compound control for return air from zone." is_abstract: true uses: - - return_air_voc_concentration_sensor - - return_air_voc_concentration_setpoint + - return_air_voc_concentration_sensor + - return_air_voc_concentration_setpoint implements: - - OPERATIONAL + - OPERATIONAL VOCPC: guid: "37c7c6e1-7b21-4f76-b8fc-dad5b1380227" description: "Volatile organic compound percentage control." is_abstract: true uses: - - zone_air_voc_percentage_sensor - - zone_air_voc_percentage_setpoint + - zone_air_voc_percentage_sensor + - zone_air_voc_percentage_setpoint implements: - - OPERATIONAL + - OPERATIONAL BFSS: guid: "500147cd-91f7-4b7d-837c-bf6e915196a3" description: "Booster fan start-stop and feedback." is_abstract: true uses: - - boost_fan_run_command - - boost_fan_run_status + - boost_fan_run_command + - boost_fan_run_status implements: - - OPERATIONAL + - OPERATIONAL DFHLC: guid: "4e6e6b09-8b8d-4ba6-bda5-69c581c5ab5f" description: "Discharge fan three-speed (high/low/off) speed control." is_abstract: true opt_uses: - - discharge_fan_run_command - - discharge_fan_run_status - - failed_discharge_fan_alarm + - discharge_fan_run_command + - discharge_fan_run_status + - failed_discharge_fan_alarm uses: - - high_discharge_fan_speed_command - - low_discharge_fan_speed_command + - high_discharge_fan_speed_command + - low_discharge_fan_speed_command implements: - - OPERATIONAL - - REMAP_REQUIRED + - OPERATIONAL + - REMAP_REQUIRED DFHMLC: guid: "95365c14-2db6-4e80-ae49-38a2b3d2349f" description: "Discharge fan three-speed (high/medium/low/off) speed control." is_abstract: true opt_uses: - - discharge_fan_run_command - - discharge_fan_run_status - - failed_discharge_fan_alarm + - discharge_fan_run_command + - discharge_fan_run_status + - failed_discharge_fan_alarm uses: - - high_discharge_fan_speed_command - - low_discharge_fan_speed_command - - medium_discharge_fan_speed_command + - high_discharge_fan_speed_command + - low_discharge_fan_speed_command + - medium_discharge_fan_speed_command implements: - - OPERATIONAL - - REMAP_REQUIRED + - OPERATIONAL + - REMAP_REQUIRED ESPC: guid: "035692f0-48bd-47df-9c7d-53ce80e5e297" description: "Exhaust air static pressure control." is_abstract: true opt_uses: - - exhaust_fan_speed_percentage_sensor - - failed_exhaust_fan_alarm + - exhaust_fan_speed_percentage_sensor + - failed_exhaust_fan_alarm uses: - - exhaust_air_damper_percentage_command - - exhaust_air_static_pressure_sensor - - exhaust_air_static_pressure_setpoint - - exhaust_fan_run_command - - exhaust_fan_run_status - - exhaust_fan_speed_percentage_command + - exhaust_air_damper_percentage_command + - exhaust_air_static_pressure_sensor + - exhaust_air_static_pressure_setpoint + - exhaust_fan_run_command + - exhaust_fan_run_status + - exhaust_fan_speed_percentage_command implements: - - OPERATIONAL + - OPERATIONAL SSPM: guid: "48f0296b-4fa2-4af8-8edf-3bc7c9ad169b" description: "Supply static pressure monitoring." is_abstract: true uses: - - supply_air_static_pressure_sensor + - supply_air_static_pressure_sensor implements: - - MONITORING + - MONITORING opt_uses: - - high_supply_air_static_pressure_alarm - - low_supply_air_static_pressure_alarm + - high_supply_air_static_pressure_alarm + - low_supply_air_static_pressure_alarm DSPM: guid: "7299212e-c70c-4d49-ac2f-004f1e4672e9" description: "Discharge static pressure monitoring." is_abstract: true uses: - - discharge_air_static_pressure_sensor + - discharge_air_static_pressure_sensor implements: - - MONITORING + - MONITORING opt_uses: - - high_discharge_air_static_pressure_alarm - - low_discharge_air_static_pressure_alarm + - high_discharge_air_static_pressure_alarm + - low_discharge_air_static_pressure_alarm ZSPC: guid: "e7494570-617c-4599-a57e-8e09128e0a07" description: "Zone static pressure control." is_abstract: true opt_uses: - - exhaust_air_damper_percentage_command - - high_zone_air_static_pressure_alarm - - low_zone_air_static_pressure_alarm + - exhaust_air_damper_percentage_command + - high_zone_air_static_pressure_alarm + - low_zone_air_static_pressure_alarm uses: - - zone_air_static_pressure_sensor - - zone_air_static_pressure_setpoint + - zone_air_static_pressure_sensor + - zone_air_static_pressure_setpoint implements: - - OPERATIONAL + - OPERATIONAL ZSPM: guid: "3c3d1d68-4f41-486e-b38c-ff6309f16f2f" description: "Zone static pressure monitoring." is_abstract: true uses: - - zone_air_static_pressure_sensor + - zone_air_static_pressure_sensor implements: - - MONITORING + - MONITORING opt_uses: - - high_zone_air_static_pressure_alarm - - low_zone_air_static_pressure_alarm + - high_zone_air_static_pressure_alarm + - low_zone_air_static_pressure_alarm RSPC: guid: "5b27a493-430f-4a61-8604-0a672ce3fd55" description: "Return air static pressure control." is_abstract: true uses: - - return_air_static_pressure_sensor - - return_air_static_pressure_setpoint + - return_air_static_pressure_sensor + - return_air_static_pressure_setpoint implements: - - OPERATIONAL + - OPERATIONAL PWDPC: guid: "16200082-13a1-4eea-9868-1b2117bb3871" description: "Process water differential pressure control." is_abstract: true uses: - - process_water_differential_pressure_sensor - - process_water_differential_pressure_setpoint + - process_water_differential_pressure_sensor + - process_water_differential_pressure_setpoint implements: - - OPERATIONAL + - OPERATIONAL PWDT: guid: "018769f9-995c-4ad7-95fa-eaf02b4c66ee" description: "Primary-side water delta-T monitoring." is_abstract: true uses: - - primary_return_water_temperature_sensor - - primary_supply_water_temperature_sensor + - primary_return_water_temperature_sensor + - primary_supply_water_temperature_sensor CHPM: guid: "83b25b74-a334-4297-89b3-30ce005e12fe" description: "Chiller pressure monitoring." is_abstract: true uses: - - condenser_pressure_sensor - - differential_pressure_sensor # consider removing or renaming, may not be descriptive enough for WCC - - evaporator_pressure_sensor + - condenser_pressure_sensor + - differential_pressure_sensor # consider removing or renaming, may not be descriptive enough for WCC + - evaporator_pressure_sensor implements: - - MONITORING + - MONITORING opt_uses: - - high_differential_pressure_alarm - - low_differential_pressure_alarm + - high_differential_pressure_alarm + - low_differential_pressure_alarm ESFM: guid: "71fbb830-8e92-4a1f-8dff-c3ef78825aad" description: " An Electrostatic filter used to maintain air quality its run status and alarm monitoring" is_abstract: true uses: - - electrostatic_filter_run_status + - electrostatic_filter_run_status opt_uses: - - electrostatic_filter_alarm + - electrostatic_filter_alarm implements: - - MONITORING + - MONITORING FDPM: guid: "dc6d8a45-8ce6-4ac1-b5b5-cf9fd5727034" description: "Filter pressure monitoring." is_abstract: true uses: - - filter_differential_pressure_sensor + - filter_differential_pressure_sensor implements: - - MONITORING + - MONITORING DFDPM: guid: "a372c26b-010d-4ea3-aa7b-24c98377d9f4" description: "Discharge filter pressure monitoring." is_abstract: true uses: - - discharge_air_filter_differential_pressure_sensor + - discharge_air_filter_differential_pressure_sensor opt_uses: - - discharge_air_filter_alarm + - discharge_air_filter_alarm implements: - - MONITORING + - MONITORING EFDPM: guid: "ea54f179-dfed-4d12-a987-f4919931f979" description: "Exhaust filter pressure monitoring." is_abstract: true uses: - - exhaust_air_filter_differential_pressure_sensor + - exhaust_air_filter_differential_pressure_sensor opt_uses: - - exhaust_air_filter_alarm + - exhaust_air_filter_alarm implements: - - MONITORING + - MONITORING FDPSM: guid: "9cbbf1cf-51ae-44fd-a5ec-ef9ee7a3fcdf" description: "Filter pressure status monitoring." is_abstract: true uses: - - filter_differential_pressure_status + - filter_differential_pressure_status opt_uses: - - filter_alarm + - filter_alarm implements: - - MONITORING + - MONITORING # Chilled water valve control @@ -1637,174 +1637,174 @@ CHWDC: description: "Chilled water valve monitoring on discharge side." is_abstract: true opt_uses: - - chilled_water_flowrate_sensor - - chilled_water_valve_percentage_sensor - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm + - chilled_water_flowrate_sensor + - chilled_water_valve_percentage_sensor + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - chilled_water_valve_percentage_command - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - chilled_water_valve_percentage_command + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint implements: - - CONTROL + - CONTROL CHWSC: guid: "63d00128-355e-4e2f-8cdf-b2d940c4168d" description: "Chilled water valve monitoring on supply side." is_abstract: true opt_uses: - - chilled_supply_water_temperature_sensor - - chilled_water_valve_percentage_sensor - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - supply_air_relative_humidity_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - chilled_supply_water_temperature_sensor + - chilled_water_valve_percentage_sensor + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - supply_air_relative_humidity_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - chilled_water_valve_percentage_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - chilled_water_valve_percentage_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL CHWSDC: guid: "291c8966-a4c3-4329-9d9a-89226e3bb571" description: "Chilled water valve monitoring on supply side." is_abstract: true opt_uses: - - chilled_water_valve_percentage_sensor - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - chilled_water_valve_percentage_sensor + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - chilled_water_valve_percentage_command - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_temperature_sensor + - chilled_water_valve_percentage_command + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_temperature_sensor implements: - - CONTROL + - CONTROL CHW2XSC: guid: "fb42698e-029d-410b-b179-92a25de28ccc" description: "Two chilled water valves." is_abstract: true opt_uses: - - chilled_supply_water_temperature_sensor - - chilled_water_valve_percentage_sensor - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - chilled_supply_water_temperature_sensor + - chilled_water_valve_percentage_sensor + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - chilled_water_valve_percentage_command_1 - - chilled_water_valve_percentage_command_2 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - chilled_water_valve_percentage_command_1 + - chilled_water_valve_percentage_command_2 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL CHWRC: guid: "f9bc8b36-ea88-4318-ab5c-703945fcb465" description: "Chilled water valve monitoring on return side." is_abstract: true opt_uses: - - chilled_water_flowrate_sensor - - chilled_water_valve_percentage_sensor - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - return_air_relative_humidity_sensor - - failed_discharge_air_temperature_alarm - - high_return_air_relative_humidity_alarm - - high_return_air_temperature_alarm - - low_return_air_relative_humidity_alarm - - low_return_air_temperature_alarm + - chilled_water_flowrate_sensor + - chilled_water_valve_percentage_sensor + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - return_air_relative_humidity_sensor + - failed_discharge_air_temperature_alarm + - high_return_air_relative_humidity_alarm + - high_return_air_temperature_alarm + - low_return_air_relative_humidity_alarm + - low_return_air_temperature_alarm uses: - - chilled_water_valve_percentage_command - - return_air_temperature_sensor - - return_air_temperature_setpoint + - chilled_water_valve_percentage_command + - return_air_temperature_sensor + - return_air_temperature_setpoint implements: - - CONTROL + - CONTROL CHWZC: guid: "191ee434-574f-4846-a8eb-7415c277804f" description: "Chilled water valve monitoring on zone side (DSP, CSP)." is_abstract: true opt_uses: - - chilled_supply_water_isolation_valve_command - - chilled_supply_water_isolation_valve_status - - chilled_supply_water_temperature_sensor - - chilled_water_valve_percentage_sensor - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - chilled_supply_water_isolation_valve_command + - chilled_supply_water_isolation_valve_status + - chilled_supply_water_temperature_sensor + - chilled_water_valve_percentage_sensor + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - chilled_water_valve_percentage_command - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor + - chilled_water_valve_percentage_command + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL CHWZTC: guid: "5e9244aa-c51e-42bd-a5ed-f3b12a9cf46e" description: "Chilled water valve monitoring on zone side (ZTC)." is_abstract: true opt_uses: - - chilled_water_flowrate_sensor - - chilled_water_valve_percentage_sensor - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - zone_air_deadband_temperature_setpoint + - chilled_water_flowrate_sensor + - chilled_water_valve_percentage_sensor + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - zone_air_deadband_temperature_setpoint uses: - - chilled_water_valve_percentage_command - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - chilled_water_valve_percentage_command + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL CHWPVM: guid: "751c1130-6108-49c8-9c55-8bfabb762fa8" description: "Chilled water pressure valve command and position monitoring (without regard to what controls it)." is_abstract: true opt_uses: - - chilled_water_flowrate_sensor + - chilled_water_flowrate_sensor uses: - - chilled_water_valve_percentage_sensor + - chilled_water_valve_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL CHWZTC2X: guid: "d4e628ff-e44c-43fd-b48e-bb53d0aaeb00" description: "Chilled water valve control on zone side (ZTC) for two separate zones. Chilled water valve controls to the worst zone." is_abstract: true opt_uses: - - chilled_water_flowrate_sensor - - chilled_water_valve_percentage_sensor - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor_1 - - discharge_air_temperature_sensor_2 - - leaving_cooling_coil_temperature_sensor + - chilled_water_flowrate_sensor + - chilled_water_valve_percentage_sensor + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor_1 + - discharge_air_temperature_sensor_2 + - leaving_cooling_coil_temperature_sensor uses: - - chilled_water_valve_percentage_command - - zone_air_temperature_sensor_1 - - zone_air_temperature_sensor_2 - - zone_air_temperature_setpoint_1 - - zone_air_temperature_setpoint_2 + - chilled_water_valve_percentage_command + - zone_air_temperature_sensor_1 + - zone_air_temperature_sensor_2 + - zone_air_temperature_setpoint_1 + - zone_air_temperature_setpoint_2 implements: - - CONTROL + - CONTROL # DX Control @@ -1813,1712 +1813,1712 @@ DXZTC: description: "Compressor run control on zone side (ZTC)." is_abstract: true opt_uses: - - compressor_run_time_accumulator - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - overload_compressor_alarm + - compressor_run_time_accumulator + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - compressor_run_command + - compressor_run_status + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX2ZTC: guid: "9f49badc-8a3f-4374-abcb-80ac70291893" description: "Compressor run control on zone side (ZTC)." is_abstract: true opt_uses: - - compressor_run_time_accumulator_1 - - compressor_run_time_accumulator_2 - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - compressor_run_time_accumulator_1 + - compressor_run_time_accumulator_2 + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL DXZC: guid: "a4e45116-d36c-45e7-8f45-4d0cf279e6ea" description: "Compressor run control on zone side (DSP, CSP)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor + - compressor_run_command + - compressor_run_status + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL DXDSPRTC: guid: "27091121-2856-4912-91f0-c3fb7b0db097" description: "Compressor run control with dual return temp control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - return_air_cooling_temperature_setpoint - - return_air_heating_temperature_setpoint - - return_air_temperature_sensor + - compressor_run_command + - compressor_run_status + - return_air_cooling_temperature_setpoint + - return_air_heating_temperature_setpoint + - return_air_temperature_sensor implements: - - CONTROL + - CONTROL DX2ZC: guid: "5af2620a-fafd-4c5e-a1ab-338b9a340377" description: "Two compressor run control on zone side (DSP, CSP)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL DX3ZC: guid: "f2c6ea3f-6ac8-41b9-83e7-9050429de6de" description: "Three compressor run control on zone side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL DX4ZC: guid: "0153c2a6-73cc-47f2-aa8d-4b0a5e4c5c57" description: "Four compressor run control on zone side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor - implements: - - CONTROL + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + uses: + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor + implements: + - CONTROL DX2ZC2X: guid: "5170a167-2521-48b8-9728-66f96ecd1af3" description: "Two compressor run control on zone side (DSP, CSP) with two zone temp sensors." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor_1 - - zone_air_temperature_sensor_2 + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor_1 + - zone_air_temperature_sensor_2 implements: - - CONTROL + - CONTROL DXSC: guid: "eb52924b-0813-41ac-aca7-471017f7a5f9" description: "Compressor run control on supply air side (STC)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command #Serves as a duty cycle for single-stage DX sections. - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_percentage_command #Serves as a duty cycle for single-stage DX sections. + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - compressor_run_command + - compressor_run_status + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX2SC: guid: "a58cf1c3-9a2f-4d92-a7ca-54538c642031" description: "Two compressor run control on supply air side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX3SC: guid: "da5a00a2-6ea1-4838-9bf7-21d695cd21b4" description: "Three compressor run control on supply air side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX4SC: guid: "0d19ab0e-9df1-4dbd-85d9-e1ac214f0882" description: "Four compressor run control on supply air side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX2SDC: guid: "4eca020e-b08e-4da5-9dd0-0c9cf8407c4b" description: "Two compressor run control on supply air side (dual temp setpoint)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_temperature_sensor + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_temperature_sensor implements: - - CONTROL + - CONTROL DX4SWC: guid: "beb1f5d7-7ccf-4bb6-8f4e-494d3624589d" description: "Four compressor run control on supply water side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - cooling_percentage_command - - cooling_thermal_power_capacity - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - cooling_percentage_command + - cooling_thermal_power_capacity + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL DX2SWC: guid: "2b9f2e5b-20f2-45bc-b2f8-68818b02b3ac" description: "Two compressor run control on supply water side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - compressor_speed_frequency_sensor - - cooling_percentage_command - - cooling_thermal_power_capacity - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - compressor_speed_frequency_sensor + - cooling_percentage_command + - cooling_thermal_power_capacity + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL DXSWC: guid: "bf02fdd1-5c65-4f62-b552-b629fdace9fb" description: "Compressor run control on supply water side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - cooling_percentage_command - - cooling_thermal_power_capacity - - compressor_lost_power_alarm - - failed_compressor_alarm - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - cooling_percentage_command + - cooling_thermal_power_capacity + - compressor_lost_power_alarm + - failed_compressor_alarm + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - compressor_run_command + - compressor_run_status + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL DX5SC: guid: "225b9056-c352-4aa7-9613-c97675e97fcd" description: "Five compressor run control on supply side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_command_5 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - compressor_run_status_5 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint - implements: - - CONTROL + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + uses: + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_command_5 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - compressor_run_status_5 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint + implements: + - CONTROL DXRC: guid: "58a6126f-413f-4f11-b88d-a44d8395a10d" description: "Compressor run control on return air side (RC)." is_abstract: true opt_uses: - - compressor_run_time_accumulator - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm - - overload_compressor_alarm + - compressor_run_time_accumulator + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - return_air_temperature_sensor - - return_air_temperature_setpoint + - compressor_run_command + - compressor_run_status + - return_air_temperature_sensor + - return_air_temperature_setpoint implements: - - CONTROL + - CONTROL DXDC: guid: "db862405-dadc-4c5b-8fcd-520cb40439ec" description: "Compressor run control on discharge air side (DTC)." is_abstract: true opt_uses: - - compressor_run_time_accumulator - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - overload_compressor_alarm + - compressor_run_time_accumulator + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - compressor_run_command + - compressor_run_status + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX2DC: guid: "1e397d80-ffc8-4b31-97fb-db086b95400d" description: "Two compressor run control on discharge side (DTC)." is_abstract: true opt_uses: - - compressor_run_time_accumulator_1 - - compressor_run_time_accumulator_2 - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm + - compressor_run_time_accumulator_1 + - compressor_run_time_accumulator_2 + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX3DC: guid: "5958d6ee-4e00-4dbe-a9e7-9faf649ebd54" description: "Three compressor run control on discharge side (DTC)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint implements: - - CONTROL + - CONTROL HPSC: guid: "3b23d237-5e53-48f7-a6b7-2279e6c57384" description: "Supply side heat pump control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - heating_request_count - - heating_thermal_power_capacity - - compressor_lost_power_alarm - - failed_compressor_alarm - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - heating_request_count + - heating_thermal_power_capacity + - compressor_lost_power_alarm + - failed_compressor_alarm + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - reversing_valve_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - compressor_run_command + - compressor_run_status + - reversing_valve_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HP2SC: guid: "69544987-6f30-47e2-80be-84cf8a3aecd2" description: "Supply side heat pump control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - heating_request_count - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - heating_request_count + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - reversing_valve_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - reversing_valve_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HPDC: guid: "bf9ceadd-45a6-41f3-859c-f67e82348130" description: "Discharge side heat pump control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_thermal_power_capacity - - heating_thermal_power_capacity - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_thermal_power_capacity + - heating_thermal_power_capacity + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint - - reversing_valve_command + - compressor_run_command + - compressor_run_status + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint + - reversing_valve_command implements: - - CONTROL + - CONTROL HPZTC: guid: "0506375b-4a48-4d5d-92ba-5bd1e9ef087b" description: "Zone temp heat pump control (ZTC)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - heating_thermal_power_capacity - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - heating_thermal_power_capacity + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - reversing_valve_command - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - compressor_run_command + - compressor_run_status + - reversing_valve_command + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL HPZC: guid: "725460fe-6984-4443-9e16-baaa55076649" description: "Zone temp heat pump control (CSP or DSP)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - heating_thermal_power_capacity - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - heating_thermal_power_capacity + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - reversing_valve_command - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - compressor_run_command + - compressor_run_status + - reversing_valve_command + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL HP2ZC: guid: "d0e2eb84-4844-4c2a-a8a8-20c40ee94284" description: "Zone temp heat pump control with two compressors." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - reversing_valve_command - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - reversing_valve_command + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL HWDC: guid: "353bd503-92eb-4f72-8a82-ec1a91413f89" description: "Heating water valve monitoring on discharge air side." is_abstract: true opt_uses: - - discharge_air_relative_humidity_sensor - - heating_thermal_power_capacity - - heating_water_flowrate_sensor - - heating_water_valve_percentage_sensor - - failed_discharge_air_temperature_alarm - - failed_heating_water_valve_alarm + - discharge_air_relative_humidity_sensor + - heating_thermal_power_capacity + - heating_water_flowrate_sensor + - heating_water_valve_percentage_sensor + - failed_discharge_air_temperature_alarm + - failed_heating_water_valve_alarm uses: - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint - - heating_water_valve_percentage_command + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint + - heating_water_valve_percentage_command implements: - - CONTROL + - CONTROL HWRC: guid: "ad089040-996c-4000-aaac-b66c923e8376" description: "Heating water valve monitoring on discharge air side." is_abstract: true opt_uses: - - discharge_air_relative_humidity_sensor - - heating_thermal_power_capacity - - heating_water_flowrate_sensor - - heating_water_valve_percentage_sensor - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - discharge_air_relative_humidity_sensor + - heating_thermal_power_capacity + - heating_water_flowrate_sensor + - heating_water_valve_percentage_sensor + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - heating_water_valve_percentage_command - - return_air_temperature_sensor - - return_air_temperature_setpoint + - heating_water_valve_percentage_command + - return_air_temperature_sensor + - return_air_temperature_setpoint implements: - - CONTROL + - CONTROL HWSC: guid: "c74d0eb6-c5b8-4099-9b18-f5880760df44" description: "Heating water valve monitoring on supply air side." is_abstract: true opt_uses: - - heating_supply_water_temperature_sensor - - heating_request_count - - heating_thermal_power_capacity - - heating_water_valve_percentage_sensor - - leaving_heating_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_supply_water_temperature_sensor + - heating_request_count + - heating_thermal_power_capacity + - heating_water_valve_percentage_sensor + - leaving_heating_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heating_water_valve_percentage_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heating_water_valve_percentage_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HW2SC: guid: "6fed45fd-aa9b-4613-baaa-ed5c44c64f12" description: "Two heating water valves on supply air side." is_abstract: true opt_uses: - - heating_request_count - - heating_thermal_power_capacity - - leaving_heating_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_request_count + - heating_thermal_power_capacity + - leaving_heating_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heating_water_valve_percentage_command_1 - - heating_water_valve_percentage_command_2 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heating_water_valve_percentage_command_1 + - heating_water_valve_percentage_command_2 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HWZC: guid: "c0a7f2ca-171a-4cff-b397-99f8506a8409" description: "Heating water valve monitoring on zone side (DSP/CSP)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heating_supply_water_isolation_valve_command - - heating_supply_water_isolation_valve_status - - heating_thermal_power_capacity - - heating_water_valve_percentage_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - heating_supply_water_isolation_valve_command + - heating_supply_water_isolation_valve_status + - heating_thermal_power_capacity + - heating_water_valve_percentage_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heating_water_valve_percentage_command - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - heating_water_valve_percentage_command + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL HWZTC: guid: "fd0e4588-d368-4399-a356-78c8082b282b" description: "Heating water valve monitoring on zone side (ZTC)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heating_thermal_power_capacity - - heating_water_flowrate_sensor - - heating_water_valve_percentage_sensor - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm - - zone_air_deadband_temperature_setpoint + - discharge_air_temperature_sensor + - heating_thermal_power_capacity + - heating_water_flowrate_sensor + - heating_water_valve_percentage_sensor + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm + - zone_air_deadband_temperature_setpoint uses: - - heating_water_valve_percentage_command - - zone_air_temperature_sensor - - zone_air_temperature_setpoint + - heating_water_valve_percentage_command + - zone_air_temperature_sensor + - zone_air_temperature_setpoint implements: - - CONTROL + - CONTROL HWSWC: guid: "9e892876-39ed-40ac-befb-c68d96bbb81b" description: "Heating water valve monitoring on supply water side." is_abstract: true opt_uses: - - heating_thermal_power_capacity - - heating_water_valve_percentage_sensor - - return_water_temperature_sensor - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - heating_thermal_power_capacity + - heating_water_valve_percentage_sensor + - return_water_temperature_sensor + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - heating_water_valve_percentage_command - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - heating_water_valve_percentage_command + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL PHWSC: guid: "0f2f9a53-6aab-4c9c-801f-bb11b021e42a" description: "Preheating water valve monitoring on supply air side." is_abstract: true opt_uses: - - heating_request_count - - leaving_air_preheating_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_request_count + - leaving_air_preheating_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - preheating_water_valve_percentage_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - preheating_water_valve_percentage_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HWPVM: guid: "0a51d47f-2d53-4a3b-aa9a-f218394b55a7" description: "Heating water pressure valve command and position monitoring (without regard to what controls it)." is_abstract: true opt_uses: - - heating_water_flowrate_sensor + - heating_water_flowrate_sensor uses: - - heating_water_valve_percentage_sensor + - heating_water_valve_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL HTDC: guid: "f88f5021-03fa-4aed-a131-c81cac1e354d" description: "Gas or electric heater control on discharge side." is_abstract: true opt_uses: - - heater_run_status - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm + - heater_run_status + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm uses: - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint - - heater_run_command + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint + - heater_run_command implements: - - CONTROL + - CONTROL HT2DC: guid: "6ca8cf93-24b1-4479-9cbc-d3506a496d3b" description: "Two gas or electric heater control on discharge control." is_abstract: true opt_uses: - - heating_percentage_command - - heating_thermal_power_capacity - - leaving_heating_coil_temperature_sensor - - failed_discharge_air_temperature_alarm + - heating_percentage_command + - heating_thermal_power_capacity + - leaving_heating_coil_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor - - heater_run_command_1 - - heater_run_command_2 + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor + - heater_run_command_1 + - heater_run_command_2 implements: - - CONTROL + - CONTROL HTSC: guid: "bf18254f-acb9-4497-9d54-a7920879f5e5" description: "Gas or electric heater control on supply side." is_abstract: true opt_uses: - - heater_run_status - - heating_percentage_command - - heating_request_count - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heater_run_status + - heating_percentage_command + - heating_request_count + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heater_run_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HTSDC: guid: "d394c55c-af3d-4956-a3b4-9324e4f32ae9" description: "Gas or electric heater control on supply side." is_abstract: true opt_uses: - - heater_run_status - - heating_percentage_command - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heater_run_status + - heating_percentage_command + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_temperature_sensor + - heater_run_command + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_temperature_sensor implements: - - CONTROL + - CONTROL HTRC: guid: "e51bab3a-ba94-4ef9-892e-3d85dfd53ee1" description: "Gas or electric heater control on return side (RC)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heater_run_status - - heater_run_time_accumulator - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - discharge_air_temperature_sensor + - heater_run_status + - heater_run_time_accumulator + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - heater_run_command - - return_air_temperature_sensor - - return_air_temperature_setpoint + - heater_run_command + - return_air_temperature_sensor + - return_air_temperature_setpoint implements: - - CONTROL + - CONTROL HTZC: guid: "35464e33-c1ee-4d66-a2da-aaee5d9713bf" description: "Gas or electric heater control on zone side (ZC)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heater_run_status - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - heater_run_status + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heater_run_command - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - heater_run_command + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL HT2ZC: guid: "bcf4b945-b158-4009-9cb9-7cc01dbbe119" description: "Two gas or electric heater control on zone side (HSP, DSP)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heating_percentage_command - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - heating_percentage_command + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - heater_run_command_1 + - heater_run_command_2 + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL HT2XZTC2X: guid: "7e2c5241-7e53-4857-ac00-2aec02430150" description: "Two separate heating sections going to two different zones on the device, with independent heating control." is_abstract: true opt_uses: - - discharge_air_temperature_sensor_1 - - discharge_air_temperature_sensor_2 - - heating_percentage_command_1 - - heating_percentage_command_2 + - discharge_air_temperature_sensor_1 + - discharge_air_temperature_sensor_2 + - heating_percentage_command_1 + - heating_percentage_command_2 uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_status_1 - - heater_run_status_2 - - zone_air_temperature_sensor_1 - - zone_air_temperature_sensor_2 - - zone_air_temperature_setpoint_1 - - zone_air_temperature_setpoint_2 + - heater_run_command_1 + - heater_run_command_2 + - heater_run_status_1 + - heater_run_status_2 + - zone_air_temperature_sensor_1 + - zone_air_temperature_sensor_2 + - zone_air_temperature_setpoint_1 + - zone_air_temperature_setpoint_2 implements: - - CONTROL + - CONTROL HT3ZC: guid: "ec69793a-e539-4b5c-bf30-b092ce59cce5" description: "Two gas or electric heater control on zone side (HSP, DSP)." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - heating_thermal_power_capacity - - failed_discharge_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - discharge_air_temperature_sensor + - heating_thermal_power_capacity + - failed_discharge_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_command_3 - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - heater_run_command_1 + - heater_run_command_2 + - heater_run_command_3 + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL HTSWC: guid: "d38fd0c3-d7b8-48c7-9ea2-93211ff4c59e" description: "Two gas or electric heater control on supply water side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_thermal_power_capacity - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm - - heater_run_status + - heating_percentage_command + - heating_thermal_power_capacity + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm + - heater_run_status uses: - - heater_run_command - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - heater_run_command + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL HTRWC: guid: "4a0b5a76-9432-4572-832c-2ce41d70a587" description: "Gas or electric heater control on return water side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_thermal_power_capacity - - high_return_water_temperature_alarm - - low_return_water_temperature_alarm - - heater_run_status + - heating_percentage_command + - heating_thermal_power_capacity + - high_return_water_temperature_alarm + - low_return_water_temperature_alarm + - heater_run_status uses: - - heater_run_command - - return_water_temperature_sensor - - return_water_temperature_setpoint + - heater_run_command + - return_water_temperature_sensor + - return_water_temperature_setpoint implements: - - CONTROL + - CONTROL HT2SWC: guid: "cc630fcd-8a18-4fbb-a34b-3eae05b8b49b" description: "Two gas or electric heater control on supply water side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_thermal_power_capacity - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - heating_percentage_command + - heating_thermal_power_capacity + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL HT4SWC: guid: "e8633b6d-6096-4824-a4e0-3cf06f0e2170" description: "Four gas or electric heater control on supply water side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_thermal_power_capacity - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - heating_percentage_command + - heating_thermal_power_capacity + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_command_3 - - heater_run_command_4 - - supply_water_temperature_sensor - - supply_water_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - heater_run_command_3 + - heater_run_command_4 + - supply_water_temperature_sensor + - supply_water_temperature_setpoint implements: - - CONTROL + - CONTROL HT2SC: guid: "5d89ecdf-caaa-4238-8796-1d95a875a81a" description: "Two gas or electric heater control on supply side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_request_count - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_percentage_command + - heating_request_count + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HT3SC: guid: "82b35b25-776f-4829-ada6-42691628d84b" description: "Three gas or electric heater control on supply side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_request_count - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_percentage_command + - heating_request_count + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_command_3 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - heater_run_command_3 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HT4SC: guid: "211e7507-1925-48ca-a46a-852ca4284c3f" description: "Four gas or electric heater control on supply side." is_abstract: true opt_uses: - - heating_percentage_command - - heating_request_count - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_percentage_command + - heating_request_count + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_command_3 - - heater_run_command_4 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heater_run_command_1 + - heater_run_command_2 + - heater_run_command_3 + - heater_run_command_4 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HT2SDC: guid: "ac906e4b-6e44-445c-90f7-2c6968022b31" description: "Two gas or electric heater control on supply side (dual setpoint)." is_abstract: true opt_uses: - - heating_percentage_command - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_percentage_command + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command_1 - - heater_run_command_2 - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_temperature_sensor + - heater_run_command_1 + - heater_run_command_2 + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_temperature_sensor implements: - - CONTROL + - CONTROL HTVSC: guid: "c2e9d73d-949b-4fcf-8f93-47c25ec15a5e" description: "Variable gas to electric control on supply air side." is_abstract: true opt_uses: - - heating_request_count - - heating_thermal_power_capacity - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - heating_request_count + - heating_thermal_power_capacity + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heater_run_command - - heater_run_status - - heating_percentage_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heater_run_command + - heater_run_status + - heating_percentage_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL ECON: guid: "d4285023-3238-443e-bd85-2d91e1706b48" description: "Economizer mode control" is_abstract: true opt_uses: - - low_limit_outside_air_damper_percentage_command - - outside_air_damper_percentage_sensor - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint - - outside_air_relative_humidity_sensor - - outside_air_specificenthalpy_sensor - - return_air_damper_percentage_command - - supply_air_temperature_sensor - - failed_mixed_air_temperature_alarm - - high_return_air_temperature_alarm - - high_supply_air_temperature_alarm - - low_return_air_temperature_alarm - - low_supply_air_temperature_alarm - uses: - - economizer_mode - - mixed_air_temperature_sensor - - outside_air_damper_percentage_command - - outside_air_temperature_sensor - - return_air_temperature_sensor - - supply_air_temperature_setpoint - implements: - - CONTROL + - low_limit_outside_air_damper_percentage_command + - outside_air_damper_percentage_sensor + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint + - outside_air_relative_humidity_sensor + - outside_air_specificenthalpy_sensor + - return_air_damper_percentage_command + - supply_air_temperature_sensor + - failed_mixed_air_temperature_alarm + - high_return_air_temperature_alarm + - high_supply_air_temperature_alarm + - low_return_air_temperature_alarm + - low_supply_air_temperature_alarm + uses: + - economizer_mode + - mixed_air_temperature_sensor + - outside_air_damper_percentage_command + - outside_air_temperature_sensor + - return_air_temperature_sensor + - supply_air_temperature_setpoint + implements: + - CONTROL ECOND: guid: "2640d584-7b8e-4523-b894-beaf4b13e4c0" description: "Economizer mode control - single zone" is_abstract: true opt_uses: - - low_limit_outside_air_damper_percentage_command - - mixed_air_temperature_sensor - - outside_air_damper_percentage_sensor - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint - - return_air_damper_percentage_command - - return_air_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_mixed_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - low_limit_outside_air_damper_percentage_command + - mixed_air_temperature_sensor + - outside_air_damper_percentage_sensor + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint + - return_air_damper_percentage_command + - return_air_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_mixed_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint - - economizer_mode - - outside_air_damper_percentage_command - - outside_air_temperature_sensor + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint + - economizer_mode + - outside_air_damper_percentage_command + - outside_air_temperature_sensor implements: - - CONTROL + - CONTROL ECONM: guid: "729bb0f5-4323-46c6-bfce-176bd4b55869" description: "Economizer mode control" is_abstract: true opt_uses: - - low_limit_outside_air_damper_percentage_command - - outside_air_damper_percentage_sensor - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint - - return_air_damper_percentage_command - - supply_air_temperature_sensor - - failed_mixed_air_temperature_alarm - - high_return_air_temperature_alarm - - high_supply_air_temperature_alarm - - low_return_air_temperature_alarm - - low_supply_air_temperature_alarm + - low_limit_outside_air_damper_percentage_command + - outside_air_damper_percentage_sensor + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint + - return_air_damper_percentage_command + - supply_air_temperature_sensor + - failed_mixed_air_temperature_alarm + - high_return_air_temperature_alarm + - high_supply_air_temperature_alarm + - low_return_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - economizer_mode - - mixed_air_temperature_sensor - - mixed_air_temperature_setpoint - - outside_air_damper_percentage_command - - outside_air_temperature_sensor - - return_air_temperature_sensor + - economizer_mode + - mixed_air_temperature_sensor + - mixed_air_temperature_setpoint + - outside_air_damper_percentage_command + - outside_air_temperature_sensor + - return_air_temperature_sensor implements: - - CONTROL + - CONTROL ECONM2X: guid: "ebde3e58-1637-466e-9737-934e07bcd807" description: "Economizer mode control" is_abstract: true opt_uses: - - low_limit_outside_air_damper_percentage_command - - outside_air_damper_percentage_sensor - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint - - return_air_damper_percentage_command - - supply_air_temperature_sensor - - high_return_air_temperature_alarm - - high_supply_air_temperature_alarm - - low_return_air_temperature_alarm - - low_supply_air_temperature_alarm + - low_limit_outside_air_damper_percentage_command + - outside_air_damper_percentage_sensor + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint + - return_air_damper_percentage_command + - supply_air_temperature_sensor + - high_return_air_temperature_alarm + - high_supply_air_temperature_alarm + - low_return_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - economizer_mode - - mixed_air_temperature_sensor_1 - - mixed_air_temperature_sensor_2 - - mixed_air_temperature_setpoint - - outside_air_damper_percentage_command - - outside_air_temperature_sensor - - return_air_temperature_sensor + - economizer_mode + - mixed_air_temperature_sensor_1 + - mixed_air_temperature_sensor_2 + - mixed_air_temperature_setpoint + - outside_air_damper_percentage_command + - outside_air_temperature_sensor + - return_air_temperature_sensor implements: - - CONTROL + - CONTROL ECONMD: guid: "d19e9024-ddb9-4f1a-8598-f30d52f0beb6" description: "Economizer mode control - single zone" is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - low_limit_outside_air_damper_percentage_command - - outside_air_damper_percentage_sensor - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint - - return_air_damper_percentage_command - - return_air_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_mixed_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - discharge_air_temperature_sensor + - low_limit_outside_air_damper_percentage_command + - outside_air_damper_percentage_sensor + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint + - return_air_damper_percentage_command + - return_air_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_mixed_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - economizer_mode - - mixed_air_temperature_sensor - - mixed_air_temperature_setpoint - - outside_air_damper_percentage_command - - outside_air_temperature_sensor + - economizer_mode + - mixed_air_temperature_sensor + - mixed_air_temperature_setpoint + - outside_air_damper_percentage_command + - outside_air_temperature_sensor implements: - - CONTROL + - CONTROL ECONZ: guid: "a0c19e08-9bb2-4dc3-a65c-4ee050111d65" description: "Economizer mode control - single room" is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - low_limit_outside_air_damper_percentage_command - - mixed_air_temperature_sensor - - outside_air_damper_percentage_sensor - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint - - outside_air_relative_humidity_sensor - - return_air_damper_percentage_command - - return_air_temperature_sensor - - failed_discharge_air_temperature_alarm - - failed_mixed_air_temperature_alarm - - failed_zone_air_temperature_alarm - - high_return_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_return_air_temperature_alarm - - low_zone_air_temperature_alarm - uses: - - economizer_mode - - outside_air_damper_percentage_command - - outside_air_temperature_sensor - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor - implements: - - CONTROL + - discharge_air_temperature_sensor + - low_limit_outside_air_damper_percentage_command + - mixed_air_temperature_sensor + - outside_air_damper_percentage_sensor + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint + - outside_air_relative_humidity_sensor + - return_air_damper_percentage_command + - return_air_temperature_sensor + - failed_discharge_air_temperature_alarm + - failed_mixed_air_temperature_alarm + - failed_zone_air_temperature_alarm + - high_return_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_return_air_temperature_alarm + - low_zone_air_temperature_alarm + uses: + - economizer_mode + - outside_air_damper_percentage_command + - outside_air_temperature_sensor + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor + implements: + - CONTROL VOADM: guid: "cfb7089c-d3b6-4afd-829a-aeeb05b6ff15" description: "Variable outside air damper monitoring." is_abstract: true opt_uses: - - economizer_mode - - low_limit_outside_air_damper_percentage_command - - mixed_air_temperature_sensor - - outside_air_damper_percentage_sensor - - failed_mixed_air_temperature_alarm + - economizer_mode + - low_limit_outside_air_damper_percentage_command + - mixed_air_temperature_sensor + - outside_air_damper_percentage_sensor + - failed_mixed_air_temperature_alarm uses: - - outside_air_damper_percentage_command - - outside_air_temperature_sensor + - outside_air_damper_percentage_command + - outside_air_temperature_sensor implements: - - MONITORING + - MONITORING BYPDM: guid: "b26b31a9-5a4a-4bd8-87d0-97260e739f32" description: "Bypass damper monitoring." is_abstract: true uses: - - bypass_air_damper_percentage_command + - bypass_air_damper_percentage_command implements: - - MONITORING + - MONITORING OAFM: guid: "4d6c951b-f9a2-445d-93d7-a8ab2aa523ad" description: "Outside air flow monitoring" is_abstract: true opt_uses: - - outside_air_damper_percentage_sensor - - outside_air_temperature_sensor + - outside_air_damper_percentage_sensor + - outside_air_temperature_sensor uses: - - outside_air_flowrate_sensor + - outside_air_flowrate_sensor implements: - - MONITORING + - MONITORING OAFMC: guid: "a33ca954-5287-490f-89bc-c3e2b53ceee5" description: "Outside air flow control with minimum setpoint." is_abstract: true opt_uses: - - economizer_mode - - mixed_air_temperature_sensor - - failed_mixed_air_temperature_alarm + - economizer_mode + - mixed_air_temperature_sensor + - failed_mixed_air_temperature_alarm uses: - - outside_air_damper_percentage_command - - outside_air_flowrate_sensor - - ventilation_outside_air_flowrate_setpoint + - outside_air_damper_percentage_command + - outside_air_flowrate_sensor + - ventilation_outside_air_flowrate_setpoint implements: - - CONTROL + - CONTROL OAMC: guid: "48885f9d-2f9e-4c67-be4f-e558f801e02f" description: "Outside air flow control." is_abstract: true opt_uses: - - outside_air_flowrate_sensor + - outside_air_flowrate_sensor uses: - - outside_air_damper_percentage_command - - outside_air_damper_percentage_sensor + - outside_air_damper_percentage_command + - outside_air_damper_percentage_sensor implements: - - CONTROL + - CONTROL OFC: guid: "9e54468c-0ab4-453c-a0e3-a9e70330fef1" description: "Outside air flow control monitoring (without a damper)." is_abstract: true uses: - - outside_air_flowrate_sensor - - outside_air_flowrate_setpoint + - outside_air_flowrate_sensor + - outside_air_flowrate_setpoint implements: - - OPERATIONAL + - OPERATIONAL SFM: guid: "3dcbf69b-ae92-46e8-9b06-4bbb2b16a71f" description: "Supply air flow monitoring." is_abstract: true uses: - - supply_air_flowrate_sensor + - supply_air_flowrate_sensor implements: - - MONITORING + - MONITORING DFM: guid: "fcf4568f-324c-49d3-8a57-c1d4fad24973" description: "Discharge air flow monitoring." is_abstract: true uses: - - discharge_air_flowrate_sensor + - discharge_air_flowrate_sensor implements: - - MONITORING + - MONITORING opt_uses: - - low_discharge_air_flowrate_alarm + - low_discharge_air_flowrate_alarm SFC: guid: "53328995-5e0c-4929-af9f-052104076d11" description: "Supply air flow control." is_abstract: true uses: - - supply_air_flowrate_sensor - - supply_air_flowrate_setpoint + - supply_air_flowrate_sensor + - supply_air_flowrate_setpoint implements: - - OPERATIONAL + - OPERATIONAL RFC: guid: "a8ff3d29-506c-4d34-aead-af60c4b68cb9" description: "Return air flow control." is_abstract: true uses: - - return_air_flowrate_sensor - - return_air_flowrate_setpoint + - return_air_flowrate_sensor + - return_air_flowrate_setpoint implements: - - OPERATIONAL + - OPERATIONAL SARC: guid: "8802aca2-e086-43b1-8be2-1df1104a3f5d" description: "AHU supply air reset control." is_abstract: true opt_uses: - - heating_request_count - - supply_air_flowrate_sensor + - heating_request_count + - supply_air_flowrate_sensor uses: - - cooling_request_count - - pressurization_request_count - - supply_air_static_pressure_setpoint - - supply_air_temperature_setpoint + - cooling_request_count + - pressurization_request_count + - supply_air_static_pressure_setpoint + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL RWISOVPC: guid: "8741bbd4-d41e-4313-9c71-85995078216d" description: "Return water isolation valve percentage monitoring." is_abstract: true opt_uses: - - run_command + - run_command uses: - - return_water_valve_percentage_command - - return_water_valve_percentage_sensor + - return_water_valve_percentage_command + - return_water_valve_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL CHWISOVM: guid: "9d50a373-7c09-49e0-8739-4f1fb18b18b5" description: "Chilled water isolation valve monitoring." is_abstract: true opt_uses: - - run_command + - run_command uses: - - chilled_water_isolation_valve_command - - chilled_water_isolation_valve_status + - chilled_water_isolation_valve_command + - chilled_water_isolation_valve_status implements: - - MONITORING + - MONITORING CDWISOVM: guid: "a90ebfb9-d964-4bc7-aebf-67a72866fd38" description: "Condensing water isolation valve monitoring." is_abstract: true opt_uses: - - run_command + - run_command uses: - - condensing_water_isolation_valve_command - - condensing_water_isolation_valve_status + - condensing_water_isolation_valve_command + - condensing_water_isolation_valve_status implements: - - MONITORING + - MONITORING CDWISOVPM: guid: "8308f584-0b61-4124-abb9-d8f5ca71e880" description: "Condensing water isolation valve percentage monitoring." is_abstract: true opt_uses: - - run_command - - local_override_isolation_valve_alarm + - run_command + - local_override_isolation_valve_alarm uses: - - condensing_water_isolation_valve_percentage_command - - condensing_water_isolation_valve_percentage_sensor + - condensing_water_isolation_valve_percentage_command + - condensing_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING CDWPVM: guid: "588692e6-84a9-4a31-8cc6-09eb599cbe54" description: "Condensing water pressure valve command and position monitoring (without regard to what controls it)." is_abstract: true opt_uses: - - condensing_water_flowrate_sensor + - condensing_water_flowrate_sensor uses: - - condensing_water_valve_percentage_sensor + - condensing_water_valve_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL CDWFRSM: guid: "2a153a56-29ae-403e-9b4d-9b16b3a4794c" description: "Condenser water flowrate status monitoring." is_abstract: true uses: - - condensing_water_flowrate_status + - condensing_water_flowrate_status implements: - - OPERATIONAL + - OPERATIONAL BYPVPM: guid: "57766034-a856-4dfe-b070-fd65673d8dd0" description: "Bypass water valve percentage monitoring." is_abstract: true opt_uses: - - bypass_valve_percentage_sensor + - bypass_valve_percentage_sensor uses: - - bypass_valve_percentage_command + - bypass_valve_percentage_command implements: - - MONITORING + - MONITORING MWVPM: guid: "bd83e820-585d-4e03-9142-7d4355b41574" description: "Make-up water valve percentage monitoring." is_abstract: true uses: - - makeup_water_valve_percentage_command + - makeup_water_valve_percentage_command implements: - - MONITORING + - MONITORING HXSWISOVPM: guid: "04a7805d-e8ff-4b53-9513-d88ede4635ff" description: "Heat exchanger supply isolation water valve percentage monitoring." is_abstract: true uses: - - heat_exchange_supply_water_isolation_valve_percentage_command - - heat_exchange_supply_water_isolation_valve_percentage_sensor + - heat_exchange_supply_water_isolation_valve_percentage_command + - heat_exchange_supply_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING HXRWISOVPM: guid: "789cd63d-8168-43fe-9245-c54a8527482c" description: "Heat exchanger return isolation water valve percentage monitoring." is_abstract: true uses: - - heat_exchange_return_water_isolation_valve_percentage_command - - heat_exchange_return_water_isolation_valve_percentage_sensor + - heat_exchange_return_water_isolation_valve_percentage_command + - heat_exchange_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING HXSWISOVM: guid: "3a617a80-2ab5-4eb5-9cf5-c327359a03c6" description: "Heat exchanger supply isolation water valve monitoring." is_abstract: true uses: - - heat_exchange_supply_water_isolation_valve_command - - heat_exchange_supply_water_isolation_valve_status + - heat_exchange_supply_water_isolation_valve_command + - heat_exchange_supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING HXRWISOVM: guid: "48cee686-e728-4996-be87-0a280ecf9733" description: "Heat exchanger return isolation water valve monitoring." is_abstract: true uses: - - heat_exchange_return_water_isolation_valve_command - - heat_exchange_return_water_isolation_valve_status + - heat_exchange_return_water_isolation_valve_command + - heat_exchange_return_water_isolation_valve_status implements: - - MONITORING + - MONITORING PWISOVM: guid: "f4ea38d8-031e-48cd-be80-43883419ed55" description: "Process water iso valve monitoring." is_abstract: true uses: - - process_water_isolation_valve_command + - process_water_isolation_valve_command implements: - - MONITORING + - MONITORING PWVPM: guid: "2335c3b8-b27f-4ef0-b15b-7df5e8d25e4a" description: "Process water valve percentage monitoring." is_abstract: true uses: - - process_water_valve_percentage_command + - process_water_valve_percentage_command implements: - - MONITORING + - MONITORING CHWBZC: guid: "cbdecbaf-5ddb-4f77-b85f-2fbd92970a70" description: "Chilled water valve binary (open/closed) control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - chilled_water_valve_command - - zone_air_cooling_temperature_setpoint - - zone_air_temperature_sensor + - chilled_water_valve_command + - zone_air_cooling_temperature_setpoint + - zone_air_temperature_sensor opt_uses: - - failed_chilled_water_valve_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - failed_chilled_water_valve_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm CHWBYPVPM: guid: "68cd5104-bf2e-48f3-8b88-c12192509393" description: "Chilled water bypass valve percentage monitoring." is_abstract: true uses: - - chilled_water_bypass_valve_percentage_command - - chilled_water_bypass_valve_percentage_sensor + - chilled_water_bypass_valve_percentage_command + - chilled_water_bypass_valve_percentage_sensor implements: - - MONITORING + - MONITORING MXVPM: guid: "4bb25777-d661-4fd3-9f8f-a84b349ada87" description: "Mixing valve percent monitoring." is_abstract: true uses: - - mixing_valve_percentage_command + - mixing_valve_percentage_command implements: - - MONITORING + - MONITORING WFRM: guid: "f92ea2a3-9bbf-4559-b26d-2864a0a9f973" description: "Water flowrate monitoring." is_abstract: true uses: - - flowrate_sensor + - flowrate_sensor implements: - - MONITORING + - MONITORING opt_uses: - - low_flowrate_alarm + - low_flowrate_alarm WFRC: guid: "55e5d148-7001-40e2-b082-d17cafb3309a" description: "Water flowrate control." is_abstract: true uses: - - flowrate_sensor - - flowrate_setpoint + - flowrate_sensor + - flowrate_setpoint implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - low_flowrate_alarm + - low_flowrate_alarm MWFRC: guid: "b98a5846-1b69-47e4-8913-87beb392ddcb" description: "Minimum water flowrate control." is_abstract: true uses: - - flowrate_sensor - - low_limit_flowrate_setpoint + - flowrate_sensor + - low_limit_flowrate_setpoint implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - low_flowrate_alarm + - low_flowrate_alarm CHWFRM: guid: "3a9f9c94-7d1e-4ed2-839f-66ce995e58fd" description: "Chilled water flowrate monitoring." is_abstract: true uses: - - chilled_water_flowrate_sensor + - chilled_water_flowrate_sensor implements: - - MONITORING + - MONITORING CHWFRSM: guid: "b980da9b-c3de-4aab-b6de-8ab6cbc53178" description: "Chilled water flowrate status monitoring." is_abstract: true uses: - - chilled_water_flowrate_status + - chilled_water_flowrate_status implements: - - MONITORING + - MONITORING SEPM: guid: "a4c57915-39de-47ef-ae66-643b4e12b180" description: "Shade extent monitoring." is_abstract: true uses: - - shade_extent_percentage_command + - shade_extent_percentage_command implements: - - MONITORING + - MONITORING STPM: guid: "8221a52f-102f-486e-8ae2-1c5eee8c31d0" description: "Shade tilt monitoring." is_abstract: true uses: - - shade_tilt_percentage_command + - shade_tilt_percentage_command implements: - - MONITORING + - MONITORING IGM: guid: "ae569be0-3ab9-4f9e-904e-6839aca72b72" description: "Inlet guidevane monitoring." is_abstract: true uses: - - inlet_guidevane_percentage_sensor + - inlet_guidevane_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL CLPM: guid: "603cc89d-c8f4-4ab6-bba2-447a2bd2bbab" description: "Cooling thermal monitoring." is_abstract: true uses: - - cooling_thermal_power_sensor + - cooling_thermal_power_sensor implements: - - MONITORING + - MONITORING PCLPM: guid: "876a8eaa-b0a3-4af7-bdf8-fbef6a93aca5" description: "Process cooling thermal monitoring." is_abstract: true uses: - - process_cooling_thermal_power_sensor + - process_cooling_thermal_power_sensor implements: - - MONITORING + - MONITORING ### POTENTIALLY ONE-OFF TYPES ### DDCO: @@ -3526,1538 +3526,1538 @@ DDCO: description: "Flow control - dual duct, but only cooling." is_abstract: true uses: - - cooling_air_damper_percentage_command_1 - - cooling_air_damper_percentage_command_2 - - cooling_air_flowrate_sensor_1 - - cooling_air_flowrate_sensor_2 - - cooling_air_flowrate_setpoint_1 - - cooling_air_flowrate_setpoint_2 + - cooling_air_damper_percentage_command_1 + - cooling_air_damper_percentage_command_2 + - cooling_air_flowrate_sensor_1 + - cooling_air_flowrate_sensor_2 + - cooling_air_flowrate_setpoint_1 + - cooling_air_flowrate_setpoint_2 implements: - - CONTROL + - CONTROL FDPM2X: guid: "7ac01e64-eadc-4690-8c12-1bd9f48cd9b3" description: "Filter pressure monitoring (2 sensors)." is_abstract: true uses: - - filter_differential_pressure_sensor_1 - - filter_differential_pressure_sensor_2 + - filter_differential_pressure_sensor_1 + - filter_differential_pressure_sensor_2 implements: - - MONITORING + - MONITORING FDPSM2X: guid: "2d883683-d3fc-47c3-8efd-163df172ae9c" description: "Filter pressure status monitoring (2 sensors)." is_abstract: true uses: - - filter_differential_pressure_status_1 - - filter_differential_pressure_status_2 + - filter_differential_pressure_status_1 + - filter_differential_pressure_status_2 opt_uses: - - filter_alarm_1 - - filter_alarm_2 + - filter_alarm_1 + - filter_alarm_2 implements: - - MONITORING + - MONITORING FDPSM4X: guid: "1f150c97-8cd5-436c-ba94-f249c076f498" description: "Filter pressure status monitoring (4 sensors)." is_abstract: true uses: - - filter_differential_pressure_status_1 - - filter_differential_pressure_status_2 - - filter_differential_pressure_status_3 - - filter_differential_pressure_status_4 + - filter_differential_pressure_status_1 + - filter_differential_pressure_status_2 + - filter_differential_pressure_status_3 + - filter_differential_pressure_status_4 opt_uses: - - filter_alarm_1 - - filter_alarm_2 - - filter_alarm_3 - - filter_alarm_4 + - filter_alarm_1 + - filter_alarm_2 + - filter_alarm_3 + - filter_alarm_4 implements: - - MONITORING + - MONITORING FDPM3X: guid: "6b97820b-c413-4c11-ae60-00da68a99b2a" description: "Filter pressure monitoring (3 sensors)." is_abstract: true uses: - - filter_differential_pressure_sensor_1 - - filter_differential_pressure_sensor_2 - - filter_differential_pressure_sensor_3 + - filter_differential_pressure_sensor_1 + - filter_differential_pressure_sensor_2 + - filter_differential_pressure_sensor_3 implements: - - MONITORING + - MONITORING FDPM4X: guid: "8d9c1975-d7e4-4e90-829c-8d8454b4bb9d" description: "Filter pressure monitoring (4 sensors)." is_abstract: true uses: - - filter_differential_pressure_sensor_1 - - filter_differential_pressure_sensor_2 - - filter_differential_pressure_sensor_3 - - filter_differential_pressure_sensor_4 + - filter_differential_pressure_sensor_1 + - filter_differential_pressure_sensor_2 + - filter_differential_pressure_sensor_3 + - filter_differential_pressure_sensor_4 implements: - - MONITORING + - MONITORING CO2C2X: guid: "4f712687-0690-485d-9e73-4880d30eebf4" description: "Carbon dioxide control with dual zone sensors." is_abstract: true uses: - - zone_air_co2_concentration_sensor_1 - - zone_air_co2_concentration_sensor_2 - - zone_air_co2_concentration_setpoint + - zone_air_co2_concentration_sensor_1 + - zone_air_co2_concentration_sensor_2 + - zone_air_co2_concentration_setpoint implements: - - OPERATIONAL + - OPERATIONAL DSP3X: guid: "c3a47cb2-1af2-4bc0-ac17-59fcb019d09f" description: "Dual setpoint zone temp control with 3 temp sensors." is_abstract: true opt_uses: - - discharge_air_temperature_sensor - - failed_discharge_air_temperature_alarm + - discharge_air_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor_1 - - zone_air_temperature_sensor_2 - - zone_air_temperature_sensor_3 + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor_1 + - zone_air_temperature_sensor_2 + - zone_air_temperature_sensor_3 implements: - - OPERATIONAL + - OPERATIONAL EFSS2X: guid: "2088a8dd-7821-4782-be8c-6396601bff6e" description: "Exhaust fan start-stop and feedback with two fans." is_abstract: true opt_uses: - - exhaust_air_flowrate_capacity - - exhaust_fan_current_sensor_1 - - exhaust_fan_current_sensor_2 - - exhaust_fan_power_capacity - - exhaust_fan_power_sensor_1 - - exhaust_fan_power_sensor_2 + - exhaust_air_flowrate_capacity + - exhaust_fan_current_sensor_1 + - exhaust_fan_current_sensor_2 + - exhaust_fan_power_capacity + - exhaust_fan_power_sensor_1 + - exhaust_fan_power_sensor_2 uses: - - exhaust_fan_run_command_1 - - exhaust_fan_run_command_2 - - exhaust_fan_run_status_1 - - exhaust_fan_run_status_2 + - exhaust_fan_run_command_1 + - exhaust_fan_run_command_2 + - exhaust_fan_run_status_1 + - exhaust_fan_run_status_2 implements: - - OPERATIONAL + - OPERATIONAL EFSS3X: guid: "48635fa0-7a1a-4266-96a1-af3a61f172b8" description: "Exhaust fan start-stop and feedback with three fans." is_abstract: true opt_uses: - - exhaust_air_flowrate_capacity - - exhaust_fan_current_sensor_1 - - exhaust_fan_current_sensor_2 - - exhaust_fan_current_sensor_3 - - exhaust_fan_power_capacity - - exhaust_fan_power_sensor_1 - - exhaust_fan_power_sensor_2 - - exhaust_fan_power_sensor_3 + - exhaust_air_flowrate_capacity + - exhaust_fan_current_sensor_1 + - exhaust_fan_current_sensor_2 + - exhaust_fan_current_sensor_3 + - exhaust_fan_power_capacity + - exhaust_fan_power_sensor_1 + - exhaust_fan_power_sensor_2 + - exhaust_fan_power_sensor_3 uses: - - exhaust_fan_run_command_1 - - exhaust_fan_run_command_2 - - exhaust_fan_run_command_3 - - exhaust_fan_run_status_1 - - exhaust_fan_run_status_2 - - exhaust_fan_run_status_3 + - exhaust_fan_run_command_1 + - exhaust_fan_run_command_2 + - exhaust_fan_run_command_3 + - exhaust_fan_run_status_1 + - exhaust_fan_run_status_2 + - exhaust_fan_run_status_3 implements: - - OPERATIONAL + - OPERATIONAL EFSS4X: guid: "fd0fd629-4909-4bbe-aaae-3210ba66c6fb" description: "Exhaust fan start-stop and feedback with four fans." is_abstract: true opt_uses: - - exhaust_air_flowrate_capacity - - exhaust_fan_current_sensor_1 - - exhaust_fan_current_sensor_2 - - exhaust_fan_current_sensor_3 - - exhaust_fan_current_sensor_4 - - exhaust_fan_power_capacity - - exhaust_fan_power_sensor_1 - - exhaust_fan_power_sensor_2 - - exhaust_fan_power_sensor_3 - - exhaust_fan_power_sensor_4 - uses: - - exhaust_fan_run_command_1 - - exhaust_fan_run_command_2 - - exhaust_fan_run_command_3 - - exhaust_fan_run_command_4 - - exhaust_fan_run_status_1 - - exhaust_fan_run_status_2 - - exhaust_fan_run_status_3 - - exhaust_fan_run_status_4 - implements: - - OPERATIONAL + - exhaust_air_flowrate_capacity + - exhaust_fan_current_sensor_1 + - exhaust_fan_current_sensor_2 + - exhaust_fan_current_sensor_3 + - exhaust_fan_current_sensor_4 + - exhaust_fan_power_capacity + - exhaust_fan_power_sensor_1 + - exhaust_fan_power_sensor_2 + - exhaust_fan_power_sensor_3 + - exhaust_fan_power_sensor_4 + uses: + - exhaust_fan_run_command_1 + - exhaust_fan_run_command_2 + - exhaust_fan_run_command_3 + - exhaust_fan_run_command_4 + - exhaust_fan_run_status_1 + - exhaust_fan_run_status_2 + - exhaust_fan_run_status_3 + - exhaust_fan_run_status_4 + implements: + - OPERATIONAL DF2XSS: guid: "d869bbc9-3715-498f-a923-94f436664cd0" description: "Discharge fan start-stop and feedback (2 pts)." is_abstract: true opt_uses: - - discharge_fan_current_sensor - - discharge_fan_power_sensor - - discharge_fan_lost_power_alarm + - discharge_fan_current_sensor + - discharge_fan_power_sensor + - discharge_fan_lost_power_alarm uses: - - discharge_fan_run_command_1 - - discharge_fan_run_command_2 - - discharge_fan_run_status_1 - - discharge_fan_run_status_2 + - discharge_fan_run_command_1 + - discharge_fan_run_command_2 + - discharge_fan_run_status_1 + - discharge_fan_run_status_2 implements: - - OPERATIONAL + - OPERATIONAL SFSS2X: guid: "85ace121-6411-41f7-aea0-03440c7d1352" description: "Supply fan start-stop and feedback for two fans." is_abstract: true opt_uses: - - supply_air_flowrate_capacity - - supply_fan_current_sensor_1 - - supply_fan_current_sensor_2 - - supply_fan_power_capacity - - supply_fan_power_sensor_1 - - supply_fan_power_sensor_2 - - failed_supply_fan_alarm_1 - - failed_supply_fan_alarm_2 + - supply_air_flowrate_capacity + - supply_fan_current_sensor_1 + - supply_fan_current_sensor_2 + - supply_fan_power_capacity + - supply_fan_power_sensor_1 + - supply_fan_power_sensor_2 + - failed_supply_fan_alarm_1 + - failed_supply_fan_alarm_2 uses: - - supply_fan_run_command_1 - - supply_fan_run_command_2 - - supply_fan_run_status_1 - - supply_fan_run_status_2 + - supply_fan_run_command_1 + - supply_fan_run_command_2 + - supply_fan_run_status_1 + - supply_fan_run_status_2 implements: - - OPERATIONAL + - OPERATIONAL SFSS3X: guid: "e1fba819-60f4-459e-ad37-5da8828618dd" description: "Supply fan start-stop and feedback for three fans." is_abstract: true opt_uses: - - supply_air_flowrate_capacity - - supply_fan_current_sensor_1 - - supply_fan_current_sensor_2 - - supply_fan_current_sensor_3 - - supply_fan_power_capacity - - supply_fan_power_sensor_1 - - supply_fan_power_sensor_2 - - supply_fan_power_sensor_3 + - supply_air_flowrate_capacity + - supply_fan_current_sensor_1 + - supply_fan_current_sensor_2 + - supply_fan_current_sensor_3 + - supply_fan_power_capacity + - supply_fan_power_sensor_1 + - supply_fan_power_sensor_2 + - supply_fan_power_sensor_3 uses: - - supply_fan_run_command_1 - - supply_fan_run_command_2 - - supply_fan_run_command_3 - - supply_fan_run_status_1 - - supply_fan_run_status_2 - - supply_fan_run_status_3 + - supply_fan_run_command_1 + - supply_fan_run_command_2 + - supply_fan_run_command_3 + - supply_fan_run_status_1 + - supply_fan_run_status_2 + - supply_fan_run_status_3 implements: - - OPERATIONAL + - OPERATIONAL SFSS4X: guid: "beae050d-0e1e-4a46-a10e-70cf833126a2" description: "Supply fan start-stop and feedback for four fans." is_abstract: true opt_uses: - - supply_air_flowrate_capacity - - supply_fan_current_sensor_1 - - supply_fan_current_sensor_2 - - supply_fan_current_sensor_3 - - supply_fan_current_sensor_4 - - supply_fan_power_capacity - - supply_fan_power_sensor_1 - - supply_fan_power_sensor_2 - - supply_fan_power_sensor_3 - - supply_fan_power_sensor_4 - uses: - - supply_fan_run_command_1 - - supply_fan_run_command_2 - - supply_fan_run_command_3 - - supply_fan_run_command_4 - - supply_fan_run_status_1 - - supply_fan_run_status_2 - - supply_fan_run_status_3 - - supply_fan_run_status_4 - implements: - - OPERATIONAL + - supply_air_flowrate_capacity + - supply_fan_current_sensor_1 + - supply_fan_current_sensor_2 + - supply_fan_current_sensor_3 + - supply_fan_current_sensor_4 + - supply_fan_power_capacity + - supply_fan_power_sensor_1 + - supply_fan_power_sensor_2 + - supply_fan_power_sensor_3 + - supply_fan_power_sensor_4 + uses: + - supply_fan_run_command_1 + - supply_fan_run_command_2 + - supply_fan_run_command_3 + - supply_fan_run_command_4 + - supply_fan_run_status_1 + - supply_fan_run_status_2 + - supply_fan_run_status_3 + - supply_fan_run_status_4 + implements: + - OPERATIONAL EFVSC2X: guid: "71c4f49c-a3be-4f1b-bbf2-dbbda9a13ec2" description: "Exhaust fan variable speed control with feedback and sensoring for two fans." is_abstract: true opt_uses: - - exhaust_fan_current_sensor_1 - - exhaust_fan_current_sensor_2 - - exhaust_fan_power_sensor_1 - - exhaust_fan_power_sensor_2 - - exhaust_fan_speed_frequency_sensor_1 - - exhaust_fan_speed_frequency_sensor_2 - - exhaust_fan_speed_percentage_sensor_1 - - exhaust_fan_speed_percentage_sensor_2 + - exhaust_fan_current_sensor_1 + - exhaust_fan_current_sensor_2 + - exhaust_fan_power_sensor_1 + - exhaust_fan_power_sensor_2 + - exhaust_fan_speed_frequency_sensor_1 + - exhaust_fan_speed_frequency_sensor_2 + - exhaust_fan_speed_percentage_sensor_1 + - exhaust_fan_speed_percentage_sensor_2 uses: - - exhaust_fan_run_command_1 - - exhaust_fan_run_command_2 - - exhaust_fan_run_status_1 - - exhaust_fan_run_status_2 - - exhaust_fan_speed_percentage_command_1 - - exhaust_fan_speed_percentage_command_2 + - exhaust_fan_run_command_1 + - exhaust_fan_run_command_2 + - exhaust_fan_run_status_1 + - exhaust_fan_run_status_2 + - exhaust_fan_speed_percentage_command_1 + - exhaust_fan_speed_percentage_command_2 implements: - - OPERATIONAL + - OPERATIONAL EFVSC3X: guid: "d199dfe8-97a9-4f29-aa27-9f48dafef3fd" description: "Exhaust fan variable speed control with feedback and sensoring for three fans." is_abstract: true opt_uses: - - exhaust_fan_current_sensor_1 - - exhaust_fan_current_sensor_2 - - exhaust_fan_current_sensor_3 - - exhaust_fan_power_sensor_1 - - exhaust_fan_power_sensor_2 - - exhaust_fan_power_sensor_3 - - exhaust_fan_speed_frequency_sensor_1 - - exhaust_fan_speed_frequency_sensor_2 - - exhaust_fan_speed_frequency_sensor_3 - - exhaust_fan_speed_percentage_sensor_1 - - exhaust_fan_speed_percentage_sensor_2 - - exhaust_fan_speed_percentage_sensor_3 - uses: - - exhaust_fan_run_command_1 - - exhaust_fan_run_command_2 - - exhaust_fan_run_command_3 - - exhaust_fan_run_status_1 - - exhaust_fan_run_status_2 - - exhaust_fan_run_status_3 - - exhaust_fan_speed_percentage_command_1 - - exhaust_fan_speed_percentage_command_2 - - exhaust_fan_speed_percentage_command_3 - implements: - - OPERATIONAL + - exhaust_fan_current_sensor_1 + - exhaust_fan_current_sensor_2 + - exhaust_fan_current_sensor_3 + - exhaust_fan_power_sensor_1 + - exhaust_fan_power_sensor_2 + - exhaust_fan_power_sensor_3 + - exhaust_fan_speed_frequency_sensor_1 + - exhaust_fan_speed_frequency_sensor_2 + - exhaust_fan_speed_frequency_sensor_3 + - exhaust_fan_speed_percentage_sensor_1 + - exhaust_fan_speed_percentage_sensor_2 + - exhaust_fan_speed_percentage_sensor_3 + uses: + - exhaust_fan_run_command_1 + - exhaust_fan_run_command_2 + - exhaust_fan_run_command_3 + - exhaust_fan_run_status_1 + - exhaust_fan_run_status_2 + - exhaust_fan_run_status_3 + - exhaust_fan_speed_percentage_command_1 + - exhaust_fan_speed_percentage_command_2 + - exhaust_fan_speed_percentage_command_3 + implements: + - OPERATIONAL EFVSC4X: guid: "5c932992-91c9-4184-9f5f-24d62a99e559" description: "Exhaust fan variable speed control with feedback and sensoring for four fans." is_abstract: true opt_uses: - - exhaust_fan_current_sensor_1 - - exhaust_fan_current_sensor_2 - - exhaust_fan_current_sensor_3 - - exhaust_fan_current_sensor_4 - - exhaust_fan_power_sensor_1 - - exhaust_fan_power_sensor_2 - - exhaust_fan_power_sensor_3 - - exhaust_fan_power_sensor_4 - - exhaust_fan_speed_frequency_sensor_1 - - exhaust_fan_speed_frequency_sensor_2 - - exhaust_fan_speed_frequency_sensor_3 - - exhaust_fan_speed_frequency_sensor_4 - - exhaust_fan_speed_percentage_sensor_1 - - exhaust_fan_speed_percentage_sensor_2 - - exhaust_fan_speed_percentage_sensor_3 - - exhaust_fan_speed_percentage_sensor_4 - uses: - - exhaust_fan_run_command_1 - - exhaust_fan_run_command_2 - - exhaust_fan_run_command_3 - - exhaust_fan_run_command_4 - - exhaust_fan_run_status_1 - - exhaust_fan_run_status_2 - - exhaust_fan_run_status_3 - - exhaust_fan_run_status_4 - - exhaust_fan_speed_percentage_command_1 - - exhaust_fan_speed_percentage_command_2 - - exhaust_fan_speed_percentage_command_3 - - exhaust_fan_speed_percentage_command_4 - implements: - - OPERATIONAL + - exhaust_fan_current_sensor_1 + - exhaust_fan_current_sensor_2 + - exhaust_fan_current_sensor_3 + - exhaust_fan_current_sensor_4 + - exhaust_fan_power_sensor_1 + - exhaust_fan_power_sensor_2 + - exhaust_fan_power_sensor_3 + - exhaust_fan_power_sensor_4 + - exhaust_fan_speed_frequency_sensor_1 + - exhaust_fan_speed_frequency_sensor_2 + - exhaust_fan_speed_frequency_sensor_3 + - exhaust_fan_speed_frequency_sensor_4 + - exhaust_fan_speed_percentage_sensor_1 + - exhaust_fan_speed_percentage_sensor_2 + - exhaust_fan_speed_percentage_sensor_3 + - exhaust_fan_speed_percentage_sensor_4 + uses: + - exhaust_fan_run_command_1 + - exhaust_fan_run_command_2 + - exhaust_fan_run_command_3 + - exhaust_fan_run_command_4 + - exhaust_fan_run_status_1 + - exhaust_fan_run_status_2 + - exhaust_fan_run_status_3 + - exhaust_fan_run_status_4 + - exhaust_fan_speed_percentage_command_1 + - exhaust_fan_speed_percentage_command_2 + - exhaust_fan_speed_percentage_command_3 + - exhaust_fan_speed_percentage_command_4 + implements: + - OPERATIONAL SFVSC2X: guid: "4ec491a2-e832-4994-8496-e1034006495e" description: "Supply fan variable speed control with feedback and sensoring with two fans." is_abstract: true opt_uses: - - supply_fan_current_sensor_1 - - supply_fan_current_sensor_2 - - supply_fan_power_sensor_1 - - supply_fan_power_sensor_2 - - supply_fan_speed_frequency_sensor_1 - - supply_fan_speed_frequency_sensor_2 - - supply_fan_speed_percentage_sensor_1 - - supply_fan_speed_percentage_sensor_2 + - supply_fan_current_sensor_1 + - supply_fan_current_sensor_2 + - supply_fan_power_sensor_1 + - supply_fan_power_sensor_2 + - supply_fan_speed_frequency_sensor_1 + - supply_fan_speed_frequency_sensor_2 + - supply_fan_speed_percentage_sensor_1 + - supply_fan_speed_percentage_sensor_2 uses: - - supply_fan_run_command_1 - - supply_fan_run_command_2 - - supply_fan_run_status_1 - - supply_fan_run_status_2 - - supply_fan_speed_percentage_command_1 - - supply_fan_speed_percentage_command_2 + - supply_fan_run_command_1 + - supply_fan_run_command_2 + - supply_fan_run_status_1 + - supply_fan_run_status_2 + - supply_fan_speed_percentage_command_1 + - supply_fan_speed_percentage_command_2 implements: - - OPERATIONAL + - OPERATIONAL SFVSC3X: guid: "d60c4c55-8265-4ce8-b7a0-b63b93e2c11e" description: "Supply fan variable speed control with feedback and sensoring with three fans." is_abstract: true opt_uses: - - ac_voltage_sensor_1 - - ac_voltage_sensor_2 - - ac_voltage_sensor_3 - - dc_voltage_sensor_1 - - dc_voltage_sensor_2 - - dc_voltage_sensor_3 - - supply_fan_current_sensor_1 - - supply_fan_current_sensor_2 - - supply_fan_current_sensor_3 - - supply_fan_power_sensor_1 - - supply_fan_power_sensor_2 - - supply_fan_power_sensor_3 - - supply_fan_run_mode_1 - - supply_fan_run_mode_2 - - supply_fan_run_mode_3 - - supply_fan_run_time_accumulator_1 - - supply_fan_run_time_accumulator_2 - - supply_fan_run_time_accumulator_3 - - supply_fan_speed_frequency_sensor_1 - - supply_fan_speed_frequency_sensor_2 - - supply_fan_speed_frequency_sensor_3 - - supply_fan_speed_percentage_sensor_1 - - supply_fan_speed_percentage_sensor_2 - - supply_fan_speed_percentage_sensor_3 - uses: - - supply_fan_run_command_1 - - supply_fan_run_command_2 - - supply_fan_run_command_3 - - supply_fan_run_status_1 - - supply_fan_run_status_2 - - supply_fan_run_status_3 - - supply_fan_speed_percentage_command_1 - - supply_fan_speed_percentage_command_2 - - supply_fan_speed_percentage_command_3 - implements: - - OPERATIONAL + - ac_voltage_sensor_1 + - ac_voltage_sensor_2 + - ac_voltage_sensor_3 + - dc_voltage_sensor_1 + - dc_voltage_sensor_2 + - dc_voltage_sensor_3 + - supply_fan_current_sensor_1 + - supply_fan_current_sensor_2 + - supply_fan_current_sensor_3 + - supply_fan_power_sensor_1 + - supply_fan_power_sensor_2 + - supply_fan_power_sensor_3 + - supply_fan_run_mode_1 + - supply_fan_run_mode_2 + - supply_fan_run_mode_3 + - supply_fan_run_time_accumulator_1 + - supply_fan_run_time_accumulator_2 + - supply_fan_run_time_accumulator_3 + - supply_fan_speed_frequency_sensor_1 + - supply_fan_speed_frequency_sensor_2 + - supply_fan_speed_frequency_sensor_3 + - supply_fan_speed_percentage_sensor_1 + - supply_fan_speed_percentage_sensor_2 + - supply_fan_speed_percentage_sensor_3 + uses: + - supply_fan_run_command_1 + - supply_fan_run_command_2 + - supply_fan_run_command_3 + - supply_fan_run_status_1 + - supply_fan_run_status_2 + - supply_fan_run_status_3 + - supply_fan_speed_percentage_command_1 + - supply_fan_speed_percentage_command_2 + - supply_fan_speed_percentage_command_3 + implements: + - OPERATIONAL SFVSC4X: guid: "8649a013-b152-4412-bfa6-f681d8a962df" description: "Supply fan variable speed control with feedback and sensoring with four fans." is_abstract: true opt_uses: - - supply_fan_current_sensor_1 - - supply_fan_current_sensor_2 - - supply_fan_current_sensor_3 - - supply_fan_current_sensor_4 - - supply_fan_power_sensor_1 - - supply_fan_power_sensor_2 - - supply_fan_power_sensor_3 - - supply_fan_power_sensor_4 - - supply_fan_speed_frequency_sensor_1 - - supply_fan_speed_frequency_sensor_2 - - supply_fan_speed_frequency_sensor_3 - - supply_fan_speed_frequency_sensor_4 - - supply_fan_speed_percentage_sensor_1 - - supply_fan_speed_percentage_sensor_2 - - supply_fan_speed_percentage_sensor_3 - - supply_fan_speed_percentage_sensor_4 - uses: - - supply_fan_run_command_1 - - supply_fan_run_command_2 - - supply_fan_run_command_3 - - supply_fan_run_command_4 - - supply_fan_run_status_1 - - supply_fan_run_status_2 - - supply_fan_run_status_3 - - supply_fan_run_status_4 - - supply_fan_speed_percentage_command_1 - - supply_fan_speed_percentage_command_2 - - supply_fan_speed_percentage_command_3 - - supply_fan_speed_percentage_command_4 - implements: - - OPERATIONAL + - supply_fan_current_sensor_1 + - supply_fan_current_sensor_2 + - supply_fan_current_sensor_3 + - supply_fan_current_sensor_4 + - supply_fan_power_sensor_1 + - supply_fan_power_sensor_2 + - supply_fan_power_sensor_3 + - supply_fan_power_sensor_4 + - supply_fan_speed_frequency_sensor_1 + - supply_fan_speed_frequency_sensor_2 + - supply_fan_speed_frequency_sensor_3 + - supply_fan_speed_frequency_sensor_4 + - supply_fan_speed_percentage_sensor_1 + - supply_fan_speed_percentage_sensor_2 + - supply_fan_speed_percentage_sensor_3 + - supply_fan_speed_percentage_sensor_4 + uses: + - supply_fan_run_command_1 + - supply_fan_run_command_2 + - supply_fan_run_command_3 + - supply_fan_run_command_4 + - supply_fan_run_status_1 + - supply_fan_run_status_2 + - supply_fan_run_status_3 + - supply_fan_run_status_4 + - supply_fan_speed_percentage_command_1 + - supply_fan_speed_percentage_command_2 + - supply_fan_speed_percentage_command_3 + - supply_fan_speed_percentage_command_4 + implements: + - OPERATIONAL BYPSSPC: guid: "1811cdec-15d7-4d1d-b819-f7673aa694c2" description: "Supply static pressure control with bypass damper." is_abstract: true opt_uses: - - supply_air_flowrate_sensor - - failed_supply_fan_alarm - - high_supply_air_static_pressure_alarm - - low_supply_air_static_pressure_alarm + - supply_air_flowrate_sensor + - failed_supply_fan_alarm + - high_supply_air_static_pressure_alarm + - low_supply_air_static_pressure_alarm uses: - - bypass_air_damper_percentage_command - - supply_air_static_pressure_sensor - - supply_air_static_pressure_setpoint - - supply_fan_run_command - - supply_fan_run_status + - bypass_air_damper_percentage_command + - supply_air_static_pressure_sensor + - supply_air_static_pressure_setpoint + - supply_fan_run_command + - supply_fan_run_status implements: - - CONTROL + - CONTROL BYPSSPC2X: # Consider virtual point for instances where dampers control to same value. guid: "f4de1232-617b-49c9-adc9-be8810631dbc" description: "Supply static pressure control with bypass damper." is_abstract: true opt_uses: - - supply_air_flowrate_sensor - - failed_supply_fan_alarm - - high_supply_air_static_pressure_alarm - - low_supply_air_static_pressure_alarm + - supply_air_flowrate_sensor + - failed_supply_fan_alarm + - high_supply_air_static_pressure_alarm + - low_supply_air_static_pressure_alarm uses: - - bypass_air_damper_percentage_command_1 - - bypass_air_damper_percentage_command_2 - - supply_air_static_pressure_sensor - - supply_air_static_pressure_setpoint - - supply_fan_run_command - - supply_fan_run_status + - bypass_air_damper_percentage_command_1 + - bypass_air_damper_percentage_command_2 + - supply_air_static_pressure_sensor + - supply_air_static_pressure_setpoint + - supply_fan_run_command + - supply_fan_run_status implements: - - CONTROL + - CONTROL SWISOVM: guid: "650f3451-5e49-4161-b257-cfc578fb54b4" description: "Supply side isolation valve monitoring." is_abstract: true uses: - - supply_water_isolation_valve_command - - supply_water_isolation_valve_status + - supply_water_isolation_valve_command + - supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING opt_uses: - - failed_isolation_valve_alarm - - local_override_isolation_valve_alarm + - failed_isolation_valve_alarm + - local_override_isolation_valve_alarm SWISOVPM: guid: "33856563-ebe5-42ee-a928-e8b46d81772d" description: "Supply side isolation valve monitoring." is_abstract: true uses: - - supply_water_isolation_valve_percentage_command - - supply_water_isolation_valve_percentage_sensor + - supply_water_isolation_valve_percentage_command + - supply_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING RWISOVM: guid: "2d35bbb0-bcad-4f36-a8cb-0c9031d81886" description: "Return side isolation valve monitoring." is_abstract: true uses: - - return_water_isolation_valve_command - - return_water_isolation_valve_status + - return_water_isolation_valve_command + - return_water_isolation_valve_status implements: - - MONITORING + - MONITORING RWISOVPM: guid: "a20fce9d-f8c0-4324-9ffd-8aaa3729b32d" description: "Return side isolation valve monitoring." is_abstract: true uses: - - return_water_isolation_valve_percentage_command - - return_water_isolation_valve_percentage_sensor + - return_water_isolation_valve_percentage_command + - return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING CICHVISOVM3X: guid: "2fb6be93-58f7-4544-ad33-bae7bf47ff0a" description: "Circuit changeover valve for switching between Hot water system and Chiller " is_abstract: true uses: - - circulation_changeover_isolation_valve_status_1 - - circulation_changeover_isolation_valve_status_2 - - circulation_changeover_isolation_valve_status_3 + - circulation_changeover_isolation_valve_status_1 + - circulation_changeover_isolation_valve_status_2 + - circulation_changeover_isolation_valve_status_3 implements: - - MONITORING + - MONITORING CHWRWISOVPM: guid: "0a8333ee-fdc9-440b-9ebc-fb0e19e8cf5c" description: "Return side isolation valve monitoring." is_abstract: true uses: - - chilled_return_water_isolation_valve_percentage_command - - chilled_return_water_isolation_valve_percentage_sensor + - chilled_return_water_isolation_valve_percentage_command + - chilled_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING CHWRWISOVM: guid: "e9680821-b425-4b3f-bef2-b89795524460" description: "Return side isolation valve monitoring." is_abstract: true uses: - - chilled_return_water_isolation_valve_command - - chilled_return_water_isolation_valve_status + - chilled_return_water_isolation_valve_command + - chilled_return_water_isolation_valve_status implements: - - MONITORING + - MONITORING CHWSWISOVPM: guid: "5f1963bf-1148-4881-8c6f-a20b39600e7e" description: "Supply side isolation valve monitoring." is_abstract: true uses: - - chilled_supply_water_isolation_valve_percentage_command - - chilled_supply_water_isolation_valve_percentage_sensor + - chilled_supply_water_isolation_valve_percentage_command + - chilled_supply_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING CHWSWISOVM: guid: "1a187792-767f-4132-9333-161c6db07ce4" description: "Supply side isolation valve monitoring." is_abstract: true uses: - - chilled_supply_water_isolation_valve_command - - chilled_supply_water_isolation_valve_status + - chilled_supply_water_isolation_valve_command + - chilled_supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING PRWDT: guid: "cc3605dc-b8bc-4e50-a97c-6a450040bda1" description: "Temperature differential across process water." is_abstract: true implements: - - MONITORING + - MONITORING opt_uses: - - process_cooling_thermal_power_sensor + - process_cooling_thermal_power_sensor uses: - - process_return_water_temperature_sensor - - process_supply_water_temperature_sensor + - process_return_water_temperature_sensor + - process_supply_water_temperature_sensor PRWDT2X: guid: "a84edaa6-abe2-4496-9d44-9d5210573b13" description: "Temperature differential across 2 process water headers." is_abstract: true implements: - - MONITORING + - MONITORING opt_uses: - - process_cooling_thermal_power_sensor_1 - - process_cooling_thermal_power_sensor_2 + - process_cooling_thermal_power_sensor_1 + - process_cooling_thermal_power_sensor_2 uses: - - process_return_water_temperature_sensor_1 - - process_return_water_temperature_sensor_2 - - process_supply_water_temperature_sensor_1 - - process_supply_water_temperature_sensor_2 + - process_return_water_temperature_sensor_1 + - process_return_water_temperature_sensor_2 + - process_supply_water_temperature_sensor_1 + - process_supply_water_temperature_sensor_2 PWFRM: guid: "617bdc3e-24b2-4e1f-b03e-9a179ce4fccd" description: "Flowrate monitoring for process water." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - process_water_flowrate_sensor + - process_water_flowrate_sensor PWFRM2X: guid: "7ee01573-42e1-4b4b-9dae-8c4950ce6e29" description: "Flowrate monitoring for 2 process water headers." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - process_water_flowrate_sensor_1 - - process_water_flowrate_sensor_2 + - process_water_flowrate_sensor_1 + - process_water_flowrate_sensor_2 PWDPM: guid: "f6ba0e90-e329-4170-96db-1b0ea822db23" description: "Differential pressure monitoring for process water." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - process_water_differential_pressure_sensor + - process_water_differential_pressure_sensor PWDPM2X: guid: "95241eea-6d22-400c-aa92-c0e7caf8a4d1" description: "Differential pressure monitoring for 2 process water headers." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - process_water_differential_pressure_sensor_1 - - process_water_differential_pressure_sensor_2 + - process_water_differential_pressure_sensor_1 + - process_water_differential_pressure_sensor_2 CWRISOVPM: guid: "ec4e3b78-417d-47a3-bbbf-d031f31d2d3d" description: "Condensing water return isolation monitoring." is_abstract: true uses: - - condensing_return_water_isolation_valve_percentage_command - - condensing_return_water_isolation_valve_percentage_sensor + - condensing_return_water_isolation_valve_percentage_command + - condensing_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING CWRISOVM: guid: "cb8b8c1e-30c2-48fc-b6c0-44d73468d994" description: "Condensing water return isolation monitoring." is_abstract: true uses: - - condensing_return_water_isolation_valve_command - - condensing_return_water_isolation_valve_status + - condensing_return_water_isolation_valve_command + - condensing_return_water_isolation_valve_status implements: - - MONITORING + - MONITORING CWSISOVPM: guid: "3221aa75-8df4-4964-82dd-9a5c59c3a73b" description: "Condensing water supply isolation monitoring." is_abstract: true uses: - - condensing_supply_water_isolation_valve_percentage_command - - condensing_supply_water_isolation_valve_percentage_sensor + - condensing_supply_water_isolation_valve_percentage_command + - condensing_supply_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING CWSISOVM: guid: "6284c4c0-1261-44f7-bebb-ab6aa11443ca" description: "Condensing water supply isolation monitoring." is_abstract: true uses: - - condensing_supply_water_isolation_valve_command - - condensing_supply_water_isolation_valve_status + - condensing_supply_water_isolation_valve_command + - condensing_supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING CHWRISOVPM: guid: "e9fd8609-a3da-4c2a-bd3b-df8692285add" description: "Chilled water return isolation monitoring." is_abstract: true uses: - - chilled_return_water_isolation_valve_percentage_command - - chilled_return_water_isolation_valve_percentage_sensor + - chilled_return_water_isolation_valve_percentage_command + - chilled_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING WDPM: guid: "417a56f9-4c22-454a-8aa9-e6764d9fea8e" description: "Differential pressure monitoring." is_abstract: true uses: - - differential_pressure_sensor + - differential_pressure_sensor opt_uses: - - high_differential_pressure_alarm - - low_differential_pressure_alarm + - high_differential_pressure_alarm + - low_differential_pressure_alarm CHWDPM: guid: "dcdb66fc-576b-4475-a1cd-f143e16edcde" description: "Differential pressure monitoring for chilled water." is_abstract: true uses: - - chilled_water_differential_pressure_sensor + - chilled_water_differential_pressure_sensor CHDX4SC: guid: "52c7a4a2-d587-46d5-96c9-d1bdf60daa81" description: "Chiller control." is_abstract: true opt_uses: - - chilled_return_water_temperature_sensor - - compressor_speed_frequency_sensor - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - cooling_percentage_command + - chilled_return_water_temperature_sensor + - compressor_speed_frequency_sensor + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - cooling_percentage_command uses: - - chilled_supply_water_temperature_sensor - - chilled_supply_water_temperature_setpoint - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 + - chilled_supply_water_temperature_sensor + - chilled_supply_water_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 CHDX2SC: guid: "7383de4b-4fcd-4504-b91a-3fd2576845fb" description: "Chiller control." is_abstract: true opt_uses: - - chilled_return_water_temperature_sensor - - compressor_speed_frequency_sensor - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - cooling_percentage_command - - cooling_request_count + - chilled_return_water_temperature_sensor + - compressor_speed_frequency_sensor + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - cooling_percentage_command + - cooling_request_count uses: - - chilled_supply_water_temperature_sensor - - chilled_supply_water_temperature_setpoint - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 + - chilled_supply_water_temperature_sensor + - chilled_supply_water_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 CHDXSC: guid: "cc5a8afe-0752-4b8d-846a-5848bf056ddd" description: "Chiller control single stage." is_abstract: true opt_uses: - - chilled_return_water_temperature_sensor - - compressor_speed_frequency_sensor - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - cooling_percentage_command - - compressor_lost_power_alarm - - failed_compressor_alarm - - overload_compressor_alarm + - chilled_return_water_temperature_sensor + - compressor_speed_frequency_sensor + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - cooling_percentage_command + - compressor_lost_power_alarm + - failed_compressor_alarm + - overload_compressor_alarm uses: - - chilled_supply_water_temperature_sensor - - chilled_supply_water_temperature_setpoint - - compressor_run_command - - compressor_run_status + - chilled_supply_water_temperature_sensor + - chilled_supply_water_temperature_setpoint + - compressor_run_command + - compressor_run_status CHDXVSC: guid: "7a5e238a-a1b2-4aac-88e3-cffc18960489" description: "Variable speed compressor control." is_abstract: true uses: - - compressor_run_command - - compressor_run_status - - compressor_speed_percentage_sensor + - compressor_run_command + - compressor_run_status + - compressor_speed_percentage_sensor opt_uses: - - compressor_current_sensor - - compressor_speed_frequency_sensor - - compressor_voltage_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - overload_compressor_alarm + - compressor_current_sensor + - compressor_speed_frequency_sensor + - compressor_voltage_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - overload_compressor_alarm CDWFRM: guid: "b4cd6a63-df02-4c7b-bf81-3902cd827241" description: "Condenser water flowrate monitoring." is_abstract: true uses: - - condensing_water_flowrate_sensor + - condensing_water_flowrate_sensor implements: - - MONITORING + - MONITORING REFSM: guid: "dfcadf28-6b6f-405b-b6f9-c6ac4f445e96" description: "Refrigerant saturation monitoring." is_abstract: true opt_uses: - - refrigerant_discharge_temperature_sensor - - refrigerant_suction_temperature_sensor + - refrigerant_discharge_temperature_sensor + - refrigerant_suction_temperature_sensor uses: - - refrigerant_condenser_saturation_temperature_sensor - - refrigerant_evaporator_saturation_temperature_sensor + - refrigerant_condenser_saturation_temperature_sensor + - refrigerant_evaporator_saturation_temperature_sensor implements: - - MONITORING + - MONITORING PDSCV: guid: "b1eac019-247c-4669-bd66-f70f262f9af7" description: "Pressure-dependent supply damper control for ventilation purposes (CO2 or VOC)." is_abstract: true uses: - - supply_air_damper_percentage_command - - supply_air_damper_percentage_sensor + - supply_air_damper_percentage_command + - supply_air_damper_percentage_sensor implements: - - CONTROL + - CONTROL SDBPC: guid: "881f3d79-d107-4268-83c6-f16e3ae7fb5a" description: "Back-pressure controlling supply damper." is_abstract: true opt_uses: - - supply_air_flowrate_sensor - - high_supply_air_static_pressure_alarm - - low_supply_air_static_pressure_alarm + - supply_air_flowrate_sensor + - high_supply_air_static_pressure_alarm + - low_supply_air_static_pressure_alarm uses: - - supply_air_damper_percentage_command - - supply_air_damper_percentage_sensor - - supply_air_static_pressure_sensor - - supply_air_static_pressure_setpoint + - supply_air_damper_percentage_command + - supply_air_damper_percentage_sensor + - supply_air_static_pressure_sensor + - supply_air_static_pressure_setpoint implements: - - MONITORING + - MONITORING HWVM: guid: "9e86fa93-01d8-4536-815b-1b031b165f3f" description: "Heating water valve command and position monitoring (without regard to what controls it)." is_abstract: true opt_uses: - - heating_thermal_power_capacity - - heating_water_flowrate_sensor + - heating_thermal_power_capacity + - heating_water_flowrate_sensor uses: - - heating_water_valve_percentage_command - - heating_water_valve_percentage_sensor + - heating_water_valve_percentage_command + - heating_water_valve_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL CHWVM: guid: "73411f3e-5c42-40cb-8d6c-82f1e2358844" description: "Chilled water valve command and position monitoring (without regard to what controls it)." is_abstract: true opt_uses: - - chilled_water_flowrate_sensor - - cooling_thermal_power_capacity - - failed_chilled_water_valve_alarm + - chilled_water_flowrate_sensor + - cooling_thermal_power_capacity + - failed_chilled_water_valve_alarm uses: - - chilled_water_valve_percentage_command - - chilled_water_valve_percentage_sensor + - chilled_water_valve_percentage_command + - chilled_water_valve_percentage_sensor implements: - - OPERATIONAL + - OPERATIONAL RMM: guid: "162df361-7593-4e36-bf41-e7fa667244dd" description: "Run mode monitoring." is_abstract: true uses: - - run_mode + - run_mode DSPZDHC: guid: "365e7bc0-cc71-4fdd-937c-c8be0011636e" description: "Zone dual setpoint humidification/dehumidification control." is_abstract: true opt_uses: - - humidification_percentage_command - - failed_humidifier_alarm + - humidification_percentage_command + - failed_humidifier_alarm uses: - - dehumidification_run_command - - humidification_run_command - - zone_air_dehumidification_relative_humidity_setpoint - - zone_air_humidification_relative_humidity_setpoint - - zone_air_relative_humidity_sensor + - dehumidification_run_command + - humidification_run_command + - zone_air_dehumidification_relative_humidity_setpoint + - zone_air_humidification_relative_humidity_setpoint + - zone_air_relative_humidity_sensor implements: - - CONTROL + - CONTROL EFC: guid: "12587490-2e23-4c9c-9b4f-6980f855ed41" description: "Exhaust air flow control." is_abstract: true uses: - - exhaust_air_flowrate_sensor - - exhaust_air_flowrate_setpoint + - exhaust_air_flowrate_sensor + - exhaust_air_flowrate_setpoint implements: - - OPERATIONAL + - OPERATIONAL DXDDC: guid: "a3f8ff4c-3cfc-4832-a0f3-1526c82b4e9e" description: "DX cooling dual setpoint control on