@@ -8,6 +8,12 @@ Get notified for changes in the API and its documentation when something has cha
8
8
9
9
## Changes
10
10
11
+
### 2024-01-30
12
+
13
+
Documentation for the HWE-KWH1 and HWE-KWH3 is added. These devices are a direct replacement for the SDM230-wifi and SDM630-wifi, with the only difference that the model name is changed.
14
+
15
+
## Changes
16
+
11
17
### 2024-01-19
12
18
13
19
Documentation for the updated kWh Meter firmware firmware has been added, which brings more data in the `api/v1/data` endpoint.
Copy file name to clipboardExpand all lines: docs/endpoints/api-v1-data.mdx
+52-47Lines changed: 52 additions & 47 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -197,57 +197,62 @@ Content-Length: <length>
197
197
}
198
198
```
199
199
200
-
## kWh Meters (SDM230-wifi and SDM630-wifi)
200
+
## kWh Meters (1 and 3 phase)
201
201
202
202
:::info New firmware version
203
203
Firmware version 4.00 is currently in beta and will be available soon for everyone. You meter will automatically update to this version when it is available.
204
204
:::
205
205
206
+
Each type of meter is available in two versions. The API and functionality is the same for both types.
207
+
208
+
-**1-phase**: HWE-KWH1 and SDM230-wifi
209
+
-**3-phase**: HWE-KWH3 and SDM630-wifi
210
+
206
211
### Data points
207
212
208
-
| Data | Type | Available for | Description| Required firmware version |
| wifi_ssid | String |SDM230-wifi, SDM630-wifi| The Wi-Fi network that the meter is connected to| 3.06 or later |
211
-
| wifi_strength | Number |SDM230-wifi, SDM630-wifi| The strength of the Wi-Fi signal in %| 3.06 or later |
212
-
| total_power_import_kwh | Number |SDM230-wifi, SDM630-wifi| The power usage meter reading in kWh| 4.00 or later |
213
-
| total_power_import_t1_kwh | Number |SDM230-wifi, SDM630-wifi| Same value as `total_power_import_t1_kwh`, kept for backwards compatibility| 3.06 or later |
214
-
| total_power_export_kwh | Number |SDM230-wifi, SDM630-wifi| The power feed-in meter reading in kWh| 4.00 or later |
215
-
| total_power_export_t1_kwh | Number |SDM230-wifi, SDM630-wifi| Same value as `total_power_export_kwh`, kept for backwards compatibility| 3.06 or later |
216
-
| active_power_w | Number |SDM230-wifi, SDM630-wifi| The total active usage in watt| 3.06 or later |
217
-
| active_power_l1_w | Number |SDM230-wifi, SDM630-wifi| The active usage for phase 1 in watt, same as `active_power_w` for SDM230-wifi| 3.06 or later |
218
-
| active_power_l2_w | Number |SDM630-wifi| The active usage for phase 2 in watt| 3.06 or later |
219
-
| active_power_l3_w | Number |SDM630-wifi| The active usage for phase 3 in watt| 3.06 or later |
220
-
| active_voltage_v | Number |SDM230-wifi| The active voltage in volts| 4.00 or later |
221
-
| active_voltage_l1_v | Number |SDM630-wifi| The active voltage for phase 1 in volts| 4.00 or later |
222
-
| active_voltage_l2_v | Number |SDM630-wifi| The active voltage for phase 2 in volts| 4.00 or later |
223
-
| active_voltage_l3_v | Number |SDM630-wifi| The active voltage for phase 3 in volts| 4.00 or later |
224
-
| active_current_a | Number |SDM230-wifi, SDM630-wifi| The active current in amperes, the sum of all phases for SDM630-wifi| 4.00 or later |
225
-
| active_current_l1_a | Number |SDM630-wifi| The active current for phase 1 in amperes| 4.00 or later |
226
-
| active_current_l2_a | Number |SDM630-wifi| The active current for phase 2 in amperes| 4.00 or later |
227
-
| active_current_l3_a | Number |SDM630-wifi| The active current for phase 3 in amperes| 4.00 or later |
228
-