discharge side" is_abstract: true opt_uses: - - compressor_run_status - - cooling_percentage_command - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - overload_compressor_alarm + - compressor_run_status + - cooling_percentage_command + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - discharge_air_cooling_temperature_setpoint - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor + - compressor_run_command + - discharge_air_cooling_temperature_setpoint + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor implements: - - CONTROL + - CONTROL HTDDC: guid: "9e35fc23-e57e-461a-8ad0-09d91a86bb78" description: "gas or electric heating dual setpoint control on discharge side" is_abstract: true opt_uses: - - heater_run_status - - heating_percentage_command - - failed_discharge_air_temperature_alarm + - heater_run_status + - heating_percentage_command + - failed_discharge_air_temperature_alarm uses: - - discharge_air_cooling_temperature_setpoint - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor - - heater_run_command + - discharge_air_cooling_temperature_setpoint + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor + - heater_run_command implements: - - CONTROL + - CONTROL REFSM2X: guid: "4690aaf5-e70c-43e0-aabb-38d209b8c2aa" description: "Refrigerant temperature monitoring for 2 circuits." is_abstract: true opt_uses: - - refrigerant_discharge_temperature_sensor_1 - - refrigerant_discharge_temperature_sensor_2 - - refrigerant_suction_temperature_sensor_1 - - refrigerant_suction_temperature_sensor_2 + - refrigerant_discharge_temperature_sensor_1 + - refrigerant_discharge_temperature_sensor_2 + - refrigerant_suction_temperature_sensor_1 + - refrigerant_suction_temperature_sensor_2 uses: - - refrigerant_condenser_saturation_temperature_sensor_1 - - refrigerant_condenser_saturation_temperature_sensor_2 - - refrigerant_evaporator_saturation_temperature_sensor_1 - - refrigerant_evaporator_saturation_temperature_sensor_2 + - refrigerant_condenser_saturation_temperature_sensor_1 + - refrigerant_condenser_saturation_temperature_sensor_2 + - refrigerant_evaporator_saturation_temperature_sensor_1 + - refrigerant_evaporator_saturation_temperature_sensor_2 implements: - - MONITORING + - MONITORING REFPM: guid: "a2aeaac3-35be-4e06-89fe-560d7ec5935e" description: "Refrigerant pressure monitoring for single circuits." is_abstract: true opt_uses: - - refrigerant_differential_pressure_sensor - - refrigerant_high_pressure_status - - refrigerant_low_pressure_status + - refrigerant_differential_pressure_sensor + - refrigerant_high_pressure_status + - refrigerant_low_pressure_status uses: - - refrigerant_condenser_pressure_sensor - - refrigerant_evaporator_pressure_sensor + - refrigerant_condenser_pressure_sensor + - refrigerant_evaporator_pressure_sensor implements: - - MONITORING + - MONITORING REFPM2X: guid: "6f2fadec-2b16-4410-8fb5-f6e52c6f13e4" description: "Refrigerant pressure monitoring for 2 circuits." is_abstract: true uses: - - refrigerant_condenser_pressure_sensor_1 - - refrigerant_condenser_pressure_sensor_2 - - refrigerant_evaporator_pressure_sensor_1 - - refrigerant_evaporator_pressure_sensor_2 + - refrigerant_condenser_pressure_sensor_1 + - refrigerant_condenser_pressure_sensor_2 + - refrigerant_evaporator_pressure_sensor_1 + - refrigerant_evaporator_pressure_sensor_2 implements: - - MONITORING + - MONITORING SWPSS: guid: "0647053a-4f19-483a-9ad4-4dc4d1472775" description: "Sweeper pump start stop monitoring." is_abstract: true uses: - - sweeper_pump_run_command - - sweeper_pump_run_status + - sweeper_pump_run_command + - sweeper_pump_run_status implements: - - OPERATIONAL + - OPERATIONAL DRPM: guid: "ae1c0c1a-981c-4a56-9640-afd961cf0f9a" description: "Drain pump monitoring." is_abstract: true opt_uses: - - input_motor_power_status - - water_high_level_status - - water_low_level_status - - failed_drain_pump_alarm + - input_motor_power_status + - water_high_level_status + - water_low_level_status + - failed_drain_pump_alarm uses: - - drain_pump_run_status + - drain_pump_run_status implements: - - MONITORING + - MONITORING SDM: guid: "40dc57c7-1efd-483d-a2c0-46077595b2b8" description: "Supply air damper monitoring." is_abstract: true uses: - - supply_air_damper_command - - supply_air_damper_status + - supply_air_damper_command + - supply_air_damper_status ECDDC: guid: "4874434d-75fd-4a18-aca5-70851c77ea0b" description: "Evaporative cooler control on discharge side." is_abstract: true opt_uses: - - cooling_percentage_sensor - - evaporative_cooler_run_status - - failed_discharge_air_temperature_alarm + - cooling_percentage_sensor + - evaporative_cooler_run_status + - failed_discharge_air_temperature_alarm uses: - - discharge_air_cooling_temperature_setpoint - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor - - evaporative_cooler_run_command + - discharge_air_cooling_temperature_setpoint + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor + - evaporative_cooler_run_command implements: - - CONTROL + - CONTROL DXSDC: guid: "ea721fc2-16b9-4bb9-9b59-09c9e1ae1362" description: "Compressor run control on supply side, dual setpoints." is_abstract: true opt_uses: - - compressor_run_status - - compressor_speed_percentage_command - - cooling_percentage_command #Serves as a duty cycle for single-stage DX sections. - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - - overload_compressor_alarm + - compressor_run_status + - compressor_speed_percentage_command + - cooling_percentage_command #Serves as a duty cycle for single-stage DX sections. + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - supply_air_cooling_temperature_setpoint - - supply_air_heating_temperature_setpoint - - supply_air_temperature_sensor + - compressor_run_command + - supply_air_cooling_temperature_setpoint + - supply_air_heating_temperature_setpoint + - supply_air_temperature_sensor implements: - - CONTROL + - CONTROL ETM4X: guid: "56fb8b0b-74c6-47be-ad97-189b89c4c78a" description: "Basic exhaust temperature monitoring." is_abstract: true uses: - - exhaust_air_temperature_sensor_1 - - exhaust_air_temperature_sensor_2 - - exhaust_air_temperature_sensor_3 - - exhaust_air_temperature_sensor_4 + - exhaust_air_temperature_sensor_1 + - exhaust_air_temperature_sensor_2 + - exhaust_air_temperature_sensor_3 + - exhaust_air_temperature_sensor_4 implements: - - MONITORING + - MONITORING DX6SC: guid: "f2fed45c-84e5-4905-b01d-5397cffb7a0e" description: "Six compressor run control on supply air side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_request_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_command_5 - - compressor_run_command_6 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - compressor_run_status_5 - - compressor_run_status_6 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint - implements: - - CONTROL + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_request_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + uses: + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_command_5 + - compressor_run_command_6 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - compressor_run_status_5 + - compressor_run_status_6 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint + implements: + - CONTROL DX2DSPRTC: guid: "d0ac0571-5f48-464c-bd43-dc58ac879fa9" description: "Two-stage compressor run control with dual return temp control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_stage_run_count - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_stage_run_count + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - return_air_cooling_temperature_setpoint - - return_air_heating_temperature_setpoint - - return_air_temperature_sensor + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - return_air_cooling_temperature_setpoint + - return_air_heating_temperature_setpoint + - return_air_temperature_sensor implements: - - CONTROL + - CONTROL HPDSPRTC: guid: "211fecae-8082-4a69-b27d-e39cdaf65362" description: "Heat pump run control with dual return temp control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - discharge_air_temperature_sensor - - leaving_cooling_coil_temperature_sensor - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - discharge_air_temperature_sensor + - leaving_cooling_coil_temperature_sensor + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - reversing_valve_command - - return_air_cooling_temperature_setpoint - - return_air_heating_temperature_setpoint - - return_air_temperature_sensor + - compressor_run_command + - compressor_run_status + - reversing_valve_command + - return_air_cooling_temperature_setpoint + - return_air_heating_temperature_setpoint + - return_air_temperature_sensor implements: - - CONTROL + - CONTROL DX4DC: guid: "f833b8eb-fdb9-4680-893f-77f87a0a991e" description: "Compressor run control on discharge air side (DTC)." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - leaving_cooling_coil_temperature_sensor - - failed_discharge_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - leaving_cooling_coil_temperature_sensor + - failed_discharge_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint implements: - - CONTROL + - CONTROL DX6SWC: guid: "8b0ee974-bc6c-445f-9f5a-25b311e80740" description: "Six compressor run control on supply water side." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - compressor_speed_percentage_sensor - - cooling_percentage_command - - cooling_thermal_power_capacity - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm - uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_command_3 - - compressor_run_command_4 - - compressor_run_command_5 - - compressor_run_command_6 - - compressor_run_status_1 - - compressor_run_status_2 - - compressor_run_status_3 - - compressor_run_status_4 - - compressor_run_status_5 - - compressor_run_status_6 - - supply_water_temperature_sensor - - supply_water_temperature_setpoint - implements: - - CONTROL + - compressor_speed_percentage_command + - compressor_speed_percentage_sensor + - cooling_percentage_command + - cooling_thermal_power_capacity + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm + uses: + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_command_3 + - compressor_run_command_4 + - compressor_run_command_5 + - compressor_run_command_6 + - compressor_run_status_1 + - compressor_run_status_2 + - compressor_run_status_3 + - compressor_run_status_4 + - compressor_run_status_5 + - compressor_run_status_6 + - supply_water_temperature_sensor + - supply_water_temperature_setpoint + implements: + - CONTROL DRSM5X: guid: "24163e23-9488-4804-9d07-9a40ae3f693e" description: "Dryer status monitoring." is_abstract: true uses: - - dryer_run_status_1 - - dryer_run_status_2 - - dryer_run_status_3 - - dryer_run_status_4 - - dryer_run_status_5 + - dryer_run_status_1 + - dryer_run_status_2 + - dryer_run_status_3 + - dryer_run_status_4 + - dryer_run_status_5 implements: - - MONITORING + - MONITORING DRSM8X: guid: "69f3f878-0bf0-4544-adbc-2192ac3b6138" description: "Dryer status monitoring." is_abstract: true uses: - - dryer_run_status_1 - - dryer_run_status_2 - - dryer_run_status_3 - - dryer_run_status_4 - - dryer_run_status_5 - - dryer_run_status_6 - - dryer_run_status_7 - - dryer_run_status_8 + - dryer_run_status_1 + - dryer_run_status_2 + - dryer_run_status_3 + - dryer_run_status_4 + - dryer_run_status_5 + - dryer_run_status_6 + - dryer_run_status_7 + - dryer_run_status_8 implements: - - MONITORING + - MONITORING AHAC: guid: "f34854e7-cf5e-4477-baaa-e72f80a28bcd" description: "Tag to indicate an after hours activation method e.g. push button associated with this device." is_abstract: true uses: - - user_occupancy_override_status - - zone_occupancy_status + - user_occupancy_override_status + - zone_occupancy_status implements: - - OPERATIONAL + - OPERATIONAL DFFC: guid: "118449f6-f7e1-4c5b-ab15-fe67d43a2718" description: "Discharge fan flow control" is_abstract: true uses: - - discharge_air_flowrate_sensor - - discharge_air_flowrate_setpoint - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_percentage_command + - discharge_air_flowrate_sensor + - discharge_air_flowrate_setpoint + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_percentage_command implements: - - CONTROL + - CONTROL opt_uses: - - failed_discharge_fan_alarm - - low_discharge_air_flowrate_alarm + - failed_discharge_fan_alarm + - low_discharge_air_flowrate_alarm EFM: guid: "2dba33f6-54ef-47eb-93ca-d8892ee84a06" description: "Exhaust air flow monitoring" is_abstract: true uses: - - exhaust_air_flowrate_sensor + - exhaust_air_flowrate_sensor implements: - - OPERATIONAL + - OPERATIONAL SWTM: guid: "353200de-deca-44b5-a664-e725c857a24f" description: "Supply water temperature monitoring." is_abstract: true implements: - - MONITORING + - MONITORING opt_uses: - - cooling_request_count - - heating_request_count - - return_water_temperature_sensor - - high_supply_water_temperature_alarm - - low_supply_water_temperature_alarm + - cooling_request_count + - heating_request_count + - return_water_temperature_sensor + - high_supply_water_temperature_alarm + - low_supply_water_temperature_alarm uses: - - supply_water_temperature_sensor + - supply_water_temperature_sensor CWDPM: guid: "d71e1e0d-35d6-4b53-a570-2e12959c951b" description: "Differential pressure monitoring for condenser water." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - condensing_water_differential_pressure_sensor + - condensing_water_differential_pressure_sensor DICM: guid: "0c42ee3c-eb6c-4624-a4ab-4f8f0f483778" description: "Damper isolation control and monitoring. " is_abstract: true uses: - - supply_air_isolation_damper_closed_status - - supply_air_isolation_damper_command - - supply_air_isolation_damper_open_status + - supply_air_isolation_damper_closed_status + - supply_air_isolation_damper_command + - supply_air_isolation_damper_open_status UV: guid: "6f7a15ff-40b1-4c49-b70b-18e409db171b" description: "Ultraviolet lamp operation." is_abstract: true opt_uses: - - ultraviolet_lamp_run_mode + - ultraviolet_lamp_run_mode uses: - - ultraviolet_lamp_run_command - - ultraviolet_lamp_run_status + - ultraviolet_lamp_run_command + - ultraviolet_lamp_run_status H3X: guid: "dd956d92-525a-4970-86f8-c48ed8e5282a" description: "Heater monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - heater_run_command_1 - - heater_run_command_2 - - heater_run_command_3 - - heater_run_status_1 - - heater_run_status_2 - - heater_run_status_3 + - heater_run_command_1 + - heater_run_command_2 + - heater_run_command_3 + - heater_run_status_1 + - heater_run_status_2 + - heater_run_status_3 CHWBRC: guid: "4732dcec-2cab-418e-8c7c-d805f86905e7" description: "Chilled water valve binary (open/closed) monitoring/controlling. Return air temperature control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - chilled_water_valve_command - - return_air_temperature_sensor - - return_air_temperature_setpoint + - chilled_water_valve_command + - return_air_temperature_sensor + - return_air_temperature_setpoint opt_uses: - - failed_chilled_water_valve_alarm - - high_return_air_temperature_alarm - - low_return_air_temperature_alarm + - failed_chilled_water_valve_alarm + - high_return_air_temperature_alarm + - low_return_air_temperature_alarm CHWISOVPM: guid: "d9f7e2fd-391e-48cf-9483-f3f6e19b1b6d" description: "Chllled water isolation valve control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - chilled_water_isolation_valve_percentage_command - - chilled_water_isolation_valve_percentage_sensor + - chilled_water_isolation_valve_percentage_command + - chilled_water_isolation_valve_percentage_sensor CWCS: guid: "e186aea0-5702-4c18-b384-0d95851764c2" description: "Condensing water valve control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - condensing_water_valve_percentage_command - - condensing_water_valve_percentage_sensor + - condensing_water_valve_percentage_command + - condensing_water_valve_percentage_sensor DPM: guid: "b848804b-3954-4982-9333-5232eae0bd00" description: "Damper percentage control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - damper_percentage_command - - damper_percentage_sensor + - damper_percentage_command + - damper_percentage_sensor DFVSMC: guid: "1e59e4d6-d645-4685-b1a5-e113d5e2100f" description: "Variable speed control mode for discharge fans." is_abstract: true uses: - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_mode + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_mode implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - failed_discharge_fan_alarm + - failed_discharge_fan_alarm DFVDSC: guid: "38648763-53c2-4464-9133-b42d40dcead3" description: "Discharge fan control with toggled variable or discrete speed control. This allows the fan to run either VFD or discrete speed stages (LOW/MED/HIGH, etc.) and to switch between the mode." is_abstract: true uses: - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_mode - - discharge_fan_speed_percentage_command + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_mode + - discharge_fan_speed_percentage_command implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - failed_discharge_fan_alarm + - failed_discharge_fan_alarm DFVDSFC: guid: "a59a9de7-dd3b-4503-b4fe-49a747fd4a32" description: "Discharge fan control with toggled variable or discrete speed (frequency) control. This allows the fan to run either VFD or discrete speed stages (LOW/MED/HIGH, etc.) and to switch between the mode." is_abstract: true uses: - - discharge_fan_run_command - - discharge_fan_run_status - - discharge_fan_speed_frequency_command - - discharge_fan_speed_mode + - discharge_fan_run_command + - discharge_fan_run_status + - discharge_fan_speed_frequency_command + - discharge_fan_speed_mode implements: - - OPERATIONAL + - OPERATIONAL opt_uses: - - failed_discharge_fan_alarm + - failed_discharge_fan_alarm SSPCSCM: guid: "68f3b34c-09a7-45d5-ad58-79ae6bd78e0b" description: "Supply air static pressure control for supervisor control (Machine learning)." is_abstract: true uses: - - program_supply_air_static_pressure_setpoint - - supervisor_control_mode - - supervisor_supply_air_static_pressure_setpoint - - supply_air_static_pressure_setpoint + - program_supply_air_static_pressure_setpoint + - supervisor_control_mode + - supervisor_supply_air_static_pressure_setpoint + - supply_air_static_pressure_setpoint opt_uses: - - supervisor_alarm + - supervisor_alarm STCSCM: guid: "73c2d23e-eb23-41eb-8b1e-f657a2e6fc89" description: "Supply air temperature control for supervisor control (Machine learning)." is_abstract: true uses: - - program_supply_air_temperature_setpoint - - supervisor_control_mode - - supervisor_supply_air_temperature_setpoint - - supply_air_temperature_setpoint + - program_supply_air_temperature_setpoint + - supervisor_control_mode + - supervisor_supply_air_temperature_setpoint + - supply_air_temperature_setpoint opt_uses: - - supervisor_alarm + - supervisor_alarm SWTCSCM: guid: "f612f2d0-4b59-4036-ba7d-c1398d12de27" description: "Supply water temperature control for supervisor control (Machine learning)." is_abstract: true uses: - - program_supply_water_temperature_setpoint - - supervisor_control_mode - - supervisor_supply_water_temperature_setpoint - - supply_water_temperature_setpoint + - program_supply_water_temperature_setpoint + - supervisor_control_mode + - supervisor_supply_water_temperature_setpoint + - supply_water_temperature_setpoint opt_uses: - - supervisor_alarm + - supervisor_alarm WDPCSCM: guid: "40d1d42d-50b9-4c13-8213-fa836e3069de" description: "Water differential pressure control for supervisor control (Machine learning)." is_abstract: true uses: - - differential_pressure_setpoint - - program_differential_pressure_setpoint - - supervisor_control_mode - - supervisor_differential_pressure_setpoint + - differential_pressure_setpoint + - program_differential_pressure_setpoint + - supervisor_control_mode + - supervisor_differential_pressure_setpoint opt_uses: - - supervisor_alarm + - supervisor_alarm CSWIVS: guid: "e1e35fec-c621-4346-9992-4c85d31acaac" description: "Condensing return water isolation valve control." is_abstract: true implements: - - OPERATIONAL - uses: - - condensing_return_water_isolation_valve_command_1 - - condensing_return_water_isolation_valve_command_2 - - condensing_return_water_isolation_valve_command_3 - - condensing_return_water_isolation_valve_command_4 - - condensing_return_water_isolation_valve_command_5 - - condensing_return_water_isolation_valve_command_6 - - condensing_return_water_isolation_valve_command_7 - - condensing_return_water_isolation_valve_status_1 - - condensing_return_water_isolation_valve_status_10 - - condensing_return_water_isolation_valve_status_11 - - condensing_return_water_isolation_valve_status_12 - - condensing_return_water_isolation_valve_status_13 - - condensing_return_water_isolation_valve_status_14 - - condensing_return_water_isolation_valve_status_2 - - condensing_return_water_isolation_valve_status_3 - - condensing_return_water_isolation_valve_status_4 - - condensing_return_water_isolation_valve_status_5 - - condensing_return_water_isolation_valve_status_6 - - condensing_return_water_isolation_valve_status_7 - - condensing_return_water_isolation_valve_status_8 - - condensing_return_water_isolation_valve_status_9 + - OPERATIONAL + uses: + - condensing_return_water_isolation_valve_command_1 + - condensing_return_water_isolation_valve_command_2 + - condensing_return_water_isolation_valve_command_3 + - condensing_return_water_isolation_valve_command_4 + - condensing_return_water_isolation_valve_command_5 + - condensing_return_water_isolation_valve_command_6 + - condensing_return_water_isolation_valve_command_7 + - condensing_return_water_isolation_valve_status_1 + - condensing_return_water_isolation_valve_status_10 + - condensing_return_water_isolation_valve_status_11 + - condensing_return_water_isolation_valve_status_12 + - condensing_return_water_isolation_valve_status_13 + - condensing_return_water_isolation_valve_status_14 + - condensing_return_water_isolation_valve_status_2 + - condensing_return_water_isolation_valve_status_3 + - condensing_return_water_isolation_valve_status_4 + - condensing_return_water_isolation_valve_status_5 + - condensing_return_water_isolation_valve_status_6 + - condensing_return_water_isolation_valve_status_7 + - condensing_return_water_isolation_valve_status_8 + - condensing_return_water_isolation_valve_status_9 CRWIVS: guid: "8ea0f73c-6a13-4196-a63d-f68011597239" description: "Condensing supply water isolation valve control." is_abstract: true implements: - - OPERATIONAL - uses: - - condensing_supply_water_isolation_valve_command_1 - - condensing_supply_water_isolation_valve_command_2 - - condensing_supply_water_isolation_valve_command_3 - - condensing_supply_water_isolation_valve_command_4 - - condensing_supply_water_isolation_valve_command_5 - - condensing_supply_water_isolation_valve_command_6 - - condensing_supply_water_isolation_valve_command_7 - - condensing_supply_water_isolation_valve_status_1 - - condensing_supply_water_isolation_valve_status_10 - - condensing_supply_water_isolation_valve_status_11 - - condensing_supply_water_isolation_valve_status_12 - - condensing_supply_water_isolation_valve_status_13 - - condensing_supply_water_isolation_valve_status_14 - - condensing_supply_water_isolation_valve_status_2 - - condensing_supply_water_isolation_valve_status_3 - - condensing_supply_water_isolation_valve_status_4 - - condensing_supply_water_isolation_valve_status_5 - - condensing_supply_water_isolation_valve_status_6 - - condensing_supply_water_isolation_valve_status_7 - - condensing_supply_water_isolation_valve_status_8 - - condensing_supply_water_isolation_valve_status_9 + - OPERATIONAL + uses: + - condensing_supply_water_isolation_valve_command_1 + - condensing_supply_water_isolation_valve_command_2 + - condensing_supply_water_isolation_valve_command_3 + - condensing_supply_water_isolation_valve_command_4 + - condensing_supply_water_isolation_valve_command_5 + - condensing_supply_water_isolation_valve_command_6 + - condensing_supply_water_isolation_valve_command_7 + - condensing_supply_water_isolation_valve_status_1 + - condensing_supply_water_isolation_valve_status_10 + - condensing_supply_water_isolation_valve_status_11 + - condensing_supply_water_isolation_valve_status_12 + - condensing_supply_water_isolation_valve_status_13 + - condensing_supply_water_isolation_valve_status_14 + - condensing_supply_water_isolation_valve_status_2 + - condensing_supply_water_isolation_valve_status_3 + - condensing_supply_water_isolation_valve_status_4 + - condensing_supply_water_isolation_valve_status_5 + - condensing_supply_water_isolation_valve_status_6 + - condensing_supply_water_isolation_valve_status_7 + - condensing_supply_water_isolation_valve_status_8 + - condensing_supply_water_isolation_valve_status_9 CSWTC: guid: "1e4bca21-e4df-42e2-86ac-d3b2db91e7d2" description: "Condensing supply water temperature control." is_abstract: true implements: - - OPERATIONAL + - OPERATIONAL uses: - - condensing_supply_water_temperature_sensor - - condensing_supply_water_temperature_setpoint + - condensing_supply_water_temperature_sensor + - condensing_supply_water_temperature_setpoint HTWHLSTC: guid: "f05a9fca-0e82-41d5-bee2-2db157b5630b" description: "Heat wheel which controls supply temperature using speed control." is_abstract: true implements: - - CONTROL + - CONTROL opt_uses: - - exhaust_air_temperature_sensor - - heat_wheel_speed_percentage_sensor - - return_air_temperature_sensor - - failed_exhaust_air_temperature_alarm - - high_return_air_temperature_alarm - - high_supply_air_temperature_alarm - - low_return_air_temperature_alarm - - low_supply_air_temperature_alarm + - exhaust_air_temperature_sensor + - heat_wheel_speed_percentage_sensor + - return_air_temperature_sensor + - failed_exhaust_air_temperature_alarm + - high_return_air_temperature_alarm + - high_supply_air_temperature_alarm + - low_return_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - heat_wheel_run_command - - heat_wheel_run_status - - heat_wheel_speed_percentage_command - - outside_air_temperature_sensor - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - heat_wheel_run_command + - heat_wheel_run_status + - heat_wheel_speed_percentage_command + - outside_air_temperature_sensor + - supply_air_temperature_sensor + - supply_air_temperature_setpoint #New abstracts for CH ZRH EURD CAM: @@ -5065,9 +5065,9 @@ CAM: description: "ztc alarm monitoring based on moisture sensor on coil or in pan." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - condensate_water_alarm + - condensate_water_alarm DPHCC: guid: "4719b91a-9a90-4336-a6cb-8d2109d8e572" @@ -5077,311 +5077,311 @@ DPHCC: mode control to zone temperature (heating/cooling setpoint configuration)." is_abstract: true opt_uses: - - chilled_return_water_isolation_valve_percentage_command - - chilled_supply_water_isolation_valve_percentage_command - - heating_return_water_isolation_valve_percentage_command - - heating_supply_water_isolation_valve_percentage_command - - supply_water_valve_flowrate_sensor - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_conditioning_mode - - condensate_water_alarm - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - chilled_return_water_isolation_valve_percentage_command + - chilled_supply_water_isolation_valve_percentage_command + - heating_return_water_isolation_valve_percentage_command + - heating_supply_water_isolation_valve_percentage_command + - supply_water_valve_flowrate_sensor + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_conditioning_mode + - condensate_water_alarm + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - supply_water_valve_percentage_command - - water_riser_mode - - zone_air_temperature_sensor + - supply_water_valve_percentage_command + - water_riser_mode + - zone_air_temperature_sensor HHCDM: guid: "60e8ae3a-2331-40e2-828c-e9b61a560352" description: "Hydronic heating and cooling distribution monitoring" is_abstract: true implements: - - MONITORING + - MONITORING uses: - - chilled_return_water_isolation_valve_percentage_command - - chilled_supply_water_isolation_valve_percentage_command - - cooling_request_count - - heating_request_count - - heating_return_water_isolation_valve_percentage_command - - heating_supply_water_isolation_valve_percentage_command + - chilled_return_water_isolation_valve_percentage_command + - chilled_supply_water_isolation_valve_percentage_command + - cooling_request_count + - heating_request_count + - heating_return_water_isolation_valve_percentage_command + - heating_supply_water_isolation_valve_percentage_command opt_uses: - - average_zone_air_temperature_sensor + - average_zone_air_temperature_sensor HHRU: guid: "29f20adc-716d-43ce-81a7-3a8af3bc039d" description: "Hydronic heat recovery unit for ahu's with bypass valve and circulation pump" is_abstract: true implements: - - MONITORING + - MONITORING uses: - - return_air_temperature_sensor - - supply_air_temperature_sensor - - supply_air_temperature_setpoint - - supply_water_temperature_sensor - - supply_water_valve_percentage_command - - supply_water_valve_percentage_sensor + - return_air_temperature_sensor + - supply_air_temperature_sensor + - supply_air_temperature_setpoint + - supply_water_temperature_sensor + - supply_water_valve_percentage_command + - supply_water_valve_percentage_sensor opt_uses: - - exhaust_air_temperature_sensor - - outside_air_temperature_sensor - - failed_exhaust_air_temperature_alarm - - high_return_air_temperature_alarm - - high_supply_air_temperature_alarm - - high_supply_water_temperature_alarm - - low_return_air_temperature_alarm - - low_supply_air_temperature_alarm - - low_supply_water_temperature_alarm + - exhaust_air_temperature_sensor + - outside_air_temperature_sensor + - failed_exhaust_air_temperature_alarm + - high_return_air_temperature_alarm + - high_supply_air_temperature_alarm + - high_supply_water_temperature_alarm + - low_return_air_temperature_alarm + - low_supply_air_temperature_alarm + - low_supply_water_temperature_alarm PHRU: guid: "708f68a9-f6f6-4563-b3a0-9d8f17637ced" description: "heat recovery unit for ahu's with plate heat exchanger valve and bypass damper" is_abstract: true implements: - - MONITORING + - MONITORING uses: - - bypass_air_damper_percentage_command - - return_air_temperature_sensor - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - bypass_air_damper_percentage_command + - return_air_temperature_sensor + - supply_air_temperature_sensor + - supply_air_temperature_setpoint opt_uses: - - bypass_air_damper_command - - bypass_air_damper_status - - bypass_air_damper_percentage_sensor - - exhaust_air_temperature_sensor - - outside_air_temperature_sensor - - failed_exhaust_air_temperature_alarm - - high_return_air_temperature_alarm - - high_supply_air_temperature_alarm - - low_return_air_temperature_alarm - - low_supply_air_temperature_alarm + - bypass_air_damper_command + - bypass_air_damper_status + - bypass_air_damper_percentage_sensor + - exhaust_air_temperature_sensor + - outside_air_temperature_sensor + - failed_exhaust_air_temperature_alarm + - high_return_air_temperature_alarm + - high_supply_air_temperature_alarm + - low_return_air_temperature_alarm + - low_supply_air_temperature_alarm PHRUD: guid: "a43c1a7c-ec35-4eb8-8c3a-b6291ef79d31" description: "single zone heat recovery unit for ahu's with plate heat exchanger valve and bypass damper" is_abstract: true implements: - - MONITORING + - MONITORING uses: - - bypass_air_damper_percentage_command - - return_air_temperature_sensor - - discharge_air_temperature_sensor - - discharge_air_temperature_setpoint + - bypass_air_damper_percentage_command + - return_air_temperature_sensor + - discharge_air_temperature_sensor + - discharge_air_temperature_setpoint opt_uses: - - bypass_air_damper_command - - bypass_air_damper_status - - bypass_air_damper_percentage_sensor - - exhaust_air_temperature_sensor - - outside_air_temperature_sensor - - failed_exhaust_air_temperature_alarm - - high_return_air_temperature_alarm - - high_discharge_air_temperature_alarm - - low_return_air_temperature_alarm - - low_discharge_air_temperature_alarm + - bypass_air_damper_command + - bypass_air_damper_status + - bypass_air_damper_percentage_sensor + - exhaust_air_temperature_sensor + - outside_air_temperature_sensor + - failed_exhaust_air_temperature_alarm + - high_return_air_temperature_alarm + - high_discharge_air_temperature_alarm + - low_return_air_temperature_alarm + - low_discharge_air_temperature_alarm CHWDT2X: guid: "956a597b-e5e5-4c1c-9c06-834b7b8d28b4" description: "Temperature differential across chilled water with two sets of sensors." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - chilled_return_water_temperature_sensor_1 - - chilled_return_water_temperature_sensor_2 - - chilled_supply_water_temperature_sensor_1 - - chilled_supply_water_temperature_sensor_2 + - chilled_return_water_temperature_sensor_1 + - chilled_return_water_temperature_sensor_2 + - chilled_supply_water_temperature_sensor_1 + - chilled_supply_water_temperature_sensor_2 HLSAFS: guid: "15bc5aa4-939f-420f-9146-17f6835badc0" description: "Duct VAV type with high and low limit setpoint" is_abstract: true uses: - - high_limit_supply_air_flowrate_setpoint - - low_limit_supply_air_flowrate_setpoint - - supply_air_flowrate_setpoint + - high_limit_supply_air_flowrate_setpoint + - low_limit_supply_air_flowrate_setpoint + - supply_air_flowrate_setpoint implements: - - CONTROL + - CONTROL RHDHS: guid: "8b06668f-b1c3-4cda-9fc6-967d06239ae8" description: "Return humidification/dehumidification monitor." is_abstract: true uses: - - dehumidification_run_status - - humidification_run_status - - return_air_relative_humidity_sensor - - return_air_relative_humidity_setpoint + - dehumidification_run_status + - humidification_run_status + - return_air_relative_humidity_sensor + - return_air_relative_humidity_setpoint implements: - - MONITORING + - MONITORING opt_uses: - - failed_humidifier_alarm - - high_return_air_relative_humidity_alarm - - low_return_air_relative_humidity_alarm + - failed_humidifier_alarm + - high_return_air_relative_humidity_alarm + - low_return_air_relative_humidity_alarm CO2DFVSC: guid: "e52dd216-585b-447a-9f30-2efe9639f949" description: "Carbon dioxide levels controlled by a variable speed discharge fan." is_abstract: true uses: - - discharge_fan_speed_percentage_command - - zone_air_co2_concentration_sensor - - zone_air_co2_concentration_setpoint + - discharge_fan_speed_percentage_command + - zone_air_co2_concentration_sensor + - zone_air_co2_concentration_setpoint implements: - - CONTROL + - CONTROL opt_uses: - - high_zone_air_co2_concentration_alarm + - high_zone_air_co2_concentration_alarm CO2EFVSC: guid: "9100a54f-3a01-439a-b009-7b4df6bedc1c" description: "Carbon dioxide levels controlled by a variable speed exhaust fan." is_abstract: true opt_uses: - - exhaust_fan_speed_percentage_sensor - - high_zone_air_co2_concentration_alarm + - exhaust_fan_speed_percentage_sensor + - high_zone_air_co2_concentration_alarm uses: - - exhaust_fan_speed_percentage_command - - zone_air_co2_concentration_sensor - - zone_air_co2_concentration_setpoint + - exhaust_fan_speed_percentage_command + - zone_air_co2_concentration_sensor + - zone_air_co2_concentration_setpoint implements: - - CONTROL + - CONTROL RACO2C: guid: "38ba1a66-8aa5-4c79-b755-734804901626" description: "Returned air carbon dioxide levels controls." is_abstract: true uses: - - return_air_co2_concentration_sensor - - return_air_co2_concentration_setpoint + - return_air_co2_concentration_sensor + - return_air_co2_concentration_setpoint DX2DDC: guid: "fbee3bb9-dc8b-4a49-a3eb-97439d0851bc" description: "Two compressor run control with dual setpoint control on discharge side" is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - failed_discharge_air_temperature_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - failed_discharge_air_temperature_alarm uses: - - compressor_run_command_1 - - compressor_run_command_2 - - compressor_run_status_1 - - compressor_run_status_2 - - discharge_air_cooling_temperature_setpoint - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor + - compressor_run_command_1 + - compressor_run_command_2 + - compressor_run_status_1 + - compressor_run_status_2 + - discharge_air_cooling_temperature_setpoint + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor implements: - - CONTROL + - CONTROL HWDT: guid: "197d48e2-b069-492d-8ae4-4545b844e3a8" description: "Temperature differential across heating water for heat recovery chiller." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - heating_return_water_temperature_sensor - - heating_supply_water_temperature_sensor + - heating_return_water_temperature_sensor + - heating_supply_water_temperature_sensor HPDDC: guid: "002edb3a-e58d-4802-9c4b-6dc924d261dc" description: "Dual setpoint discharge side heat pump control." is_abstract: true opt_uses: - - compressor_speed_percentage_command - - cooling_percentage_command - - cooling_thermal_power_capacity - - heating_thermal_power_capacity - - compressor_lost_power_alarm - - failed_compressor_alarm - - failed_discharge_air_temperature_alarm - - overload_compressor_alarm + - compressor_speed_percentage_command + - cooling_percentage_command + - cooling_thermal_power_capacity + - heating_thermal_power_capacity + - compressor_lost_power_alarm + - failed_compressor_alarm + - failed_discharge_air_temperature_alarm + - overload_compressor_alarm uses: - - compressor_run_command - - compressor_run_status - - discharge_air_cooling_temperature_setpoint - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor - - reversing_valve_command + - compressor_run_command + - compressor_run_status + - discharge_air_cooling_temperature_setpoint + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor + - reversing_valve_command implements: - - CONTROL + - CONTROL EC2SC: guid: "6bf5cfa7-5659-4919-8c34-d60c8e931492" description: "Evaporative cooler control on supply side." is_abstract: true opt_uses: - - cooling_percentage_sensor - - cooling_request_count - - evaporative_cooler_run_status_1 - - evaporative_cooler_run_status_2 - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm + - cooling_percentage_sensor + - cooling_request_count + - evaporative_cooler_run_status_1 + - evaporative_cooler_run_status_2 + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm uses: - - evaporative_cooler_run_command_1 - - evaporative_cooler_run_command_2 - - supply_air_temperature_sensor - - supply_air_temperature_setpoint + - evaporative_cooler_run_command_1 + - evaporative_cooler_run_command_2 + - supply_air_temperature_sensor + - supply_air_temperature_setpoint implements: - - CONTROL + - CONTROL HWDDC: guid: "b257d777-1ff2-41d7-8230-58a18d568f40" description: "Heating water valve with dual setpoint control on discharge side." is_abstract: true opt_uses: - - discharge_air_relative_humidity_sensor - - heating_thermal_power_capacity - - heating_water_flowrate_sensor - - heating_water_valve_percentage_sensor - - failed_discharge_air_temperature_alarm + - discharge_air_relative_humidity_sensor + - heating_thermal_power_capacity + - heating_water_flowrate_sensor + - heating_water_valve_percentage_sensor + - failed_discharge_air_temperature_alarm uses: - - discharge_air_heating_temperature_setpoint - - discharge_air_temperature_sensor - - heating_water_valve_percentage_command + - discharge_air_heating_temperature_setpoint + - discharge_air_temperature_sensor + - heating_water_valve_percentage_command implements: - - CONTROL + - CONTROL CFDPM: guid: "be3e3bc0-e927-46a1-9b63-62717fa740ca" description: "Carbon filter pressure monitoring, where specific filter type is required." is_abstract: true uses: - - carbon_filter_differential_pressure_sensor + - carbon_filter_differential_pressure_sensor implements: - - MONITORING + - MONITORING VOADM2X: guid: "bce9e194-e5cc-459f-be23-d73af8394b25" description: "Variable outside air damper monitoring, where there are two separate, equal sets of dampers that operate in conjunction." is_abstract: true opt_uses: - - economizer_mode - - low_limit_outside_air_damper_percentage_command - - mixed_air_temperature_sensor - - outside_air_damper_percentage_sensor_1 - - outside_air_damper_percentage_sensor_2 - - outside_air_flowrate_sensor_1 - - outside_air_flowrate_sensor_2 - - failed_mixed_air_temperature_alarm + - economizer_mode + - low_limit_outside_air_damper_percentage_command + - mixed_air_temperature_sensor + - outside_air_damper_percentage_sensor_1 + - outside_air_damper_percentage_sensor_2 + - outside_air_flowrate_sensor_1 + - outside_air_flowrate_sensor_2 + - failed_mixed_air_temperature_alarm uses: - - outside_air_damper_percentage_command_1 - - outside_air_damper_percentage_command_2 - - outside_air_temperature_sensor + - outside_air_damper_percentage_command_1 + - outside_air_damper_percentage_command_2 + - outside_air_temperature_sensor implements: - - MONITORING + - MONITORING EHHRC: guid: "350243a7-bac9-45b8-b614-6ada6cf48ef6" description: "Exhaust hydronic heat recovery coil with an isolation valve." is_abstract: true uses: - - entering_heat_recovery_coil_temperature_sensor - - exhaust_air_flowrate_sensor - - heat_recovery_water_isolation_valve_command - - leaving_heat_recovery_coil_temperature_sensor + - entering_heat_recovery_coil_temperature_sensor + - exhaust_air_flowrate_sensor + - heat_recovery_water_isolation_valve_command + - leaving_heat_recovery_coil_temperature_sensor implements: - - MONITORING + - MONITORING DPBHCC: guid: "064adc2f-b5aa-4bc6-bd8e-4d72bed60070" @@ -5390,713 +5390,713 @@ DPBHCC: temperature (heating/cooling setpoint configuration)." is_abstract: true opt_uses: - - cooling_request_count - - heating_request_count - - zone_air_relative_humidity_sensor - - failed_zone_air_temperature_alarm - - high_zone_air_temperature_alarm - - low_zone_air_temperature_alarm + - cooling_request_count + - heating_request_count + - zone_air_relative_humidity_sensor + - failed_zone_air_temperature_alarm + - high_zone_air_temperature_alarm + - low_zone_air_temperature_alarm uses: - - chilled_supply_water_isolation_valve_command - - chilled_supply_water_isolation_valve_status - - heating_supply_water_isolation_valve_command - - heating_supply_water_isolation_valve_status - - zone_air_cooling_temperature_setpoint - - zone_air_heating_temperature_setpoint - - zone_air_temperature_sensor + - chilled_supply_water_isolation_valve_command + - chilled_supply_water_isolation_valve_status + - heating_supply_water_isolation_valve_command + - heating_supply_water_isolation_valve_status + - zone_air_cooling_temperature_setpoint + - zone_air_heating_temperature_setpoint + - zone_air_temperature_sensor implements: - - CONTROL + - CONTROL FTC: guid: "26877aed-9bea-44a8-afca-c7dea27d9b35" description: "Floor temperature control, where the temperature sensors are embedded in the floor (as opposed to open to the air)." is_abstract: true uses: - - zone_floor_temperature_sensor - - zone_floor_temperature_setpoint + - zone_floor_temperature_sensor + - zone_floor_temperature_setpoint implements: - - OPERATIONAL + - OPERATIONAL DPCHWHRWSC: guid: "e7feffef-9d26-4393-b02c-8b5a26be97d6" description: "Two-pipe chilled water and heat recovery water control using the same coils." is_abstract: true opt_uses: - - chilled_return_water_isolation_valve_status - - chilled_return_water_temperature_sensor - - chilled_supply_water_isolation_valve_status - - chilled_supply_water_temperature_sensor - - heat_recovery_return_water_isolation_valve_status - - heat_recovery_return_water_temperature_sensor - - heat_recovery_supply_water_isolation_valve_status - - heat_recovery_supply_water_temperature_sensor - - leaving_coil_temperature_sensor - - supply_water_valve_percentage_sensor - - high_supply_air_temperature_alarm - - low_supply_air_temperature_alarm - uses: - - chilled_supply_water_isolation_valve_command - - heat_recovery_run_command - - heat_recovery_supply_water_isolation_valve_command - - supply_air_temperature_sensor - - supply_air_temperature_setpoint - - supply_water_valve_percentage_command - implements: - - CONTROL + - chilled_return_water_isolation_valve_status + - chilled_return_water_temperature_sensor + - chilled_supply_water_isolation_valve_status + - chilled_supply_water_temperature_sensor + - heat_recovery_return_water_isolation_valve_status + - heat_recovery_return_water_temperature_sensor + - heat_recovery_supply_water_isolation_valve_status + - heat_recovery_supply_water_temperature_sensor + - leaving_coil_temperature_sensor + - supply_water_valve_percentage_sensor + - high_supply_air_temperature_alarm + - low_supply_air_temperature_alarm + uses: + - chilled_supply_water_isolation_valve_command + - heat_recovery_run_command + - heat_recovery_supply_water_isolation_valve_command + - supply_air_temperature_sensor + - supply_air_temperature_setpoint + - supply_water_valve_percentage_command + implements: + - CONTROL CPVSC2X: guid: "1be3e1ba-1a25-4b9a-9784-e4bbd9313db5" description: "Circulation pump variable speed control with 2 circulation pumps." is_abstract: true uses: - - circulation_pump_run_command_1 - - circulation_pump_run_command_2 - - circulation_pump_run_status_1 - - circulation_pump_run_status_2 - - circulation_pump_speed_percentage_command_1 - - circulation_pump_speed_percentage_command_2 + - circulation_pump_run_command_1 + - circulation_pump_run_command_2 + - circulation_pump_run_status_1 + - circulation_pump_run_status_2 + - circulation_pump_speed_percentage_command_1 + - circulation_pump_speed_percentage_command_2 implements: - - OPERATIONAL + - OPERATIONAL HWTTC: guid: "141c33da-9691-4e45-a572-3b06402a54d7" description: "Hot water tank temperature control." is_abstract: true opt_uses: - - high_water_temperature_alarm + - high_water_temperature_alarm uses: - - hot_water_tank_temperature_sensor - - hot_water_tank_temperature_setpoint + - hot_water_tank_temperature_sensor + - hot_water_tank_temperature_setpoint implements: - - OPERATIONAL + - OPERATIONAL PHWTTC: guid: "8da5a38c-e6de-43c1-9888-689c7cd35ff2" description: "Preheating water tank temperature control." is_abstract: true uses: - - preheating_water_tank_temperature_sensor - - preheating_water_tank_temperature_setpoint + - preheating_water_tank_temperature_sensor + - preheating_water_tank_temperature_setpoint implements: - - OPERATIONAL + - OPERATIONAL RCKTM: guid: "8ea49daa-0f94-46fe-a919-8614752b1f9f" description: "Refrigeration circuit monitoring for a DX compressor loop." is_abstract: true uses: - - refrigerant_discharge_pressure_sensor - - refrigerant_discharge_temperature_sensor - - refrigerant_liquid_pressure_sensor - - refrigerant_liquid_saturation_temperature_sensor - - refrigerant_liquid_temperature_sensor - - refrigerant_subcooling_temperature_sensor - - refrigerant_suction_pressure_sensor - - refrigerant_suction_saturation_temperature_sensor - - refrigerant_suction_superheat_temperature_sensor - - refrigerant_suction_temperature_sensor + - refrigerant_discharge_pressure_sensor + - refrigerant_discharge_temperature_sensor + - refrigerant_liquid_pressure_sensor + - refrigerant_liquid_saturation_temperature_sensor + - refrigerant_liquid_temperature_sensor + - refrigerant_subcooling_temperature_sensor + - refrigerant_suction_pressure_sensor + - refrigerant_suction_saturation_temperature_sensor + - refrigerant_suction_superheat_temperature_sensor + - refrigerant_suction_temperature_sensor RCKTM2X: guid: "c8303789-9f0f-4a0f-9f27-474771b554a3" description: "Refrigeration circuits (2x) monitoring for a DX compressor loop." is_abstract: true uses: - - refrigerant_discharge_pressure_sensor_1 - - refrigerant_discharge_pressure_sensor_2 - - refrigerant_discharge_temperature_sensor_1 - - refrigerant_discharge_temperature_sensor_2 - - refrigerant_liquid_pressure_sensor_1 - - refrigerant_liquid_pressure_sensor_2 - - refrigerant_liquid_saturation_temperature_sensor_1 - - refrigerant_liquid_saturation_temperature_sensor_2 - - refrigerant_liquid_temperature_sensor_1 - - refrigerant_liquid_temperature_sensor_2 - - refrigerant_subcooling_temperature_sensor_1 - - refrigerant_subcooling_temperature_sensor_2 - - refrigerant_suction_pressure_sensor_1 - - refrigerant_suction_pressure_sensor_2 - - refrigerant_suction_saturation_temperature_sensor_1 - - refrigerant_suction_saturation_temperature_sensor_2 - - refrigerant_suction_superheat_temperature_sensor_1 - - refrigerant_suction_superheat_temperature_sensor_2 - - refrigerant_suction_temperature_sensor_1 - - refrigerant_suction_temperature_sensor_2 + - refrigerant_discharge_pressure_sensor_1 + - refrigerant_discharge_pressure_sensor_2 + - refrigerant_discharge_temperature_sensor_1 + - refrigerant_discharge_temperature_sensor_2 + - refrigerant_liquid_pressure_sensor_1 + - refrigerant_liquid_pressure_sensor_2 + - refrigerant_liquid_saturation_temperature_sensor_1 + - refrigerant_liquid_saturation_temperature_sensor_2 + - refrigerant_liquid_temperature_sensor_1 + - refrigerant_liquid_temperature_sensor_2 + - refrigerant_subcooling_temperature_sensor_1 + - refrigerant_subcooling_temperature_sensor_2 + - refrigerant_suction_pressure_sensor_1 + - refrigerant_suction_pressure_sensor_2 + - refrigerant_suction_saturation_temperature_sensor_1 + - refrigerant_suction_saturation_temperature_sensor_2 + - refrigerant_suction_superheat_temperature_sensor_1 + - refrigerant_suction_superheat_temperature_sensor_2 + - refrigerant_suction_temperature_sensor_1 + - refrigerant_suction_temperature_sensor_2 CCM: guid: "4690242f-f5fe-47cb-9340-771cfc6cecb3" description: "Compressor current monitoring." is_abstract: true uses: - - compressor_current_sensor - - compressor_run_command + - compressor_current_sensor + - compressor_run_command CC2XM: guid: "6eabfba1-1cc6-43d7-a46a-baaaeb0782d5" description: "Compressor current monitoring for 2 compressors." is_abstract: true uses: - - compressor_current_sensor_1 - - compressor_current_sensor_2 - - compressor_run_command_1 - - compressor_run_command_2 + - compressor_current_sensor_1 + - compressor_current_sensor_2 + - compressor_run_command_1 + - compressor_run_command_2 CFCM: guid: "6e4901e4-67f5-44d9-8239-84a1a2379419" description: "Condenser fan current monitoring for a single fan." is_abstract: true uses: - - condensing_fan_current_sensor + - condensing_fan_current_sensor CFCM4X: guid: "3b5df213-0616-400f-a025-69e72cda4d7b" description: "Condenser fan current monitoring for 4 fans." is_abstract: true uses: - - condensing_fan_current_sensor_1 - - condensing_fan_current_sensor_2 - - condensing_fan_current_sensor_3 - - condensing_fan_current_sensor_4 + - condensing_fan_current_sensor_1 + - condensing_fan_current_sensor_2 + - condensing_fan_current_sensor_3 + - condensing_fan_current_sensor_4 CFCM6X: guid: "47dcd13d-d95c-44bf-988b-ce8ec32cebe2" description: "Condenser fan current monitoring for 6 fans." is_abstract: true uses: - - condensing_fan_current_sensor_1 - - condensing_fan_current_sensor_2 - - condensing_fan_current_sensor_3 - - condensing_fan_current_sensor_4 - - condensing_fan_current_sensor_5 - - condensing_fan_current_sensor_6 + - condensing_fan_current_sensor_1 + - condensing_fan_current_sensor_2 + - condensing_fan_current_sensor_3 + - condensing_fan_current_sensor_4 + - condensing_fan_current_sensor_5 + - condensing_fan_current_sensor_6 SSSPC: guid: "f933f42e-faf1-4039-801a-83f3eff24461" description: "Supply static steam pressure control for steam/water heat exchanger" is_abstract: true uses: - - steam_valve_percentage_command - - supply_steam_static_pressure_sensor - - supply_steam_static_pressure_setpoint + - steam_valve_percentage_command + - supply_steam_static_pressure_sensor + - supply_steam_static_pressure_setpoint implements: - - CONTROL + - CONTROL SCHWISOVPM: guid: "39e76027-e924-48af-a507-dd33948e455b" description: "Secondary chilled water return side isolation valve percentage monitoring." is_abstract: true uses: - - secondary_chilled_return_water_isolation_valve_percentage_command - - secondary_chilled_return_water_isolation_valve_percentage_sensor + - secondary_chilled_return_water_isolation_valve_percentage_command + - secondary_chilled_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING SCHWDT: guid: "bafc8c7a-fd40-4cd6-8b95-e3beb268eac9" description: "Secondary-side chilled water delta-T monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - secondary_chilled_return_water_temperature_sensor - - secondary_chilled_supply_water_temperature_sensor + - secondary_chilled_return_water_temperature_sensor + - secondary_chilled_supply_water_temperature_sensor SHWDT: guid: "6dd5a198-e339-406e-9f43-f2682218bd9c" description: "Secondary-side heating water delta-T monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - secondary_heating_return_water_temperature_sensor - - secondary_heating_supply_water_temperature_sensor + - secondary_heating_return_water_temperature_sensor + - secondary_heating_supply_water_temperature_sensor PCHWDT: guid: "cfb74347-2e51-4034-8e5d-0015bdbe59a5" description: "Temperature differential across primary chilled water loop." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - primary_chilled_return_water_temperature_sensor - - primary_chilled_supply_water_temperature_sensor + - primary_chilled_return_water_temperature_sensor + - primary_chilled_supply_water_temperature_sensor PHWDT: guid: "06e84e2c-8935-4c9a-80cb-f08890005f4a" description: "Temperature differential across primary heating water loop." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - primary_heating_return_water_temperature_sensor - - primary_heating_supply_water_temperature_sensor + - primary_heating_return_water_temperature_sensor + - primary_heating_supply_water_temperature_sensor TDTM: guid: "5c4a89f4-a163-4b73-9064-aa3dfd8361e7" description: "water tank delta-T monitoring." is_abstract: true uses: - - entering_water_tank_temperature_sensor - - leaving_water_tank_temperature_sensor + - entering_water_tank_temperature_sensor + - leaving_water_tank_temperature_sensor implements: - - MONITORING + - MONITORING HLPM: guid: "ae617b98-6deb-4c17-8d63-4504feea2988" description: "Heating thermal power sensor." is_abstract: true uses: - - heating_thermal_power_sensor + - heating_thermal_power_sensor implements: - - MONITORING + - MONITORING CWRWISOVM: guid: "857f28d7-c853-41bb-929c-23b942bcb5b8" description: "Condensing water supply side isolation valve monitoring." is_abstract: true uses: - - condensing_return_water_isolation_valve_command - - condensing_return_water_isolation_valve_status + - condensing_return_water_isolation_valve_command + - condensing_return_water_isolation_valve_status implements: - - MONITORING + - MONITORING CWRWISOVPM: guid: "f9c6f9f6-aad8-4ea8-ab7d-fbd343a53830" description: "Condensing water return side isolation valve percentage monitoring." is_abstract: true uses: - - condensing_return_water_isolation_valve_percentage_command - - condensing_return_water_isolation_valve_percentage_sensor + - condensing_return_water_isolation_valve_percentage_command + - condensing_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING OCWRWISOVM: guid: "daec7559-f465-4117-9606-92353b8a1ae1" description: "Open-loop CDW return side isolation valve monitoring." is_abstract: true uses: - - outside_condensing_loop_return_water_isolation_valve_command - - outside_condensing_loop_return_water_isolation_valve_status + - outside_condensing_loop_return_water_isolation_valve_command + - outside_condensing_loop_return_water_isolation_valve_status implements: - - MONITORING + - MONITORING OCWRWISOVPM: guid: "16a303e1-ab6a-49d1-8c3b-6e02c6a78cca" description: "Open-loop CDW return side isolation valve monitoring." is_abstract: true uses: - - outside_condensing_loop_return_water_isolation_valve_percentage_command - - outside_condensing_loop_return_water_isolation_valve_percentage_sensor + - outside_condensing_loop_return_water_isolation_valve_percentage_command + - outside_condensing_loop_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING HWRWISOVM: guid: "a2ca0c24-c44d-44ea-95cb-728da67d7c78" description: "Heating return side isolation valve monitoring." is_abstract: true uses: - - heating_return_water_isolation_valve_command - - heating_return_water_isolation_valve_status + - heating_return_water_isolation_valve_command + - heating_return_water_isolation_valve_status implements: - - MONITORING + - MONITORING HWSWISOVM: guid: "1f0a45f0-b5fd-47b3-a870-bd11dccb7239" description: "Heating supply side isolation valve monitoring." is_abstract: true uses: - - heating_supply_water_isolation_valve_command - - heating_supply_water_isolation_valve_status + - heating_supply_water_isolation_valve_command + - heating_supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING HWRWISOVPM: guid: "b02b1e0e-ca30-4fb0-8700-84225bf8d635" description: "Heating return side isolation valve percentage monitoring." is_abstract: true uses: - - heating_return_water_isolation_valve_percentage_command - - heating_return_water_isolation_valve_percentage_sensor + - heating_return_water_isolation_valve_percentage_command + - heating_return_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING DEFSS: guid: "7102dc2c-4f27-4bbb-a9a4-965e71f3ac79" description: "defrost run command and status (start/stop) " is_abstract: true uses: - - defrost_run_command - - defrost_run_status + - defrost_run_command + - defrost_run_status implements: - - MONITORING + - MONITORING opt_uses: - - frost_alarm + - frost_alarm DEFSTC: guid: "c52e2a01-3e72-449c-9215-93d4af12ffc6" description: "Defrost temperature control." is_abstract: true uses: - - defrost_temperature_sensor - - defrost_temperature_setpoint + - defrost_temperature_sensor + - defrost_temperature_setpoint opt_uses: - - frost_alarm + - frost_alarm VOADC2X: guid: "c3072c9a-71f4-41e8-a728-c2730f327fc6" description: "Variable outside air damper control and monitoring, where there are two separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - outside_air_damper_percentage_command_1 - - outside_air_damper_percentage_command_2 - - outside_air_damper_percentage_sensor_1 - - outside_air_damper_percentage_sensor_2 + - outside_air_damper_percentage_command_1 + - outside_air_damper_percentage_command_2 + - outside_air_damper_percentage_sensor_1 + - outside_air_damper_percentage_sensor_2 implements: - - OPERATIONAL + - OPERATIONAL RAIDC: guid: "07b8b6ca-5fb7-471d-a50e-2ad266eb4a31" description: "Return air isolation damper control and monitoring." is_abstract: true uses: - - return_air_isolation_damper_command - - return_air_isolation_damper_status + - return_air_isolation_damper_command + - return_air_isolation_damper_status opt_uses: - - failed_return_air_isolation_damper_alarm + - failed_return_air_isolation_damper_alarm RAIDC3X: guid: "8d678b8d-244a-41b3-9e2b-e72fd5dd1778" description: "Return air isolation damper control and monitoring, where there are three separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - return_air_isolation_damper_command_1 - - return_air_isolation_damper_command_2 - - return_air_isolation_damper_command_3 - - return_air_isolation_damper_status_1 - - return_air_isolation_damper_status_2 - - return_air_isolation_damper_status_3 + - return_air_isolation_damper_command_1 + - return_air_isolation_damper_command_2 + - return_air_isolation_damper_command_3 + - return_air_isolation_damper_status_1 + - return_air_isolation_damper_status_2 + - return_air_isolation_damper_status_3 implements: - - MONITORING + - MONITORING RAIDC2X: guid: "a75ae9d1-c1bd-4fb5-9908-cc59f6b2f321" description: "Return air isolation damper control and monitoring, where there are two separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - return_air_isolation_damper_command_1 - - return_air_isolation_damper_command_2 - - return_air_isolation_damper_status_1 - - return_air_isolation_damper_status_2 + - return_air_isolation_damper_command_1 + - return_air_isolation_damper_command_2 + - return_air_isolation_damper_status_1 + - return_air_isolation_damper_status_2 implements: - - MONITORING + - MONITORING DAIDC2X: guid: "a31bfc83-51f3-4c0f-8f60-eb21bf9e5688" description: "Discharge air isolation damper control and monitoring, where there are two separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - discharge_air_isolation_damper_command_1 - - discharge_air_isolation_damper_command_2 - - discharge_air_isolation_damper_status_1 - - discharge_air_isolation_damper_status_2 + - discharge_air_isolation_damper_command_1 + - discharge_air_isolation_damper_command_2 + - discharge_air_isolation_damper_status_1 + - discharge_air_isolation_damper_status_2 implements: - - MONITORING + - MONITORING DAIDC: guid: "35f6ae55-3f74-4fcc-bfb2-3412670f8d60" description: "Discharge air isolation damper control and monitoring." is_abstract: true uses: - - discharge_air_isolation_damper_command - - discharge_air_isolation_damper_status + - discharge_air_isolation_damper_command + - discharge_air_isolation_damper_status implements: - - MONITORING + - MONITORING opt_uses: - - failed_discharge_air_isolation_damper_alarm + - failed_discharge_air_isolation_damper_alarm RAIDC4X: guid: "2a234621-dfb8-4aab-a825-49e3bfc107b6" description: "Return air isolation damper control and monitoring, where there are four separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - return_air_isolation_damper_command_1 - - return_air_isolation_damper_command_2 - - return_air_isolation_damper_command_3 - - return_air_isolation_damper_command_4 - - return_air_isolation_damper_status_1 - - return_air_isolation_damper_status_2 - - return_air_isolation_damper_status_3 - - return_air_isolation_damper_status_4 + - return_air_isolation_damper_command_1 + - return_air_isolation_damper_command_2 + - return_air_isolation_damper_command_3 + - return_air_isolation_damper_command_4 + - return_air_isolation_damper_status_1 + - return_air_isolation_damper_status_2 + - return_air_isolation_damper_status_3 + - return_air_isolation_damper_status_4 implements: - - MONITORING + - MONITORING SAIDC: guid: "9c0ec280-99e6-4f44-9b67-7ea5f4bdfeba" description: "isolation damper status monitoring and control on the supply side." is_abstract: true uses: - - supply_air_isolation_damper_command - - supply_air_isolation_damper_status + - supply_air_isolation_damper_command + - supply_air_isolation_damper_status implements: - - MONITORING + - MONITORING opt_uses: - - failed_supply_air_isolation_damper_alarm + - failed_supply_air_isolation_damper_alarm SAIDC2X: guid: "2fd14ae4-e0c5-4057-a998-9fe72d27a494" description: "isolation damper status monitoring and control on the supply side, where there are two separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - supply_air_isolation_damper_command_1 - - supply_air_isolation_damper_command_2 - - supply_air_isolation_damper_status_1 - - supply_air_isolation_damper_status_2 + - supply_air_isolation_damper_command_1 + - supply_air_isolation_damper_command_2 + - supply_air_isolation_damper_status_1 + - supply_air_isolation_damper_status_2 implements: - - MONITORING + - MONITORING SAIDC3X: guid: "2ad5c08c-1d77-4df3-af6b-92aecc5b8eaa" description: "isolation damper status monitoring and control on the supply side, where there are three separate, equal sets of dampers that operate in conjunction." is_abstract: true uses: - - supply_air_isolation_damper_command_1 - - supply_air_isolation_damper_command_2 - - supply_air_isolation_damper_command_3 - - supply_air_isolation_damper_status_1 - - supply_air_isolation_damper_status_2 - - supply_air_isolation_damper_status_3 + - supply_air_isolation_damper_command_1 + - supply_air_isolation_damper_command_2 + - supply_air_isolation_damper_command_3 + - supply_air_isolation_damper_status_1 + - supply_air_isolation_damper_status_2 + - supply_air_isolation_damper_status_3 implements: - - MONITORING + - MONITORING SSPC2X: guid: "52328bf9-1e7e-42b3-a66d-fbdeabf1105f" description: "Supply static pressure control via supply fan speed with 2 sensors" is_abstract: true opt_uses: - - average_supply_air_static_pressure_sensor - - pressurization_request_count - - supply_air_damper_percentage_command - - supply_air_flowrate_sensor - - supply_fan_run_command - - supply_fan_run_status - - supply_fan_speed_frequency_sensor - - supply_fan_speed_percentage_command - - failed_supply_fan_alarm + - average_supply_air_static_pressure_sensor + - pressurization_request_count + - supply_air_damper_percentage_command + - supply_air_flowrate_sensor + - supply_fan_run_command + - supply_fan_run_status + - supply_fan_speed_frequency_sensor + - supply_fan_speed_percentage_command + - failed_supply_fan_alarm uses: - - supply_air_static_pressure_sensor_1 - - supply_air_static_pressure_sensor_2 - - supply_air_static_pressure_setpoint_1 - - supply_air_static_pressure_setpoint_2 + - supply_air_static_pressure_sensor_1 + - supply_air_static_pressure_sensor_2 + - supply_air_static_pressure_setpoint_1 + - supply_air_static_pressure_setpoint_2 implements: - - OPERATIONAL + - OPERATIONAL SFMSC: guid: "b95a77b1-35fd-4447-8a8a-f156f6b363b6" description: "Supply fan multi-speed control." is_abstract: true uses: - - supply_fan_run_command - - supply_fan_run_mode - - supply_fan_run_status - - supply_fan_speed_mode + - supply_fan_run_command + - supply_fan_run_mode + - supply_fan_run_status + - supply_fan_speed_mode opt_uses: - - schedule_run_command - - failed_supply_fan_alarm + - schedule_run_command + - failed_supply_fan_alarm MIPVCM: guid: "59c2ed91-daa7-4f30-916d-78ac67105014" description: "Motor phase-level input current and voltage monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - input_phase1_line_motor_current_sensor - - input_phase1_phase2_line_motor_voltage_sensor - - input_phase1_phase3_line_motor_voltage_sensor - - input_phase2_line_motor_current_sensor - - input_phase2_phase3_line_motor_voltage_sensor - - input_phase3_line_motor_current_sensor + - input_phase1_line_motor_current_sensor + - input_phase1_phase2_line_motor_voltage_sensor + - input_phase1_phase3_line_motor_voltage_sensor + - input_phase2_line_motor_current_sensor + - input_phase2_phase3_line_motor_voltage_sensor + - input_phase3_line_motor_current_sensor opt_uses: - - average_input_inter_line_motor_voltage_sensor - - average_input_line_motor_current_sensor + - average_input_inter_line_motor_voltage_sensor + - average_input_line_motor_current_sensor MIPWM: guid: "c859ef99-c44d-4f64-9fa7-461af73ede05" description: "Motor input power monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - input_motor_power_sensor + - input_motor_power_sensor opt_uses: - - input_motor_frequency_sensor - - motor_powerfactor_sensor + - input_motor_frequency_sensor + - motor_powerfactor_sensor MSM: guid: "6994d3a0-7a74-44df-b5d6-88ea384fa22a" description: "Motor speed monitoring for fan." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - discharge_fan_run_status - - high_discharge_fan_speed_status - - low_discharge_fan_speed_status + - discharge_fan_run_status + - high_discharge_fan_speed_status + - low_discharge_fan_speed_status opt_uses: - - failed_discharge_fan_alarm + - failed_discharge_fan_alarm INVOPWM: guid: "3fe50f00-5db3-4fea-9838-111e78ce489f" description: "Inverter (VFD) output power monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - output_inverter_power_sensor + - output_inverter_power_sensor opt_uses: - - input_inverter_frequency_sensor - - output_inverter_voltage_sensor + - input_inverter_frequency_sensor + - output_inverter_voltage_sensor INVIPCM: guid: "d830e49e-08d3-4ae6-a741-7ac12f5215e8" description: "Inverter (VFD) 3-phase input current monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - input_phase1_line_inverter_current_sensor - - input_phase2_line_inverter_current_sensor - - input_phase3_line_inverter_current_sensor + - input_phase1_line_inverter_current_sensor + - input_phase2_line_inverter_current_sensor + - input_phase3_line_inverter_current_sensor CWSWISOVPM: guid: "70698046-b9b1-462c-bb75-3c06d9b7628c" description: "Condensing water supply side isolation valve percentage monitoring." is_abstract: true uses: - - condensing_supply_water_isolation_valve_percentage_command - - condensing_supply_water_isolation_valve_percentage_sensor + - condensing_supply_water_isolation_valve_percentage_command + - condensing_supply_water_isolation_valve_percentage_sensor implements: - - MONITORING + - MONITORING GTWFCISOVM: guid: "649fa2ba-7374-49a7-8989-6b6ac728178e" description: "Geothermal water free-cooling isolation valve monitoring; exclusively using ground as heat sink for building load." is_abstract: true uses: - - chilled_side_ground_return_economizer_isolation_valve_command - - chilled_side_ground_return_economizer_isolation_valve_status - - chilled_side_ground_supply_economizer_isolation_valve_status + - chilled_side_ground_return_economizer_isolation_valve_command + - chilled_side_ground_return_economizer_isolation_valve_status + - chilled_side_ground_supply_economizer_isolation_valve_status implements: - - MONITORING + - MONITORING GTWGRISOVM: guid: "a323f1e9-8722-4126-a5be-d8e9c2e27f7d" description: "Geothermal water ground-recharge isolation valve monitoring; rejecting ground heat to atmosphere via cooling towers." is_abstract: true uses: - - heating_side_ground_return_economizer_isolation_valve_command - - heating_side_ground_return_economizer_isolation_valve_status - - heating_side_ground_supply_economizer_isolation_valve_status + - heating_side_ground_return_economizer_isolation_valve_command + - heating_side_ground_return_economizer_isolation_valve_status + - heating_side_ground_supply_economizer_isolation_valve_status implements: - - MONITORING + - MONITORING GTWHEISOVM: guid: "0568720c-dc0f-404a-8139-af79401d0c43" description: "Geothermal water heat-extraction isolation valve monitoring; extracting ground heat to to use in building." is_abstract: true uses: - - chilled_side_ground_return_water_isolation_valve_status - - chilled_side_ground_supply_water_isolation_valve_command - - chilled_side_ground_supply_water_isolation_valve_status + - chilled_side_ground_return_water_isolation_valve_status + - chilled_side_ground_supply_water_isolation_valve_command + - chilled_side_ground_supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING GTWHRISOVM: guid: "c17a6215-3493-4693-bef1-52e8d079742f" description: "Geothermal water heat-rejection isolation valve monitoring; rejecting building heat to ground." is_abstract: true uses: - - heating_side_ground_return_water_isolation_valve_status - - heating_side_ground_supply_water_isolation_valve_command - - heating_side_ground_supply_water_isolation_valve_status + - heating_side_ground_return_water_isolation_valve_status + - heating_side_ground_supply_water_isolation_valve_command + - heating_side_ground_supply_water_isolation_valve_status implements: - - MONITORING + - MONITORING COCDSP: guid: "c4c91584-0506-4ba5-95ad-f49d57eb3c67" description: "Dual setpoint CO concentration control." is_abstract: true uses: - - high_limit_zone_air_co_concentration_setpoint - - low_limit_zone_air_co_concentration_setpoint - - zone_air_co_concentration_sensor + - high_limit_zone_air_co_concentration_setpoint + - low_limit_zone_air_co_concentration_setpoint + - zone_air_co_concentration_sensor implements: - - CONTROL + - CONTROL opt_uses: - - high_zone_air_co_concentration_alarm + - high_zone_air_co_concentration_alarm NOCDSP: guid: "df6c124a-fdd8-4422-b33d-56f46d66dbc8" description: "Dual setpoint NO concentration control." is_abstract: true uses: - - high_limit_zone_air_no_concentration_setpoint - - low_limit_zone_air_no_concentration_setpoint - - zone_air_no_concentration_sensor + - high_limit_zone_air_no_concentration_setpoint + - low_limit_zone_air_no_concentration_setpoint + - zone_air_no_concentration_sensor implements: - - CONTROL + - CONTROL EFHLC: guid: "6951a8f3-40e6-461a-a225-70041409441f" description: "Two-speed exhaust fan (low/high)." is_abstract: true uses: - - high_exhaust_fan_speed_command - - high_exhaust_fan_speed_status - - low_exhaust_fan_speed_command - - low_exhaust_fan_speed_status + - high_exhaust_fan_speed_command + - high_exhaust_fan_speed_status + - low_exhaust_fan_speed_command + - low_exhaust_fan_speed_status implements: - - OPERATIONAL + - OPERATIONAL HLC: guid: "c225f8c3-1bd8-4f59-aabe-012c1eb992b5" description: "Two-speed motor (high/low)." is_abstract: true opt_uses: - - high_speed_status - - low_speed_status + - high_speed_status + - low_speed_status uses: - - high_speed_command - - low_speed_command + - high_speed_command + - low_speed_command implements: - - OPERATIONAL + - OPERATIONAL SWCM: guid: "b82c4b84-96ae-48ee-a36b-29f274f6a41a" description: "Solenoid water valve control and monitoring." is_abstract: true uses: - - valve_command - - valve_status + - valve_command + - valve_status SCRSS: guid: "636b1262-b08b-4e1b-b130-e1a510b79a0c" description: "Scurbber start stop monitoring." is_abstract: true opt_uses: - - bypass_air_damper_percentage_command - - bypass_air_damper_percentage_sensor - - differential_pressure_sensor - - differential_pressure_setpoint - - scrubber_run_mode - - filter_alarm - - fire_alarm - - high_differential_pressure_alarm - - low_differential_pressure_alarm + - bypass_air_damper_percentage_command + - bypass_air_damper_percentage_sensor + - differential_pressure_sensor + - differential_pressure_setpoint + - scrubber_run_mode + - filter_alarm + - fire_alarm + - high_differential_pressure_alarm + - low_differential_pressure_alarm uses: - - scrubber_run_command - - scrubber_run_status + - scrubber_run_command + - scrubber_run_status implements: - - OPERATIONAL + - OPERATIONAL ##Abstracts for sensors PCM: @@ -6104,227 +6104,227 @@ PCM: description: "General particulate matter monitoring." is_abstract: true uses: - - particle_concentration_sensor + - particle_concentration_sensor implements: - - MONITORING + - MONITORING PMM: guid: "9c7fa9be-b9ec-46e1-8986-8e70b4ab04e3" description: "Zone air particulate matter monitoring." is_abstract: true uses: - - zone_air_pm10pt0_concentration_sensor - - zone_air_pm2pt5_concentration_sensor + - zone_air_pm10pt0_concentration_sensor + - zone_air_pm2pt5_concentration_sensor implements: - - MONITORING + - MONITORING PHWTC: guid: "f2d309b1-dc35-4aa3-8cf8-dc986cc05a79" description: "potable water temperature monitoring and control." is_abstract: true uses: - - potable_hot_water_temperature_sensor + - potable_hot_water_temperature_sensor LM: guid: "debce299-ec12-4d13-86fd-93e0cf10102e" description: "level monitoring of devices storing media." is_abstract: true uses: - - level_status - - percentage_sensor + - level_status + - percentage_sensor PLPM: guid: "87da5960-a441-49a1-8f80-05acdbf32426" description: "Pipeline Fluid pressure monitoring" is_abstract: true uses: - - line_pressure_sensor + - line_pressure_sensor CO2M4X: guid: "860e4db3-a171-4575-ad91-0002b01ea783" description: "Basic carbon dioxide monitoring for 4 Zones." is_abstract: true uses: - - zone_air_co2_concentration_sensor_1 - - zone_air_co2_concentration_sensor_2 - - zone_air_co2_concentration_sensor_3 - - zone_air_co2_concentration_sensor_4 + - zone_air_co2_concentration_sensor_1 + - zone_air_co2_concentration_sensor_2 + - zone_air_co2_concentration_sensor_3 + - zone_air_co2_concentration_sensor_4 implements: - - MONITORING + - MONITORING CO2M6X: guid: "3bea6d49-a70b-42c4-bd0c-592991dbf0f5" description: "Basic carbon dioxide monitoring for 6 Zones." is_abstract: true opt_uses: - - average_zone_air_co2_concentration_sensor - - max_zone_air_co2_concentration_sensor + - average_zone_air_co2_concentration_sensor + - max_zone_air_co2_concentration_sensor uses: - - zone_air_co2_concentration_sensor_1 - - zone_air_co2_concentration_sensor_2 - - zone_air_co2_concentration_sensor_3 - - zone_air_co2_concentration_sensor_4 - - zone_air_co2_concentration_sensor_5 - - zone_air_co2_concentration_sensor_6 + - zone_air_co2_concentration_sensor_1 + - zone_air_co2_concentration_sensor_2 + - zone_air_co2_concentration_sensor_3 + - zone_air_co2_concentration_sensor_4 + - zone_air_co2_concentration_sensor_5 + - zone_air_co2_concentration_sensor_6 implements: - - MONITORING + - MONITORING MIPCVM: guid: "17630266-40d3-4bc5-a9cd-9d70f10ef839" description: "Motor phase-level input current and voltage monitoring." is_abstract: true implements: - - MONITORING + - MONITORING uses: - - average_input_inter_line_motor_voltage_sensor - - average_input_line_motor_current_sensor - - input_motor_power_sensor + - average_input_inter_line_motor_voltage_sensor + - average_input_line_motor_current_sensor + - input_motor_power_sensor EPM: guid: "5976839e-9e26-48ef-8d7f-24106a6b7f97" description: "Basic Electrical parameter monitoring." is_abstract: true opt_uses: - - power_status + - power_status uses: - - current_sensor - - energy_accumulator - - power_sensor - - voltage_sensor + - current_sensor + - energy_accumulator + - power_sensor + - voltage_sensor implements: - - MONITORING + - MONITORING DFRMM: guid: "055a7881-d815-4bcd-aba5-2fac9a0d8e42" description: "Discharge fan run mode monitoring." is_abstract: true uses: - - discharge_fan_run_mode + - discharge_fan_run_mode implements: - - MONITORING + - MONITORING RDC: guid: "ca7914b6-f639-4d67-a6fc-22f5a4e613ff" description: "Return air damper percentage monitoring" is_abstract: true uses: - - return_air_damper_percentage_command - - return_air_damper_percentage_sensor + - return_air_damper_percentage_command + - return_air_damper_percentage_sensor implements: - - MONITORING + - MONITORING RFSS: guid: "2ca79174-7d36-4341-a820-0db83cd9470c" description: "Basic combination of return fan run command and status (start/stop)." is_abstract: true opt_uses: - - return_fan_current_sensor - - return_fan_power_sensor + - return_fan_current_sensor + - return_fan_power_sensor uses: - - return_fan_run_command - - return_fan_run_status + - return_fan_run_command + - return_fan_run_status implements: - - OPERATIONAL + - OPERATIONAL RFSS2X: guid: "8a0e3c63-308e-49d1-bab5-2780998cc6ac" description: "Return fan start-stop and feedback with two fan." is_abstract: true opt_uses: - - return_fan_current_sensor_1 - - return_fan_current_sensor_2 - - return_fan_power_sensor_1 - - return_fan_power_sensor_2 + - return_fan_current_sensor_1 + - return_fan_current_sensor_2 + - return_fan_power_sensor_1 + - return_fan_power_sensor_2 uses: - - return_fan_run_command_1 - - return_fan_run_command_2 - - return_fan_run_status_1 - - return_fan_run_status_2 + - return_fan_run_command_1 + - return_fan_run_command_2 + - return_fan_run_status_1 + - return_fan_run_status_2 implements: - - OPERATIONAL + - OPERATIONAL RFVSC: guid: "e36cc2ed-5694-4171-94b0-d32a94bb271c" description: "Variable speed control for a return fan." is_abstract: true opt_uses: - - return_fan_current_sensor - - return_fan_power_sensor - - return_fan_speed_frequency_sensor - - return_fan_speed_percentage_sensor + - return_fan_current_sensor + - return_fan_power_sensor + - return_fan_speed_frequency_sensor + - return_fan_speed_percentage_sensor uses: - - return_fan_run_command - - return_fan_run_status - - return_fan_speed_percentage_command + - return_fan_run_command + - return_fan_run_status + - return_fan_speed_percentage_command implements: - - OPERATIONAL + - OPERATIONAL RFVSC2X: guid: "3326bd01-506e-4dba-a410-9a34252b2d59" description: "Return fan variable speed control with feedback and sensoring for two fans." is_abstract: true opt_uses: - - return_fan_current_sensor_1 - - return_fan_current_sensor_2 - - return_fan_power_sensor_1 - - return_fan_power_sensor_2 - - return_fan_speed_frequency_sensor_1 - - return_fan_speed_frequency_sensor_2 - - return_fan_speed_percentage_sensor_1 - - return_fan_speed_percentage_sensor_2 + - return_fan_current_sensor_1 + - return_fan_current_sensor_2 + - return_fan_power_sensor_1 + - return_fan_power_sensor_2 + - return_fan_speed_frequency_sensor_1 + - return_fan_speed_frequency_sensor_2 + - return_fan_speed_percentage_sensor_1 + - return_fan_speed_percentage_sensor_2 uses: - - return_fan_run_command_1 - - return_fan_run_command_2 - - return_fan_run_status_1 - - return_fan_run_status_2 - - return_fan_speed_percentage_command_1 - - return_fan_speed_percentage_command_2 + - return_fan_run_command_1 + - return_fan_run_command_2 + - return_fan_run_status_1 + - return_fan_run_status_2 + - return_fan_speed_percentage_command_1 + - return_fan_speed_percentage_command_2 implements: - - OPERATIONAL + - OPERATIONAL SEWTM: guid: "bca463b0-2ecb-41df-8ad9-aab7690751d7" description: "Secondary water temperature monitoring" opt_uses: - - secondary_supply_water_temperature_sensor + - secondary_supply_water_temperature_sensor uses: - - secondary_return_water_temperature_sensor + - secondary_return_water_temperature_sensor implements: - - MONITORING + - MONITORING EXTOR: guid: "6f650a5a-06d3-4316-af26-7d4b8241aecf" description: "shade control with extension monitoring based on outside illuminance" is_abstract: true uses: - - shade_extent_percentage_command - - outside_illuminance_sensor - - low_limit_illuminance_setpoint - - high_limit_illuminance_setpoint + - shade_extent_percentage_command + - outside_illuminance_sensor + - low_limit_illuminance_setpoint + - high_limit_illuminance_setpoint DPHC2: guid: "6393d7b6-c538-4f2c-a43e-224f6f36ca6c" description: "Two-pipe heating and cooling control for radiant panels" is_abstract: true opt_uses: - - supply_water_temperature_sensor - - return_water_temperature_sensor + - supply_water_temperature_sensor + - return_water_temperature_sensor uses: - - water_riser_mode - - supply_water_valve_percentage_command + - water_riser_mode + - supply_water_valve_percentage_command DPHC4: guid: "3d81e58b-2596-4a8a-97d2-8ef62de6b823" description: "Four pipe heating and cooling controls for radiant panels" is_abstract: true opt_uses: - - heating_supply_water_temperature_sensor - - heating_return_water_temperature_sensor - - chilled_supply_water_temperature_sensor - - chilled_return_water_temperature_sensor + - heating_supply_water_temperature_sensor + - heating_return_water_temperature_sensor + - chilled_supply_water_temperature_sensor + - chilled_return_water_temperature_sensor uses: - - cooling_output_percentage_command - - heating_output_percentage_command + - cooling_output_percentage_command + - heating_output_percentage_command HHCD42: guid: "994cd48f-ef49-4aa6-8be6-98f05d17c0b7" @@ -6334,24 +6334,24 @@ HHCD42: Heating or cooling only" is_abstract: true implements: - - MONITORING + - MONITORING uses: - - heating_supply_water_isolation_valve_status - - heating_return_water_isolation_valve_status - - chilled_supply_water_isolation_valve_status - - chilled_return_water_isolation_valve_status - - chilled_water_valve_percentage_command - - heating_water_valve_percentage_command - - secondary_heating_supply_water_temperature_sensor - - secondary_heating_return_water_temperature_sensor - - secondary_chilled_supply_water_temperature_sensor - - secondary_chilled_return_water_temperature_sensor - - heating_request_count - - cooling_request_count + - heating_supply_water_isolation_valve_status + - heating_return_water_isolation_valve_status + - chilled_supply_water_isolation_valve_status + - chilled_return_water_isolation_valve_status + - chilled_water_valve_percentage_command + - heating_water_valve_percentage_command + - secondary_heating_supply_water_temperature_sensor + - secondary_heating_return_water_temperature_sensor + - secondary_chilled_supply_water_temperature_sensor + - secondary_chilled_return_water_temperature_sensor + - heating_request_count + - cooling_request_count opt_uses: - - average_zone_air_temperature_sensor - - primary_chilled_supply_water_temperature_sensor - - primary_heating_supply_water_temperature_sensor + - average_zone_air_temperature_sensor + - primary_chilled_supply_water_temperature_sensor + - primary_heating_supply_water_temperature_sensor HHCD44: guid: "da375227-c57b-4818-91ab-c7e9060ad1cc" @@ -6361,86 +6361,86 @@ HHCD44: Heating and cooling in parallel" is_abstract: true implements: - - MONITORING + - MONITORING uses: - - heating_supply_water_isolation_valve_status - - heating_return_water_isolation_valve_status - - chilled_supply_water_isolation_valve_status - - chilled_return_water_isolation_valve_status - - chilled_water_valve_percentage_command - - heating_water_valve_percentage_command - - secondary_heating_supply_water_temperature_sensor - - secondary_heating_return_water_temperature_sensor - - secondary_chilled_supply_water_temperature_sensor - - secondary_chilled_return_water_temperature_sensor - - heating_request_count - - cooling_request_count + - heating_supply_water_isolation_valve_status + - heating_return_water_isolation_valve_status + - chilled_supply_water_isolation_valve_status + - chilled_return_water_isolation_valve_status + - chilled_water_valve_percentage_command + - heating_water_valve_percentage_command + - secondary_heating_supply_water_temperature_sensor + - secondary_heating_return_water_temperature_sensor + - secondary_chilled_supply_water_temperature_sensor + - secondary_chilled_return_water_temperature_sensor + - heating_request_count + - cooling_request_count opt_uses: - - average_zone_air_temperature_sensor - - primary_chilled_supply_water_temperature_sensor - - primary_heating_supply_water_temperature_sensor + - average_zone_air_temperature_sensor + - primary_chilled_supply_water_temperature_sensor + - primary_heating_supply_water_temperature_sensor RCO2M: guid: "09a6c4bb-9bb3-4318-aa43-8ad379493788" description: "Return air co2 monitoring" is_abstract: true uses: - - return_air_co2_concentration_sensor + - return_air_co2_concentration_sensor implements: - - MONITORING + - MONITORING VMADC: guid: "796e1551-7648-40cf-962d-9bbb28c8056b" description: "Variable mixed air damper monitoring (for recirculated air in AHU)." is_abstract: true uses: - - mixed_air_damper_percentage_command - - mixed_air_damper_percentage_sensor + - mixed_air_damper_percentage_command + - mixed_air_damper_percentage_sensor implements: - - CONTROL + - CONTROL OAQM: guid: "99e4f482-278e-40ee-9524-9f687c41ba22" description: "Outside air quality monitoring (particulates and gases)" is_abstract: true uses: - - outside_air_pm1pt0_density_sensor - - outside_air_pm2pt5_density_sensor - - outside_air_pm10pt0_density_sensor - - outside_air_no_density_sensor - - outside_air_no2_density_sensor - - outside_air_so2_density_sensor - - outside_air_co_concentration_sensor + - outside_air_pm1pt0_density_sensor + - outside_air_pm2pt5_density_sensor + - outside_air_pm10pt0_density_sensor + - outside_air_no_density_sensor + - outside_air_no2_density_sensor + - outside_air_so2_density_sensor + - outside_air_co_concentration_sensor opt_uses: - - outside_air_co2_concentration_sensor + - outside_air_co2_concentration_sensor implements: - - MONITORING + - MONITORING VSMC: guid: "6ff088d6-002e-4842-85a1-c40d3aef52a3" description: "Variable speed control mode." is_abstract: true uses: - - speed_mode - - run_command - - run_status + - speed_mode + - run_command + - run_status opt_uses: - - low_speed_status - - high_speed_status - - schedule_run_command + - low_speed_status + - high_speed_status + - schedule_run_command ZOC: description: "Occupancy counter monitoring" is_abstract: true uses: - - zone_occupant_counter + - zone_occupant_counter implements: - - MONITORING + - MONITORING SPLM: description: "Sound pressure level monitoring" is_abstract: true uses: - - soundpressurelevel_sensor + - soundpressurelevel_sensor implements: - - MONITORING + - MONITORING From 6412c66cd6d326182d164081e02c16bc1137ba8d Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 21 Aug 2023 09:01:02 +0100 Subject: [PATCH 17/26] more auto formatting fixes --- .../resources/HVAC/entity_types/ABSTRACT.yaml | 406 +++++++++++++++++- 1 file changed, 394 insertions(+), 12 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 67ebfdf001..a5a58d8cbc 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -41,6 +41,7 @@ SD: implements: - CONTROL + RDM: guid: "9b0b6094-b092-4d27-b894-6dbc299e4833" description: "Very basic system run duration monitoring. " @@ -50,6 +51,7 @@ RDM: implements: - MONITORING + DD: guid: "5b09f1bd-f526-4d77-b1a3-1fceda2ba041" description: "Dual duct flow control (hot deck, cold deck)." @@ -73,6 +75,7 @@ DD: implements: - CONTROL + SRC: guid: "0b8da138-b5be-42d1-81ad-13d4196f5352" description: "Very basic run scheduling command. " @@ -90,6 +93,7 @@ OADM: uses: - outside_air_damper_command + MOAFC: guid: "76994bbd-4395-4a19-914f-d5c9a21fc99b" description: "Minimum (ventilation) outside air flow control." @@ -103,6 +107,7 @@ MOAFC: implements: - CONTROL + OAFC: guid: "9a39e296-caaa-41d8-a1b2-af9255eb4019" description: "Outside Air Flow Control" @@ -118,6 +123,7 @@ OAFC: implements: - CONTROL + ZTM: guid: "869b8713-9b16-4ca0-b957-630c26e9e506" description: "Zone temperature monitoring." @@ -133,6 +139,7 @@ ZTM: implements: - MONITORING + REFM: guid: "df97ad55-5e8f-4cc2-89b7-c07b7a6f28b4" description: "Refrigerant leak monitoring." @@ -142,6 +149,7 @@ REFM: uses: - zone_air_refrigerant_concentration_sensor + CSP: guid: "d741e3d6-4997-4a01-8ac1-07b6ff6d53a7" description: "Single cooling setpoint control (IDF room typically)." @@ -160,6 +168,7 @@ CSP: - zone_air_cooling_temperature_setpoint - zone_air_temperature_sensor + ZTC: guid: "6140021d-52a9-4d7c-8846-ca296ab32aa2" description: "Single control setpoint with deadband." @@ -177,6 +186,7 @@ ZTC: - zone_air_temperature_sensor - zone_air_temperature_setpoint + DSARC: guid: "d891cb1e-f38c-4bec-ae0f-80cc00e2a346" description: "AHU dual supply air reset control." @@ -193,6 +203,7 @@ DSARC: implements: - CONTROL + DFMSS: guid: "d2e28e09-b84b-479a-85a6-f3494b50c7d3" description: "Discharge fan Start Stop with uneven statuses." @@ -210,6 +221,7 @@ DFMSS: - discharge_fan_run_status_1 - discharge_fan_run_status_2 + DX2RC: guid: "3ffa6782-30f3-4e94-9a5d-a6a2fa47c91a" description: "Compressor run control on retun side (RC)." @@ -233,6 +245,7 @@ DX2RC: implements: - CONTROL + DFSMC: guid: "c9972693-cc8b-4191-ba3c-d0306e961ca7" description: "Discharge fan multi-speed control." @@ -241,6 +254,7 @@ DFSMC: - discharge_fan_run_command - discharge_fan_speed_mode + DSP: guid: "662d48d1-95a9-4e23-a6e1-daf2fc80d676" description: "Dual setpoint control (heating/cooling thresholds with deadband in between)." @@ -259,6 +273,7 @@ DSP: - zone_air_heating_temperature_setpoint - zone_air_temperature_sensor + DDSP: guid: "079307e1-3bd4-4f90-9c00-66961afbda6a" description: "Dual setpoint control (heating/cooling thresholds with deadband in between) with two zone temp sensors." @@ -274,6 +289,7 @@ DDSP: - zone_air_temperature_sensor_1 - zone_air_temperature_sensor_2 + CO2C: guid: "d2659eb3-d7a4-450a-9152-da9b30c9a267" description: "Carbon dioxide control." @@ -286,6 +302,7 @@ CO2C: opt_uses: - high_zone_air_co2_concentration_alarm + CO2CDSP: guid: "668a3a75-e78d-4755-a360-b370bceda3c5" description: "Carbon dioxide control with dual setpoint." @@ -298,6 +315,7 @@ CO2CDSP: - zone_air_co2_concentration_sensor opt_uses: - high_zone_air_co2_concentration_alarm + COC: guid: "dee7cc87-51cb-460e-8202-eff4001319db" @@ -332,6 +350,7 @@ BPC: - high_building_air_static_pressure_alarm - low_building_air_static_pressure_alarm + BPC2X: guid: "4c27f34b-0132-44fb-b99a-355ba6a25d6c" description: "Building pressure control for two pressure sensors (stand-alone fan)." @@ -348,6 +367,7 @@ BPC2X: implements: - OPERATIONAL + EDPM: guid: "6051d016-4a78-42f4-aeaf-3701417b8773" description: "Exhaust air damper percentage monitoring." @@ -356,6 +376,7 @@ EDPM: - exhaust_air_damper_percentage_command - exhaust_air_damper_percentage_sensor + EDM: guid: "e765d413-988e-4524-99b6-9869cff2f02e" description: "Exhaust air damper monitoring." @@ -364,6 +385,7 @@ EDM: - exhaust_air_damper_command - exhaust_air_damper_status + EDBPC: guid: "4e428d76-1f7d-46e9-adc6-2affcd170fb6" description: "Building static control with exhaust damper." @@ -380,6 +402,7 @@ EDBPC: implements: - CONTROL + EDRPC: guid: "79013451-90f3-412c-bde5-425c455b2de5" description: "Return static control with exhaust damper." @@ -393,6 +416,7 @@ EDRPC: implements: - CONTROL + EFFC: guid: "45dd6520-570d-43c6-8085-124f1a99196e" description: "Exhaust fan flow control." @@ -404,6 +428,7 @@ EFFC: implements: - CONTROL + BSPC: guid: "78836ff7-b9e6-427d-bbbc-bef212ae6522" description: "Building static pressure control (as part of a composite device)." @@ -421,6 +446,7 @@ BSPC: implements: - CONTROL + VSC: guid: "5ac998b4-d72e-40f1-9c8f-c905ec8b5cc6" description: "Variable speed control generic." @@ -449,6 +475,7 @@ VSC: implements: - OPERATIONAL + EFVSC: guid: "dab0bc02-db86-4b2d-be8d-36a4232ef7c0" description: "Variable speed control for exhaust fans." @@ -468,6 +495,7 @@ EFVSC: implements: - OPERATIONAL + VSFC: guid: "8dcdc4b0-af94-4468-8346-d28442447f84" description: "Variable speed control or monitor in frequency" @@ -476,6 +504,7 @@ VSFC: - speed_frequency_command - speed_frequency_sensor + SFVSC: guid: "ac42c5d1-24d5-4433-b5e5-4ae8843e9ca8" description: "Variable speed control for supply fans." @@ -501,6 +530,7 @@ SFVSC: implements: - OPERATIONAL + DFVSC: guid: "99ebcfbb-f9a5-446f-8faf-ebf61548e2cd" description: "Variable speed control for discharge fans." @@ -526,6 +556,7 @@ DFVSC: implements: - OPERATIONAL + DFVSC2X: guid: "8d7ed5d3-725a-46d7-99e5-6cfbed564551" description: "Variable speed control for discharge fans for 2 separate zones." @@ -551,6 +582,7 @@ DFVSC2X: implements: - OPERATIONAL + DFVSFC: guid: "0f7905ae-ef96-4e44-a52b-10d3fd628de9" description: "Variable speed control with frequency setting for discharge fans." @@ -565,6 +597,7 @@ DFVSFC: implements: - OPERATIONAL + DFMSC: guid: "b9228e0a-91ae-4bcf-911d-f5391941814d" description: "Discharge fan multi-speed control." @@ -578,6 +611,7 @@ DFMSC: - schedule_run_command - failed_discharge_fan_alarm + ZHM: guid: "2832f316-151a-489e-9bd5-0ab159edb0d2" description: "Zone humidity monitoring." @@ -587,6 +621,7 @@ ZHM: uses: - zone_air_relative_humidity_sensor + DTM: guid: "576e2b80-1711-4bac-abed-c54f2db5351d" description: "Discharge temperature monitoring." @@ -600,6 +635,7 @@ DTM: implements: - MONITORING + SS: guid: "5231c7a0-b1bf-48b2-8443-6f37e3b07376" description: "Basic combination of run command and status (start/stop)." @@ -619,6 +655,7 @@ SS: - local_override_alarm - lost_power_alarm + SSPC: guid: "7e0a30ec-8a1d-486c-b9f2-96ae60e695cd" description: "Supply static pressure control via supply fan speed" @@ -639,6 +676,7 @@ SSPC: - supply_air_static_pressure_setpoint implements: - OPERATIONAL + SPSS: guid: "0b1c2a43-53d8-4349-883c-8bde722fccb5" @@ -650,6 +688,7 @@ SPSS: implements: - OPERATIONAL + EFSS: guid: "1df2cdc8-ef3c-472a-ace0-c85d501e121e" description: "Basic combination of exhaust fan run command and status (start/stop)." @@ -667,6 +706,7 @@ EFSS: - exhaust_fan_run_command - exhaust_fan_run_status + DFSS: guid: "969a750f-d5a3-4d4c-ae74-b810d6ddb774" description: "Basic combination of discharge fan run command and status (start/stop)." @@ -688,6 +728,7 @@ DFSS: - discharge_fan_run_command - discharge_fan_run_status + DFSS2X: guid: "dddfd3fa-86a8-4cf9-b1ca-8026ab54f991" description: "Two discharge fan run command and status (start/stop). With dampers" @@ -700,6 +741,7 @@ DFSS2X: - discharge_fan_run_status_1 - discharge_fan_run_status_2 + HT2RC: guid: "3a770fea-bfb4-4a78-a0a1-c33922871fa2" description: "Two gas or electric heater control on zone side (HSP, DSP)." @@ -719,6 +761,7 @@ HT2RC: implements: - CONTROL + HTZTC: guid: "bb4d6089-64cd-4994-9906-2a5555f9155a" description: "Gas or electric heater control on zone side (ZC)." @@ -739,6 +782,7 @@ HTZTC: implements: - CONTROL + HT3ZTC: guid: "bd9a4e2d-2467-43ad-8398-62af5e487ceb" description: "Two gas or electric heater control on zone side (HSP, ZTC)." @@ -760,6 +804,7 @@ HT3ZTC: implements: - CONTROL + HSOUC: guid: "e64d93ac-29cd-46d6-8e4e-6c54db056eb5" description: "Heating occupied/unoccupied setpoint control." @@ -775,6 +820,7 @@ HSOUC: - high_zone_air_temperature_alarm - low_zone_air_temperature_alarm + HTZOUC: guid: "5407057a-7f34-4bc6-bb9f-3b8fa1149f14" description: "Gas or electric heater control on zone side (ZC)." @@ -792,6 +838,7 @@ HTZOUC: implements: - CONTROL + LCC: guid: "f686598b-eac2-4397-bcc5-a11a6a34c071" description: "Leaving coil temperature control." @@ -803,6 +850,7 @@ LCC: implements: - CONTROL + LCC2X: guid: "ad8c876b-1c34-4148-9f3c-43d91613bcb3" description: "Double valve leaving coil temperature control." @@ -815,6 +863,7 @@ LCC2X: implements: - CONTROL + SFSS: guid: "1e8dd2f7-192a-430b-af2c-db6065664deb" description: "Basic combination of supply fan run command and status (start/stop)." @@ -834,6 +883,7 @@ SFSS: - supply_fan_run_command - supply_fan_run_status + RHM: guid: "9b13e30c-52b7-45d1-9798-f7c754e959e9" description: "Return air humidity monitoring." @@ -846,6 +896,7 @@ RHM: - high_return_air_relative_humidity_alarm - low_return_air_relative_humidity_alarm + RTM: guid: "7baf6cba-dc20-47f6-845c-bd71b0fa2ae4" description: "Return air temperature monitoring" @@ -862,6 +913,7 @@ RTM: uses: - return_air_temperature_sensor + DTC: guid: "fa2354f6-694c-4fd6-b5b5-6352eff50fe4" description: "Discharge air temperatore control" @@ -874,6 +926,7 @@ DTC: opt_uses: - failed_discharge_air_temperature_alarm + STC: guid: "68140147-a50c-4ee9-b560-fa78596fbd94" description: "Supply air temperature control" @@ -889,6 +942,7 @@ STC: implements: - OPERATIONAL + RTC: guid: "2145865b-f060-452b-b78b-2fafa6c92b4f" description: "Return air temperature control" @@ -926,6 +980,7 @@ OA: implements: - MONITORING + ZA: guid: "461b178e-e9be-46e6-b8f1-804c138eb17f" description: "Grouped type for zone air psychrometric conditions (RH and temp)" @@ -938,6 +993,7 @@ ZA: - high_zone_air_temperature_alarm - low_zone_air_temperature_alarm + WDT: guid: "0f31290a-83fd-4526-ba80-8cd9c34ce1f9" description: "Temperature differential across water." @@ -951,6 +1007,7 @@ WDT: - high_supply_water_temperature_alarm - low_supply_water_temperature_alarm + CHWDT: guid: "0960d44f-87ff-43f5-b576-c19f8a7f2b83" description: "Temperature differential across chilled water." @@ -961,6 +1018,7 @@ CHWDT: - chilled_return_water_temperature_sensor - chilled_supply_water_temperature_sensor + CHWDPSC: guid: "16555397-2e6c-401c-bb6e-3b93affe444e" description: "Chilled water valve controlling supply air dewpoint temperature." @@ -976,6 +1034,7 @@ CHWDPSC: implements: - CONTROL + CHWDPSC2X: guid: "25b52b13-03b0-4b5b-b241-e088bfdb06c6" description: "Chilled water valves (2x) controlling supply air dewpoint temperature." @@ -991,6 +1050,7 @@ CHWDPSC2X: implements: - CONTROL + CWDT: guid: "3cf2eb19-0557-4565-a72b-4059950f9ac7" description: "Temperature differential across condenser water." @@ -1022,6 +1082,7 @@ SWTC: - supply_water_temperature_sensor - supply_water_temperature_setpoint + RWTC: guid: "e6ef58f6-fbda-421d-ac06-d573b093aecd" description: "Return water temperature control." @@ -1037,6 +1098,7 @@ RWTC: - return_water_temperature_sensor - return_water_temperature_setpoint + PSWTC: guid: "3846a514-83b2-4ec3-afde-295c476a5624" description: "Process water temperature control." @@ -1049,6 +1111,7 @@ PSWTC: implements: - OPERATIONAL + SCHWTC: guid: "d2af9b79-4eb2-4b63-a03a-dc5483372690" description: "Supply chilled water temperature control." @@ -1063,6 +1126,7 @@ SCHWTC: - chilled_supply_water_temperature_sensor - chilled_supply_water_temperature_setpoint + WDPC: guid: "86b2c846-0cc3-4828-8648-88c2082c900e" description: "Differential pressure control in whichever system." @@ -1077,6 +1141,7 @@ WDPC: - differential_pressure_sensor - differential_pressure_setpoint + CGRWTC: guid: "1672a49a-ab80-4989-9ec6-c300d0f44a9e" description: "Cogeneration return water temperature control." @@ -1089,6 +1154,7 @@ CGRWTC: - cogeneration_return_water_temperature_sensor - cogeneration_return_water_temperature_setpoint + WDPC2X: guid: "6e5ff883-c8e2-4e66-8be4-abb9104090c3" description: "Differential pressure control in whichever system, 2 sensors." @@ -1140,6 +1206,7 @@ ETM: opt_uses: - failed_exhaust_air_temperature_alarm + ED: guid: "cfc04603-a257-4077-8181-50b564fbdf96" description: "Exhaust air flow control." @@ -1154,6 +1221,7 @@ ED: implements: - CONTROL + RD: guid: "0aecbeb0-8b01-44a2-a0b6-027a034fb2a5" description: "Return damper flow control." @@ -1165,6 +1233,7 @@ RD: implements: - CONTROL + MTM: guid: "0d7842e9-2af2-4f9f-b2fe-8ba934925103" description: "Mixed air temperature monitoring." @@ -1178,6 +1247,7 @@ MTM: implements: - MONITORING + MTC: guid: "9f3b733e-0af2-4297-8727-8420b6ae595c" description: "Mixed air temperature control." @@ -1190,6 +1260,7 @@ MTC: opt_uses: - failed_mixed_air_temperature_alarm + STM: guid: "974c8ef0-da06-41a9-ab19-f2f08b14d14f" description: "Basic supply temperature monitoring." @@ -1202,6 +1273,7 @@ STM: - high_supply_air_temperature_alarm - low_supply_air_temperature_alarm + STDSPC: guid: "8d61249d-297a-471d-aa62-dda04e1fe8c7" description: "Supply temperature control dual setpoint." @@ -1218,6 +1290,7 @@ STDSPC: implements: - OPERATIONAL + DSPRTC: guid: "4dcf4685-9635-473c-aa83-53661d2b55be" description: "Dual setpoint return air temp control." @@ -1237,6 +1310,7 @@ DSPRTC: implements: - OPERATIONAL + ZHC: guid: "88754caa-5420-4224-92a2-a57bbcd865a6" description: "Zone relative humidity control." @@ -1247,6 +1321,7 @@ ZHC: implements: - OPERATIONAL + RHC: guid: "8c138f85-254c-4b40-8e5c-d1183e7985c0" description: "Return air relative humidity control." @@ -1262,6 +1337,7 @@ RHC: implements: - OPERATIONAL + RHDHC: guid: "d2149dc2-ce5c-4589-b7b1-4ceac68cff2c" description: "Return humidification/dehumidification control." @@ -1280,6 +1356,7 @@ RHDHC: implements: - CONTROL + ZHDHC: guid: "0d8a499a-4934-4860-9d35-277381890e2d" description: "Zone humidification/dehumidification control." @@ -1295,6 +1372,7 @@ ZHDHC: implements: - CONTROL + RHHC: guid: "38ca10af-2a94-4765-be1b-34e9c92ac662" description: "Zone humidification control." @@ -1309,6 +1387,7 @@ RHHC: - return_air_relative_humidity_sensor - return_air_relative_humidity_setpoint + SHC: guid: "c27f33dc-19bc-47f4-937a-eab3293b920f" description: "Supply air relative humidity control." @@ -1325,6 +1404,7 @@ SHC: implements: - OPERATIONAL + SHM: guid: "9b5089f5-e0a1-420d-bad9-682ac34d2516" description: "Supply air relative humidity monitoring." @@ -1334,6 +1414,7 @@ SHM: implements: - MONITORING + REFC: guid: "e043f5e2-fcc4-44b1-818f-0f4e7584adf5" description: "Refrigerant leak control." @@ -1344,6 +1425,7 @@ REFC: implements: - OPERATIONAL + CREFM: guid: "49e6ea15-b389-4741-9a7a-e85c851442e1" description: "Cold Room Refrigerator monitoring." @@ -1365,6 +1447,7 @@ CREFM: - defrost_temperature_sensor - zone_air_temperature_sensor + EPC: guid: "3d28895c-d30d-4316-bfb6-1dd70b8ad698" description: "Exhaust pressure control." @@ -1377,6 +1460,7 @@ EPC: implements: - OPERATIONAL + CO2M: guid: "c73f80ff-e57e-4fe4-8bd6-26e4581b7269" description: "Basic carbon dioxide monitoring." @@ -1388,6 +1472,7 @@ CO2M: opt_uses: - high_zone_air_co2_concentration_alarm + VOCM: guid: "d1d343aa-9b3a-41aa-99fe-850c2ba355a8" description: "Volatile organic compound monitoring." @@ -1397,6 +1482,7 @@ VOCM: implements: - MONITORING + VOCC: guid: "6fec3446-7de8-433e-b644-b760190400df" description: "Volatile organic compound control." @@ -1407,6 +1493,7 @@ VOCC: implements: - OPERATIONAL + RAVOCC: guid: "abaa943a-7d39-42cf-a950-4451cd928316" description: "Volatile organic compound control for return air from zone." @@ -1417,6 +1504,7 @@ RAVOCC: implements: - OPERATIONAL + VOCPC: guid: "37c7c6e1-7b21-4f76-b8fc-dad5b1380227" description: "Volatile organic compound percentage control." @@ -1427,6 +1515,7 @@ VOCPC: implements: - OPERATIONAL + BFSS: guid: "500147cd-91f7-4b7d-837c-bf6e915196a3" description: "Booster fan start-stop and feedback." @@ -1437,6 +1526,7 @@ BFSS: implements: - OPERATIONAL + DFHLC: guid: "4e6e6b09-8b8d-4ba6-bda5-69c581c5ab5f" description: "Discharge fan three-speed (high/low/off) speed control." @@ -1452,6 +1542,7 @@ DFHLC: - OPERATIONAL - REMAP_REQUIRED + DFHMLC: guid: "95365c14-2db6-4e80-ae49-38a2b3d2349f" description: "Discharge fan three-speed (high/medium/low/off) speed control." @@ -1468,6 +1559,7 @@ DFHMLC: - OPERATIONAL - REMAP_REQUIRED + ESPC: guid: "035692f0-48bd-47df-9c7d-53ce80e5e297" description: "Exhaust air static pressure control." @@ -1485,6 +1577,7 @@ ESPC: implements: - OPERATIONAL + SSPM: guid: "48f0296b-4fa2-4af8-8edf-3bc7c9ad169b" description: "Supply static pressure monitoring." @@ -1508,7 +1601,7 @@ DSPM: opt_uses: - high_discharge_air_static_pressure_alarm - low_discharge_air_static_pressure_alarm - + ZSPC: guid: "e7494570-617c-4599-a57e-8e09128e0a07" description: "Zone static pressure control." @@ -1523,6 +1616,7 @@ ZSPC: implements: - OPERATIONAL + ZSPM: guid: "3c3d1d68-4f41-486e-b38c-ff6309f16f2f" description: "Zone static pressure monitoring." @@ -1535,6 +1629,7 @@ ZSPM: - high_zone_air_static_pressure_alarm - low_zone_air_static_pressure_alarm + RSPC: guid: "5b27a493-430f-4a61-8604-0a672ce3fd55" description: "Return air static pressure control." @@ -1545,6 +1640,7 @@ RSPC: implements: - OPERATIONAL + PWDPC: guid: "16200082-13a1-4eea-9868-1b2117bb3871" description: "Process water differential pressure control." @@ -1555,6 +1651,7 @@ PWDPC: implements: - OPERATIONAL + PWDT: guid: "018769f9-995c-4ad7-95fa-eaf02b4c66ee" description: "Primary-side water delta-T monitoring." @@ -1563,6 +1660,7 @@ PWDT: - primary_return_water_temperature_sensor - primary_supply_water_temperature_sensor + CHPM: guid: "83b25b74-a334-4297-89b3-30ce005e12fe" description: "Chiller pressure monitoring." @@ -1577,6 +1675,7 @@ CHPM: - high_differential_pressure_alarm - low_differential_pressure_alarm + ESFM: guid: "71fbb830-8e92-4a1f-8dff-c3ef78825aad" description: " An Electrostatic filter used to maintain air quality its run status and alarm monitoring" @@ -1588,6 +1687,7 @@ ESFM: implements: - MONITORING + FDPM: guid: "dc6d8a45-8ce6-4ac1-b5b5-cf9fd5727034" description: "Filter pressure monitoring." @@ -1618,7 +1718,7 @@ EFDPM: - exhaust_air_filter_alarm implements: - MONITORING - + FDPSM: guid: "9cbbf1cf-51ae-44fd-a5ec-ef9ee7a3fcdf" description: "Filter pressure status monitoring." @@ -1649,6 +1749,7 @@ CHWDC: implements: - CONTROL + CHWSC: guid: "63d00128-355e-4e2f-8cdf-b2d940c4168d" description: "Chilled water valve monitoring on supply side." @@ -1669,6 +1770,7 @@ CHWSC: implements: - CONTROL + CHWSDC: guid: "291c8966-a4c3-4329-9d9a-89226e3bb571" description: "Chilled water valve monitoring on supply side." @@ -1687,6 +1789,7 @@ CHWSDC: implements: - CONTROL + CHW2XSC: guid: "fb42698e-029d-410b-b179-92a25de28ccc" description: "Two chilled water valves." @@ -1707,6 +1810,7 @@ CHW2XSC: implements: - CONTROL + CHWRC: guid: "f9bc8b36-ea88-4318-ab5c-703945fcb465" description: "Chilled water valve monitoring on return side." @@ -1730,6 +1834,7 @@ CHWRC: implements: - CONTROL + CHWZC: guid: "191ee434-574f-4846-a8eb-7415c277804f" description: "Chilled water valve monitoring on zone side (DSP, CSP)." @@ -1753,6 +1858,7 @@ CHWZC: implements: - CONTROL + CHWZTC: guid: "5e9244aa-c51e-42bd-a5ed-f3b12a9cf46e" description: "Chilled water valve monitoring on zone side (ZTC)." @@ -1775,6 +1881,7 @@ CHWZTC: implements: - CONTROL + CHWPVM: guid: "751c1130-6108-49c8-9c55-8bfabb762fa8" description: "Chilled water pressure valve command and position monitoring (without regard to what controls it)." @@ -1786,6 +1893,7 @@ CHWPVM: implements: - OPERATIONAL + CHWZTC2X: guid: "d4e628ff-e44c-43fd-b48e-bb53d0aaeb00" description: "Chilled water valve control on zone side (ZTC) for two separate zones. Chilled water valve controls to the worst zone." @@ -1834,6 +1942,7 @@ DXZTC: implements: - CONTROL + DX2ZTC: guid: "9f49badc-8a3f-4374-abcb-80ac70291893" description: "Compressor run control on zone side (ZTC)." @@ -1860,6 +1969,7 @@ DX2ZTC: implements: - CONTROL + DXZC: guid: "a4e45116-d36c-45e7-8f45-4d0cf279e6ea" description: "Compressor run control on zone side (DSP, CSP)." @@ -1885,6 +1995,7 @@ DXZC: implements: - CONTROL + DXDSPRTC: guid: "27091121-2856-4912-91f0-c3fb7b0db097" description: "Compressor run control with dual return temp control." @@ -1910,6 +2021,7 @@ DXDSPRTC: implements: - CONTROL + DX2ZC: guid: "5af2620a-fafd-4c5e-a1ab-338b9a340377" description: "Two compressor run control on zone side (DSP, CSP)." @@ -1934,6 +2046,7 @@ DX2ZC: implements: - CONTROL + DX3ZC: guid: "f2c6ea3f-6ac8-41b9-83e7-9050429de6de" description: "Three compressor run control on zone side." @@ -1960,6 +2073,7 @@ DX3ZC: implements: - CONTROL + DX4ZC: guid: "0153c2a6-73cc-47f2-aa8d-4b0a5e4c5c57" description: "Four compressor run control on zone side." @@ -1988,6 +2102,7 @@ DX4ZC: implements: - CONTROL + DX2ZC2X: guid: "5170a167-2521-48b8-9728-66f96ecd1af3" description: "Two compressor run control on zone side (DSP, CSP) with two zone temp sensors." @@ -2010,6 +2125,7 @@ DX2ZC2X: implements: - CONTROL + DXSC: guid: "eb52924b-0813-41ac-aca7-471017f7a5f9" description: "Compressor run control on supply air side (STC)." @@ -2033,6 +2149,7 @@ DXSC: implements: - CONTROL + DX2SC: guid: "a58cf1c3-9a2f-4d92-a7ca-54538c642031" description: "Two compressor run control on supply air side." @@ -2055,6 +2172,7 @@ DX2SC: implements: - CONTROL + DX3SC: guid: "da5a00a2-6ea1-4838-9bf7-21d695cd21b4" description: "Three compressor run control on supply air side." @@ -2079,6 +2197,7 @@ DX3SC: implements: - CONTROL + DX4SC: guid: "0d19ab0e-9df1-4dbd-85d9-e1ac214f0882" description: "Four compressor run control on supply air side." @@ -2105,6 +2224,7 @@ DX4SC: implements: - CONTROL + DX2SDC: guid: "4eca020e-b08e-4da5-9dd0-0c9cf8407c4b" description: "Two compressor run control on supply air side (dual temp setpoint)." @@ -2127,6 +2247,7 @@ DX2SDC: implements: - CONTROL + DX4SWC: guid: "beb1f5d7-7ccf-4bb6-8f4e-494d3624589d" description: "Four compressor run control on supply water side." @@ -2152,6 +2273,7 @@ DX4SWC: implements: - CONTROL + DX2SWC: guid: "2b9f2e5b-20f2-45bc-b2f8-68818b02b3ac" description: "Two compressor run control on supply water side." @@ -2174,6 +2296,7 @@ DX2SWC: implements: - CONTROL + DXSWC: guid: "bf02fdd1-5c65-4f62-b552-b629fdace9fb" description: "Compressor run control on supply water side." @@ -2196,6 +2319,7 @@ DXSWC: implements: - CONTROL + DX5SC: guid: "225b9056-c352-4aa7-9613-c97675e97fcd" description: "Five compressor run control on supply side." @@ -2224,6 +2348,7 @@ DX5SC: implements: - CONTROL + DXRC: guid: "58a6126f-413f-4f11-b88d-a44d8395a10d" description: "Compressor run control on return air side (RC)." @@ -2249,6 +2374,7 @@ DXRC: implements: - CONTROL + DXDC: guid: "db862405-dadc-4c5b-8fcd-520cb40439ec" description: "Compressor run control on discharge air side (DTC)." @@ -2271,6 +2397,7 @@ DXDC: implements: - CONTROL + DX2DC: guid: "1e397d80-ffc8-4b31-97fb-db086b95400d" description: "Two compressor run control on discharge side (DTC)." @@ -2293,6 +2420,7 @@ DX2DC: implements: - CONTROL + DX3DC: guid: "5958d6ee-4e00-4dbe-a9e7-9faf649ebd54" description: "Three compressor run control on discharge side (DTC)." @@ -2315,6 +2443,7 @@ DX3DC: implements: - CONTROL + HPSC: guid: "3b23d237-5e53-48f7-a6b7-2279e6c57384" description: "Supply side heat pump control." @@ -2339,6 +2468,7 @@ HPSC: implements: - CONTROL + HP2SC: guid: "69544987-6f30-47e2-80be-84cf8a3aecd2" description: "Supply side heat pump control." @@ -2362,6 +2492,7 @@ HP2SC: implements: - CONTROL + HPDC: guid: "bf9ceadd-45a6-41f3-859c-f67e82348130" description: "Discharge side heat pump control." @@ -2383,6 +2514,7 @@ HPDC: implements: - CONTROL + HPZTC: guid: "0506375b-4a48-4d5d-92ba-5bd1e9ef087b" description: "Zone temp heat pump control (ZTC)." @@ -2408,6 +2540,7 @@ HPZTC: implements: - CONTROL + HPZC: guid: "725460fe-6984-4443-9e16-baaa55076649" description: "Zone temp heat pump control (CSP or DSP)." @@ -2434,6 +2567,7 @@ HPZC: implements: - CONTROL + HP2ZC: guid: "d0e2eb84-4844-4c2a-a8a8-20c40ee94284" description: "Zone temp heat pump control with two compressors." @@ -2459,6 +2593,7 @@ HP2ZC: implements: - CONTROL + HWDC: guid: "353bd503-92eb-4f72-8a82-ec1a91413f89" description: "Heating water valve monitoring on discharge air side." @@ -2477,6 +2612,7 @@ HWDC: implements: - CONTROL + HWRC: guid: "ad089040-996c-4000-aaac-b66c923e8376" description: "Heating water valve monitoring on discharge air side." @@ -2495,6 +2631,7 @@ HWRC: implements: - CONTROL + HWSC: guid: "c74d0eb6-c5b8-4099-9b18-f5880760df44" description: "Heating water valve monitoring on supply air side." @@ -2514,6 +2651,7 @@ HWSC: implements: - CONTROL + HW2SC: guid: "6fed45fd-aa9b-4613-baaa-ed5c44c64f12" description: "Two heating water valves on supply air side." @@ -2532,6 +2670,7 @@ HW2SC: implements: - CONTROL + HWZC: guid: "c0a7f2ca-171a-4cff-b397-99f8506a8409" description: "Heating water valve monitoring on zone side (DSP/CSP)." @@ -2553,6 +2692,7 @@ HWZC: implements: - CONTROL + HWZTC: guid: "fd0e4588-d368-4399-a356-78c8082b282b" description: "Heating water valve monitoring on zone side (ZTC)." @@ -2574,6 +2714,7 @@ HWZTC: implements: - CONTROL + HWSWC: guid: "9e892876-39ed-40ac-befb-c68d96bbb81b" description: "Heating water valve monitoring on supply water side." @@ -2591,6 +2732,7 @@ HWSWC: implements: - CONTROL + PHWSC: guid: "0f2f9a53-6aab-4c9c-801f-bb11b021e42a" description: "Preheating water valve monitoring on supply air side." @@ -2607,6 +2749,7 @@ PHWSC: implements: - CONTROL + HWPVM: guid: "0a51d47f-2d53-4a3b-aa9a-f218394b55a7" description: "Heating water pressure valve command and position monitoring (without regard to what controls it)." @@ -2618,6 +2761,7 @@ HWPVM: implements: - OPERATIONAL + HTDC: guid: "f88f5021-03fa-4aed-a131-c81cac1e354d" description: "Gas or electric heater control on discharge side." @@ -2634,6 +2778,7 @@ HTDC: implements: - CONTROL + HT2DC: guid: "6ca8cf93-24b1-4479-9cbc-d3506a496d3b" description: "Two gas or electric heater control on discharge control." @@ -2651,6 +2796,7 @@ HT2DC: implements: - CONTROL + HTSC: guid: "bf18254f-acb9-4497-9d54-a7920879f5e5" description: "Gas or electric heater control on supply side." @@ -2669,6 +2815,7 @@ HTSC: implements: - CONTROL + HTSDC: guid: "d394c55c-af3d-4956-a3b4-9324e4f32ae9" description: "Gas or electric heater control on supply side." @@ -2687,6 +2834,7 @@ HTSDC: implements: - CONTROL + HTRC: guid: "e51bab3a-ba94-4ef9-892e-3d85dfd53ee1" description: "Gas or electric heater control on return side (RC)." @@ -2707,6 +2855,7 @@ HTRC: implements: - CONTROL + HTZC: guid: "35464e33-c1ee-4d66-a2da-aaee5d9713bf" description: "Gas or electric heater control on zone side (ZC)." @@ -2727,6 +2876,7 @@ HTZC: implements: - CONTROL + HT2ZC: guid: "bcf4b945-b158-4009-9cb9-7cc01dbbe119" description: "Two gas or electric heater control on zone side (HSP, DSP)." @@ -2747,6 +2897,7 @@ HT2ZC: implements: - CONTROL + HT2XZTC2X: guid: "7e2c5241-7e53-4857-ac00-2aec02430150" description: "Two separate heating sections going to two different zones on the device, with independent heating control." @@ -2768,6 +2919,7 @@ HT2XZTC2X: implements: - CONTROL + HT3ZC: guid: "ec69793a-e539-4b5c-bf30-b092ce59cce5" description: "Two gas or electric heater control on zone side (HSP, DSP)." @@ -2788,6 +2940,7 @@ HT3ZC: implements: - CONTROL + HTSWC: guid: "d38fd0c3-d7b8-48c7-9ea2-93211ff4c59e" description: "Two gas or electric heater control on supply water side." @@ -2839,6 +2992,7 @@ HT2SWC: implements: - CONTROL + HT4SWC: guid: "e8633b6d-6096-4824-a4e0-3cf06f0e2170" description: "Four gas or electric heater control on supply water side." @@ -2858,6 +3012,7 @@ HT4SWC: implements: - CONTROL + HT2SC: guid: "5d89ecdf-caaa-4238-8796-1d95a875a81a" description: "Two gas or electric heater control on supply side." @@ -2876,6 +3031,7 @@ HT2SC: implements: - CONTROL + HT3SC: guid: "82b35b25-776f-4829-ada6-42691628d84b" description: "Three gas or electric heater control on supply side." @@ -2895,6 +3051,7 @@ HT3SC: implements: - CONTROL + HT4SC: guid: "211e7507-1925-48ca-a46a-852ca4284c3f" description: "Four gas or electric heater control on supply side." @@ -2915,6 +3072,7 @@ HT4SC: implements: - CONTROL + HT2SDC: guid: "ac906e4b-6e44-445c-90f7-2c6968022b31" description: "Two gas or electric heater control on supply side (dual setpoint)." @@ -2933,6 +3091,7 @@ HT2SDC: implements: - CONTROL + HTVSC: guid: "c2e9d73d-949b-4fcf-8f93-47c25ec15a5e" description: "Variable gas to electric control on supply air side." @@ -2951,6 +3110,7 @@ HTVSC: implements: - CONTROL + ECON: guid: "d4285023-3238-443e-bd85-2d91e1706b48" description: "Economizer mode control" @@ -2979,6 +3139,7 @@ ECON: implements: - CONTROL + ECOND: guid: "2640d584-7b8e-4523-b894-beaf4b13e4c0" description: "Economizer mode control - single zone" @@ -3004,6 +3165,7 @@ ECOND: implements: - CONTROL + ECONM: guid: "729bb0f5-4323-46c6-bfce-176bd4b55869" description: "Economizer mode control" @@ -3030,6 +3192,7 @@ ECONM: implements: - CONTROL + ECONM2X: guid: "ebde3e58-1637-466e-9737-934e07bcd807" description: "Economizer mode control" @@ -3056,6 +3219,7 @@ ECONM2X: implements: - CONTROL + ECONMD: guid: "d19e9024-ddb9-4f1a-8598-f30d52f0beb6" description: "Economizer mode control - single zone" @@ -3081,6 +3245,7 @@ ECONMD: implements: - CONTROL + ECONZ: guid: "a0c19e08-9bb2-4dc3-a65c-4ee050111d65" description: "Economizer mode control - single room" @@ -3111,6 +3276,7 @@ ECONZ: implements: - CONTROL + VOADM: guid: "cfb7089c-d3b6-4afd-829a-aeeb05b6ff15" description: "Variable outside air damper monitoring." @@ -3127,6 +3293,7 @@ VOADM: implements: - MONITORING + BYPDM: guid: "b26b31a9-5a4a-4bd8-87d0-97260e739f32" description: "Bypass damper monitoring." @@ -3136,6 +3303,7 @@ BYPDM: implements: - MONITORING + OAFM: guid: "4d6c951b-f9a2-445d-93d7-a8ab2aa523ad" description: "Outside air flow monitoring" @@ -3148,6 +3316,7 @@ OAFM: implements: - MONITORING + OAFMC: guid: "a33ca954-5287-490f-89bc-c3e2b53ceee5" description: "Outside air flow control with minimum setpoint." @@ -3163,6 +3332,7 @@ OAFMC: implements: - CONTROL + OAMC: guid: "48885f9d-2f9e-4c67-be4f-e558f801e02f" description: "Outside air flow control." @@ -3175,6 +3345,7 @@ OAMC: implements: - CONTROL + OFC: guid: "9e54468c-0ab4-453c-a0e3-a9e70330fef1" description: "Outside air flow control monitoring (without a damper)." @@ -3185,6 +3356,7 @@ OFC: implements: - OPERATIONAL + SFM: guid: "3dcbf69b-ae92-46e8-9b06-4bbb2b16a71f" description: "Supply air flow monitoring." @@ -3194,6 +3366,7 @@ SFM: implements: - MONITORING + DFM: guid: "fcf4568f-324c-49d3-8a57-c1d4fad24973" description: "Discharge air flow monitoring." @@ -3205,6 +3378,7 @@ DFM: opt_uses: - low_discharge_air_flowrate_alarm + SFC: guid: "53328995-5e0c-4929-af9f-052104076d11" description: "Supply air flow control." @@ -3215,6 +3389,7 @@ SFC: implements: - OPERATIONAL + RFC: guid: "a8ff3d29-506c-4d34-aead-af60c4b68cb9" description: "Return air flow control." @@ -3225,6 +3400,7 @@ RFC: implements: - OPERATIONAL + SARC: guid: "8802aca2-e086-43b1-8be2-1df1104a3f5d" description: "AHU supply air reset control." @@ -3240,6 +3416,7 @@ SARC: implements: - CONTROL + RWISOVPC: guid: "8741bbd4-d41e-4313-9c71-85995078216d" description: "Return water isolation valve percentage monitoring." @@ -3252,6 +3429,7 @@ RWISOVPC: implements: - OPERATIONAL + CHWISOVM: guid: "9d50a373-7c09-49e0-8739-4f1fb18b18b5" description: "Chilled water isolation valve monitoring." @@ -3264,6 +3442,7 @@ CHWISOVM: implements: - MONITORING + CDWISOVM: guid: "a90ebfb9-d964-4bc7-aebf-67a72866fd38" description: "Condensing water isolation valve monitoring." @@ -3276,6 +3455,7 @@ CDWISOVM: implements: - MONITORING + CDWISOVPM: guid: "8308f584-0b61-4124-abb9-d8f5ca71e880" description: "Condensing water isolation valve percentage monitoring." @@ -3289,6 +3469,7 @@ CDWISOVPM: implements: - MONITORING + CDWPVM: guid: "588692e6-84a9-4a31-8cc6-09eb599cbe54" description: "Condensing water pressure valve command and position monitoring (without regard to what controls it)." @@ -3300,6 +3481,7 @@ CDWPVM: implements: - OPERATIONAL + CDWFRSM: guid: "2a153a56-29ae-403e-9b4d-9b16b3a4794c" description: "Condenser water flowrate status monitoring." @@ -3309,6 +3491,7 @@ CDWFRSM: implements: - OPERATIONAL + BYPVPM: guid: "57766034-a856-4dfe-b070-fd65673d8dd0" description: "Bypass water valve percentage monitoring." @@ -3320,6 +3503,7 @@ BYPVPM: implements: - MONITORING + MWVPM: guid: "bd83e820-585d-4e03-9142-7d4355b41574" description: "Make-up water valve percentage monitoring." @@ -3329,6 +3513,7 @@ MWVPM: implements: - MONITORING + HXSWISOVPM: guid: "04a7805d-e8ff-4b53-9513-d88ede4635ff" description: "Heat exchanger supply isolation water valve percentage monitoring." @@ -3339,6 +3524,7 @@ HXSWISOVPM: implements: - MONITORING + HXRWISOVPM: guid: "789cd63d-8168-43fe-9245-c54a8527482c" description: "Heat exchanger return isolation water valve percentage monitoring." @@ -3349,6 +3535,7 @@ HXRWISOVPM: implements: - MONITORING + HXSWISOVM: guid: "3a617a80-2ab5-4eb5-9cf5-c327359a03c6" description: "Heat exchanger supply isolation water valve monitoring." @@ -3359,6 +3546,7 @@ HXSWISOVM: implements: - MONITORING + HXRWISOVM: guid: "48cee686-e728-4996-be87-0a280ecf9733" description: "Heat exchanger return isolation water valve monitoring." @@ -3369,6 +3557,7 @@ HXRWISOVM: implements: - MONITORING + PWISOVM: guid: "f4ea38d8-031e-48cd-be80-43883419ed55" description: "Process water iso valve monitoring." @@ -3378,6 +3567,7 @@ PWISOVM: implements: - MONITORING + PWVPM: guid: "2335c3b8-b27f-4ef0-b15b-7df5e8d25e4a" description: "Process water valve percentage monitoring." @@ -3387,6 +3577,7 @@ PWVPM: implements: - MONITORING + CHWBZC: guid: "cbdecbaf-5ddb-4f77-b85f-2fbd92970a70" description: "Chilled water valve binary (open/closed) control." @@ -3403,6 +3594,7 @@ CHWBZC: - high_zone_air_temperature_alarm - low_zone_air_temperature_alarm + CHWBYPVPM: guid: "68cd5104-bf2e-48f3-8b88-c12192509393" description: "Chilled water bypass valve percentage monitoring." @@ -3413,6 +3605,7 @@ CHWBYPVPM: implements: - MONITORING + MXVPM: guid: "4bb25777-d661-4fd3-9f8f-a84b349ada87" description: "Mixing valve percent monitoring." @@ -3422,6 +3615,7 @@ MXVPM: implements: - MONITORING + WFRM: guid: "f92ea2a3-9bbf-4559-b26d-2864a0a9f973" description: "Water flowrate monitoring." @@ -3433,6 +3627,7 @@ WFRM: opt_uses: - low_flowrate_alarm + WFRC: guid: "55e5d148-7001-40e2-b082-d17cafb3309a" description: "Water flowrate control." @@ -3445,6 +3640,7 @@ WFRC: opt_uses: - low_flowrate_alarm + MWFRC: guid: "b98a5846-1b69-47e4-8913-87beb392ddcb" description: "Minimum water flowrate control." @@ -3457,6 +3653,7 @@ MWFRC: opt_uses: - low_flowrate_alarm + CHWFRM: guid: "3a9f9c94-7d1e-4ed2-839f-66ce995e58fd" description: "Chilled water flowrate monitoring." @@ -3466,6 +3663,7 @@ CHWFRM: implements: - MONITORING + CHWFRSM: guid: "b980da9b-c3de-4aab-b6de-8ab6cbc53178" description: "Chilled water flowrate status monitoring." @@ -3475,6 +3673,7 @@ CHWFRSM: implements: - MONITORING + SEPM: guid: "a4c57915-39de-47ef-ae66-643b4e12b180" description: "Shade extent monitoring." @@ -3484,6 +3683,7 @@ SEPM: implements: - MONITORING + STPM: guid: "8221a52f-102f-486e-8ae2-1c5eee8c31d0" description: "Shade tilt monitoring." @@ -3493,6 +3693,7 @@ STPM: implements: - MONITORING + IGM: guid: "ae569be0-3ab9-4f9e-904e-6839aca72b72" description: "Inlet guidevane monitoring." @@ -3502,6 +3703,7 @@ IGM: implements: - OPERATIONAL + CLPM: guid: "603cc89d-c8f4-4ab6-bba2-447a2bd2bbab" description: "Cooling thermal monitoring." @@ -3511,6 +3713,7 @@ CLPM: implements: - MONITORING + PCLPM: guid: "876a8eaa-b0a3-4af7-bdf8-fbef6a93aca5" description: "Process cooling thermal monitoring." @@ -3535,6 +3738,7 @@ DDCO: implements: - CONTROL + FDPM2X: guid: "7ac01e64-eadc-4690-8c12-1bd9f48cd9b3" description: "Filter pressure monitoring (2 sensors)." @@ -3545,6 +3749,7 @@ FDPM2X: implements: - MONITORING + FDPSM2X: guid: "2d883683-d3fc-47c3-8efd-163df172ae9c" description: "Filter pressure status monitoring (2 sensors)." @@ -3558,6 +3763,7 @@ FDPSM2X: implements: - MONITORING + FDPSM4X: guid: "1f150c97-8cd5-436c-ba94-f249c076f498" description: "Filter pressure status monitoring (4 sensors)." @@ -3575,6 +3781,7 @@ FDPSM4X: implements: - MONITORING + FDPM3X: guid: "6b97820b-c413-4c11-ae60-00da68a99b2a" description: "Filter pressure monitoring (3 sensors)." @@ -3586,6 +3793,7 @@ FDPM3X: implements: - MONITORING + FDPM4X: guid: "8d9c1975-d7e4-4e90-829c-8d8454b4bb9d" description: "Filter pressure monitoring (4 sensors)." @@ -3598,6 +3806,7 @@ FDPM4X: implements: - MONITORING + CO2C2X: guid: "4f712687-0690-485d-9e73-4880d30eebf4" description: "Carbon dioxide control with dual zone sensors." @@ -3609,6 +3818,7 @@ CO2C2X: implements: - OPERATIONAL + DSP3X: guid: "c3a47cb2-1af2-4bc0-ac17-59fcb019d09f" description: "Dual setpoint zone temp control with 3 temp sensors." @@ -3625,6 +3835,7 @@ DSP3X: implements: - OPERATIONAL + EFSS2X: guid: "2088a8dd-7821-4782-be8c-6396601bff6e" description: "Exhaust fan start-stop and feedback with two fans." @@ -3644,6 +3855,7 @@ EFSS2X: implements: - OPERATIONAL + EFSS3X: guid: "48635fa0-7a1a-4266-96a1-af3a61f172b8" description: "Exhaust fan start-stop and feedback with three fans." @@ -3667,6 +3879,7 @@ EFSS3X: implements: - OPERATIONAL + EFSS4X: guid: "fd0fd629-4909-4bbe-aaae-3210ba66c6fb" description: "Exhaust fan start-stop and feedback with four fans." @@ -3694,6 +3907,7 @@ EFSS4X: implements: - OPERATIONAL + DF2XSS: guid: "d869bbc9-3715-498f-a923-94f436664cd0" description: "Discharge fan start-stop and feedback (2 pts)." @@ -3710,6 +3924,7 @@ DF2XSS: implements: - OPERATIONAL + SFSS2X: guid: "85ace121-6411-41f7-aea0-03440c7d1352" description: "Supply fan start-stop and feedback for two fans." @@ -3731,6 +3946,7 @@ SFSS2X: implements: - OPERATIONAL + SFSS3X: guid: "e1fba819-60f4-459e-ad37-5da8828618dd" description: "Supply fan start-stop and feedback for three fans." @@ -3754,6 +3970,7 @@ SFSS3X: implements: - OPERATIONAL + SFSS4X: guid: "beae050d-0e1e-4a46-a10e-70cf833126a2" description: "Supply fan start-stop and feedback for four fans." @@ -3781,6 +3998,7 @@ SFSS4X: implements: - OPERATIONAL + EFVSC2X: guid: "71c4f49c-a3be-4f1b-bbf2-dbbda9a13ec2" description: "Exhaust fan variable speed control with feedback and sensoring for two fans." @@ -3804,6 +4022,7 @@ EFVSC2X: implements: - OPERATIONAL + EFVSC3X: guid: "d199dfe8-97a9-4f29-aa27-9f48dafef3fd" description: "Exhaust fan variable speed control with feedback and sensoring for three fans." @@ -3834,6 +4053,7 @@ EFVSC3X: implements: - OPERATIONAL + EFVSC4X: guid: "5c932992-91c9-4184-9f5f-24d62a99e559" description: "Exhaust fan variable speed control with feedback and sensoring for four fans." @@ -3871,6 +4091,7 @@ EFVSC4X: implements: - OPERATIONAL + SFVSC2X: guid: "4ec491a2-e832-4994-8496-e1034006495e" description: "Supply fan variable speed control with feedback and sensoring with two fans." @@ -3894,6 +4115,7 @@ SFVSC2X: implements: - OPERATIONAL + SFVSC3X: guid: "d60c4c55-8265-4ce8-b7a0-b63b93e2c11e" description: "Supply fan variable speed control with feedback and sensoring with three fans." @@ -3936,6 +4158,7 @@ SFVSC3X: implements: - OPERATIONAL + SFVSC4X: guid: "8649a013-b152-4412-bfa6-f681d8a962df" description: "Supply fan variable speed control with feedback and sensoring with four fans." @@ -3973,6 +4196,7 @@ SFVSC4X: implements: - OPERATIONAL + BYPSSPC: guid: "1811cdec-15d7-4d1d-b819-f7673aa694c2" description: "Supply static pressure control with bypass damper." @@ -3991,6 +4215,7 @@ BYPSSPC: implements: - CONTROL + BYPSSPC2X: # Consider virtual point for instances where dampers control to same value. guid: "f4de1232-617b-49c9-adc9-be8810631dbc" description: "Supply static pressure control with bypass damper." @@ -4010,6 +4235,7 @@ BYPSSPC2X: # Consider virtual point for instances where dampers control to same implements: - CONTROL + SWISOVM: guid: "650f3451-5e49-4161-b257-cfc578fb54b4" description: "Supply side isolation valve monitoring." @@ -4023,6 +4249,7 @@ SWISOVM: - failed_isolation_valve_alarm - local_override_isolation_valve_alarm + SWISOVPM: guid: "33856563-ebe5-42ee-a928-e8b46d81772d" description: "Supply side isolation valve monitoring." @@ -4033,6 +4260,7 @@ SWISOVPM: implements: - MONITORING + RWISOVM: guid: "2d35bbb0-bcad-4f36-a8cb-0c9031d81886" description: "Return side isolation valve monitoring." @@ -4043,6 +4271,7 @@ RWISOVM: implements: - MONITORING + RWISOVPM: guid: "a20fce9d-f8c0-4324-9ffd-8aaa3729b32d" description: "Return side isolation valve monitoring." @@ -4053,6 +4282,7 @@ RWISOVPM: implements: - MONITORING + CICHVISOVM3X: guid: "2fb6be93-58f7-4544-ad33-bae7bf47ff0a" description: "Circuit changeover valve for switching between Hot water system and Chiller " @@ -4064,6 +4294,7 @@ CICHVISOVM3X: implements: - MONITORING + CHWRWISOVPM: guid: "0a8333ee-fdc9-440b-9ebc-fb0e19e8cf5c" description: "Return side isolation valve monitoring." @@ -4074,6 +4305,7 @@ CHWRWISOVPM: implements: - MONITORING + CHWRWISOVM: guid: "e9680821-b425-4b3f-bef2-b89795524460" description: "Return side isolation valve monitoring." @@ -4084,6 +4316,7 @@ CHWRWISOVM: implements: - MONITORING + CHWSWISOVPM: guid: "5f1963bf-1148-4881-8c6f-a20b39600e7e" description: "Supply side isolation valve monitoring." @@ -4094,6 +4327,7 @@ CHWSWISOVPM: implements: - MONITORING + CHWSWISOVM: guid: "1a187792-767f-4132-9333-161c6db07ce4" description: "Supply side isolation valve monitoring." @@ -4104,6 +4338,7 @@ CHWSWISOVM: implements: - MONITORING + PRWDT: guid: "cc3605dc-b8bc-4e50-a97c-6a450040bda1" description: "Temperature differential across process water." @@ -4116,6 +4351,7 @@ PRWDT: - process_return_water_temperature_sensor - process_supply_water_temperature_sensor + PRWDT2X: guid: "a84edaa6-abe2-4496-9d44-9d5210573b13" description: "Temperature differential across 2 process water headers." @@ -4131,6 +4367,7 @@ PRWDT2X: - process_supply_water_temperature_sensor_1 - process_supply_water_temperature_sensor_2 + PWFRM: guid: "617bdc3e-24b2-4e1f-b03e-9a179ce4fccd" description: "Flowrate monitoring for process water." @@ -4140,6 +4377,7 @@ PWFRM: uses: - process_water_flowrate_sensor + PWFRM2X: guid: "7ee01573-42e1-4b4b-9dae-8c4950ce6e29" description: "Flowrate monitoring for 2 process water headers." @@ -4150,6 +4388,7 @@ PWFRM2X: - process_water_flowrate_sensor_1 - process_water_flowrate_sensor_2 + PWDPM: guid: "f6ba0e90-e329-4170-96db-1b0ea822db23" description: "Differential pressure monitoring for process water." @@ -4159,6 +4398,7 @@ PWDPM: uses: - process_water_differential_pressure_sensor + PWDPM2X: guid: "95241eea-6d22-400c-aa92-c0e7caf8a4d1" description: "Differential pressure monitoring for 2 process water headers." @@ -4169,6 +4409,7 @@ PWDPM2X: - process_water_differential_pressure_sensor_1 - process_water_differential_pressure_sensor_2 + CWRISOVPM: guid: "ec4e3b78-417d-47a3-bbbf-d031f31d2d3d" description: "Condensing water return isolation monitoring." @@ -4179,6 +4420,7 @@ CWRISOVPM: implements: - MONITORING + CWRISOVM: guid: "cb8b8c1e-30c2-48fc-b6c0-44d73468d994" description: "Condensing water return isolation monitoring." @@ -4189,6 +4431,7 @@ CWRISOVM: implements: - MONITORING + CWSISOVPM: guid: "3221aa75-8df4-4964-82dd-9a5c59c3a73b" description: "Condensing water supply isolation monitoring." @@ -4199,6 +4442,7 @@ CWSISOVPM: implements: - MONITORING + CWSISOVM: guid: "6284c4c0-1261-44f7-bebb-ab6aa11443ca" description: "Condensing water supply isolation monitoring." @@ -4209,6 +4453,7 @@ CWSISOVM: implements: - MONITORING + CHWRISOVPM: guid: "e9fd8609-a3da-4c2a-bd3b-df8692285add" description: "Chilled water return isolation monitoring." @@ -4219,6 +4464,7 @@ CHWRISOVPM: implements: - MONITORING + WDPM: guid: "417a56f9-4c22-454a-8aa9-e6764d9fea8e" description: "Differential pressure monitoring." @@ -4229,6 +4475,7 @@ WDPM: - high_differential_pressure_alarm - low_differential_pressure_alarm + CHWDPM: guid: "dcdb66fc-576b-4475-a1cd-f143e16edcde" description: "Differential pressure monitoring for chilled water." @@ -4236,6 +4483,7 @@ CHWDPM: uses: - chilled_water_differential_pressure_sensor + CHDX4SC: guid: "52c7a4a2-d587-46d5-96c9-d1bdf60daa81" description: "Chiller control." @@ -4258,6 +4506,7 @@ CHDX4SC: - compressor_run_status_3 - compressor_run_status_4 + CHDX2SC: guid: "7383de4b-4fcd-4504-b91a-3fd2576845fb" description: "Chiller control." @@ -4277,6 +4526,7 @@ CHDX2SC: - compressor_run_status_1 - compressor_run_status_2 + CHDXSC: guid: "cc5a8afe-0752-4b8d-846a-5848bf056ddd" description: "Chiller control single stage." @@ -4296,6 +4546,7 @@ CHDXSC: - compressor_run_command - compressor_run_status + CHDXVSC: guid: "7a5e238a-a1b2-4aac-88e3-cffc18960489" description: "Variable speed compressor control." @@ -4312,6 +4563,7 @@ CHDXVSC: - failed_compressor_alarm - overload_compressor_alarm + CDWFRM: guid: "b4cd6a63-df02-4c7b-bf81-3902cd827241" description: "Condenser water flowrate monitoring." @@ -4321,6 +4573,7 @@ CDWFRM: implements: - MONITORING + REFSM: guid: "dfcadf28-6b6f-405b-b6f9-c6ac4f445e96" description: "Refrigerant saturation monitoring." @@ -4334,6 +4587,7 @@ REFSM: implements: - MONITORING + PDSCV: guid: "b1eac019-247c-4669-bd66-f70f262f9af7" description: "Pressure-dependent supply damper control for ventilation purposes (CO2 or VOC)." @@ -4344,6 +4598,7 @@ PDSCV: implements: - CONTROL + SDBPC: guid: "881f3d79-d107-4268-83c6-f16e3ae7fb5a" description: "Back-pressure controlling supply damper." @@ -4360,6 +4615,7 @@ SDBPC: implements: - MONITORING + HWVM: guid: "9e86fa93-01d8-4536-815b-1b031b165f3f" description: "Heating water valve command and position monitoring (without regard to what controls it)." @@ -4373,6 +4629,7 @@ HWVM: implements: - OPERATIONAL + CHWVM: guid: "73411f3e-5c42-40cb-8d6c-82f1e2358844" description: "Chilled water valve command and position monitoring (without regard to what controls it)." @@ -4387,6 +4644,7 @@ CHWVM: implements: - OPERATIONAL + RMM: guid: "162df361-7593-4e36-bf41-e7fa667244dd" description: "Run mode monitoring." @@ -4394,6 +4652,7 @@ RMM: uses: - run_mode + DSPZDHC: guid: "365e7bc0-cc71-4fdd-937c-c8be0011636e" description: "Zone dual setpoint humidification/dehumidification control." @@ -4410,6 +4669,7 @@ DSPZDHC: implements: - CONTROL + EFC: guid: "12587490-2e23-4c9c-9b4f-6980f855ed41" description: "Exhaust air flow control." @@ -4420,6 +4680,7 @@ EFC: implements: - OPERATIONAL + DXDDC: guid: "a3f8ff4c-3cfc-4832-a0f3-1526c82b4e9e" description: "DX cooling dual setpoint control on discharge side" @@ -4439,6 +4700,7 @@ DXDDC: implements: - CONTROL + HTDDC: guid: "9e35fc23-e57e-461a-8ad0-09d91a86bb78" description: "gas or electric heating dual setpoint control on discharge side" @@ -4455,6 +4717,7 @@ HTDDC: implements: - CONTROL + REFSM2X: guid: "4690aaf5-e70c-43e0-aabb-38d209b8c2aa" description: "Refrigerant temperature monitoring for 2 circuits." @@ -4472,6 +4735,7 @@ REFSM2X: implements: - MONITORING + REFPM: guid: "a2aeaac3-35be-4e06-89fe-560d7ec5935e" description: "Refrigerant pressure monitoring for single circuits." @@ -4486,6 +4750,7 @@ REFPM: implements: - MONITORING + REFPM2X: guid: "6f2fadec-2b16-4410-8fb5-f6e52c6f13e4" description: "Refrigerant pressure monitoring for 2 circuits." @@ -4498,6 +4763,7 @@ REFPM2X: implements: - MONITORING + SWPSS: guid: "0647053a-4f19-483a-9ad4-4dc4d1472775" description: "Sweeper pump start stop monitoring." @@ -4508,6 +4774,7 @@ SWPSS: implements: - OPERATIONAL + DRPM: guid: "ae1c0c1a-981c-4a56-9640-afd961cf0f9a" description: "Drain pump monitoring." @@ -4522,6 +4789,7 @@ DRPM: implements: - MONITORING + SDM: guid: "40dc57c7-1efd-483d-a2c0-46077595b2b8" description: "Supply air damper monitoring." @@ -4530,6 +4798,7 @@ SDM: - supply_air_damper_command - supply_air_damper_status + ECDDC: guid: "4874434d-75fd-4a18-aca5-70851c77ea0b" description: "Evaporative cooler control on discharge side." @@ -4546,6 +4815,7 @@ ECDDC: implements: - CONTROL + DXSDC: guid: "ea721fc2-16b9-4bb9-9b59-09c9e1ae1362" description: "Compressor run control on supply side, dual setpoints." @@ -4569,6 +4839,7 @@ DXSDC: implements: - CONTROL + ETM4X: guid: "56fb8b0b-74c6-47be-ad97-189b89c4c78a" description: "Basic exhaust temperature monitoring." @@ -4581,6 +4852,7 @@ ETM4X: implements: - MONITORING + DX6SC: guid: "f2fed45c-84e5-4905-b01d-5397cffb7a0e" description: "Six compressor run control on supply air side." @@ -4611,6 +4883,7 @@ DX6SC: implements: - CONTROL + DX2DSPRTC: guid: "d0ac0571-5f48-464c-bd43-dc58ac879fa9" description: "Two-stage compressor run control with dual return temp control." @@ -4634,6 +4907,7 @@ DX2DSPRTC: implements: - CONTROL + HPDSPRTC: guid: "211fecae-8082-4a69-b27d-e39cdaf65362" description: "Heat pump run control with dual return temp control." @@ -4660,6 +4934,7 @@ HPDSPRTC: implements: - CONTROL + DX4DC: guid: "f833b8eb-fdb9-4680-893f-77f87a0a991e" description: "Compressor run control on discharge air side (DTC)." @@ -4684,6 +4959,7 @@ DX4DC: implements: - CONTROL + DX6SWC: guid: "8b0ee974-bc6c-445f-9f5a-25b311e80740" description: "Six compressor run control on supply water side." @@ -4713,6 +4989,7 @@ DX6SWC: implements: - CONTROL + DRSM5X: guid: "24163e23-9488-4804-9d07-9a40ae3f693e" description: "Dryer status monitoring." @@ -4726,6 +5003,7 @@ DRSM5X: implements: - MONITORING + DRSM8X: guid: "69f3f878-0bf0-4544-adbc-2192ac3b6138" description: "Dryer status monitoring." @@ -4742,6 +5020,7 @@ DRSM8X: implements: - MONITORING + AHAC: guid: "f34854e7-cf5e-4477-baaa-e72f80a28bcd" description: "Tag to indicate an after hours activation method e.g. push button associated with this device." @@ -4752,6 +5031,7 @@ AHAC: implements: - OPERATIONAL + DFFC: guid: "118449f6-f7e1-4c5b-ab15-fe67d43a2718" description: "Discharge fan flow control" @@ -4768,6 +5048,7 @@ DFFC: - failed_discharge_fan_alarm - low_discharge_air_flowrate_alarm + EFM: guid: "2dba33f6-54ef-47eb-93ca-d8892ee84a06" description: "Exhaust air flow monitoring" @@ -4777,6 +5058,7 @@ EFM: implements: - OPERATIONAL + SWTM: guid: "353200de-deca-44b5-a664-e725c857a24f" description: "Supply water temperature monitoring." @@ -4792,6 +5074,7 @@ SWTM: uses: - supply_water_temperature_sensor + CWDPM: guid: "d71e1e0d-35d6-4b53-a570-2e12959c951b" description: "Differential pressure monitoring for condenser water." @@ -4801,6 +5084,7 @@ CWDPM: uses: - condensing_water_differential_pressure_sensor + DICM: guid: "0c42ee3c-eb6c-4624-a4ab-4f8f0f483778" description: "Damper isolation control and monitoring. " @@ -4810,6 +5094,7 @@ DICM: - supply_air_isolation_damper_command - supply_air_isolation_damper_open_status + UV: guid: "6f7a15ff-40b1-4c49-b70b-18e409db171b" description: "Ultraviolet lamp operation." @@ -4820,6 +5105,7 @@ UV: - ultraviolet_lamp_run_command - ultraviolet_lamp_run_status + H3X: guid: "dd956d92-525a-4970-86f8-c48ed8e5282a" description: "Heater monitoring." @@ -4834,6 +5120,7 @@ H3X: - heater_run_status_2 - heater_run_status_3 + CHWBRC: guid: "4732dcec-2cab-418e-8c7c-d805f86905e7" description: "Chilled water valve binary (open/closed) monitoring/controlling. Return air temperature control." @@ -4849,6 +5136,7 @@ CHWBRC: - high_return_air_temperature_alarm - low_return_air_temperature_alarm + CHWISOVPM: guid: "d9f7e2fd-391e-48cf-9483-f3f6e19b1b6d" description: "Chllled water isolation valve control." @@ -4859,6 +5147,7 @@ CHWISOVPM: - chilled_water_isolation_valve_percentage_command - chilled_water_isolation_valve_percentage_sensor + CWCS: guid: "e186aea0-5702-4c18-b384-0d95851764c2" description: "Condensing water valve control." @@ -4869,6 +5158,7 @@ CWCS: - condensing_water_valve_percentage_command - condensing_water_valve_percentage_sensor + DPM: guid: "b848804b-3954-4982-9333-5232eae0bd00" description: "Damper percentage control." @@ -4879,6 +5169,7 @@ DPM: - damper_percentage_command - damper_percentage_sensor + DFVSMC: guid: "1e59e4d6-d645-4685-b1a5-e113d5e2100f" description: "Variable speed control mode for discharge fans." @@ -4892,6 +5183,7 @@ DFVSMC: opt_uses: - failed_discharge_fan_alarm + DFVDSC: guid: "38648763-53c2-4464-9133-b42d40dcead3" description: "Discharge fan control with toggled variable or discrete speed control. This allows the fan to run either VFD or discrete speed stages (LOW/MED/HIGH, etc.) and to switch between the mode." @@ -4906,6 +5198,7 @@ DFVDSC: opt_uses: - failed_discharge_fan_alarm + DFVDSFC: guid: "a59a9de7-dd3b-4503-b4fe-49a747fd4a32" description: "Discharge fan control with toggled variable or discrete speed (frequency) control. This allows the fan to run either VFD or discrete speed stages (LOW/MED/HIGH, etc.) and to switch between the mode." @@ -4920,6 +5213,7 @@ DFVDSFC: opt_uses: - failed_discharge_fan_alarm + SSPCSCM: guid: "68f3b34c-09a7-45d5-ad58-79ae6bd78e0b" description: "Supply air static pressure control for supervisor control (Machine learning)." @@ -4932,6 +5226,7 @@ SSPCSCM: opt_uses: - supervisor_alarm + STCSCM: guid: "73c2d23e-eb23-41eb-8b1e-f657a2e6fc89" description: "Supply air temperature control for supervisor control (Machine learning)." @@ -4944,6 +5239,7 @@ STCSCM: opt_uses: - supervisor_alarm + SWTCSCM: guid: "f612f2d0-4b59-4036-ba7d-c1398d12de27" description: "Supply water temperature control for supervisor control (Machine learning)." @@ -4956,6 +5252,7 @@ SWTCSCM: opt_uses: - supervisor_alarm + WDPCSCM: guid: "40d1d42d-50b9-4c13-8213-fa836e3069de" description: "Water differential pressure control for supervisor control (Machine learning)." @@ -4968,6 +5265,7 @@ WDPCSCM: opt_uses: - supervisor_alarm + CSWIVS: guid: "e1e35fec-c621-4346-9992-4c85d31acaac" description: "Condensing return water isolation valve control." @@ -4997,6 +5295,7 @@ CSWIVS: - condensing_return_water_isolation_valve_status_8 - condensing_return_water_isolation_valve_status_9 + CRWIVS: guid: "8ea0f73c-6a13-4196-a63d-f68011597239" description: "Condensing supply water isolation valve control." @@ -5026,6 +5325,7 @@ CRWIVS: - condensing_supply_water_isolation_valve_status_8 - condensing_supply_water_isolation_valve_status_9 + CSWTC: guid: "1e4bca21-e4df-42e2-86ac-d3b2db91e7d2" description: "Condensing supply water temperature control." @@ -5036,6 +5336,7 @@ CSWTC: - condensing_supply_water_temperature_sensor - condensing_supply_water_temperature_setpoint + HTWHLSTC: guid: "f05a9fca-0e82-41d5-bee2-2db157b5630b" description: "Heat wheel which controls supply temperature using speed control." @@ -5069,6 +5370,7 @@ CAM: uses: - condensate_water_alarm + DPHCC: guid: "4719b91a-9a90-4336-a6cb-8d2109d8e572" description: "Two-pipe heating and cooling control. Has a single control valve @@ -5094,6 +5396,7 @@ DPHCC: - water_riser_mode - zone_air_temperature_sensor + HHCDM: guid: "60e8ae3a-2331-40e2-828c-e9b61a560352" description: "Hydronic heating and cooling distribution monitoring" @@ -5110,6 +5413,7 @@ HHCDM: opt_uses: - average_zone_air_temperature_sensor + HHRU: guid: "29f20adc-716d-43ce-81a7-3a8af3bc039d" description: "Hydronic heat recovery unit for ahu's with bypass valve and circulation pump" @@ -5134,6 +5438,7 @@ HHRU: - low_supply_air_temperature_alarm - low_supply_water_temperature_alarm + PHRU: guid: "708f68a9-f6f6-4563-b3a0-9d8f17637ced" description: "heat recovery unit for ahu's with plate heat exchanger valve and bypass damper" @@ -5179,7 +5484,7 @@ PHRUD: - high_discharge_air_temperature_alarm - low_return_air_temperature_alarm - low_discharge_air_temperature_alarm - + CHWDT2X: guid: "956a597b-e5e5-4c1c-9c06-834b7b8d28b4" description: "Temperature differential across chilled water with two sets of sensors." @@ -5192,6 +5497,7 @@ CHWDT2X: - chilled_supply_water_temperature_sensor_1 - chilled_supply_water_temperature_sensor_2 + HLSAFS: guid: "15bc5aa4-939f-420f-9146-17f6835badc0" description: "Duct VAV type with high and low limit setpoint" @@ -5203,6 +5509,7 @@ HLSAFS: implements: - CONTROL + RHDHS: guid: "8b06668f-b1c3-4cda-9fc6-967d06239ae8" description: "Return humidification/dehumidification monitor." @@ -5219,6 +5526,7 @@ RHDHS: - high_return_air_relative_humidity_alarm - low_return_air_relative_humidity_alarm + CO2DFVSC: guid: "e52dd216-585b-447a-9f30-2efe9639f949" description: "Carbon dioxide levels controlled by a variable speed discharge fan." @@ -5232,6 +5540,7 @@ CO2DFVSC: opt_uses: - high_zone_air_co2_concentration_alarm + CO2EFVSC: guid: "9100a54f-3a01-439a-b009-7b4df6bedc1c" description: "Carbon dioxide levels controlled by a variable speed exhaust fan." @@ -5246,6 +5555,7 @@ CO2EFVSC: implements: - CONTROL + RACO2C: guid: "38ba1a66-8aa5-4c79-b755-734804901626" description: "Returned air carbon dioxide levels controls." @@ -5254,6 +5564,7 @@ RACO2C: - return_air_co2_concentration_sensor - return_air_co2_concentration_setpoint + DX2DDC: guid: "fbee3bb9-dc8b-4a49-a3eb-97439d0851bc" description: "Two compressor run control with dual setpoint control on discharge side" @@ -5273,6 +5584,7 @@ DX2DDC: implements: - CONTROL + HWDT: guid: "197d48e2-b069-492d-8ae4-4545b844e3a8" description: "Temperature differential across heating water for heat recovery chiller." @@ -5283,6 +5595,7 @@ HWDT: - heating_return_water_temperature_sensor - heating_supply_water_temperature_sensor + HPDDC: guid: "002edb3a-e58d-4802-9c4b-6dc924d261dc" description: "Dual setpoint discharge side heat pump control." @@ -5306,6 +5619,7 @@ HPDDC: implements: - CONTROL + EC2SC: guid: "6bf5cfa7-5659-4919-8c34-d60c8e931492" description: "Evaporative cooler control on supply side." @@ -5325,6 +5639,7 @@ EC2SC: implements: - CONTROL + HWDDC: guid: "b257d777-1ff2-41d7-8230-58a18d568f40" description: "Heating water valve with dual setpoint control on discharge side." @@ -5342,6 +5657,7 @@ HWDDC: implements: - CONTROL + CFDPM: guid: "be3e3bc0-e927-46a1-9b63-62717fa740ca" description: "Carbon filter pressure monitoring, where specific filter type is required." @@ -5351,6 +5667,7 @@ CFDPM: implements: - MONITORING + VOADM2X: guid: "bce9e194-e5cc-459f-be23-d73af8394b25" description: "Variable outside air damper monitoring, where there are two separate, equal sets of dampers that operate in conjunction." @@ -5371,6 +5688,7 @@ VOADM2X: implements: - MONITORING + EHHRC: guid: "350243a7-bac9-45b8-b614-6ada6cf48ef6" description: "Exhaust hydronic heat recovery coil with an isolation valve." @@ -5383,6 +5701,7 @@ EHHRC: implements: - MONITORING + DPBHCC: guid: "064adc2f-b5aa-4bc6-bd8e-4d72bed60070" description: "Two-pipe binary (open/closed) heating and cooling control. There @@ -5407,6 +5726,7 @@ DPBHCC: implements: - CONTROL + FTC: guid: "26877aed-9bea-44a8-afca-c7dea27d9b35" description: "Floor temperature control, where the temperature sensors are embedded in the floor (as opposed to open to the air)." @@ -5417,6 +5737,7 @@ FTC: implements: - OPERATIONAL + DPCHWHRWSC: guid: "e7feffef-9d26-4393-b02c-8b5a26be97d6" description: "Two-pipe chilled water and heat recovery water control using the same coils." @@ -5444,6 +5765,7 @@ DPCHWHRWSC: implements: - CONTROL + CPVSC2X: guid: "1be3e1ba-1a25-4b9a-9784-e4bbd9313db5" description: "Circulation pump variable speed control with 2 circulation pumps." @@ -5458,6 +5780,7 @@ CPVSC2X: implements: - OPERATIONAL + HWTTC: guid: "141c33da-9691-4e45-a572-3b06402a54d7" description: "Hot water tank temperature control." @@ -5470,6 +5793,7 @@ HWTTC: implements: - OPERATIONAL + PHWTTC: guid: "8da5a38c-e6de-43c1-9888-689c7cd35ff2" description: "Preheating water tank temperature control." @@ -5480,6 +5804,7 @@ PHWTTC: implements: - OPERATIONAL + RCKTM: guid: "8ea49daa-0f94-46fe-a919-8614752b1f9f" description: "Refrigeration circuit monitoring for a DX compressor loop." @@ -5496,6 +5821,7 @@ RCKTM: - refrigerant_suction_superheat_temperature_sensor - refrigerant_suction_temperature_sensor + RCKTM2X: guid: "c8303789-9f0f-4a0f-9f27-474771b554a3" description: "Refrigeration circuits (2x) monitoring for a DX compressor loop." @@ -5522,6 +5848,7 @@ RCKTM2X: - refrigerant_suction_temperature_sensor_1 - refrigerant_suction_temperature_sensor_2 + CCM: guid: "4690242f-f5fe-47cb-9340-771cfc6cecb3" description: "Compressor current monitoring." @@ -5530,6 +5857,7 @@ CCM: - compressor_current_sensor - compressor_run_command + CC2XM: guid: "6eabfba1-1cc6-43d7-a46a-baaaeb0782d5" description: "Compressor current monitoring for 2 compressors." @@ -5546,7 +5874,7 @@ CFCM: is_abstract: true uses: - condensing_fan_current_sensor - + CFCM4X: guid: "3b5df213-0616-400f-a025-69e72cda4d7b" description: "Condenser fan current monitoring for 4 fans." @@ -5580,6 +5908,7 @@ SSSPC: implements: - CONTROL + SCHWISOVPM: guid: "39e76027-e924-48af-a507-dd33948e455b" description: "Secondary chilled water return side isolation valve percentage monitoring." @@ -5590,6 +5919,7 @@ SCHWISOVPM: implements: - MONITORING + SCHWDT: guid: "bafc8c7a-fd40-4cd6-8b95-e3beb268eac9" description: "Secondary-side chilled water delta-T monitoring." @@ -5600,6 +5930,7 @@ SCHWDT: - secondary_chilled_return_water_temperature_sensor - secondary_chilled_supply_water_temperature_sensor + SHWDT: guid: "6dd5a198-e339-406e-9f43-f2682218bd9c" description: "Secondary-side heating water delta-T monitoring." @@ -5610,6 +5941,7 @@ SHWDT: - secondary_heating_return_water_temperature_sensor - secondary_heating_supply_water_temperature_sensor + PCHWDT: guid: "cfb74347-2e51-4034-8e5d-0015bdbe59a5" description: "Temperature differential across primary chilled water loop." @@ -5620,6 +5952,7 @@ PCHWDT: - primary_chilled_return_water_temperature_sensor - primary_chilled_supply_water_temperature_sensor + PHWDT: guid: "06e84e2c-8935-4c9a-80cb-f08890005f4a" description: "Temperature differential across primary heating water loop." @@ -5630,6 +5963,7 @@ PHWDT: - primary_heating_return_water_temperature_sensor - primary_heating_supply_water_temperature_sensor + TDTM: guid: "5c4a89f4-a163-4b73-9064-aa3dfd8361e7" description: "water tank delta-T monitoring." @@ -5640,6 +5974,7 @@ TDTM: implements: - MONITORING + HLPM: guid: "ae617b98-6deb-4c17-8d63-4504feea2988" description: "Heating thermal power sensor." @@ -5649,6 +5984,7 @@ HLPM: implements: - MONITORING + CWRWISOVM: guid: "857f28d7-c853-41bb-929c-23b942bcb5b8" description: "Condensing water supply side isolation valve monitoring." @@ -5659,6 +5995,7 @@ CWRWISOVM: implements: - MONITORING + CWRWISOVPM: guid: "f9c6f9f6-aad8-4ea8-ab7d-fbd343a53830" description: "Condensing water return side isolation valve percentage monitoring." @@ -5669,6 +6006,7 @@ CWRWISOVPM: implements: - MONITORING + OCWRWISOVM: guid: "daec7559-f465-4117-9606-92353b8a1ae1" description: "Open-loop CDW return side isolation valve monitoring." @@ -5679,6 +6017,7 @@ OCWRWISOVM: implements: - MONITORING + OCWRWISOVPM: guid: "16a303e1-ab6a-49d1-8c3b-6e02c6a78cca" description: "Open-loop CDW return side isolation valve monitoring." @@ -5689,6 +6028,7 @@ OCWRWISOVPM: implements: - MONITORING + HWRWISOVM: guid: "a2ca0c24-c44d-44ea-95cb-728da67d7c78" description: "Heating return side isolation valve monitoring." @@ -5699,6 +6039,7 @@ HWRWISOVM: implements: - MONITORING + HWSWISOVM: guid: "1f0a45f0-b5fd-47b3-a870-bd11dccb7239" description: "Heating supply side isolation valve monitoring." @@ -5709,6 +6050,7 @@ HWSWISOVM: implements: - MONITORING + HWRWISOVPM: guid: "b02b1e0e-ca30-4fb0-8700-84225bf8d635" description: "Heating return side isolation valve percentage monitoring." @@ -5719,6 +6061,7 @@ HWRWISOVPM: implements: - MONITORING + DEFSS: guid: "7102dc2c-4f27-4bbb-a9a4-965e71f3ac79" description: "defrost run command and status (start/stop) " @@ -5731,6 +6074,7 @@ DEFSS: opt_uses: - frost_alarm + DEFSTC: guid: "c52e2a01-3e72-449c-9215-93d4af12ffc6" description: "Defrost temperature control." @@ -5741,6 +6085,7 @@ DEFSTC: opt_uses: - frost_alarm + VOADC2X: guid: "c3072c9a-71f4-41e8-a728-c2730f327fc6" description: "Variable outside air damper control and monitoring, where there are two separate, equal sets of dampers that operate in conjunction." @@ -5753,6 +6098,7 @@ VOADC2X: implements: - OPERATIONAL + RAIDC: guid: "07b8b6ca-5fb7-471d-a50e-2ad266eb4a31" description: "Return air isolation damper control and monitoring." @@ -5763,6 +6109,7 @@ RAIDC: opt_uses: - failed_return_air_isolation_damper_alarm + RAIDC3X: guid: "8d678b8d-244a-41b3-9e2b-e72fd5dd1778" description: "Return air isolation damper control and monitoring, where there are three separate, equal sets of dampers that operate in conjunction." @@ -5777,6 +6124,7 @@ RAIDC3X: implements: - MONITORING + RAIDC2X: guid: "a75ae9d1-c1bd-4fb5-9908-cc59f6b2f321" description: "Return air isolation damper control and monitoring, where there are two separate, equal sets of dampers that operate in conjunction." @@ -5789,6 +6137,7 @@ RAIDC2X: implements: - MONITORING + DAIDC2X: guid: "a31bfc83-51f3-4c0f-8f60-eb21bf9e5688" description: "Discharge air isolation damper control and monitoring, where there are two separate, equal sets of dampers that operate in conjunction." @@ -5801,6 +6150,7 @@ DAIDC2X: implements: - MONITORING + DAIDC: guid: "35f6ae55-3f74-4fcc-bfb2-3412670f8d60" description: "Discharge air isolation damper control and monitoring." @@ -5813,6 +6163,7 @@ DAIDC: opt_uses: - failed_discharge_air_isolation_damper_alarm + RAIDC4X: guid: "2a234621-dfb8-4aab-a825-49e3bfc107b6" description: "Return air isolation damper control and monitoring, where there are four separate, equal sets of dampers that operate in conjunction." @@ -5829,6 +6180,7 @@ RAIDC4X: implements: - MONITORING + SAIDC: guid: "9c0ec280-99e6-4f44-9b67-7ea5f4bdfeba" description: "isolation damper status monitoring and control on the supply side." @@ -5841,6 +6193,7 @@ SAIDC: opt_uses: - failed_supply_air_isolation_damper_alarm + SAIDC2X: guid: "2fd14ae4-e0c5-4057-a998-9fe72d27a494" description: "isolation damper status monitoring and control on the supply side, where there are two separate, equal sets of dampers that operate in conjunction." @@ -5853,6 +6206,7 @@ SAIDC2X: implements: - MONITORING + SAIDC3X: guid: "2ad5c08c-1d77-4df3-af6b-92aecc5b8eaa" description: "isolation damper status monitoring and control on the supply side, where there are three separate, equal sets of dampers that operate in conjunction." @@ -5867,6 +6221,7 @@ SAIDC3X: implements: - MONITORING + SSPC2X: guid: "52328bf9-1e7e-42b3-a66d-fbdeabf1105f" description: "Supply static pressure control via supply fan speed with 2 sensors" @@ -5889,6 +6244,7 @@ SSPC2X: implements: - OPERATIONAL + SFMSC: guid: "b95a77b1-35fd-4447-8a8a-f156f6b363b6" description: "Supply fan multi-speed control." @@ -5902,6 +6258,7 @@ SFMSC: - schedule_run_command - failed_supply_fan_alarm + MIPVCM: guid: "59c2ed91-daa7-4f30-916d-78ac67105014" description: "Motor phase-level input current and voltage monitoring." @@ -5919,6 +6276,7 @@ MIPVCM: - average_input_inter_line_motor_voltage_sensor - average_input_line_motor_current_sensor + MIPWM: guid: "c859ef99-c44d-4f64-9fa7-461af73ede05" description: "Motor input power monitoring." @@ -5931,6 +6289,7 @@ MIPWM: - input_motor_frequency_sensor - motor_powerfactor_sensor + MSM: guid: "6994d3a0-7a74-44df-b5d6-88ea384fa22a" description: "Motor speed monitoring for fan." @@ -5944,6 +6303,7 @@ MSM: opt_uses: - failed_discharge_fan_alarm + INVOPWM: guid: "3fe50f00-5db3-4fea-9838-111e78ce489f" description: "Inverter (VFD) output power monitoring." @@ -5956,6 +6316,7 @@ INVOPWM: - input_inverter_frequency_sensor - output_inverter_voltage_sensor + INVIPCM: guid: "d830e49e-08d3-4ae6-a741-7ac12f5215e8" description: "Inverter (VFD) 3-phase input current monitoring." @@ -5967,6 +6328,7 @@ INVIPCM: - input_phase2_line_inverter_current_sensor - input_phase3_line_inverter_current_sensor + CWSWISOVPM: guid: "70698046-b9b1-462c-bb75-3c06d9b7628c" description: "Condensing water supply side isolation valve percentage monitoring." @@ -5977,6 +6339,7 @@ CWSWISOVPM: implements: - MONITORING + GTWFCISOVM: guid: "649fa2ba-7374-49a7-8989-6b6ac728178e" description: "Geothermal water free-cooling isolation valve monitoring; exclusively using ground as heat sink for building load." @@ -5988,6 +6351,7 @@ GTWFCISOVM: implements: - MONITORING + GTWGRISOVM: guid: "a323f1e9-8722-4126-a5be-d8e9c2e27f7d" description: "Geothermal water ground-recharge isolation valve monitoring; rejecting ground heat to atmosphere via cooling towers." @@ -5999,6 +6363,7 @@ GTWGRISOVM: implements: - MONITORING + GTWHEISOVM: guid: "0568720c-dc0f-404a-8139-af79401d0c43" description: "Geothermal water heat-extraction isolation valve monitoring; extracting ground heat to to use in building." @@ -6010,6 +6375,7 @@ GTWHEISOVM: implements: - MONITORING + GTWHRISOVM: guid: "c17a6215-3493-4693-bef1-52e8d079742f" description: "Geothermal water heat-rejection isolation valve monitoring; rejecting building heat to ground." @@ -6021,6 +6387,7 @@ GTWHRISOVM: implements: - MONITORING + COCDSP: guid: "c4c91584-0506-4ba5-95ad-f49d57eb3c67" description: "Dual setpoint CO concentration control." @@ -6034,6 +6401,7 @@ COCDSP: opt_uses: - high_zone_air_co_concentration_alarm + NOCDSP: guid: "df6c124a-fdd8-4422-b33d-56f46d66dbc8" description: "Dual setpoint NO concentration control." @@ -6045,6 +6413,7 @@ NOCDSP: implements: - CONTROL + EFHLC: guid: "6951a8f3-40e6-461a-a225-70041409441f" description: "Two-speed exhaust fan (low/high)." @@ -6078,6 +6447,7 @@ SWCM: - valve_command - valve_status + SCRSS: guid: "636b1262-b08b-4e1b-b130-e1a510b79a0c" description: "Scurbber start stop monitoring." @@ -6108,6 +6478,7 @@ PCM: implements: - MONITORING + PMM: guid: "9c7fa9be-b9ec-46e1-8986-8e70b4ab04e3" description: "Zone air particulate matter monitoring." @@ -6118,6 +6489,7 @@ PMM: implements: - MONITORING + PHWTC: guid: "f2d309b1-dc35-4aa3-8cf8-dc986cc05a79" description: "potable water temperature monitoring and control." @@ -6125,6 +6497,7 @@ PHWTC: uses: - potable_hot_water_temperature_sensor + LM: guid: "debce299-ec12-4d13-86fd-93e0cf10102e" description: "level monitoring of devices storing media." @@ -6133,6 +6506,7 @@ LM: - level_status - percentage_sensor + PLPM: guid: "87da5960-a441-49a1-8f80-05acdbf32426" description: "Pipeline Fluid pressure monitoring" @@ -6140,6 +6514,7 @@ PLPM: uses: - line_pressure_sensor + CO2M4X: guid: "860e4db3-a171-4575-ad91-0002b01ea783" description: "Basic carbon dioxide monitoring for 4 Zones." @@ -6152,6 +6527,7 @@ CO2M4X: implements: - MONITORING + CO2M6X: guid: "3bea6d49-a70b-42c4-bd0c-592991dbf0f5" description: "Basic carbon dioxide monitoring for 6 Zones." @@ -6169,6 +6545,7 @@ CO2M6X: implements: - MONITORING + MIPCVM: guid: "17630266-40d3-4bc5-a9cd-9d70f10ef839" description: "Motor phase-level input current and voltage monitoring." @@ -6180,6 +6557,7 @@ MIPCVM: - average_input_line_motor_current_sensor - input_motor_power_sensor + EPM: guid: "5976839e-9e26-48ef-8d7f-24106a6b7f97" description: "Basic Electrical parameter monitoring." @@ -6194,6 +6572,7 @@ EPM: implements: - MONITORING + DFRMM: guid: "055a7881-d815-4bcd-aba5-2fac9a0d8e42" description: "Discharge fan run mode monitoring." @@ -6203,6 +6582,7 @@ DFRMM: implements: - MONITORING + RDC: guid: "ca7914b6-f639-4d67-a6fc-22f5a4e613ff" description: "Return air damper percentage monitoring" @@ -6213,6 +6593,7 @@ RDC: implements: - MONITORING + RFSS: guid: "2ca79174-7d36-4341-a820-0db83cd9470c" description: "Basic combination of return fan run command and status (start/stop)." @@ -6226,6 +6607,7 @@ RFSS: implements: - OPERATIONAL + RFSS2X: guid: "8a0e3c63-308e-49d1-bab5-2780998cc6ac" description: "Return fan start-stop and feedback with two fan." @@ -6243,6 +6625,7 @@ RFSS2X: implements: - OPERATIONAL + RFVSC: guid: "e36cc2ed-5694-4171-94b0-d32a94bb271c" description: "Variable speed control for a return fan." @@ -6259,6 +6642,7 @@ RFVSC: implements: - OPERATIONAL + RFVSC2X: guid: "3326bd01-506e-4dba-a410-9a34252b2d59" description: "Return fan variable speed control with feedback and sensoring for two fans." @@ -6328,10 +6712,9 @@ DPHC4: HHCD42: guid: "994cd48f-ef49-4aa6-8be6-98f05d17c0b7" - description: - "Hydronic heating and cooling distribution monitoring for change over group with a heat and a cold exchanger. Primary side: Four-pipe installation - with flow control valves for cooling and heating. Two pipe installation with isolation valves on the secondary side towards the radiant panels. - Heating or cooling only" + description: "Hydronic heating and cooling distribution monitoring for change over group with a heat and a cold exchanger. Primary side: Four-pipe installation + with flow control valves for cooling and heating. Two pipe installation with isolation valves on the secondary side towards the radiant panels. + Heating or cooling only" is_abstract: true implements: - MONITORING @@ -6355,10 +6738,9 @@ HHCD42: HHCD44: guid: "da375227-c57b-4818-91ab-c7e9060ad1cc" - description: - "Hydronic heating and cooling distribution monitoring for change over group with a heat and a cold exchanger. Primary side: Four-pipe installation - with flow control valves for cooling and heating. Four pipe installation with isolation valves on the secondary side towards the radiant panels. - Heating and cooling in parallel" + description: "Hydronic heating and cooling distribution monitoring for change over group with a heat and a cold exchanger. Primary side: Four-pipe installation + with flow control valves for cooling and heating. Four pipe installation with isolation valves on the secondary side towards the radiant panels. + Heating and cooling in parallel" is_abstract: true implements: - MONITORING From 2782b871d720a22e099500738f6df2fc8e5264d8 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 21 Aug 2023 09:02:34 +0100 Subject: [PATCH 18/26] Update telemetry_fields.yaml --- .../resources/fields/telemetry_fields.yaml | 6373 +++++++++-------- 1 file changed, 3188 insertions(+), 3185 deletions(-) diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index f136e75e62..0432db94f7 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -15,3188 +15,3191 @@ # Original Field set literals: - - building_air_static_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 249.080024 - - building_air_static_pressure_setpoint: - flexible_min: -249.080024 - flexible_max: 249.080024 - - bypass_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - chilled_supply_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - chilled_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - chilled_supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - chilled_water_bypass_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_water_bypass_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_water_differential_pressure_sensor: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - chilled_water_differential_pressure_setpoint: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - chilled_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_water_isolation_valve_command: - - OPEN - - CLOSED - - chilled_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - circulation_pump_run_status: - - ON - - OFF - - compressor_run_command: - - ON - - OFF - - UNKNOWN - - compressor_run_status: - - ON - - OFF - - UNKNOWN - - compressor_speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - refrigerant_condenser_saturation_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - condensing_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - condensing_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - condensing_supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - condensing_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - water_linearvelocity_sensor: - fixed_min: 0.0 - flexible_max: 5.08001016 - - cooling_output_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - current_sensor: - fixed_min: 0.0 - flexible_max: 200.0 - - torque_sensor: - fixed_min: 0.0 - flexible_max: 678.0 - - differential_pressure_sensor: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - differential_pressure_setpoint: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - discharge_air_cooling_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 310.9259259 - - discharge_air_heating_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - discharge_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - discharge_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - discharge_fan_current_sensor: - fixed_min: 0.0 - flexible_max: 100.0 - - discharge_fan_run_command: - - ON - - OFF - - AUTO - - UNKNOWN - - discharge_fan_run_status: - - ON - - OFF - - AUTO - - UNKNOWN - - discharge_fan_speed_mode: - - AUTO - - LOW - - MEDIUM - - HIGH - - OFF - - VFD - - discharge_fan_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - dryer_run_status: - - ON - - OFF - - economizer_mode: - - ON - - OFF - - AUTO - - evaporator_pressure_sensor: - flexible_min: 0.0 - flexible_max: 2068427.367 - - refrigerant_evaporator_saturation_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - exhaust_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - exhaust_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - exhaust_fan_current_sensor: - fixed_min: 0.0 - flexible_max: 100.0 - - exhaust_fan_power_sensor: - flexible_min: 0.0 - flexible_max: 100000.0 - - exhaust_fan_run_command: - - ON - - OFF - - exhaust_fan_run_status: - - ON - - OFF - - UNKNOWN - - exhaust_fan_speed_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - exhaust_fan_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - exhaust_fan_speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - fan_run_status: - - ON - - OFF - - fan_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - heater_run_command: - - ON - - OFF - - heating_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - inlet_guidevane_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - isolation_damper_status: - - OPEN - - CLOSED - - isolation_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - line_current_sensor: - fixed_min: 0.0 - flexible_max: 10000.0 - - line_powerfactor_sensor: - fixed_min: 0.0 - fixed_max: 1.0 - - loop_chilled_water_differential_pressure_sensor: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - loop_differential_pressure_sensor: - flexible_min: -68947.6 - flexible_max: 344738.0 - - min_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 0.315451 - - min_chilled_water_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 0.315451 - - ventilation_outside_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - ventilation_outside_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 47.19474432 - - ventilation_outside_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 47.19474432 - - mixed_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - outside_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - outside_air_specificenthalpy_sensor: - flexible_min: 11630.0 - flexible_max: 81410.0 - - outside_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 47.19474432 - - outside_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 47.19474432 - - outside_air_pressure_sensor: - flexible_min: 500.0 - flexible_max: 200000.0 - - outside_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - outside_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - outside_air_wetbulb_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - wind_linearvelocity_sensor: - flexible_min: 0.0 - flexible_max: 100.0 - - wind_direction_angle_sensor: - fixed_min: 0.0 - fixed_max: 360.0 - - outside_air_rain_level_sensor: - flexible_min: 0.0 - flexible_max: 0.00005 - - outside_air_voc_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.005 - - power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - return_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - return_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - return_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - return_fan_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - return_fan_power_sensor: - flexible_min: 0.0 - flexible_max: 100000.0 - - return_fan_torque_sensor: - fixed_min: 0.0 - flexible_max: 678.0 - - return_fan_run_command: - - ON - - OFF - - return_fan_run_status: - - ON - - OFF - - UNKNOWN - - return_fan_speed_frequency_command: - flexible_min: -0.5 - flexible_max: 65.0 - - return_fan_speed_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - return_fan_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - return_fan_speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - reversing_valve_command: - - AUTO - - CLOSED - - OPEN - - UNKNOWN - - run_command: - - ON - - OFF - - run_status: - - ON - - OFF - - STANDBY - - speed_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 94.38948864 - - supply_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - supply_air_static_pressure_sensor: - flexible_min: -124.540012 - flexible_max: 2490.80024 - - supply_air_static_pressure_setpoint: - flexible_min: -124.540012 - flexible_max: 2490.80024 - - supply_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - supply_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - supply_fan_current_sensor: - fixed_min: 0.0 - flexible_max: 100.0 - - supply_fan_power_sensor: - flexible_min: 0.0 - flexible_max: 100000.0 - - supply_fan_torque_sensor: - fixed_min: 0.0 - flexible_max: 678.0 - - supply_fan_run_command: - - ON - - OFF - - supply_fan_run_status: - - ON - - OFF - - UNKNOWN - - supply_fan_speed_frequency_command: - flexible_min: -0.5 - flexible_max: 65.0 - - supply_fan_speed_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - supply_fan_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_fan_speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - cooling_request_count: - fixed_min: 0.0 - flexible_max: 500.0 - - heating_request_count: - fixed_min: 0.0 - flexible_max: 250.0 - - pressurization_request_count: - fixed_min: 0.0 - flexible_max: 500.0 - - zone_air_co2_concentration_sensor: - flexible_min: 0.00005 - flexible_max: 0.005 - - zone_air_co2_concentration_setpoint: - flexible_min: 0.00005 - flexible_max: 0.005 - - max_zone_air_co2_concentration_sensor: - flexible_min: 0.00005 - flexible_max: 0.005 - - average_zone_air_co2_concentration_sensor: - flexible_min: 0.00005 - flexible_max: 0.005 - - zone_air_co_concentration_setpoint: - flexible_min: 0.00035 - flexible_max: 0.0015 - - zone_air_cooling_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - zone_air_heating_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - zone_air_refrigerant_concentration_sensor: - flexible_min: 0.00035 - flexible_max: 0.0015 - - zone_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_deadband_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - zone_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - outside_air_co_concentration_sensor: - flexible_min: 0.00035 - flexible_max: 0.0015 - - outside_air_so2_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.002 - - outside_air_no2_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - outside_air_no_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - outside_air_h2s_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - outside_air_ozone_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - outside_air_pm2pt5_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - outside_air_pm10pt0_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - outside_air_pm1pt0_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - outside_air_no_density_sensor: - flexible_min: 0.0 - flexible_max: 0.0002 - - outside_air_no2_density_sensor: - flexible_min: 0.0 - flexible_max: 0.0002 - - outside_air_so2_density_sensor: - flexible_min: 0.0 - flexible_max: 0.002 - - # Additional fields added to cover first hundred buildings - - bypass_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - bypass_return_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - bypass_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_water_isolation_valve_status: - - OPEN - - CLOSED - - circulation_changeover_isolation_valve_status: - - OPEN - - CLOSED - - circulation_pump_run_command: - - ON - - OFF - - cogeneration_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - cogeneration_return_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - cogeneration_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - cold_aisle_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - cooling_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - cooling_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 4.719474432 - - cooling_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 4.719474432 - - dehumidification_run_command: - - ON - - OFF - - dehumidification_run_status: - - ON - - OFF - - discharge_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - discharge_fan_speed_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - dishwasher_run_status: - - ON - - OFF - - east_illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - evaporative_cooler_run_command: - - ON - - OFF - - exhaust_air_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - exhaust_air_static_pressure_sensor: - flexible_min: -996.320096 - flexible_max: 996.320096 - - exhaust_air_static_pressure_setpoint: - flexible_min: -996.320096 - flexible_max: 996.320096 - - filter_differential_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 2490.80024 - - discharge_air_filter_differential_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 2490.80024 - - exhaust_air_filter_differential_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 2490.80024 - - flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 0.315451 - - flue_gas_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 533.1481481 - - heating_stage_run_count: - fixed_min: 0.0 - flexible_max: 10.0 - - heating_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 23.59737216 - - heating_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 23.59737216 - - heating_cooling_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_water_valve_status: - - OPEN - - CLOSED - - high_discharge_fan_speed_command: - - ON - - OFF - - hot_aisle_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - humidification_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - humidification_run_command: - - ON - - OFF - - humidification_run_status: - - ON - - OFF - - discharge_air_damper_command: - - OPEN - - CLOSED - - isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - leaving_heating_coil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - low_discharge_fan_speed_command: - - ON - - OFF - - makeup_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - makeup_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - medium_discharge_fan_speed_command: - - ON - - OFF - - min_outside_air_damper_command: - - OPEN - - CLOSED - - min_outside_air_damper_status: - - OPEN - - CLOSED - - mixed_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - outside_air_damper_command: - - OPEN - - CLOSED - - outside_air_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - outside_air_dewpoint_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 310.9259259 - - primary_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - production_differential_pressure_sensor: - flexible_min: -3450.0 - flexible_max: 344737.8945 - - return_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - return_air_dehumidification_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - return_air_humidification_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - return_air_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - return_water_valve_command: - - OPEN - - CLOSED - - return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - return_water_valve_status: - - OPEN - - CLOSED - - return_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - secondary_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - secondary_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - shade_extent_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - shade_tilt_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - southeast_illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - southwest_illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - speed_frequency_command: - flexible_min: -0.5 - flexible_max: 65.0 - - spray_pump_run_command: - - ON - - OFF - - spray_pump_run_status: - - ON - - OFF - - supply_air_cooling_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - supply_air_heating_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - supply_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_water_valve_command: - - OPEN - - CLOSED - - supply_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_water_valve_status: - - OPEN - - CLOSED - - west_illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - zone_air_co_concentration_sensor: - flexible_min: 0.00035 - flexible_max: 0.0015 - - zone_air_dehumidification_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_humidification_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - ## added on 10/13/2018 - - condensing_water_isolation_valve_command: - - OPEN - - CLOSED - - condensing_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - condensing_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - ## Added on 10/25/2018 - - compressor_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - compressor_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - compressor_lost_power_alarm: - - ACTIVE - - INACTIVE - - east_wind_linearvelocity_sensor: - flexible_min: 0.0 - flexible_max: 44.704 - - west_wind_linearvelocity_sensor: - flexible_min: 0.0 - flexible_max: 44.704 - - condenser_pressure_sensor: - flexible_min: 68947.5789 - flexible_max: 2068427.367 - - chilled_water_valve_command: - - OPEN - - CLOSED - - heating_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - ## Added on 10/30 - - thermal_power_sensor: - flexible_min: 0.0 - flexible_max: 3517000.0 - - discharge_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 94.38948864 - - exercise_mode: - - ON - - OFF - - # Alarms updated to convert the alarm subfield to a point type from measurement descriptor. - - - run_mode: - - COMMISSIONING - - FLUSHING - - HEATING - - COOLING - - NEUTRAL - - OFF - - AUTO - - MANUAL - - DEHUMIDIFY - - FAN_ONLY - - dial_resistance_sensor: - flexible_min: 0.0 - flexible_max: 10000.0 - - zone_occupancy_status: - - OCCUPIED - - UNKNOWN - - UNOCCUPIED - - INACTIVE - - # INACTIVE indicates the device is being overridden to not run, irrespective of occupancy status. - - ## Added on 12/12 - - leaving_cooling_coil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - leaving_cooling_coil_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - heating_water_valve_command: - - OPEN - - CLOSED - - heating_water_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_water_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - exhaust_air_damper_command: - - OPEN - - CLOSED - - ## Added on 2019/02/19 - - heating_stage_run_command: - - ON - - OFF - - return_air_cooling_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - return_air_heating_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - condensing_fan_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - ## Added on 2019/02/27 - - boost_fan_run_command: - - ON - - OFF - - boost_fan_run_status: - - ON - - OFF - - chilled_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - compressor_speed_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - condensing_water_isolation_valve_status: - - OPEN - - CLOSED - - east_building_air_static_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 249.080024 - - east_exhaust_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - exhaust_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 94.38948864 - - exhaust_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 23.59737216 - - exhaust_air_differential_flowrate_sensor: - flexible_min: 0.0 - flexible_max: 23.59737216 - - exhaust_air_differential_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 23.59737216 - - fan_speed_mode: - - OFF - - LOW - - MEDIUM - - HIGH - - AUTO - - MANUAL - - heat_exchange_isolation_valve_command: - - OPEN - - CLOSED - - heat_exchange_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - humidifier_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - mixing_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - preheating_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - return_air_damper_command: - - OPEN - - CLOSED - - return_air_damper_status: - - OPEN - - CLOSED - - return_air_flowrate_sensor: - flexible_min: -0.002359737216 - flexible_max: 94.38948864 - - return_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - return_air_static_pressure_sensor: - flexible_min: -996.320096 - flexible_max: 996.320096 - - return_air_static_pressure_setpoint: - flexible_min: -996.320096 - flexible_max: 996.320096 - - supply_air_dehumidification_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_air_humidification_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_air_isolation_damper_command: - - OPEN - - CLOSED - - west_building_air_static_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 249.080024 - - west_exhaust_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_static_pressure_sensor: - flexible_min: -249.080024 - flexible_max: 249.080024 - - zone_air_static_pressure_setpoint: - flexible_min: -124.540012 - flexible_max: 124.540012 - - zone_air_voc_concentration_sensor: - flexible_min: 0.0001 - flexible_max: 0.0015 - - zone_air_voc_concentration_setpoint: - flexible_min: 0.0001 - flexible_max: 0.0015 - - return_air_voc_concentration_sensor: - flexible_min: 0.0001 - flexible_max: 0.0015 - - return_air_voc_concentration_setpoint: - flexible_min: 0.0001 - flexible_max: 0.0015 - - ## Added on 2019/03/12 - - cooling_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - primary_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - supply_air_isolation_damper_status: - - OPEN - - CLOSED - - ## Added on 2019/03/19 - - cooling_thermal_power_sensor: - flexible_min: 0.0 - flexible_max: 3517000.0 - - cooling_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - exhaust_air_damper_status: - - OPEN - - CLOSED - - east_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - west_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - east_differential_pressure_sensor: - flexible_min: -3447.378945 - flexible_max: 344737.8945 - - west_differential_pressure_sensor: - flexible_min: -3447.378945 - flexible_max: 344737.8945 - - east_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - west_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - process_chilled_return_water_temperature_sensor: - flexible_min: 274.8148148 - flexible_max: 299.8148148 - - process_chilled_supply_water_temperature_sensor: - flexible_min: 274.8148148 - flexible_max: 299.8148148 - - leaving_air_preheating_coil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 310.9259259 - - ## Added on 2019/03/20 - - cooling_stage_run_count: - fixed_min: 0.0 - flexible_max: 500.0 - - min_return_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - process_cooling_thermal_power_sensor: - flexible_min: 0.0 - flexible_max: 3517000.0 - - process_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - process_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - process_supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - process_water_differential_pressure_sensor: - flexible_min: -3447.378945 - flexible_max: 344737.8945 - - process_water_differential_pressure_setpoint: - flexible_min: -3447.378945 - flexible_max: 344737.8945 - - process_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - process_water_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 0.315451 - - process_water_isolation_valve_command: - - OPEN - - CLOSED - - process_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - ## Added on 2019/03/26 - - zone_air_refrigerant_concentration_setpoint: - flexible_min: 0.00035 - flexible_max: 0.0015 - - # Added on 2019/06/03 - - apparent_power_sensor: - fixed_min: 0.0 - flexible_max: 10000000.0 - - energy_accumulator: - fixed_min: 0.0 - flexible_max: 10000000.0 - - average_line_current_sensor: - fixed_min: 0.0 - flexible_max: 2000.0 - - average_line_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - average_inter_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase1_line_current_sensor: - fixed_min: 0.0 - flexible_max: 2000.0 - - phase1_neutral_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase1_phase2_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase1_phase3_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase1_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - phase1_powerfactor_sensor: - flexible_min: -1.5 - flexible_max: 1.5 - - phase2_line_current_sensor: - fixed_min: 0.0 - flexible_max: 2000.0 - - phase2_neutral_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase2_phase3_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase2_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - phase2_powerfactor_sensor: - flexible_min: -1.5 - flexible_max: 1.5 - - phase3_line_current_sensor: - fixed_min: 0.0 - flexible_max: 2000.0 - - phase3_neutral_line_voltage_sensor: - flexible_min: 0.0 - flexible_max: 20000.0 - - phase3_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - phase3_powerfactor_sensor: - flexible_min: -1.5 - flexible_max: 1.5 - - powerfactor_sensor: - flexible_min: -1.5 - flexible_max: 100.0 - - reactive_power_sensor: - flexible_min: -30000000.0 - flexible_max: 30000000.0 - - phase1_reactive_power_sensor: - flexible_min: -30000.0 - flexible_max: 30000.0 - - phase2_reactive_power_sensor: - flexible_min: -30000.0 - flexible_max: 30000.0 - - phase3_reactive_power_sensor: - flexible_min: -30000.0 - flexible_max: 30000.0 - - # Added on 2019/06/27 for Enlighted - - dimmer_percentage_command: # Should be adjusted to brightness_percentage_command - fixed_min: 0.0 - fixed_max: 100.0 - - # Added on 2019/08/13 primarily for GVC - - calendar_sync_status: - - ACCESS_FAILED - - CALENDAR_STARTUP - - CALENDAR_SUCCESS - - SUBSCRIPTION_FAILED - - WAITING_FOR_RESPONSE - - conference_id_hash_label - - conference_id_match_status: - - DOES_NOT_MATCH - - MATCHES - - conference_call_status: - - ACTIVE - - INACTIVE - - matched_event_id_label - - message_counter: - fixed_min: 0.0 - flexible_max: 10000000.0 - - next_event_end_timestamp - - next_event_start_timestamp - - ongoing_event_end_timestamp - - ongoing_event_start_timestamp - - ongoing_event_id_label - - room_calendar_email_label - - user_occupancy_override_status: - - DISABLED - - ENABLED - - # Added on 2019/09/12 for Enlighted: generic light level sensor - - illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - - condensing_water_bypass_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - condensing_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - - heater_run_status: # Added 10/2/2019 - - ON - - OFF - - discharge_fan_power_sensor: - flexible_min: 0.0 - flexible_max: 100000.0 - - outside_air_damper_status: - - OPEN - - CLOSED - - humidification_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - discharge_fan_speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - discharge_air_heating_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - discharge_fan_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - discharge_fan_torque_sensor: - fixed_min: 0.0 - flexible_max: 678.0 - - supply_air_damper_command: - - OPEN - - CLOSED - - supply_air_damper_status: - - OPEN - - CLOSED - - # Added 11/6/2019 - - low_limit_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 0.315451 - - return_water_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - return_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - # Added 11/12/2019 - - - gas_flowrate_sensor: - fixed_min: 0.0 - flexible_max: 0.003932896 - - gas_volume_accumulator: - fixed_min: 0.0 - flexible_max: 0.003932896 - - water_volume_accumulator: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - gas_temperature_sensor: - flexible_min: 283.1481481 - flexible_max: 533.1481481 - - volume_accumulator: - flexible_min: 0 - flexible_max: 318000 - - # Added 12/17/2019 - - cooling_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - cooling_water_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - cooling_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - heating_water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.0315451 - - zone_air_offset_temperature_setpoint: - flexible_min: 254.8148148 - flexible_max: 283.1481481 - - # Added 1/16/2020 - - discharge_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - # Added 2/10/2020 - - supply_water_isolation_valve_command: - - OPEN - - CLOSED - - supply_water_isolation_valve_status: - - OPEN - - CLOSED - - return_water_isolation_valve_command: - - OPEN - - CLOSED - - return_water_isolation_valve_status: - - OPEN - - CLOSED - - chilled_return_water_isolation_valve_command: - - OPEN - - CLOSED - - condensing_return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - condensing_return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - chilled_return_water_isolation_valve_status: - - OPEN - - CLOSED - - # Added 2/11/2020 - - discharge_air_static_pressure_sensor: - flexible_min: -124.540012 - flexible_max: 996.320096 - - # Added 2/12/2020 - - heat_exchange_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - heat_exchange_return_water_isolation_valve_command: - - OPEN - - CLOSED - - heat_exchange_supply_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heat_exchange_return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heat_exchange_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - heat_exchange_return_water_isolation_valve_status: - - OPEN - - CLOSED - - heat_exchange_supply_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - heat_exchange_return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - condensing_return_water_isolation_valve_command: - - OPEN - - CLOSED - - chilled_return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - # Added 2/24/2020 - - chilled_supply_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_supply_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - chilled_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - condensing_return_water_isolation_valve_status: - - OPEN - - CLOSED - - condensing_supply_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - condensing_supply_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - condensing_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - condensing_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - # Added 4/12/20 - - supply_air_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - # Added 6/4/20 - - ventilation_request_count: - fixed_min: 0.0 - flexible_max: 500.0 - - refrigerant_evaporator_pressure_sensor: - flexible_min: 0.0 - flexible_max: 2068427.367 - - refrigerant_condenser_pressure_sensor: - flexible_min: 0.0 - flexible_max: 2068427.367 - - refrigerant_suction_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - refrigerant_discharge_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - low_limit_outside_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - sweeper_pump_run_status: - - ON - - OFF - - sweeper_pump_run_command: - - ON - - OFF - - evaporative_cooler_run_status: - - ON - - OFF - - drain_pump_run_status: - - ON - - OFF - - failed_drain_pump_alarm: - - ACTIVE - - INACTIVE - - water_low_level_status: - - ACTIVE - - INACTIVE - - water_high_level_status: - - ACTIVE - - INACTIVE - - input_motor_power_status: - - ON - - OFF - - # Additional functionality for alarms and status points. - # For alarms, they will end in `alarm` and be two-state. - # Status fields must be distinguished from alarms in that status is an objective qualitative state (flowing/not) whereas alarms are judgmental interpretations of such statuses to draww a conclusion about function (alarm/normal) - - - average_supply_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - average_supply_air_static_pressure_sensor: - flexible_min: -124.540012 - flexible_max: 2490.80024 - - control_mode: - - AUTO - - MANUAL - - OFF - - HEATING - - COOLING - - DEHUMIDIFY - - FAN_ONLY - - cooling_thermal_energy_accumulator: - fixed_min: 0.0 - flexible_max: 3517000.0 - - particle_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - high_limit_supply_air_cooling_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - high_limit_supply_air_heating_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - low_limit_supply_air_ventilation_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - low_limit_supply_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - high_limit_supply_air_flowrate_setpoint: # used when the device doesn't necessarily provide a cooling max flow - flexible_min: 0.0 - flexible_max: 94.38948864 - - schedule_run_command: - - ON - - OFF - - supply_air_dewpoint_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - supply_air_dewpoint_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - ultraviolet_lamp_run_command: - - ON - - OFF - - ultraviolet_lamp_run_status: - - ON - - OFF - - water_leak_cable_distance_sensor: - fixed_min: 0.0 - flexible_max: 304.7999902 - - discharge_air_linearvelocity_setpoint: - fixed_min: 0.0 - flexible_max: 25.4000508 - - # New usage of status as an override for the measurement. - - chilled_water_flowrate_status: - - PRESENT - - ABSENT - - condensing_water_flowrate_status: - - PRESENT - - ABSENT - - discharge_air_static_pressure_status: - - PRESENT - - ABSENT - - filter_differential_pressure_status: - - PRESENT - - ABSENT - - electrostatic_filter_run_status: - - ON - - OFF - - electrostatic_filter_alarm: - - ACTIVE - - INACTIVE - - high_level_status: - - PRESENT - - ABSENT - - low_level_status: - - PRESENT - - ABSENT - - power_status: - - PRESENT - - ABSENT - - # New alarms using alarm as a point type, and existing alarms moved here - # TODO (tsodorff): change these to ALARM/NORMAL after determining how this can be done safely to existing translations. - - fabric_protection_alarm: - - ACTIVE - - INACTIVE - - failed_alarm: - - ACTIVE - - INACTIVE - - filter_alarm: - - ACTIVE - - INACTIVE - - discharge_air_filter_alarm: - - ACTIVE - - INACTIVE - - exhaust_air_filter_alarm: - - ACTIVE - - INACTIVE - - master_alarm: - - ACTIVE - - INACTIVE - - failed_supply_fan_alarm: - - ACTIVE - - INACTIVE - - smoke_alarm: - - ACTIVE - - INACTIVE - - water_leak_alarm: - - ACTIVE - - INACTIVE - - low_differential_pressure_alarm: - - ACTIVE - - INACTIVE - - lost_power_alarm: - - ACTIVE - - INACTIVE - - overload_alarm: - - ACTIVE - - INACTIVE - - overload_compressor_alarm: - - ACTIVE - - INACTIVE - - overload_discharge_fan_alarm: - - ACTIVE - - INACTIVE - - high_pressure_status: - - ACTIVE - - INACTIVE - - low_pressure_status: - - ACTIVE - - INACTIVE - - refrigerant_high_pressure_status: - - ACTIVE - - INACTIVE - - refrigerant_low_pressure_status: - - ACTIVE - - INACTIVE - - failed_humidifier_alarm: - - ACTIVE - - INACTIVE - - failed_heat_exchange_alarm: - - ACTIVE - - INACTIVE - - failed_compressor_alarm: - - ACTIVE - - INACTIVE - - # New fields for lighting and fire systems. - - motion_status: - - PRESENT - - ABSENT - - battery_charge_status: - - CHARGING - - DISCHARGING - - STANDBY - - battery_charge_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - max_battery_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - max_battery_voltage_sensor: - flexible_min: 0.0 - flexible_max: 15.0 - - min_battery_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - min_battery_voltage_sensor: - flexible_min: 0.0 - flexible_max: 15.0 - - failed_battery_alarm: - - ACTIVE - - INACTIVE - - brightness_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - # New fields for emergency systems - - emergency_alarm: - - ACTIVE - - INACTIVE - - broken_cable_alarm: - - ACTIVE - - INACTIVE - - gas_leak_detection_alarm: - - ACTIVE - - INACTIVE - - ammonia_leak_detection_alarm: - - ACTIVE - - INACTIVE - - water_leak_detection_alarm: - - ACTIVE - - INACTIVE - - fire_alarm: - - ACTIVE - - INACTIVE - - supply_water_volume_accumulator: - fixed_min: -0.000315451 - flexible_max: 0.315451 - - valve_command: - - OPEN - - CLOSED - - valve_status: - - OPEN - - CLOSED - - emergency_release_status: - - ACTIVE - - INACTIVE - - position_status: - - OPEN - - CLOSED - - condensing_water_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - entering_cooling_coil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - # We should not use this... represents scavenged outside air from near some heat pumps... - - mixed_outside_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - discharge_fan_lost_power_alarm: - - ACTIVE - - INACTIVE - - low_discharge_air_flowrate_alarm: - - ACTIVE - - INACTIVE - - frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - failed_discharge_fan_alarm: - - ACTIVE - - INACTIVE - - discharge_air_linearvelocity_sensor: - fixed_min: 0.0 - flexible_max: 25.4000508 - - condensing_water_bypass_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - scene_index_command: - fixed_min: 0.0 - flexible_max: 100.0 - - # This is a change - - line_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - phase1_apparent_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - phase2_apparent_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - phase3_apparent_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - # Added for Automatic transfer switch - - source1_phase1_phase2_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - source1_phase2_phase3_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - source1_phase3_phase1_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - source1_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - source2_phase1_phase2_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - source2_phase2_phase3_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - source2_phase3_phase1_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - source2_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - master_mode: - - SOURCEA - - NOSOURCE - - REMOTE - - MANUAL - - source1_lost_power_alarm: - - ACTIVE - - INACTIVE - - source2_lost_power_alarm: - - ACTIVE - - INACTIVE - - generator_status: - - ON - - OFF - - source1_phase1_phase2_over_voltage_status: - - PRESENT - - ABSENT - - source1_phase2_phase3_over_voltage_status: - - PRESENT - - ABSENT - - source1_phase3_phase1_over_voltage_status: - - PRESENT - - ABSENT - - source1_over_voltage_status: - - PRESENT - - ABSENT - - source2_phase1_phase2_over_voltage_status: - - PRESENT - - ABSENT - - source2_phase2_phase3_over_voltage_status: - - PRESENT - - ABSENT - - source2_phase3_phase1_over_voltage_status: - - PRESENT - - ABSENT - - source2_over_voltage_status: - - ACTIVE - - INACTIVE - - switch_position_mode: - - POSITIONA - - POSITIONB - - POSITIONC - - zone_air_voc_percentage_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_voc_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_unoccupied_heating_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - zone_air_occupied_heating_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - zone_air_unoccupied_deadband_temperature_setpoint: - flexible_min: 255.372 - flexible_max: 272.039 - - zone_air_occupied_deadband_temperature_setpoint: - flexible_min: 255.372 - flexible_max: 272.039 - - mixed_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - mixed_air_dewpoint_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - supply_air_isolation_damper_closed_status: - - OPEN - - CLOSED - - supply_air_isolation_damper_open_status: - - OPEN - - CLOSED - - control_status: - - REMOTE - - LOCAL - - zone_scene_command: - - ACTIVE - - INACTIVE - - scene_command: - - ACTIVE - - INACTIVE - - cooling_run_status: - - ON - - OFF - - high_return_air_temperature_alarm: - - ACTIVE - - INACTIVE - - low_return_air_temperature_alarm: - - ACTIVE - - INACTIVE - - high_return_air_relative_humidity_alarm: - - ACTIVE - - INACTIVE - - low_return_air_relative_humidity_alarm: - - ACTIVE - - INACTIVE - - failed_chilled_water_valve_alarm: - - ACTIVE - - INACTIVE - - discharge_fan_speed_frequency_command: - flexible_min: -0.5 - flexible_max: 65.0 - - ultraviolet_lamp_run_mode: - - AUTO - - MANUAL - - discharge_air_flowrate_status: - - ON - - OFF - - damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_fan_lost_power_alarm: - - ACTIVE - - INACTIVE - - panel_alarm: - - ACTIVE - - INACTIVE - - supply_air_flowrate_status: - - ON - - OFF - - return_air_co2_concentration_sensor: - flexible_min: 0.00005 - flexible_max: 0.005 - - return_air_co2_concentration_setpoint: - flexible_min: 0.00005 - flexible_max: 0.005 - - # Added for Machine Learning Pilot - - supervisor_control_mode: - - ENABLED - - DISABLED - - supervisor_run_command: - - ON - - OFF - - supervisor_supply_air_static_pressure_setpoint: - flexible_min: -124.540012 - flexible_max: 2490.80024 - - supervisor_supply_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - program_supply_air_static_pressure_setpoint: - flexible_min: -124.540012 - flexible_max: 2490.80024 - - program_supply_air_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - supervisor_supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - supervisor_differential_pressure_setpoint: - flexible_min: -6894.75789 - flexible_max: 137895.1578 - - program_supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - program_differential_pressure_setpoint: - flexible_min: -6894.75789 - flexible_max: 137895.1578 - - condensate_water_alarm: - - ACTIVE - - INACTIVE - - supply_water_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_water_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - supply_water_valve_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - - total_request_count: - fixed_min: 0.0 - flexible_max: 500.0 - - zone_conditioning_mode: - - HEATING - - COOLING - - AUTO - - OFF - - water_riser_mode: - - OFF - - HEATING - - COOLING - - AUTO - - average_zone_air_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - heating_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - heating_return_water_isolation_valve_command: - - OPEN - - CLOSED - - heating_return_water_isolation_valve_status: - - OPEN - - CLOSED - - cooling_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - cooling_return_water_isolation_valve_command: - - OPEN - - CLOSED - - heating_supply_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_supply_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - maintenance_alarm: - - ACTIVE - - INACTIVE - - condensate_water_pump_alarm: - - ACTIVE - - INACTIVE - - average_illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - illuminance_setpoint: - flexible_min: 0.0 - flexible_max: 5000.0 - - scene_dimmer_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - scene_dimmer_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - low_scene_dimmer_percentage_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - high_scene_dimmer_percentage_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - red_scene_dimmer_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - green_scene_dimmer_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - blue_scene_dimmer_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - dimmer_fade_rate_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - dimmer_fade_time_setpoint: - fixed_min: 0.0 - flexible_max: 30000.0 - - startup_dimmer_percentage_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - dimmer_mode: - - FADING - - RAMPING - - failed_dimmer_alarm: - - ACTIVE - - INACTIVE - - power_command: - - ON - - OFF - - switch_command: - - ON - - OFF - - lighting_switch_status: - - ON - - OFF - - scene_dimmer_command: - - ACTIVE - - INACTIVE - - scene_status: - - ACTIVE - - INACTIVE - - room_occupancy_status: - - OCCUPIED - - UNKNOWN - - UNOCCUPIED - - BYPASS - - STANDBY - - bypass_air_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - circulation_pump_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - circulation_pump_speed_percentage_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - frost_alarm: - - ACTIVE - - INACTIVE - - supply_air_static_pressure_status: - - PRESENT - - ABSENT - - exhaust_air_static_pressure_status: - - PRESENT - - ABSENT - - failed_exhaust_fan_alarm: - - ACTIVE - - INACTIVE - - return_air_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - mixing_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - potable_hot_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_hot_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_hot_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_hot_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - heating_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - heating_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - heating_thermal_power_sensor: - flexible_min: 0.0 - flexible_max: 586142.14 - - heating_thermal_energy_accumulator: - fixed_min: 0.0 - flexible_max: 586142.14 - - max_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 0.315451 - - potable_water_high_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_water_medium_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_water_low_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - heating_supply_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - #Discharge air flow control - - discharge_air_flowrate_setpoint: - flexible_min: 0.0 - flexible_max: 94.38948864 - - #Electrical meter fields - - neutral_line_current_sensor: # A measure of current on the neutral line - fixed_min: 0.0 - flexible_max: 10000.0 - - apparent_energy_accumulator: - fixed_min: 0.0 - flexible_max: 10000000.0 - - #Electrical panel fields - - circuitbreaker_status: - - ON - - OFF - - failed_circuitbreaker_alarm: - - ACTIVE - - INACTIVE - - reactive_energy_accumulator: - flexible_min: -30000000.0 - flexible_max: 30000000.0 - - #Lighting controller battery status - - emergency_battery_status: - - ON - - OFF - - # Condensing water monitoring - - condensing_water_differential_pressure_sensor: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - condensing_water_differential_pressure_setpoint: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - # Heat Wheel Telemetry Fields - - heat_wheel_speed_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - heat_wheel_speed_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - heat_wheel_run_command: - - ON - - OFF - - heat_wheel_run_status: - - ON - - OFF - - # Outside air Isolation Dampers - - outside_air_isolation_damper_command: - - OPEN - - CLOSED - - outside_air_isolation_damper_status: - - OPEN - - CLOSED - - # Exhaust air Isolation Dampers - - exhaust_air_isolation_damper_command: - - OPEN - - CLOSED - - exhaust_air_isolation_damper_status: - - OPEN - - CLOSED - - # Damper