| active_apparent_current_a | Number |SDM230-wifi, SDM630-wifi| The apparent current in amperes, the sum of all phases for SDM630-wifi| 4.00 or later |
229
-
| active_apparent_current_l1_a | Number |SDM630-wifi| The apparent current for phase 1 in amperes| 4.00 or later |
230
-
| active_apparent_current_l2_a | Number |SDM630-wifi| The apparent current for phase 2 in amperes| 4.00 or later |
231
-
| active_apparent_current_l3_a | Number |SDM630-wifi| The apparent current for phase 3 in amperes| 4.00 or later |
232
-
| active_reactive_current_a | Number |SDM230-wifi, SDM630-wifi| The reactive current in amperes, the sum of all phases for SDM630-wifi| 4.00 or later |
233
-
| active_reactive_current_l1_a | Number |SDM630-wifi| The reactive current for phase 1 in amperes| 4.00 or later |
234
-
| active_reactive_current_l2_a | Number |SDM630-wifi| The reactive current for phase 2 in amperes| 4.00 or later |
235
-
| active_reactive_current_l3_a | Number |SDM630-wifi| The reactive current for phase 3 in amperes| 4.00 or later |
236
-
| active_apparent_power_va | Number |SDM230-wifi, SDM630-wifi| The apparent power in volt-amperes, the sum of all phases for SDM630-wifi| 4.00 or later |
237
-
| active_apparent_power_l1_va | Number |SDM630-wifi| The apparent power for phase 1 in volt-amperes| 4.00 or later |
238
-
| active_apparent_power_l2_va | Number |SDM630-wifi| The apparent power for phase 2 in volt-amperes| 4.00 or later |
239
-
| active_apparent_power_l3_va | Number |SDM630-wifi| The apparent power for phase 3 in volt-amperes| 4.00 or later |
240
-
| active_reactive_power_var | Number |SDM230-wifi, SDM630-wifi| The reactive power in volt-amperes reactive, the sum of all phases for SDM630-wifi| 4.00 or later |
241
-
| active_reactive_power_l1_var | Number |SDM630-wifi| The reactive power for phase 1 in volt-amperes reactive| 4.00 or later |
242
-
| active_reactive_power_l2_var | Number |SDM630-wifi| The reactive power for phase 2 in volt-amperes reactive| 4.00 or later |
243
-
| active_reactive_power_l3_var | Number |SDM630-wifi| The reactive power for phase 3 in volt-amperes reactive| 4.00 or later |
244
-
| active_power_factor | Number |SDM230-wifi| The power factor| 4.00 or later |
245
-
| active_power_factor_l1 | Number |SDM630-wifi| The power factor for phase 1| 4.00 or later |
246
-
| active_power_factor_l2 | Number |SDM630-wifi| The power factor for phase 2| 4.00 or later |
247
-
| active_power_factor_l3 | Number |SDM630-wifi| The power factor for phase 3| 4.00 or later |
248
-
| active_frequency_hz | Number |SDM230-wifi, SDM630-wifi| The frequency in hertz| 4.00 or later |
249
-
250
-
### Example: SDM230-wifi (firmware version 3.06)
213
+
| Data | Type | Available for | Description | Required firmware version |
| wifi_ssid | String |1-phase, 3-phase| The Wi-Fi network that the meter is connected to | 3.06 or later |
216
+
| wifi_strength | Number |1-phase, 3-phase| The strength of the Wi-Fi signal in % | 3.06 or later |
217
+
| total_power_import_kwh | Number |1-phase, 3-phase| The power usage meter reading in kWh | 4.00 or later |
218
+
| total_power_import_t1_kwh | Number |1-phase, 3-phase| Same value as `total_power_import_t1_kwh`, kept for backwards compatibility | 3.06 or later |
219
+
| total_power_export_kwh | Number |1-phase, 3-phase| The power feed-in meter reading in kWh | 4.00 or later |
220
+
| total_power_export_t1_kwh | Number |1-phase, 3-phase| Same value as `total_power_export_kwh`, kept for backwards compatibility | 3.06 or later |
221
+
| active_power_w | Number |1-phase, 3-phase| The total active usage in watt | 3.06 or later |
222
+
| active_power_l1_w | Number |1-phase, 3-phase| The active usage for phase 1 in watt, same as `active_power_w` for 1-phase| 3.06 or later |
223
+
| active_power_l2_w | Number |3-phase| The active usage for phase 2 in watt | 3.06 or later |
224
+
| active_power_l3_w | Number |3-phase| The active usage for phase 3 in watt | 3.06 or later |
225
+
| active_voltage_v | Number |1-phase| The active voltage in volts | 4.00 or later |
226
+
| active_voltage_l1_v | Number |3-phase| The active voltage for phase 1 in volts | 4.00 or later |
227
+
| active_voltage_l2_v | Number |3-phase| The active voltage for phase 2 in volts | 4.00 or later |
228
+
| active_voltage_l3_v | Number |3-phase| The active voltage for phase 3 in volts | 4.00 or later |
229
+
| active_current_a | Number |1-phase, 3-phase| The active current in amperes, the sum of all phases for 3-phase| 4.00 or later |
230
+
| active_current_l1_a | Number |3-phase| The active current for phase 1 in amperes | 4.00 or later |
231
+
| active_current_l2_a | Number |3-phase| The active current for phase 2 in amperes | 4.00 or later |
232
+
| active_current_l3_a | Number |3-phase| The active current for phase 3 in amperes | 4.00 or later |
233
+
| active_apparent_current_a | Number |1-phase, 3-phase| The apparent current in amperes, the sum of all phases for 3-phase| 4.00 or later |
234
+
| active_apparent_current_l1_a | Number |3-phase| The apparent current for phase 1 in amperes | 4.00 or later |
235
+
| active_apparent_current_l2_a | Number |3-phase| The apparent current for phase 2 in amperes | 4.00 or later |
236
+
| active_apparent_current_l3_a | Number |3-phase| The apparent current for phase 3 in amperes | 4.00 or later |
237
+
| active_reactive_current_a | Number |1-phase, 3-phase| The reactive current in amperes, the sum of all phases for 3-phase| 4.00 or later |
238
+
| active_reactive_current_l1_a | Number |3-phase| The reactive current for phase 1 in amperes | 4.00 or later |
239
+
| active_reactive_current_l2_a | Number |3-phase| The reactive current for phase 2 in amperes | 4.00 or later |
240
+
| active_reactive_current_l3_a | Number |3-phase| The reactive current for phase 3 in amperes | 4.00 or later |
241
+
| active_apparent_power_va | Number |1-phase, 3-phase| The apparent power in volt-amperes, the sum of all phases for 3-phase| 4.00 or later |
242
+
| active_apparent_power_l1_va | Number |3-phase| The apparent power for phase 1 in volt-amperes | 4.00 or later |
243
+
| active_apparent_power_l2_va | Number |3-phase| The apparent power for phase 2 in volt-amperes | 4.00 or later |
244
+
| active_apparent_power_l3_va | Number |3-phase| The apparent power for phase 3 in volt-amperes | 4.00 or later |
245
+
| active_reactive_power_var | Number |1-phase, 3-phase| The reactive power in volt-amperes reactive, the sum of all phases for 3-phase| 4.00 or later |
246
+
| active_reactive_power_l1_var | Number |3-phase| The reactive power for phase 1 in volt-amperes reactive | 4.00 or later |
247
+
| active_reactive_power_l2_var | Number |3-phase| The reactive power for phase 2 in volt-amperes reactive | 4.00 or later |
248
+
| active_reactive_power_l3_var | Number |3-phase| The reactive power for phase 3 in volt-amperes reactive | 4.00 or later |
249
+
| active_power_factor | Number |1-phase| The power factor | 4.00 or later |
250
+
| active_power_factor_l1 | Number |3-phase| The power factor for phase 1 | 4.00 or later |
251
+
| active_power_factor_l2 | Number |3-phase| The power factor for phase 2 | 4.00 or later |
252
+
| active_power_factor_l3 | Number |3-phase| The power factor for phase 3 | 4.00 or later |
253
+
| active_frequency_hz | Number |1-phase, 3-phase| The frequency in hertz | 4.00 or later |
0 commit comments