status - - damper_status: - - OPEN - - CLOSED - - lighting_percentage_sensor: # For relative ranged illuminance inputs. - fixed_min: 0.0 - fixed_max: 100.0 - - # Air Quality Data - - outside_air_aqi_sensor: - fixed_min: 0.0 - fixed_max: 500.0 - - zone_air_aqi_sensor: - fixed_min: 0.0 - fixed_max: 500.0 - - outside_air_water_vapor_density_sensor: # Equivalent field for absolute humidity - fixed_min: 0.0 - flexible_max: 100.0 - - outside_air_water_vapor_concentration_sensor: # Equivalent field for absolute humidity - flexible_min: 0.0 - flexible_max: 0.016018 - - zone_air_water_vapor_density_sensor: # Equivalent field for absolute humidity - fixed_min: 0.0 - flexible_max: 100.0 - - zone_air_water_vapor_concentration_sensor: # Equivalent field for absolute humidity - flexible_min: 0.0 - flexible_max: 0.016018 - - zone_air_h2s_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - zone_air_so2_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.002 - - zone_air_no2_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - zone_air_formaldehyde_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_ozone_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - zone_air_h2_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.002 - - zone_air_h2s_density_sensor: - fixed_min: 0.0 - flexible_max: 0.0001 - - zone_air_so2_density_sensor: - fixed_min: 0.0 - flexible_max: 0.002 - - zone_air_no2_density_sensor: - fixed_min: 0.0 - flexible_max: 0.0002 - - zone_air_formaldehyde_density_sensor: - fixed_min: 0.0 - flexible_max: 0.000005 - - zone_air_ozone_density_sensor: - fixed_min: 0.0 - flexible_max: 0.00002 - - # First set of PM2.5, PM10, etc. fields. Note that density and concentration - # are differentiated since they return different units of measurement. - - zone_air_pm0pt5_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm1pt0_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm2pt5_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm4pt0_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm10pt0_density_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm0pt5_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm1pt0_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm2pt5_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm4pt0_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm10pt0_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm0pt5_volumetricconcentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm1pt0_volumetricconcentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm2pt5_volumetricconcentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm4pt0_volumetricconcentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - zone_air_pm10pt0_volumetricconcentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - ## New fields for IoT vibration sensor pilot - - fivesecondrolling_max_xaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_max_yaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_max_zaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_min_xaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_min_yaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_min_zaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_rootmeansquare_xaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_rootmeansquare_yaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - fivesecondrolling_rootmeansquare_zaxis_linearacceleration_sensor: - flexible_min: 0.0 - flexible_max: 0.980665 - - local_air_temperature_sensor: - flexible_min: 283.15 - flexible_max: 353.15 - - # New fields for ERV bypass - - bypass_air_damper_command: - - OPEN - - CLOSED - - bypass_air_damper_status: - - OPEN - - CLOSED - - ## New fields for IoT Vibration devices - - tenminutefixed_max_xaxis_linearvelocity_sensor: - flexible_min: 0.0 - flexible_max: 0.1 - - tenminutefixed_max_yaxis_linearvelocity_sensor: - flexible_min: 0.0 - flexible_max: 0.1 - - tenminutefixed_max_zaxis_linearvelocity_sensor: - flexible_min: 0.0 - flexible_max: 0.1 - - tenminutefixed_max_xaxis_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - tenminutefixed_max_yaxis_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - tenminutefixed_max_zaxis_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - signal_strength_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - dutycycle_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - min_zone_air_relative_humidity_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - min_zone_air_relative_humidity_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - ## New fields for air quality sensors - - thirtysecondrolling_average_zone_air_co_concentration_sensor: - flexible_min: 0.00035 - flexible_max: 0.0015 - - thirtysecondrolling_average_zone_air_particle_diameter_sensor: - fixed_min: 0.0 - flexible_max: 0.01 - - zone_air_no2_probability_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - zone_air_no2_ozone_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - #added for new Pre-action Fire Supression system - - supervisor_alarm: - - ACTIVE - - INACTIVE - - water_flowrate_status: - - ACTIVE - - INACTIVE - - air_pressure_status: - - ACTIVE - - INACTIVE - - # added for WM_WFR - - water_flowrate_sensor: - flexible_min: -0.000315451 - flexible_max: 0.315451 - # added for FAN_ST - - air_pressure_sensor: - flexible_min: 500.0 - flexible_max: 200000.0 - - heat_recovery_water_isolation_valve_command: - - OPEN - - CLOSED - - heat_recovery_return_water_isolation_valve_command: - - OPEN - - CLOSED - - heat_recovery_return_water_isolation_valve_status: - - OPEN - - CLOSED - - heat_recovery_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - heat_recovery_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - heat_recovery_run_command: - - ON - - OFF - - exhaust_air_differential_pressure_sensor: - flexible_min: -996.320096 - flexible_max: 996.320096 - - leaving_heat_recovery_coil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - zone_floor_temperature_sensor: - flexible_min: 272.037037 - flexible_max: 305.3703704 - - zone_floor_temperature_setpoint: - flexible_min: 272.037037 - flexible_max: 305.3703704 - - entering_heat_recovery_coil_temperature_sensor: - flexible_min: 277.5925926 - flexible_max: 310.9259259 - - carbon_filter_differential_pressure_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - leaving_coil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - heat_recovery_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - heat_recovery_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 338.7037037 - - differential_temperature_sensor: - flexible_min: 254.8148148 - flexible_max: 380.3703704 - - hot_water_tank_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - hot_water_tank_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - preheating_water_tank_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - preheating_water_tank_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_hot_leaving_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - potable_hot_leaving_water_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - ## New fields for electrical system additions - - voltage_sensor: - flexible_min: 0.0 - flexible_max: 1000.0 - - input_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - output_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - bypass_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - input_phase1_phase2_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase2_phase3_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase3_phase1_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase1_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase2_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase3_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase1_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase2_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase3_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - output_phase1_phase2_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - output_phase2_phase3_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - output_phase3_phase1_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - output_phase1_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - output_phase2_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - output_phase3_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - output_phase1_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - output_phase2_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - output_phase3_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - bypass_phase1_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - bypass_phase2_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - bypass_phase3_neutral_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - remaining_charge_time_sensor: - fixed_min: 0.0 - flexible_max: 100000.0 - - output_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - output_apparent_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - low_battery_charge_alarm: - - ACTIVE - - INACTIVE - - load_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - bypass_status: - - BYPASS - - INACTIVE - - failed_inverter_alarm: - - ACTIVE - - INACTIVE - - ## Refrigerant monitoring fields for AHUs - - condensing_fan_current_sensor: - fixed_min: 0.0 - flexible_max: 100.0 - - discharge_air_specificenthalpy_sensor: - flexible_min: 11630.0 - flexible_max: 81410.0 - - refrigerant_discharge_pressure_sensor: - flexible_min: -34500.0 - flexible_max: 344737.8945 - - refrigerant_liquid_pressure_sensor: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - refrigerant_liquid_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - refrigerant_liquid_saturation_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - refrigerant_subcooling_temperature_sensor: - flexible_min: 227.5925926 - flexible_max: 366.4814815 - - refrigerant_suction_pressure_sensor: - flexible_min: -34473.78945 - flexible_max: 344737.8945 - - refrigerant_suction_saturation_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - refrigerant_suction_superheat_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - return_air_specificenthalpy_sensor: - flexible_min: 11630.0 - flexible_max: 81410.0 - - compressor_current_sensor: - fixed_min: 0.0 - flexible_max: 100.0 - - ## Water Level status - - water_level_status: - - HIGH - - MEDIUM - - LOW - - ## New fields for steam/water heat exchanger - - supply_steam_static_pressure_sensor: - flexible_min: 0.0 - flexible_max: 2068428.0 - - supply_steam_static_pressure_setpoint: - flexible_min: 0.0 - flexible_max: 2068428.0 - - steam_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - # Open-loop CDW system - - outside_condensing_loop_return_water_isolation_valve_status: - - OPEN - - CLOSED - - outside_condensing_loop_return_water_isolation_valve_command: - - OPEN - - CLOSED - - outside_condensing_loop_return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - outside_condensing_loop_return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - outside_condensing_loop_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - # Rodent Repellent system - - transducer_failed_alarm: - - ACTIVE - - INACTIVE - - # Buffer tanks with temperature sensors - - chilled_water_temperature_sensor: - flexible_min: 274.8148148 - flexible_max: 299.8148148 - - heating_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - leaving_water_tank_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - entering_water_tank_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - # Tank level - - percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - secondary_heating_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - secondary_heating_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - primary_heating_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - primary_heating_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 380.3703704 - - secondary_chilled_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - secondary_chilled_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - primary_chilled_supply_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - primary_chilled_return_water_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 308.1481481 - - secondary_chilled_return_water_isolation_valve_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - secondary_chilled_return_water_isolation_valve_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - thermal_energy_accumulator: - fixed_min: 0.0 - flexible_max: 3517000.0 - - ground_isolation_command: - - ON - - OFF - - ground_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 299.8148148 - - ## Addition of new fields# - - ## New fields for Freezer (Walk in Cold room) - - defrost_run_status: - - ON - - OFF - - defrost_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 322.037037 - - discharge_fan_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - defrost_temperature_setpoint: - flexible_min: 255.9259259 - flexible_max: 299.8148148 - - defrost_run_command: - - ON - - OFF - - input_motor_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - input_motor_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - motor_powerfactor_sensor: - fixed_min: 0.0 - fixed_max: 1.0 - - average_input_inter_line_motor_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - average_input_line_motor_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase1_line_motor_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase2_line_motor_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase3_line_motor_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase1_phase3_line_motor_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase1_phase2_line_motor_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase2_phase3_line_motor_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_phase1_line_inverter_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase2_line_inverter_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - input_phase3_line_inverter_current_sensor: - fixed_min: 0.0 - flexible_max: 500.0 - - output_inverter_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - input_inverter_frequency_sensor: - flexible_min: -0.5 - flexible_max: 65.0 - - output_inverter_power_sensor: - flexible_min: 0.0 - flexible_max: 10000000.0 - - refrigerant_differential_pressure_sensor: - flexible_min: -3447.38 - flexible_max: 137895.2 - - chilled_side_ground_supply_economizer_isolation_valve_status: - - OPEN - - CLOSED - - chilled_side_ground_return_economizer_isolation_valve_status: - - OPEN - - CLOSED - - chilled_side_ground_return_economizer_isolation_valve_command: - - OPEN - - CLOSED - - heating_side_ground_supply_economizer_isolation_valve_status: - - OPEN - - CLOSED - - heating_side_ground_return_economizer_isolation_valve_status: - - OPEN - - CLOSED - - heating_side_ground_return_economizer_isolation_valve_command: - - OPEN - - CLOSED - - chilled_side_ground_return_water_isolation_valve_status: - - OPEN - - CLOSED - - chilled_side_ground_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - chilled_side_ground_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - heating_side_ground_return_water_isolation_valve_status: - - OPEN - - CLOSED - - heating_side_ground_supply_water_isolation_valve_status: - - OPEN - - CLOSED - - heating_side_ground_supply_water_isolation_valve_command: - - OPEN - - CLOSED - - ## New fields for Fresh Air Fan With VFD - - output_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - motor_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - # Addition of telemetry for parking exhaust fan - - low_limit_zone_air_co_concentration_setpoint: - flexible_min: 0.00035 - flexible_max: 0.0015 - - high_limit_zone_air_co_concentration_setpoint: - flexible_min: 0.00035 - flexible_max: 0.0015 - - low_limit_zone_air_no_concentration_setpoint: - fixed_min: 0.0 - flexible_max: 0.0005 - - high_limit_zone_air_no_concentration_setpoint: - fixed_min: 0.0 - flexible_max: 0.0005 - - zone_air_no_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.0001 - - low_exhaust_fan_speed_command: - - ON - - OFF - - high_exhaust_fan_speed_command: - - ON - - OFF - - low_exhaust_fan_speed_status: - - ON - - OFF - - high_exhaust_fan_speed_status: - - ON - - OFF - - # Addition of telemetry for UPS battery monitoring - - battery_status: - - ACTIVE - - INACTIVE - - inverter_mode: - - SYNCHRONOUS - - ASYNCHRONOUS - - bypass_phase_status: - - NORMAL - - REVERSED - - rectifier_mode: - - OFF - - ON - - SOFTSTART - - BATTERY - - input_supply_mode: - - NORMAL - - BATTERY - - OFF - - battery_test_status: - - ACTIVE - - INACTIVE - - inverter_status: - - OFF - - ON - - # Addition of telemetry for scrubber - - scrubber_run_mode: - - AUTO - - MANUAL - - scrubber_run_command: - - ON - - OFF - - scrubber_run_status: - - ON - - OFF - - # telemetry fields for exhaust fan# - - speed_mode: - - VFD - - BYPASS - - AUTO - - LOW - - HIGH - - OFF - - high_discharge_fan_speed_status: - - ON - - OFF - - low_discharge_fan_speed_status: - - ON - - OFF - - ##Fields for generator## - - oil_temperature_sensor: - flexible_min: 255.9259259 - flexible_max: 422.037037 - - oil_pressure_sensor: - flexible_min: 0.0 - flexible_max: 1034214.0 - - tank_level_status: - - LOW - - MEDIUM - - HIGH - - battery_voltage_sensor: - flexible_min: 0.0 - flexible_max: 15.0 - - battery_current_sensor: - fixed_min: 0.0 - flexible_max: 1.0 - - battery_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - #Telemetry addition for MAU# - - #Telemetry fields for APU(MAU)# - - dc_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - ac_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - supply_fan_run_mode: - - AUTO - - MANUAL - - supply_fan_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - exhaust_fan_run_mode: - - AUTO - - MANUAL - - # Addition of telemetry for outside sensors - - outside_air_co2_concentration_sensor: - flexible_min: 0.00005 - flexible_max: 0.005 - - #Addition of new fields for Tanks## - - level_status: - - LOW - - MEDIUM - - HIGH - - line_pressure_sensor: - flexible_min: 0.0 - flexible_max: 689476.0 - - return_air_isolation_damper_status: - - OPEN - - CLOSED - - return_air_isolation_damper_command: - - OPEN - - CLOSED - - discharge_air_isolation_damper_status: - - OPEN - - CLOSED - - discharge_air_isolation_damper_command: - - OPEN - - CLOSED - - supply_fan_speed_mode: - - BYPASS - - VFD - - supply_fan_voltage_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - humidifier_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - heater_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - supply_fan_power_status: - - ON - - OFF - - discharge_fan_run_mode: - - AUTO - - MANUAL - - exhaust_fan_speed_mode: - - BYPASS - - VFD - - ## New fields for EM## - - electricalgrid_energy_accumulator: - fixed_min: 0.0 - flexible_max: 4000000.0 - - generator_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - generator_energy_accumulator: - fixed_min: 0.0 - flexible_max: 4000000.0 - - electricalgrid_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - ## New fields for fans## - - discharge_fan_energy_accumulator: - fixed_min: 0.0 - flexible_max: 100000.0 - - supply_fan_energy_accumulator: - fixed_min: 0.0 - flexible_max: 100000.0 - - compressor_run_time_accumulator: - fixed_min: 0.0 - flexible_max: 1.25 - - total_failed_lamp_counter: - fixed_min: 0.0 - flexible_max: 10000000.0 - - total_failed_wireless_device_counter: - fixed_min: 0.0 - flexible_max: 10000000.0 - - total_failed_communication_counter: - fixed_min: 0.0 - flexible_max: 10000000.0 - - ## New field for AHU - - mixed_air_damper_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - mixed_air_damper_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - ## New fields for seismic detector - - seismic_alarm: - - ACTIVE - - INACTIVE - - - lighting_color_cie_xvalue_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - lighting_color_cie_yvalue_sensor: - flexible_min: 0.0 - flexible_max: 500.0 - - lighting_color_hsl_saturation_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - lighting_color_hsl_hue_angle_sensor: - fixed_min: 0.0 - fixed_max: 360.0 - - lighting_color_cie_xvalue_setpoint: - flexible_min: 0.0 - flexible_max: 500.0 - - lighting_color_cie_yvalue_setpoint: - flexible_min: 0.0 - flexible_max: 500.0 - - lighting_color_hsl_saturation_percentage_setpoint: - fixed_min: 0.0 - fixed_max: 100.0 - - lighting_color_hsl_hue_angle_setpoint: - fixed_min: 0.0 - fixed_max: 360.0 - - luminaire_alarm: - - ACTIVE - - INACTIVE - - group_alarm: - - ACTIVE - - INACTIVE - - group_mode: - - DIMMING - - CONSTANT_LIGHT_CONTROL - - AUTO - - SCENE_CONTROL - - high_limit_illuminance_setpoint: - flexible_min: 0.0 - flexible_max: 5000.0 - - low_limit_illuminance_setpoint: - flexible_min: 0.0 - flexible_max: 5000.0 - - brightness_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - heating_output_percentage_command: - fixed_min: 0.0 - fixed_max: 100.0 - - dimmer_run_status: - - ON - - OFF - - wind_alarm: - - ACTIVE - - INACTIVE - - rain_alarm: - - ACTIVE - - INACTIVE - - outside_illuminance_sensor: - flexible_min: 0.0 - flexible_max: 5000.0 - - shade_orientation_specification: - - NORTH - - SOUTH - - EAST - - WEST - - shade_mode: - - MANUAL - - AUTO - - DAY_NIGHT - - THERMAL - - WINDOW_OPEN - - ## New fields for RO water system - - water_totaldissolvedsolids_concentration_sensor: - flexible_min: 0.0 - flexible_max: 0.001 - - ## New field for VAV - - high_limit_zone_air_co2_concentration_setpoint: - flexible_min: 0.00005 - flexible_max: 0.005 - - low_limit_zone_air_co2_concentration_setpoint: - flexible_min: 0.00005 - flexible_max: 0.005 - - ## New field for SDC - - shade_extent_percentage_sensor: - fixed_min: 0.0 - fixed_max: 100.0 - - ## New alarms added 1/25/23 - - failed_circulation_pump_alarm: - - ACTIVE - - INACTIVE - - failed_discharge_air_temperature_alarm: - - ACTIVE - - INACTIVE - - failed_exhaust_air_temperature_alarm: - - ACTIVE - - INACTIVE - - failed_heating_water_valve_alarm: - - ACTIVE - - INACTIVE - - failed_isolation_valve_alarm: - - ACTIVE - - INACTIVE - - failed_mixed_air_temperature_alarm: - - ACTIVE - - INACTIVE - - failed_return_air_isolation_damper_alarm: - - ACTIVE - - INACTIVE - - failed_smoke_detection_alarm: - - ACTIVE - - INACTIVE - - failed_supply_air_isolation_damper_alarm: - - ACTIVE - - INACTIVE - - failed_zone_air_temperature_alarm: - - ACTIVE - - INACTIVE - - high_differential_pressure_alarm: - - ACTIVE - - INACTIVE - - high_supply_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - high_supply_air_temperature_alarm: - - ACTIVE - - INACTIVE - - high_supply_water_temperature_alarm: - - ACTIVE - - INACTIVE - - high_return_water_temperature_alarm: - - ACTIVE - - INACTIVE - - high_zone_air_co2_concentration_alarm: - - ACTIVE - - INACTIVE - - high_zone_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - high_zone_air_temperature_alarm: - - ACTIVE - - INACTIVE - - local_alarm: - - ACTIVE - - INACTIVE - - local_override_alarm: - - ACTIVE - - INACTIVE - - local_override_isolation_valve_alarm: - - ACTIVE - - INACTIVE - - high_building_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - low_building_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - low_supply_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - low_supply_air_temperature_alarm: - - ACTIVE - - INACTIVE - - low_supply_water_temperature_alarm: - - ACTIVE - - INACTIVE - - low_return_water_temperature_alarm: - - ACTIVE - - INACTIVE - - low_zone_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - low_zone_air_temperature_alarm: - - ACTIVE - - INACTIVE - - failed_communication_alarm: - - ACTIVE - - INACTIVE - - low_flowrate_alarm: - - ACTIVE - - INACTIVE - - high_zone_air_co_concentration_alarm: - - ACTIVE - - INACTIVE - - failed_discharge_air_isolation_damper_alarm: - - ACTIVE - - INACTIVE - - high_speed_command: - - ON - - OFF - - low_speed_command: - - ON - - OFF - - high_speed_status: - - ON - - OFF - - low_speed_status: - - ON - - OFF - - - high_water_temperature_alarm: - - ACTIVE - - INACTIVE - - - ultraviolet_irradiance_sensor: - fixed_min: 0.0 - flexible_max: 2000.0 - - - purge_command: - - ON - - OFF - - - high_discharge_air_temperature_alarm: - - ACTIVE - - INACTIVE - - - low_discharge_air_temperature_alarm: - - ACTIVE - - INACTIVE - - - high_discharge_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - - low_discharge_air_static_pressure_alarm: - - ACTIVE - - INACTIVE - - - soundpressurelevel_sensor: - fixed_min: -60 - flexible_max: 200 - - - zone_occupant_counter: - fixed_min: 0 - flexible_max: 1000 - - - zone_air_voc_aqi_sensor: - fixed_min: 0 - flexible_max: 500 - - - zone_air_smoke_aqi_sensor: - fixed_min: 0 - flexible_max: 80 - - - tamper_status: - - ON - - OFF +- building_air_static_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 249.080024 +- building_air_static_pressure_setpoint: + flexible_min: -249.080024 + flexible_max: 249.080024 +- bypass_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- chilled_supply_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- chilled_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- chilled_supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- chilled_water_bypass_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_water_bypass_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_water_differential_pressure_sensor: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- chilled_water_differential_pressure_setpoint: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- chilled_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_water_isolation_valve_command: + - OPEN + - CLOSED +- chilled_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- circulation_pump_run_status: + - ON + - OFF +- compressor_run_command: + - ON + - OFF + - UNKNOWN +- compressor_run_status: + - ON + - OFF + - UNKNOWN +- compressor_speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- refrigerant_condenser_saturation_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- condensing_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- condensing_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- condensing_supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- condensing_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- water_linearvelocity_sensor: + fixed_min: 0.0 + flexible_max: 5.08001016 +- cooling_output_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- current_sensor: + fixed_min: 0.0 + flexible_max: 200.0 +- torque_sensor: + fixed_min: 0.0 + flexible_max: 678.0 +- differential_pressure_sensor: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- differential_pressure_setpoint: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- discharge_air_cooling_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 310.9259259 +- discharge_air_heating_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- discharge_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- discharge_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- discharge_fan_current_sensor: + fixed_min: 0.0 + flexible_max: 100.0 +- discharge_fan_run_command: + - ON + - OFF + - AUTO + - UNKNOWN +- discharge_fan_run_status: + - ON + - OFF + - AUTO + - UNKNOWN +- discharge_fan_speed_mode: + - AUTO + - LOW + - MEDIUM + - HIGH + - OFF + - VFD +- discharge_fan_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- dryer_run_status: + - ON + - OFF +- economizer_mode: + - ON + - OFF + - AUTO +- evaporator_pressure_sensor: + flexible_min: 0.0 + flexible_max: 2068427.367 +- refrigerant_evaporator_saturation_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- exhaust_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- exhaust_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- exhaust_fan_current_sensor: + fixed_min: 0.0 + flexible_max: 100.0 +- exhaust_fan_power_sensor: + flexible_min: 0.0 + flexible_max: 100000.0 +- exhaust_fan_run_command: + - ON + - OFF +- exhaust_fan_run_status: + - ON + - OFF + - UNKNOWN +- exhaust_fan_speed_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- exhaust_fan_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- exhaust_fan_speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- fan_run_status: + - ON + - OFF +- fan_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- heater_run_command: + - ON + - OFF +- heating_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- inlet_guidevane_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- isolation_damper_status: + - OPEN + - CLOSED +- isolation_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- line_current_sensor: + fixed_min: 0.0 + flexible_max: 10000.0 +- line_powerfactor_sensor: + fixed_min: 0.0 + fixed_max: 1.0 +- loop_chilled_water_differential_pressure_sensor: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- loop_differential_pressure_sensor: + flexible_min: -68947.6 + flexible_max: 344738.0 +- min_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 0.315451 +- min_chilled_water_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 0.315451 +- ventilation_outside_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- ventilation_outside_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 47.19474432 +- ventilation_outside_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 47.19474432 +- mixed_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- outside_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- outside_air_specificenthalpy_sensor: + flexible_min: 11630.0 + flexible_max: 81410.0 +- outside_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 47.19474432 +- outside_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 47.19474432 +- outside_air_pressure_sensor: + flexible_min: 500.0 + flexible_max: 200000.0 +- outside_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- outside_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- outside_air_wetbulb_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- wind_linearvelocity_sensor: + flexible_min: 0.0 + flexible_max: 100.0 +- wind_direction_angle_sensor: + fixed_min: 0.0 + fixed_max: 360.0 +- outside_air_rain_level_sensor: + flexible_min: 0.0 + flexible_max: 0.00005 +- outside_air_voc_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.005 +- power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- return_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- return_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- return_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- return_fan_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- return_fan_power_sensor: + flexible_min: 0.0 + flexible_max: 100000.0 +- return_fan_torque_sensor: + fixed_min: 0.0 + flexible_max: 678.0 +- return_fan_run_command: + - ON + - OFF +- return_fan_run_status: + - ON + - OFF + - UNKNOWN +- return_fan_speed_frequency_command: + flexible_min: -0.5 + flexible_max: 65.0 +- return_fan_speed_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- return_fan_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- return_fan_speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- reversing_valve_command: + - AUTO + - CLOSED + - OPEN + - UNKNOWN +- run_command: + - ON + - OFF +- run_status: + - ON + - OFF + - STANDBY +- speed_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 94.38948864 +- supply_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 +- supply_air_static_pressure_sensor: + flexible_min: -124.540012 + flexible_max: 2490.80024 +- supply_air_static_pressure_setpoint: + flexible_min: -124.540012 + flexible_max: 2490.80024 +- supply_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- supply_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- supply_fan_current_sensor: + fixed_min: 0.0 + flexible_max: 100.0 +- supply_fan_power_sensor: + flexible_min: 0.0 + flexible_max: 100000.0 +- supply_fan_torque_sensor: + fixed_min: 0.0 + flexible_max: 678.0 +- supply_fan_run_command: + - ON + - OFF +- supply_fan_run_status: + - ON + - OFF + - UNKNOWN +- supply_fan_speed_frequency_command: + flexible_min: -0.5 + flexible_max: 65.0 +- supply_fan_speed_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- supply_fan_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_fan_speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- cooling_request_count: + fixed_min: 0.0 + flexible_max: 500.0 +- heating_request_count: + fixed_min: 0.0 + flexible_max: 250.0 +- pressurization_request_count: + fixed_min: 0.0 + flexible_max: 500.0 +- zone_air_co2_concentration_sensor: + flexible_min: 0.00005 + flexible_max: 0.005 +- zone_air_co2_concentration_setpoint: + flexible_min: 0.00005 + flexible_max: 0.005 +- max_zone_air_co2_concentration_sensor: + flexible_min: 0.00005 + flexible_max: 0.005 +- average_zone_air_co2_concentration_sensor: + flexible_min: 0.00005 + flexible_max: 0.005 +- zone_air_co_concentration_setpoint: + flexible_min: 0.00035 + flexible_max: 0.0015 +- zone_air_cooling_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- zone_air_heating_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- zone_air_refrigerant_concentration_sensor: + flexible_min: 0.00035 + flexible_max: 0.0015 +- zone_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_deadband_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- zone_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- outside_air_co_concentration_sensor: + flexible_min: 0.00035 + flexible_max: 0.0015 +- outside_air_so2_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.002 +- outside_air_no2_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- outside_air_no_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- outside_air_h2s_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- outside_air_ozone_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- outside_air_pm2pt5_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- outside_air_pm10pt0_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- outside_air_pm1pt0_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- outside_air_no_density_sensor: + flexible_min: 0.0 + flexible_max: 0.0002 +- outside_air_no2_density_sensor: + flexible_min: 0.0 + flexible_max: 0.0002 +- outside_air_so2_density_sensor: + flexible_min: 0.0 + flexible_max: 0.002 + +# Additional fields added to cover first hundred buildings +- bypass_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- bypass_return_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- bypass_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_water_isolation_valve_status: + - OPEN + - CLOSED +- circulation_changeover_isolation_valve_status: + - OPEN + - CLOSED +- circulation_pump_run_command: + - ON + - OFF +- cogeneration_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- cogeneration_return_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- cogeneration_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- cold_aisle_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- cooling_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- cooling_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 4.719474432 +- cooling_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 4.719474432 +- dehumidification_run_command: + - ON + - OFF +- dehumidification_run_status: + - ON + - OFF +- discharge_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- discharge_fan_speed_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- dishwasher_run_status: + - ON + - OFF +- east_illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 +- evaporative_cooler_run_command: + - ON + - OFF +- exhaust_air_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- exhaust_air_static_pressure_sensor: + flexible_min: -996.320096 + flexible_max: 996.320096 +- exhaust_air_static_pressure_setpoint: + flexible_min: -996.320096 + flexible_max: 996.320096 +- filter_differential_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 2490.80024 +- discharge_air_filter_differential_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 2490.80024 +- exhaust_air_filter_differential_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 2490.80024 +- flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 0.315451 +- flue_gas_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 533.1481481 +- heating_stage_run_count: + fixed_min: 0.0 + flexible_max: 10.0 +- heating_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 23.59737216 +- heating_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 23.59737216 +- heating_cooling_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_water_valve_status: + - OPEN + - CLOSED +- high_discharge_fan_speed_command: + - ON + - OFF +- hot_aisle_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- humidification_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- humidification_run_command: + - ON + - OFF +- humidification_run_status: + - ON + - OFF +- discharge_air_damper_command: + - OPEN + - CLOSED +- isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- leaving_heating_coil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- low_discharge_fan_speed_command: + - ON + - OFF +- makeup_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- makeup_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- medium_discharge_fan_speed_command: + - ON + - OFF +- min_outside_air_damper_command: + - OPEN + - CLOSED +- min_outside_air_damper_status: + - OPEN + - CLOSED +- mixed_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- outside_air_damper_command: + - OPEN + - CLOSED +- outside_air_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- outside_air_dewpoint_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 310.9259259 +- primary_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- production_differential_pressure_sensor: + flexible_min: -3450.0 + flexible_max: 344737.8945 +- return_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- return_air_dehumidification_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- return_air_humidification_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- return_air_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- return_water_valve_command: + - OPEN + - CLOSED +- return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- return_water_valve_status: + - OPEN + - CLOSED +- return_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- secondary_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- secondary_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- shade_extent_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- shade_tilt_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- southeast_illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 +- southwest_illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 +- speed_frequency_command: + flexible_min: -0.5 + flexible_max: 65.0 +- spray_pump_run_command: + - ON + - OFF +- spray_pump_run_status: + - ON + - OFF +- supply_air_cooling_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- supply_air_heating_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- supply_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_water_valve_command: + - OPEN + - CLOSED +- supply_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_water_valve_status: + - OPEN + - CLOSED +- west_illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 +- zone_air_co_concentration_sensor: + flexible_min: 0.00035 + flexible_max: 0.0015 +- zone_air_dehumidification_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_humidification_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 + +## added on 10/13/2018 +- condensing_water_isolation_valve_command: + - OPEN + - CLOSED +- condensing_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- condensing_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 + +## Added on 10/25/2018 +- compressor_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- compressor_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- compressor_lost_power_alarm: + - ACTIVE + - INACTIVE +- east_wind_linearvelocity_sensor: + flexible_min: 0.0 + flexible_max: 44.704 +- west_wind_linearvelocity_sensor: + flexible_min: 0.0 + flexible_max: 44.704 +- condenser_pressure_sensor: + flexible_min: 68947.5789 + flexible_max: 2068427.367 +- chilled_water_valve_command: + - OPEN + - CLOSED +- heating_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +## Added on 10/30 +- thermal_power_sensor: + flexible_min: 0.0 + flexible_max: 3517000.0 +- discharge_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 94.38948864 +- exercise_mode: + - ON + - OFF + +# Alarms updated to convert the alarm subfield to a point type from measurement descriptor. + +- run_mode: + - COMMISSIONING + - FLUSHING + - HEATING + - COOLING + - NEUTRAL + - OFF + - AUTO + - MANUAL + - DEHUMIDIFY + - FAN_ONLY +- dial_resistance_sensor: + flexible_min: 0.0 + flexible_max: 10000.0 +- zone_occupancy_status: + - OCCUPIED + - UNKNOWN + - UNOCCUPIED + - INACTIVE + +# INACTIVE indicates the device is being overridden to not run, irrespective of occupancy status. + +## Added on 12/12 +- leaving_cooling_coil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- leaving_cooling_coil_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- heating_water_valve_command: + - OPEN + - CLOSED +- heating_water_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_water_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- exhaust_air_damper_command: + - OPEN + - CLOSED + +## Added on 2019/02/19 +- heating_stage_run_command: + - ON + - OFF +- return_air_cooling_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- return_air_heating_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- condensing_fan_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +## Added on 2019/02/27 +- boost_fan_run_command: + - ON + - OFF +- boost_fan_run_status: + - ON + - OFF +- chilled_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- compressor_speed_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- condensing_water_isolation_valve_status: + - OPEN + - CLOSED +- east_building_air_static_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 249.080024 +- east_exhaust_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- exhaust_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 94.38948864 +- exhaust_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 23.59737216 +- exhaust_air_differential_flowrate_sensor: + flexible_min: 0.0 + flexible_max: 23.59737216 +- exhaust_air_differential_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 23.59737216 +- fan_speed_mode: + - OFF + - LOW + - MEDIUM + - HIGH + - AUTO + - MANUAL +- heat_exchange_isolation_valve_command: + - OPEN + - CLOSED +- heat_exchange_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- humidifier_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- mixing_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- preheating_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- return_air_damper_command: + - OPEN + - CLOSED +- return_air_damper_status: + - OPEN + - CLOSED +- return_air_flowrate_sensor: + flexible_min: -0.002359737216 + flexible_max: 94.38948864 +- return_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 +- return_air_static_pressure_sensor: + flexible_min: -996.320096 + flexible_max: 996.320096 +- return_air_static_pressure_setpoint: + flexible_min: -996.320096 + flexible_max: 996.320096 +- supply_air_dehumidification_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_air_humidification_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_air_isolation_damper_command: + - OPEN + - CLOSED +- west_building_air_static_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 249.080024 +- west_exhaust_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_static_pressure_sensor: + flexible_min: -249.080024 + flexible_max: 249.080024 +- zone_air_static_pressure_setpoint: + flexible_min: -124.540012 + flexible_max: 124.540012 +- zone_air_voc_concentration_sensor: + flexible_min: 0.0001 + flexible_max: 0.0015 +- zone_air_voc_concentration_setpoint: + flexible_min: 0.0001 + flexible_max: 0.0015 +- return_air_voc_concentration_sensor: + flexible_min: 0.0001 + flexible_max: 0.0015 +- return_air_voc_concentration_setpoint: + flexible_min: 0.0001 + flexible_max: 0.0015 + +## Added on 2019/03/12 +- cooling_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- primary_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- supply_air_isolation_damper_status: + - OPEN + - CLOSED + +## Added on 2019/03/19 +- cooling_thermal_power_sensor: + flexible_min: 0.0 + flexible_max: 3517000.0 +- cooling_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- exhaust_air_damper_status: + - OPEN + - CLOSED +- east_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- west_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- east_differential_pressure_sensor: + flexible_min: -3447.378945 + flexible_max: 344737.8945 +- west_differential_pressure_sensor: + flexible_min: -3447.378945 + flexible_max: 344737.8945 +- east_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- west_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- process_chilled_return_water_temperature_sensor: + flexible_min: 274.8148148 + flexible_max: 299.8148148 +- process_chilled_supply_water_temperature_sensor: + flexible_min: 274.8148148 + flexible_max: 299.8148148 +- leaving_air_preheating_coil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 310.9259259 + +## Added on 2019/03/20 +- cooling_stage_run_count: + fixed_min: 0.0 + flexible_max: 500.0 +- min_return_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- process_cooling_thermal_power_sensor: + flexible_min: 0.0 + flexible_max: 3517000.0 +- process_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- process_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- process_supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- process_water_differential_pressure_sensor: + flexible_min: -3447.378945 + flexible_max: 344737.8945 +- process_water_differential_pressure_setpoint: + flexible_min: -3447.378945 + flexible_max: 344737.8945 +- process_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- process_water_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 0.315451 +- process_water_isolation_valve_command: + - OPEN + - CLOSED +- process_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +## Added on 2019/03/26 +- zone_air_refrigerant_concentration_setpoint: + flexible_min: 0.00035 + flexible_max: 0.0015 + +# Added on 2019/06/03 +- apparent_power_sensor: + fixed_min: 0.0 + flexible_max: 10000000.0 +- energy_accumulator: + fixed_min: 0.0 + flexible_max: 10000000.0 +- average_line_current_sensor: + fixed_min: 0.0 + flexible_max: 2000.0 +- average_line_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- average_inter_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase1_line_current_sensor: + fixed_min: 0.0 + flexible_max: 2000.0 +- phase1_neutral_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase1_phase2_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase1_phase3_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase1_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- phase1_powerfactor_sensor: + flexible_min: -1.5 + flexible_max: 1.5 +- phase2_line_current_sensor: + fixed_min: 0.0 + flexible_max: 2000.0 +- phase2_neutral_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase2_phase3_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase2_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- phase2_powerfactor_sensor: + flexible_min: -1.5 + flexible_max: 1.5 +- phase3_line_current_sensor: + fixed_min: 0.0 + flexible_max: 2000.0 +- phase3_neutral_line_voltage_sensor: + flexible_min: 0.0 + flexible_max: 20000.0 +- phase3_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- phase3_powerfactor_sensor: + flexible_min: -1.5 + flexible_max: 1.5 +- powerfactor_sensor: + flexible_min: -1.5 + flexible_max: 100.0 +- reactive_power_sensor: + flexible_min: -30000000.0 + flexible_max: 30000000.0 +- phase1_reactive_power_sensor: + flexible_min: -30000.0 + flexible_max: 30000.0 +- phase2_reactive_power_sensor: + flexible_min: -30000.0 + flexible_max: 30000.0 +- phase3_reactive_power_sensor: + flexible_min: -30000.0 + flexible_max: 30000.0 + +# Added on 2019/06/27 for Enlighted +- dimmer_percentage_command: # Should be adjusted to brightness_percentage_command + fixed_min: 0.0 + fixed_max: 100.0 + +# Added on 2019/08/13 primarily for GVC +- calendar_sync_status: + - ACCESS_FAILED + - CALENDAR_STARTUP + - CALENDAR_SUCCESS + - SUBSCRIPTION_FAILED + - WAITING_FOR_RESPONSE +- conference_id_hash_label +- conference_id_match_status: + - DOES_NOT_MATCH + - MATCHES +- conference_call_status: + - ACTIVE + - INACTIVE +- matched_event_id_label +- message_counter: + fixed_min: 0.0 + flexible_max: 10000000.0 +- next_event_end_timestamp +- next_event_start_timestamp +- ongoing_event_end_timestamp +- ongoing_event_start_timestamp +- ongoing_event_id_label +- room_calendar_email_label +- user_occupancy_override_status: + - DISABLED + - ENABLED + +# Added on 2019/09/12 for Enlighted: generic light level sensor +- illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 + +- condensing_water_bypass_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- condensing_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +- heater_run_status: # Added 10/2/2019 + - ON + - OFF +- discharge_fan_power_sensor: + flexible_min: 0.0 + flexible_max: 100000.0 +- outside_air_damper_status: + - OPEN + - CLOSED +- humidification_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- discharge_fan_speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- discharge_air_heating_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- discharge_fan_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- discharge_fan_torque_sensor: + fixed_min: 0.0 + flexible_max: 678.0 +- supply_air_damper_command: + - OPEN + - CLOSED +- supply_air_damper_status: + - OPEN + - CLOSED + +# Added 11/6/2019 +- low_limit_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 0.315451 +- return_water_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- return_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +# Added 11/12/2019 + +- gas_flowrate_sensor: + fixed_min: 0.0 + flexible_max: 0.003932896 +- gas_volume_accumulator: + fixed_min: 0.0 + flexible_max: 0.003932896 +- water_volume_accumulator: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- gas_temperature_sensor: + flexible_min: 283.1481481 + flexible_max: 533.1481481 +- volume_accumulator: + flexible_min: 0 + flexible_max: 318000 + +# Added 12/17/2019 +- cooling_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- cooling_water_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- cooling_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- heating_water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.0315451 +- zone_air_offset_temperature_setpoint: + flexible_min: 254.8148148 + flexible_max: 283.1481481 + +# Added 1/16/2020 +- discharge_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +# Added 2/10/2020 +- supply_water_isolation_valve_command: + - OPEN + - CLOSED +- supply_water_isolation_valve_status: + - OPEN + - CLOSED +- return_water_isolation_valve_command: + - OPEN + - CLOSED +- return_water_isolation_valve_status: + - OPEN + - CLOSED +- chilled_return_water_isolation_valve_command: + - OPEN + - CLOSED +- condensing_return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- condensing_return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_supply_water_isolation_valve_command: + - OPEN + - CLOSED +- chilled_return_water_isolation_valve_status: + - OPEN + - CLOSED + +# Added 2/11/2020 +- discharge_air_static_pressure_sensor: + flexible_min: -124.540012 + flexible_max: 996.320096 + +# Added 2/12/2020 +- heat_exchange_supply_water_isolation_valve_command: + - OPEN + - CLOSED +- heat_exchange_return_water_isolation_valve_command: + - OPEN + - CLOSED +- heat_exchange_supply_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heat_exchange_return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heat_exchange_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- heat_exchange_return_water_isolation_valve_status: + - OPEN + - CLOSED +- heat_exchange_supply_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- heat_exchange_return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- condensing_return_water_isolation_valve_command: + - OPEN + - CLOSED +- chilled_return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +# Added 2/24/2020 +- chilled_supply_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_supply_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- chilled_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- condensing_return_water_isolation_valve_status: + - OPEN + - CLOSED +- condensing_supply_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- condensing_supply_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- condensing_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- condensing_supply_water_isolation_valve_command: + - OPEN + - CLOSED + +# Added 4/12/20 +- supply_air_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 + +# Added 6/4/20 +- ventilation_request_count: + fixed_min: 0.0 + flexible_max: 500.0 +- refrigerant_evaporator_pressure_sensor: + flexible_min: 0.0 + flexible_max: 2068427.367 +- refrigerant_condenser_pressure_sensor: + flexible_min: 0.0 + flexible_max: 2068427.367 +- refrigerant_suction_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- refrigerant_discharge_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- low_limit_outside_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- sweeper_pump_run_status: + - ON + - OFF +- sweeper_pump_run_command: + - ON + - OFF +- evaporative_cooler_run_status: + - ON + - OFF +- drain_pump_run_status: + - ON + - OFF +- failed_drain_pump_alarm: + - ACTIVE + - INACTIVE +- water_low_level_status: + - ACTIVE + - INACTIVE +- water_high_level_status: + - ACTIVE + - INACTIVE +- input_motor_power_status: + - ON + - OFF + +# Additional functionality for alarms and status points. +# For alarms, they will end in `alarm` and be two-state. +# Status fields must be distinguished from alarms in that status is an objective qualitative state (flowing/not) whereas alarms are judgmental interpretations of such statuses to draww a conclusion about function (alarm/normal) + +- average_supply_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- average_supply_air_static_pressure_sensor: + flexible_min: -124.540012 + flexible_max: 2490.80024 +- control_mode: + - AUTO + - MANUAL + - OFF + - HEATING + - COOLING + - DEHUMIDIFY + - FAN_ONLY +- cooling_thermal_energy_accumulator: + fixed_min: 0.0 + flexible_max: 3517000.0 +- particle_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- high_limit_supply_air_cooling_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 +- high_limit_supply_air_heating_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 +- low_limit_supply_air_ventilation_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 +- low_limit_supply_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 +- high_limit_supply_air_flowrate_setpoint: # used when the device doesn't necessarily provide a cooling max flow + flexible_min: 0.0 + flexible_max: 94.38948864 +- schedule_run_command: + - ON + - OFF +- supply_air_dewpoint_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- supply_air_dewpoint_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- ultraviolet_lamp_run_command: + - ON + - OFF +- ultraviolet_lamp_run_status: + - ON + - OFF +- water_leak_cable_distance_sensor: + fixed_min: 0.0 + flexible_max: 304.7999902 +- discharge_air_linearvelocity_setpoint: + fixed_min: 0.0 + flexible_max: 25.4000508 + +# New usage of status as an override for the measurement. +- chilled_water_flowrate_status: + - PRESENT + - ABSENT +- condensing_water_flowrate_status: + - PRESENT + - ABSENT +- discharge_air_static_pressure_status: + - PRESENT + - ABSENT +- filter_differential_pressure_status: + - PRESENT + - ABSENT +- electrostatic_filter_run_status: + - ON + - OFF +- electrostatic_filter_alarm: + - ACTIVE + - INACTIVE +- high_level_status: + - PRESENT + - ABSENT +- low_level_status: + - PRESENT + - ABSENT +- power_status: + - PRESENT + - ABSENT + +# New alarms using alarm as a point type, and existing alarms moved here +# TODO (tsodorff): change these to ALARM/NORMAL after determining how this can be done safely to existing translations. +- fabric_protection_alarm: + - ACTIVE + - INACTIVE +- failed_alarm: + - ACTIVE + - INACTIVE +- filter_alarm: + - ACTIVE + - INACTIVE +- discharge_air_filter_alarm: + - ACTIVE + - INACTIVE +- exhaust_air_filter_alarm: + - ACTIVE + - INACTIVE +- master_alarm: + - ACTIVE + - INACTIVE +- failed_supply_fan_alarm: + - ACTIVE + - INACTIVE +- smoke_alarm: + - ACTIVE + - INACTIVE +- water_leak_alarm: + - ACTIVE + - INACTIVE +- low_differential_pressure_alarm: + - ACTIVE + - INACTIVE +- lost_power_alarm: + - ACTIVE + - INACTIVE +- overload_alarm: + - ACTIVE + - INACTIVE +- overload_compressor_alarm: + - ACTIVE + - INACTIVE +- overload_discharge_fan_alarm: + - ACTIVE + - INACTIVE +- high_pressure_status: + - ACTIVE + - INACTIVE +- low_pressure_status: + - ACTIVE + - INACTIVE +- refrigerant_high_pressure_status: + - ACTIVE + - INACTIVE +- refrigerant_low_pressure_status: + - ACTIVE + - INACTIVE +- failed_humidifier_alarm: + - ACTIVE + - INACTIVE +- failed_heat_exchange_alarm: + - ACTIVE + - INACTIVE +- failed_compressor_alarm: + - ACTIVE + - INACTIVE + +# New fields for lighting and fire systems. +- motion_status: + - PRESENT + - ABSENT +- battery_charge_status: + - CHARGING + - DISCHARGING + - STANDBY +- battery_charge_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- max_battery_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- max_battery_voltage_sensor: + flexible_min: 0.0 + flexible_max: 15.0 +- min_battery_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- min_battery_voltage_sensor: + flexible_min: 0.0 + flexible_max: 15.0 +- failed_battery_alarm: + - ACTIVE + - INACTIVE +- brightness_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +# New fields for emergency systems +- emergency_alarm: + - ACTIVE + - INACTIVE +- broken_cable_alarm: + - ACTIVE + - INACTIVE +- gas_leak_detection_alarm: + - ACTIVE + - INACTIVE +- ammonia_leak_detection_alarm: + - ACTIVE + - INACTIVE +- water_leak_detection_alarm: + - ACTIVE + - INACTIVE +- fire_alarm: + - ACTIVE + - INACTIVE +- supply_water_volume_accumulator: + fixed_min: -0.000315451 + flexible_max: 0.315451 +- valve_command: + - OPEN + - CLOSED +- valve_status: + - OPEN + - CLOSED +- emergency_release_status: + - ACTIVE + - INACTIVE +- position_status: + - OPEN + - CLOSED +- condensing_water_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- entering_cooling_coil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 + +# We should not use this... represents scavenged outside air from near some heat pumps... +- mixed_outside_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- discharge_fan_lost_power_alarm: + - ACTIVE + - INACTIVE +- low_discharge_air_flowrate_alarm: + - ACTIVE + - INACTIVE +- frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- failed_discharge_fan_alarm: + - ACTIVE + - INACTIVE +- discharge_air_linearvelocity_sensor: + fixed_min: 0.0 + flexible_max: 25.4000508 +- condensing_water_bypass_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- scene_index_command: + fixed_min: 0.0 + flexible_max: 100.0 + +# This is a change +- line_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- phase1_apparent_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- phase2_apparent_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- phase3_apparent_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 + +# Added for Automatic transfer switch +- source1_phase1_phase2_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- source1_phase2_phase3_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- source1_phase3_phase1_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- source1_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- source2_phase1_phase2_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- source2_phase2_phase3_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- source2_phase3_phase1_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- source2_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- master_mode: + - SOURCEA + - NOSOURCE + - REMOTE + - MANUAL +- source1_lost_power_alarm: + - ACTIVE + - INACTIVE +- source2_lost_power_alarm: + - ACTIVE + - INACTIVE +- generator_status: + - ON + - OFF +- source1_phase1_phase2_over_voltage_status: + - PRESENT + - ABSENT +- source1_phase2_phase3_over_voltage_status: + - PRESENT + - ABSENT +- source1_phase3_phase1_over_voltage_status: + - PRESENT + - ABSENT +- source1_over_voltage_status: + - PRESENT + - ABSENT +- source2_phase1_phase2_over_voltage_status: + - PRESENT + - ABSENT +- source2_phase2_phase3_over_voltage_status: + - PRESENT + - ABSENT +- source2_phase3_phase1_over_voltage_status: + - PRESENT + - ABSENT +- source2_over_voltage_status: + - ACTIVE + - INACTIVE +- switch_position_mode: + - POSITIONA + - POSITIONB + - POSITIONC +- zone_air_voc_percentage_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_voc_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_unoccupied_heating_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- zone_air_occupied_heating_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- zone_air_unoccupied_deadband_temperature_setpoint: + flexible_min: 255.372 + flexible_max: 272.039 +- zone_air_occupied_deadband_temperature_setpoint: + flexible_min: 255.372 + flexible_max: 272.039 +- mixed_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- mixed_air_dewpoint_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- supply_air_isolation_damper_closed_status: + - OPEN + - CLOSED +- supply_air_isolation_damper_open_status: + - OPEN + - CLOSED +- control_status: + - REMOTE + - LOCAL +- zone_scene_command: + - ACTIVE + - INACTIVE +- scene_command: + - ACTIVE + - INACTIVE +- cooling_run_status: + - ON + - OFF +- high_return_air_temperature_alarm: + - ACTIVE + - INACTIVE +- low_return_air_temperature_alarm: + - ACTIVE + - INACTIVE +- high_return_air_relative_humidity_alarm: + - ACTIVE + - INACTIVE +- low_return_air_relative_humidity_alarm: + - ACTIVE + - INACTIVE +- failed_chilled_water_valve_alarm: + - ACTIVE + - INACTIVE +- discharge_fan_speed_frequency_command: + flexible_min: -0.5 + flexible_max: 65.0 +- ultraviolet_lamp_run_mode: + - AUTO + - MANUAL +- discharge_air_flowrate_status: + - ON + - OFF +- damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_fan_lost_power_alarm: + - ACTIVE + - INACTIVE +- panel_alarm: + - ACTIVE + - INACTIVE +- supply_air_flowrate_status: + - ON + - OFF +- return_air_co2_concentration_sensor: + flexible_min: 0.00005 + flexible_max: 0.005 +- return_air_co2_concentration_setpoint: + flexible_min: 0.00005 + flexible_max: 0.005 + +# Added for Machine Learning Pilot +- supervisor_control_mode: + - ENABLED + - DISABLED +- supervisor_run_command: + - ON + - OFF +- supervisor_supply_air_static_pressure_setpoint: + flexible_min: -124.540012 + flexible_max: 2490.80024 +- supervisor_supply_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- program_supply_air_static_pressure_setpoint: + flexible_min: -124.540012 + flexible_max: 2490.80024 +- program_supply_air_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- supervisor_supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- supervisor_differential_pressure_setpoint: + flexible_min: -6894.75789 + flexible_max: 137895.1578 +- program_supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- program_differential_pressure_setpoint: + flexible_min: -6894.75789 + flexible_max: 137895.1578 +- condensate_water_alarm: + - ACTIVE + - INACTIVE +- supply_water_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_water_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- supply_water_valve_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +- total_request_count: + fixed_min: 0.0 + flexible_max: 500.0 +- zone_conditioning_mode: + - HEATING + - COOLING + - AUTO + - OFF +- water_riser_mode: + - OFF + - HEATING + - COOLING + - AUTO +- average_zone_air_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- heating_supply_water_isolation_valve_command: + - OPEN + - CLOSED +- heating_return_water_isolation_valve_command: + - OPEN + - CLOSED +- heating_return_water_isolation_valve_status: + - OPEN + - CLOSED +- cooling_supply_water_isolation_valve_command: + - OPEN + - CLOSED +- cooling_return_water_isolation_valve_command: + - OPEN + - CLOSED +- heating_supply_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_supply_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- maintenance_alarm: + - ACTIVE + - INACTIVE +- condensate_water_pump_alarm: + - ACTIVE + - INACTIVE +- average_illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 +- illuminance_setpoint: + flexible_min: 0.0 + flexible_max: 5000.0 +- scene_dimmer_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- scene_dimmer_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- low_scene_dimmer_percentage_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- high_scene_dimmer_percentage_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- red_scene_dimmer_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- green_scene_dimmer_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- blue_scene_dimmer_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- dimmer_fade_rate_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- dimmer_fade_time_setpoint: + fixed_min: 0.0 + flexible_max: 30000.0 +- startup_dimmer_percentage_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- dimmer_mode: + - FADING + - RAMPING +- failed_dimmer_alarm: + - ACTIVE + - INACTIVE +- power_command: + - ON + - OFF +- switch_command: + - ON + - OFF +- lighting_switch_status: + - ON + - OFF +- scene_dimmer_command: + - ACTIVE + - INACTIVE +- scene_status: + - ACTIVE + - INACTIVE +- room_occupancy_status: + - OCCUPIED + - UNKNOWN + - UNOCCUPIED + - BYPASS + - STANDBY +- bypass_air_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- circulation_pump_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- circulation_pump_speed_percentage_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- frost_alarm: + - ACTIVE + - INACTIVE +- supply_air_static_pressure_status: + - PRESENT + - ABSENT +- exhaust_air_static_pressure_status: + - PRESENT + - ABSENT +- failed_exhaust_fan_alarm: + - ACTIVE + - INACTIVE +- return_air_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- mixing_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- potable_hot_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_hot_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_hot_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_hot_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- heating_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- heating_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- heating_thermal_power_sensor: + flexible_min: 0.0 + flexible_max: 586142.14 +- heating_thermal_energy_accumulator: + fixed_min: 0.0 + flexible_max: 586142.14 +- max_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 0.315451 +- potable_water_high_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_water_medium_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_water_low_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- heating_supply_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 + +#Discharge air flow control +- discharge_air_flowrate_setpoint: + flexible_min: 0.0 + flexible_max: 94.38948864 + +#Electrical meter fields +- neutral_line_current_sensor: # A measure of current on the neutral line + fixed_min: 0.0 + flexible_max: 10000.0 +- apparent_energy_accumulator: + fixed_min: 0.0 + flexible_max: 10000000.0 + +#Electrical panel fields +- circuitbreaker_status: + - ON + - OFF +- failed_circuitbreaker_alarm: + - ACTIVE + - INACTIVE +- reactive_energy_accumulator: + flexible_min: -30000000.0 + flexible_max: 30000000.0 + +#Lighting controller battery status +- emergency_battery_status: + - ON + - OFF + +# Condensing water monitoring +- condensing_water_differential_pressure_sensor: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- condensing_water_differential_pressure_setpoint: + flexible_min: -34473.78945 + flexible_max: 344737.8945 + +# Heat Wheel Telemetry Fields +- heat_wheel_speed_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- heat_wheel_speed_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- heat_wheel_run_command: + - ON + - OFF +- heat_wheel_run_status: + - ON + - OFF + +# Outside air Isolation Dampers +- outside_air_isolation_damper_command: + - OPEN + - CLOSED +- outside_air_isolation_damper_status: + - OPEN + - CLOSED + +# Exhaust air Isolation Dampers +- exhaust_air_isolation_damper_command: + - OPEN + - CLOSED +- exhaust_air_isolation_damper_status: + - OPEN + - CLOSED + +# Damper status +- damper_status: + - OPEN + - CLOSED +- lighting_percentage_sensor: # For relative ranged illuminance inputs. + fixed_min: 0.0 + fixed_max: 100.0 + +# Air Quality Data +- outside_air_aqi_sensor: + fixed_min: 0.0 + fixed_max: 500.0 +- zone_air_aqi_sensor: + fixed_min: 0.0 + fixed_max: 500.0 +- outside_air_water_vapor_density_sensor: # Equivalent field for absolute humidity + fixed_min: 0.0 + flexible_max: 100.0 +- outside_air_water_vapor_concentration_sensor: # Equivalent field for absolute humidity + flexible_min: 0.0 + flexible_max: 0.016018 +- zone_air_water_vapor_density_sensor: # Equivalent field for absolute humidity + fixed_min: 0.0 + flexible_max: 100.0 +- zone_air_water_vapor_concentration_sensor: # Equivalent field for absolute humidity + flexible_min: 0.0 + flexible_max: 0.016018 +- zone_air_h2s_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- zone_air_so2_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.002 +- zone_air_no2_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- zone_air_formaldehyde_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_ozone_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- zone_air_h2_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.002 +- zone_air_h2s_density_sensor: + fixed_min: 0.0 + flexible_max: 0.0001 +- zone_air_so2_density_sensor: + fixed_min: 0.0 + flexible_max: 0.002 +- zone_air_no2_density_sensor: + fixed_min: 0.0 + flexible_max: 0.0002 +- zone_air_formaldehyde_density_sensor: + fixed_min: 0.0 + flexible_max: 0.000005 +- zone_air_ozone_density_sensor: + fixed_min: 0.0 + flexible_max: 0.00002 + +# First set of PM2.5, PM10, etc. fields. Note that density and concentration +# are differentiated since they return different units of measurement. +- zone_air_pm0pt5_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm1pt0_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm2pt5_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm4pt0_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm10pt0_density_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm0pt5_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm1pt0_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm2pt5_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm4pt0_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm10pt0_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm0pt5_volumetricconcentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm1pt0_volumetricconcentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm2pt5_volumetricconcentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm4pt0_volumetricconcentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 +- zone_air_pm10pt0_volumetricconcentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 + +## New fields for IoT vibration sensor pilot +- fivesecondrolling_max_xaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_max_yaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_max_zaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_min_xaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_min_yaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_min_zaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_rootmeansquare_xaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_rootmeansquare_yaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- fivesecondrolling_rootmeansquare_zaxis_linearacceleration_sensor: + flexible_min: 0.0 + flexible_max: 0.980665 +- local_air_temperature_sensor: + flexible_min: 283.15 + flexible_max: 353.15 + +# New fields for ERV bypass +- bypass_air_damper_command: + - OPEN + - CLOSED +- bypass_air_damper_status: + - OPEN + - CLOSED + +## New fields for IoT Vibration devices +- tenminutefixed_max_xaxis_linearvelocity_sensor: + flexible_min: 0.0 + flexible_max: 0.1 +- tenminutefixed_max_yaxis_linearvelocity_sensor: + flexible_min: 0.0 + flexible_max: 0.1 +- tenminutefixed_max_zaxis_linearvelocity_sensor: + flexible_min: 0.0 + flexible_max: 0.1 +- tenminutefixed_max_xaxis_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- tenminutefixed_max_yaxis_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- tenminutefixed_max_zaxis_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- signal_strength_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- dutycycle_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- min_zone_air_relative_humidity_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- min_zone_air_relative_humidity_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 + +## New fields for air quality sensors +- thirtysecondrolling_average_zone_air_co_concentration_sensor: + flexible_min: 0.00035 + flexible_max: 0.0015 +- thirtysecondrolling_average_zone_air_particle_diameter_sensor: + fixed_min: 0.0 + flexible_max: 0.01 +- zone_air_no2_probability_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- zone_air_no2_ozone_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 + +#added for new Pre-action Fire Supression system +- supervisor_alarm: + - ACTIVE + - INACTIVE +- water_flowrate_status: + - ACTIVE + - INACTIVE +- air_pressure_status: + - ACTIVE + - INACTIVE + +# added for WM_WFR +- water_flowrate_sensor: + flexible_min: -0.000315451 + flexible_max: 0.315451 +# added for FAN_ST +- air_pressure_sensor: + flexible_min: 500.0 + flexible_max: 200000.0 +- heat_recovery_water_isolation_valve_command: + - OPEN + - CLOSED +- heat_recovery_return_water_isolation_valve_command: + - OPEN + - CLOSED +- heat_recovery_return_water_isolation_valve_status: + - OPEN + - CLOSED +- heat_recovery_supply_water_isolation_valve_command: + - OPEN + - CLOSED +- heat_recovery_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- heat_recovery_run_command: + - ON + - OFF +- exhaust_air_differential_pressure_sensor: + flexible_min: -996.320096 + flexible_max: 996.320096 +- leaving_heat_recovery_coil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- zone_floor_temperature_sensor: + flexible_min: 272.037037 + flexible_max: 305.3703704 +- zone_floor_temperature_setpoint: + flexible_min: 272.037037 + flexible_max: 305.3703704 +- entering_heat_recovery_coil_temperature_sensor: + flexible_min: 277.5925926 + flexible_max: 310.9259259 +- carbon_filter_differential_pressure_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- leaving_coil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- heat_recovery_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- heat_recovery_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 338.7037037 +- differential_temperature_sensor: + flexible_min: 254.8148148 + flexible_max: 380.3703704 +- hot_water_tank_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- hot_water_tank_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- preheating_water_tank_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- preheating_water_tank_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_hot_leaving_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- potable_hot_leaving_water_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 380.3703704 + +## New fields for electrical system additions +- voltage_sensor: + flexible_min: 0.0 + flexible_max: 1000.0 +- input_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- output_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- bypass_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- input_phase1_phase2_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase2_phase3_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase3_phase1_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase1_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase2_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase3_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase1_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase2_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase3_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- output_phase1_phase2_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- output_phase2_phase3_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- output_phase3_phase1_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- output_phase1_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- output_phase2_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- output_phase3_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- output_phase1_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- output_phase2_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- output_phase3_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- bypass_phase1_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- bypass_phase2_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- bypass_phase3_neutral_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- remaining_charge_time_sensor: + fixed_min: 0.0 + flexible_max: 100000.0 +- output_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- output_apparent_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- low_battery_charge_alarm: + - ACTIVE + - INACTIVE +- load_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- bypass_status: + - BYPASS + - INACTIVE +- failed_inverter_alarm: + - ACTIVE + - INACTIVE + +## Refrigerant monitoring fields for AHUs +- condensing_fan_current_sensor: + fixed_min: 0.0 + flexible_max: 100.0 +- discharge_air_specificenthalpy_sensor: + flexible_min: 11630.0 + flexible_max: 81410.0 +- refrigerant_discharge_pressure_sensor: + flexible_min: -34500.0 + flexible_max: 344737.8945 +- refrigerant_liquid_pressure_sensor: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- refrigerant_liquid_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- refrigerant_liquid_saturation_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- refrigerant_subcooling_temperature_sensor: + flexible_min: 227.5925926 + flexible_max: 366.4814815 +- refrigerant_suction_pressure_sensor: + flexible_min: -34473.78945 + flexible_max: 344737.8945 +- refrigerant_suction_saturation_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- refrigerant_suction_superheat_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- return_air_specificenthalpy_sensor: + flexible_min: 11630.0 + flexible_max: 81410.0 +- compressor_current_sensor: + fixed_min: 0.0 + flexible_max: 100.0 + +## Water Level status +- water_level_status: + - HIGH + - MEDIUM + - LOW + +## New fields for steam/water heat exchanger +- supply_steam_static_pressure_sensor: + flexible_min: 0.0 + flexible_max: 2068428.0 +- supply_steam_static_pressure_setpoint: + flexible_min: 0.0 + flexible_max: 2068428.0 +- steam_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 + +# Open-loop CDW system +- outside_condensing_loop_return_water_isolation_valve_status: + - OPEN + - CLOSED +- outside_condensing_loop_return_water_isolation_valve_command: + - OPEN + - CLOSED +- outside_condensing_loop_return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- outside_condensing_loop_return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- outside_condensing_loop_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 + +# Rodent Repellent system +- transducer_failed_alarm: + - ACTIVE + - INACTIVE + +# Buffer tanks with temperature sensors +- chilled_water_temperature_sensor: + flexible_min: 274.8148148 + flexible_max: 299.8148148 +- heating_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- leaving_water_tank_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- entering_water_tank_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 + +# Tank level +- percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- secondary_heating_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- secondary_heating_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- primary_heating_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- primary_heating_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 380.3703704 +- secondary_chilled_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- secondary_chilled_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- primary_chilled_supply_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- primary_chilled_return_water_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 308.1481481 +- secondary_chilled_return_water_isolation_valve_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- secondary_chilled_return_water_isolation_valve_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- thermal_energy_accumulator: + fixed_min: 0.0 + flexible_max: 3517000.0 +- ground_isolation_command: + - ON + - OFF +- ground_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 299.8148148 + + +## Addition of new fields# + +## New fields for Freezer (Walk in Cold room) +- defrost_run_status: + - ON + - OFF +- defrost_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 322.037037 +- discharge_fan_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- defrost_temperature_setpoint: + flexible_min: 255.9259259 + flexible_max: 299.8148148 +- defrost_run_command: + - ON + - OFF +- input_motor_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- input_motor_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- motor_powerfactor_sensor: + fixed_min: 0.0 + fixed_max: 1.0 +- average_input_inter_line_motor_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- average_input_line_motor_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase1_line_motor_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase2_line_motor_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase3_line_motor_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase1_phase3_line_motor_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase1_phase2_line_motor_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase2_phase3_line_motor_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_phase1_line_inverter_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase2_line_inverter_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- input_phase3_line_inverter_current_sensor: + fixed_min: 0.0 + flexible_max: 500.0 +- output_inverter_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- input_inverter_frequency_sensor: + flexible_min: -0.5 + flexible_max: 65.0 +- output_inverter_power_sensor: + flexible_min: 0.0 + flexible_max: 10000000.0 +- refrigerant_differential_pressure_sensor: + flexible_min: -3447.38 + flexible_max: 137895.2 +- chilled_side_ground_supply_economizer_isolation_valve_status: + - OPEN + - CLOSED +- chilled_side_ground_return_economizer_isolation_valve_status: + - OPEN + - CLOSED +- chilled_side_ground_return_economizer_isolation_valve_command: + - OPEN + - CLOSED +- heating_side_ground_supply_economizer_isolation_valve_status: + - OPEN + - CLOSED +- heating_side_ground_return_economizer_isolation_valve_status: + - OPEN + - CLOSED +- heating_side_ground_return_economizer_isolation_valve_command: + - OPEN + - CLOSED +- chilled_side_ground_return_water_isolation_valve_status: + - OPEN + - CLOSED +- chilled_side_ground_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- chilled_side_ground_supply_water_isolation_valve_command: + - OPEN + - CLOSED +- heating_side_ground_return_water_isolation_valve_status: + - OPEN + - CLOSED +- heating_side_ground_supply_water_isolation_valve_status: + - OPEN + - CLOSED +- heating_side_ground_supply_water_isolation_valve_command: + - OPEN + - CLOSED + +## New fields for Fresh Air Fan With VFD +- output_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- motor_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 + +# Addition of telemetry for parking exhaust fan +- low_limit_zone_air_co_concentration_setpoint: + flexible_min: 0.00035 + flexible_max: 0.0015 +- high_limit_zone_air_co_concentration_setpoint: + flexible_min: 0.00035 + flexible_max: 0.0015 +- low_limit_zone_air_no_concentration_setpoint: + fixed_min: 0.0 + flexible_max: 0.0005 +- high_limit_zone_air_no_concentration_setpoint: + fixed_min: 0.0 + flexible_max: 0.0005 +- zone_air_no_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.0001 +- low_exhaust_fan_speed_command: + - ON + - OFF +- high_exhaust_fan_speed_command: + - ON + - OFF +- low_exhaust_fan_speed_status: + - ON + - OFF +- high_exhaust_fan_speed_status: + - ON + - OFF + +# Addition of telemetry for UPS battery monitoring +- battery_status: + - ACTIVE + - INACTIVE +- inverter_mode: + - SYNCHRONOUS + - ASYNCHRONOUS +- bypass_phase_status: + - NORMAL + - REVERSED +- rectifier_mode: + - OFF + - ON + - SOFTSTART + - BATTERY +- input_supply_mode: + - NORMAL + - BATTERY + - OFF +- battery_test_status: + - ACTIVE + - INACTIVE +- inverter_status: + - OFF + - ON + +# Addition of telemetry for scrubber +- scrubber_run_mode: + - AUTO + - MANUAL +- scrubber_run_command: + - ON + - OFF +- scrubber_run_status: + - ON + - OFF + +# telemetry fields for exhaust fan# +- speed_mode: + - VFD + - BYPASS + - AUTO + - LOW + - HIGH + - OFF +- high_discharge_fan_speed_status: + - ON + - OFF +- low_discharge_fan_speed_status: + - ON + - OFF + +##Fields for generator## +- oil_temperature_sensor: + flexible_min: 255.9259259 + flexible_max: 422.037037 +- oil_pressure_sensor: + flexible_min: 0.0 + flexible_max: 1034214.0 +- tank_level_status: + - LOW + - MEDIUM + - HIGH +- battery_voltage_sensor: + flexible_min: 0.0 + flexible_max: 15.0 +- battery_current_sensor: + fixed_min: 0.0 + flexible_max: 1.0 +- battery_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 + +#Telemetry addition for MAU# + + +#Telemetry fields for APU(MAU)# +- dc_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- ac_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- supply_fan_run_mode: + - AUTO + - MANUAL +- supply_fan_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- exhaust_fan_run_mode: + - AUTO + - MANUAL + +# Addition of telemetry for outside sensors +- outside_air_co2_concentration_sensor: + flexible_min: 0.00005 + flexible_max: 0.005 + +#Addition of new fields for Tanks## +- level_status: + - LOW + - MEDIUM + - HIGH +- line_pressure_sensor: + flexible_min: 0.0 + flexible_max: 689476.0 +- return_air_isolation_damper_status: + - OPEN + - CLOSED +- return_air_isolation_damper_command: + - OPEN + - CLOSED +- discharge_air_isolation_damper_status: + - OPEN + - CLOSED +- discharge_air_isolation_damper_command: + - OPEN + - CLOSED +- supply_fan_speed_mode: + - BYPASS + - VFD +- supply_fan_voltage_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- humidifier_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- heater_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- supply_fan_power_status: + - ON + - OFF +- discharge_fan_run_mode: + - AUTO + - MANUAL +- exhaust_fan_speed_mode: + - BYPASS + - VFD + +## New fields for EM## +- electricalgrid_energy_accumulator: + fixed_min: 0.0 + flexible_max: 4000000.0 +- generator_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- generator_energy_accumulator: + fixed_min: 0.0 + flexible_max: 4000000.0 +- electricalgrid_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 + +## New fields for fans## +- discharge_fan_energy_accumulator: + fixed_min: 0.0 + flexible_max: 100000.0 +- supply_fan_energy_accumulator: + fixed_min: 0.0 + flexible_max: 100000.0 +- compressor_run_time_accumulator: + fixed_min: 0.0 + flexible_max: 1.25 +- total_failed_lamp_counter: + fixed_min: 0.0 + flexible_max: 10000000.0 +- total_failed_wireless_device_counter: + fixed_min: 0.0 + flexible_max: 10000000.0 +- total_failed_communication_counter: + fixed_min: 0.0 + flexible_max: 10000000.0 + +## New field for AHU +- mixed_air_damper_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- mixed_air_damper_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 + +## New fields for seismic detector +- seismic_alarm: + - ACTIVE + - INACTIVE + +- lighting_color_cie_xvalue_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- lighting_color_cie_yvalue_sensor: + flexible_min: 0.0 + flexible_max: 500.0 +- lighting_color_hsl_saturation_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- lighting_color_hsl_hue_angle_sensor: + fixed_min: 0.0 + fixed_max: 360.0 +- lighting_color_cie_xvalue_setpoint: + flexible_min: 0.0 + flexible_max: 500.0 +- lighting_color_cie_yvalue_setpoint: + flexible_min: 0.0 + flexible_max: 500.0 +- lighting_color_hsl_saturation_percentage_setpoint: + fixed_min: 0.0 + fixed_max: 100.0 +- lighting_color_hsl_hue_angle_setpoint: + fixed_min: 0.0 + fixed_max: 360.0 +- luminaire_alarm: + - ACTIVE + - INACTIVE +- group_alarm: + - ACTIVE + - INACTIVE +- group_mode: + - DIMMING + - CONSTANT_LIGHT_CONTROL + - AUTO + - SCENE_CONTROL +- high_limit_illuminance_setpoint: + flexible_min: 0.0 + flexible_max: 5000.0 +- low_limit_illuminance_setpoint: + flexible_min: 0.0 + flexible_max: 5000.0 +- brightness_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 +- heating_output_percentage_command: + fixed_min: 0.0 + fixed_max: 100.0 +- dimmer_run_status: + - ON + - OFF +- wind_alarm: + - ACTIVE + - INACTIVE +- rain_alarm: + - ACTIVE + - INACTIVE +- outside_illuminance_sensor: + flexible_min: 0.0 + flexible_max: 5000.0 +- shade_orientation_specification: + - NORTH + - SOUTH + - EAST + - WEST +- shade_mode: + - MANUAL + - AUTO + - DAY_NIGHT + - THERMAL + - WINDOW_OPEN + +## New fields for RO water system +- water_totaldissolvedsolids_concentration_sensor: + flexible_min: 0.0 + flexible_max: 0.001 + +## New field for VAV +- high_limit_zone_air_co2_concentration_setpoint: + flexible_min: 0.00005 + flexible_max: 0.005 +- low_limit_zone_air_co2_concentration_setpoint: + flexible_min: 0.00005 + flexible_max: 0.005 + +## New field for SDC +- shade_extent_percentage_sensor: + fixed_min: 0.0 + fixed_max: 100.0 + +## New alarms added 1/25/23 +- failed_circulation_pump_alarm: + - ACTIVE + - INACTIVE +- failed_discharge_air_temperature_alarm: + - ACTIVE + - INACTIVE +- failed_exhaust_air_temperature_alarm: + - ACTIVE + - INACTIVE +- failed_heating_water_valve_alarm: + - ACTIVE + - INACTIVE +- failed_isolation_valve_alarm: + - ACTIVE + - INACTIVE +- failed_mixed_air_temperature_alarm: + - ACTIVE + - INACTIVE +- failed_return_air_isolation_damper_alarm: + - ACTIVE + - INACTIVE +- failed_smoke_detection_alarm: + - ACTIVE + - INACTIVE +- failed_supply_air_isolation_damper_alarm: + - ACTIVE + - INACTIVE +- failed_zone_air_temperature_alarm: + - ACTIVE + - INACTIVE +- high_differential_pressure_alarm: + - ACTIVE + - INACTIVE +- high_supply_air_static_pressure_alarm: + - ACTIVE + - INACTIVE +- high_supply_air_temperature_alarm: + - ACTIVE + - INACTIVE +- high_supply_water_temperature_alarm: + - ACTIVE + - INACTIVE +- high_return_water_temperature_alarm: + - ACTIVE + - INACTIVE +- high_zone_air_co2_concentration_alarm: + - ACTIVE + - INACTIVE +- high_zone_air_static_pressure_alarm: + - ACTIVE + - INACTIVE +- high_zone_air_temperature_alarm: + - ACTIVE + - INACTIVE +- local_alarm: + - ACTIVE + - INACTIVE +- local_override_alarm: + - ACTIVE + - INACTIVE +- local_override_isolation_valve_alarm: + - ACTIVE + - INACTIVE +- high_building_air_static_pressure_alarm: + - ACTIVE + - INACTIVE +- low_building_air_static_pressure_alarm: + - ACTIVE + - INACTIVE +- low_supply_air_static_pressure_alarm: + - ACTIVE + - INACTIVE +- low_supply_air_temperature_alarm: + - ACTIVE + - INACTIVE +- low_supply_water_temperature_alarm: + - ACTIVE + - INACTIVE +- low_return_water_temperature_alarm: + - ACTIVE + - INACTIVE +- low_zone_air_static_pressure_alarm: + - ACTIVE + - INACTIVE +- low_zone_air_temperature_alarm: + - ACTIVE + - INACTIVE +- failed_communication_alarm: + - ACTIVE + - INACTIVE +- low_flowrate_alarm: + - ACTIVE + - INACTIVE +- high_zone_air_co_concentration_alarm: + - ACTIVE + - INACTIVE +- failed_discharge_air_isolation_damper_alarm: + - ACTIVE + - INACTIVE +- high_speed_command: + - ON + - OFF +- low_speed_command: + - ON + - OFF +- high_speed_status: + - ON + - OFF +- low_speed_status: + - ON + - OFF + +- high_water_temperature_alarm: + - ACTIVE + - INACTIVE + +- ultraviolet_irradiance_sensor: + fixed_min: 0.0 + flexible_max: 2000.0 + +- purge_command: + - ON + - OFF + +- high_discharge_air_temperature_alarm: + - ACTIVE + - INACTIVE + +- low_discharge_air_temperature_alarm: + - ACTIVE + - INACTIVE + +- high_discharge_air_static_pressure_alarm: + - ACTIVE + - INACTIVE + +- low_discharge_air_static_pressure_alarm: + - ACTIVE + - INACTIVE + +- soundpressurelevel_sensor: + fixed_min: -60 + flexible_max: 200 + +- zone_occupant_counter: + fixed_min: 0 + flexible_max: 1000 + +- zone_air_voc_aqi_sensor: + fixed_min: 0 + flexible_max: 500 + +- zone_air_smoke_aqi_sensor: + fixed_min: 0 + flexible_max: 80 + +- tamper_status: + - ON + - OFF + From 42831278d5fc63f97bc832d9acb4de3cecd795dc Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 21 Aug 2023 10:41:22 +0100 Subject: [PATCH 19/26] add occupancy counter sensor --- ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index f58cfd8019..38f2686b6c 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -313,4 +313,11 @@ SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_IAQMI_TMPR: - zone_air_voc_aqi_sensor - zone_air_smoke_aqi_sensor - motion_status - - tamper_status \ No newline at end of file + - tamper_status + +SENSOR_ZOC: + description: "Zone occupant counter sensor." + is_canonical: true + implements: + - /SENSOR + - ZOC \ No newline at end of file From 5138f33a73416e2bf90ab2cf0059811f0ea20e1a Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Mon, 21 Aug 2023 11:20:53 +0100 Subject: [PATCH 20/26] added an abstract type for zone aqi indexes --- .../yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 10 ++++++++++ ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 5 +---- 2 files changed, 11 insertions(+), 4 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index a5a58d8cbc..431820f1a6 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6826,3 +6826,13 @@ SPLM: - soundpressurelevel_sensor implements: - MONITORING + +ZAQI: + description: "Zone air quality indexes monitoring" + is_abstract: true + uses: + - zone_air_aqi_sensor + - zone_air_voc_aqi_sensor + - zone_air_smoke_aqi_sensor + implements: + - MONITORING diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index 38f2686b6c..a847de0f00 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -294,7 +294,7 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PML: - zone_air_pm2pt5_density_sensor - zone_air_pm10pt0_density_sensor -SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_IAQMI_TMPR: +SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_ZAQI_TMPR: description: "Indoor Air Quality sensor with temperature, humidity, CO2, CO, sound, particulates (density), illuminance, formaldehyde, pressure sensors with air quality, vape, TVOC indexes and motion & tamper detection." is_canonical: true implements: @@ -309,9 +309,6 @@ SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_IAQMI_TMPR: - illuminance_sensor - zone_air_pm2pt5_density_sensor - zone_air_formaldehyde_concentration_sensor - - zone_air_aqi_sensor - - zone_air_voc_aqi_sensor - - zone_air_smoke_aqi_sensor - motion_status - tamper_status From 22670065116264d07db448644cfca645ff6b8448 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Tue, 22 Aug 2023 10:44:59 +0100 Subject: [PATCH 21/26] added new aqi unit --- ontology/yaml/resources/units/units.yaml | 3 +++ 1 file changed, 3 insertions(+) diff --git a/ontology/yaml/resources/units/units.yaml b/ontology/yaml/resources/units/units.yaml index c7bc982070..0d9d0618f3 100644 --- a/ontology/yaml/resources/units/units.yaml +++ b/ontology/yaml/resources/units/units.yaml @@ -38,6 +38,9 @@ aqi: uba: # Umwelt Bundesamt, German air quality standard multiplier: 1 offset: 0 + awair: # Awair Air Quality Score + multiplier: 1 + offset: 0 area: square_meters: STANDARD square_centimeters: From 249acc80cd0598cffe1ed90e01e2879673ba809a Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Thu, 24 Aug 2023 10:33:40 +0100 Subject: [PATCH 22/26] changes based on feedback --- .../resources/HVAC/entity_types/ABSTRACT.yaml | 16 ++++++++++++++-- .../resources/HVAC/entity_types/SENSOR.yaml | 18 +++++++----------- .../resources/fields/telemetry_fields.yaml | 8 ++++---- .../yaml/resources/subfields/subfields.yaml | 1 - 4 files changed, 25 insertions(+), 18 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 73ac4ccbe4..043df9c731 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -1479,6 +1479,8 @@ VOCM: is_abstract: true uses: - zone_air_voc_concentration_sensor + opt_uses: + - zone_air_formaldehyde_concentration_sensor implements: - MONITORING @@ -6829,12 +6831,22 @@ SPLM: implements: - MONITORING -ZAQI: +ZAQIM: description: "Zone air quality indexes monitoring" - is_abstract: true + is_abstract: truezone_air_formaldehyde_concentration_sensor uses: - zone_air_aqi_sensor + opt_uses: - zone_air_voc_aqi_sensor - zone_air_smoke_aqi_sensor implements: - MONITORING + +PMDM: + description: "Particulate matter density monitoring" + is_abstract: true + uses: + - zone_air_pm2pt5_density_sensor + - zone_air_pm10pt0_density_sensor + implements: + - MONITORING \ No newline at end of file diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index a847de0f00..e6478ae914 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -265,7 +265,7 @@ SENSOR_ZTM_ZHM_ZOC: - ZHM - ZOC -SENSOR_ZTM_ZHM_CO2M_VOCM_PML_SPLM: +SENSOR_ZTM_ZHM_CO2M_VOCM_PMDM_SPLM_ZAQIM: description: "Indoor Air Quality sensor with temperature, humidity, CO2, VOC, particulates (density), illuminance and sound monitoring." is_canonical: true implements: @@ -275,13 +275,11 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PML_SPLM: - CO2M - VOCM - SPLM + - ZAQIM uses: - - zone_air_aqi_sensor - illuminance_sensor - - zone_air_pm2pt5_density_sensor - - zone_air_pm10pt0_density_sensor -SENSOR_ZTM_ZHM_CO2M_VOCM_PML: +SENSOR_ZTM_ZHM_CO2M_VOCM_PMDM: description: "Indoor Air Quality sensor with temperature, humidity, CO2, VOC, particulates (density) monitoring." is_canonical: true implements: @@ -290,11 +288,9 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PML: - ZHM - CO2M - VOCM - uses: - - zone_air_pm2pt5_density_sensor - - zone_air_pm10pt0_density_sensor + - PMDM -SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_ZAQI_TMPR: +SENSOR_ZTM_ZHM_CO2M_SPLM_PMDM_COM_ZSPM_VOCM_MS_ZAQIM_TMPR: description: "Indoor Air Quality sensor with temperature, humidity, CO2, CO, sound, particulates (density), illuminance, formaldehyde, pressure sensors with air quality, vape, TVOC indexes and motion & tamper detection." is_canonical: true implements: @@ -303,12 +299,12 @@ SENSOR_ZTM_ZHM_CO2M_SPLM_PLM_COM_ZSPM_MS_ZAQI_TMPR: - ZHM - CO2M - SPLM + - PMDM - COM - ZSPM + - VOCM uses: - illuminance_sensor - - zone_air_pm2pt5_density_sensor - - zone_air_formaldehyde_concentration_sensor - motion_status - tamper_status diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index 0432db94f7..fe4dd3f802 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -3187,7 +3187,7 @@ literals: fixed_min: -60 flexible_max: 200 -- zone_occupant_counter: +- zone_occupancy_count: fixed_min: 0 flexible_max: 1000 @@ -3199,7 +3199,7 @@ literals: fixed_min: 0 flexible_max: 80 -- tamper_status: - - ON - - OFF +- tamper_alarm: + - ACTIVE + - INACTIVE diff --git a/ontology/yaml/resources/subfields/subfields.yaml b/ontology/yaml/resources/subfields/subfields.yaml index f5fe21699c..24c8f0691b 100644 --- a/ontology/yaml/resources/subfields/subfields.yaml +++ b/ontology/yaml/resources/subfields/subfields.yaml @@ -170,7 +170,6 @@ descriptor: no2: "Nitrogen dioxide." north: "Cardinal direction; opposite of south" occupancy: "State of being occupied." - occupant: "A person who occupies a space." occupied: "State of being within scheduled (time of day or week) run-time parameters." oil: "A viscous liquid derived from petroleum, especially for use as a fuel or lubricant." ongoing: "Hapenning currently, right now." From f5fd09029ae4452a42c879b9c7fc32d5e4392af5 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Thu, 24 Aug 2023 10:35:50 +0100 Subject: [PATCH 23/26] Update SENSOR.yaml --- ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index e6478ae914..5f8d431c85 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -306,7 +306,7 @@ SENSOR_ZTM_ZHM_CO2M_SPLM_PMDM_COM_ZSPM_VOCM_MS_ZAQIM_TMPR: uses: - illuminance_sensor - motion_status - - tamper_status + - tamper_alarm SENSOR_ZOC: description: "Zone occupant counter sensor." From 5301232f8243aff0a244260ff433f2ac41a7b41d Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Thu, 24 Aug 2023 10:37:11 +0100 Subject: [PATCH 24/26] Update ABSTRACT.yaml --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 043df9c731..c74d09ebd3 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6819,7 +6819,7 @@ ZOC: description: "Occupancy counter monitoring" is_abstract: true uses: - - zone_occupant_counter + - zone_occupancy_count implements: - MONITORING From c8196c662c788372f7be5dceba4836ba8fe2d2c2 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Thu, 24 Aug 2023 10:53:41 +0100 Subject: [PATCH 25/26] update forgotten abstract types --- ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml index 5f8d431c85..528d9d0b8c 100644 --- a/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/SENSOR.yaml @@ -274,6 +274,7 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMDM_SPLM_ZAQIM: - ZHM - CO2M - VOCM + - PMDM - SPLM - ZAQIM uses: @@ -290,7 +291,7 @@ SENSOR_ZTM_ZHM_CO2M_VOCM_PMDM: - VOCM - PMDM -SENSOR_ZTM_ZHM_CO2M_SPLM_PMDM_COM_ZSPM_VOCM_MS_ZAQIM_TMPR: +SENSOR_ZTM_ZHM_CO2M_SPLM_PMDM_COM_ZSPM_VOCM_ZAQIM_MS_TMPR: description: "Indoor Air Quality sensor with temperature, humidity, CO2, CO, sound, particulates (density), illuminance, formaldehyde, pressure sensors with air quality, vape, TVOC indexes and motion & tamper detection." is_canonical: true implements: @@ -303,6 +304,7 @@ SENSOR_ZTM_ZHM_CO2M_SPLM_PMDM_COM_ZSPM_VOCM_MS_ZAQIM_TMPR: - COM - ZSPM - VOCM + - ZAQIM uses: - illuminance_sensor - motion_status From b4f63390129b60233c9cac42407e3b05e5c51988 Mon Sep 17 00:00:00 2001 From: adelin-diac <105500899+adelin-diac@users.noreply.github.com> Date: Wed, 30 Aug 2023 11:20:22 +0100 Subject: [PATCH 26/26] removed mistake --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index c74d09ebd3..64e34d53a5 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -6833,7 +6833,7 @@ SPLM: ZAQIM: description: "Zone air quality indexes monitoring" - is_abstract: truezone_air_formaldehyde_concentration_sensor + is_abstract: true uses: - zone_air_aqi_sensor opt_uses: