From a159dc6ab51e1209d02444500e29e732843e6adc Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 3 Feb 2022 17:00:47 +0100 Subject: [PATCH 01/11] Create c0.wtw04.csv source: https://forum.fhem.de/index.php/topic,29737.msg1073625.html#msg1073625 --- ebusd-2.1.x/en/vaillant/c0.wtw04.csv | 67 ++++++++++++++++++++++++++++ 1 file changed, 67 insertions(+) create mode 100644 ebusd-2.1.x/en/vaillant/c0.wtw04.csv diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv new file mode 100644 index 000000000..b21b56060 --- /dev/null +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -0,0 +1,67 @@ +# type (r[1-9] w u ),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275,,,,,,,,,,, +############ Luftvolumen################,,,,,,,,,,,,, +*r,,,,,,B509,0D,,,,,, +*w,,,,,,B509,0E,,,,,, +w,,Lüftung = 50m³/h,Lüftung = 50m³/h,,,,1500a600,,,,,, +w,,Lüftung = 55m³/h,Lüftung = 55m³/h,,,,1500b700,,,,,, +w,,Lüftung = 60m³/h,Lüftung = 60m³/h,,,,1500c800,,,,,, +w,,Lüftung = 65m³/h,Lüftung = 65m³/h,,,,1500d800,,,,,, +w,,Lüftung = 70m³/h,Lüftung = 70m³/h,,,,1500e900,,,,,, +w,,Lüftung = 75m³/h,Lüftung = 75m³/h,,,,1500fa00,,,,,, +w,,Lüftung = 80m³/h,Lüftung = 80m³/h,,,,15000a01,,,,,, +w,,Lüftung = 85m³/h,Lüftung = 85m³/h,,,,15001b01,,,,,, +w,,Lüftung = 90m³/h,Lüftung = 90m³/h,,,,15002c01,,,,,, +w,,Lüftung = 95m³/h,Lüftung = 95m³/h,,,,15003c01,,,,,, +w,,Lüftung = 100m³/h,Lüftung = 100m³/h,,,,15004d01,,,,,, +w,,Lüftung = 105m³/h,Lüftung = 105m³/h,,,,15005e01,,,,,, +w,,Lüftung = 110m³/h,Lüftung = 110m³/h,,,,15006e01,,,,,, +w,,Lüftung = 115m³/h,Lüftung = 115m³/h,,,,15007f01,,,,,, +w,,Lüftung = 120m³/h,Lüftung = 120m³/h,,,,15009001,,,,,, +w,,Lüftung = 125m³/h,Lüftung = 125m³/h,,,,1500a001,,,,,, +w,,Lüftung = 130m³/h,Lüftung = 130m³/h,,,,1500b101,,,,,, +w,,Lüftung = 135m³/h,Lüftung = 135m³/h,,,,1500c201,,,,,, +w,,Lüftung = 140m³/h,Lüftung = 140m³/h,,,,1500d201,,,,,, +w,,Lüftung = 145m³/h,Lüftung = 145m³/h,,,,1500e301,,,,,, +w,,Lüftung = 150m³/h,Lüftung = 150m³/h,,,,1500f401,,,,,, +w,,Lüftung = 155m³/h,Lüftung = 155m³/h,,,,15000402,,,,,, +w,,Lüftung = 160m³/h,Lüftung = 160m³/h,,,,15001502,,,,,, +w,,Lüftung = 165m³/h,Lüftung = 165m³/h,,,,15002602,,,,,, +w,,Lüftung = 170m³/h,Lüftung = 170m³/h,,,,15003602,,,,,, +w,,Lüftung = 175m³/h,Lüftung = 175m³/h,,,,15004702,,,,,, +w,,Lüftung = 180m³/h,Lüftung = 180m³/h,,,,15005802,,,,,, +w,,Lüftung = 185m³/h,Lüftung = 185m³/h,,,,15006802,,,,,, +w,,Lüftung = 190m³/h,Lüftung = 190m³/h,,,,15007902,,,,,, +w,,Lüftung = 195m³/h,Lüftung = 195m³/h,,,,15008a02,,,,,, +w,,Lüftung = 200m³/h,Lüftung = 200m³/h,,,,15009a02,,,,,, +w,,Lüftung = 205m³/h,Lüftung = 205m³/h,,,,1500ab02,,,,,, +w,,Lüftung = 210m³/h,Lüftung = 210m³/h,,,,1500bc02,,,,,, +w,,Lüftung = 215m³/h,Lüftung = 215m³/h,,,,1500cc02,,,,,, +w,,Lüftung = 220m³/h,Lüftung = 220m³/h,,,,1500dd02,,,,,, +w,,Lüftung = 225m³/h,Lüftung = 225m³/h,,,,1500ee02,,,,,, +w,,Lüftung = 230m³/h,Lüftung = 230m³/h,,,,1500fe02,,,,,, +w,,Lüftung = 235m³/h,Lüftung = 235m³/h,,,,15000f03,,,,,, +w,,Lüftung = 240m³/h,Lüftung = 240m³/h,,,,15002003,,,,,, +w,,Lüftung = 245m³/h,Lüftung = 245m³/h,,,,15003003,,,,,, +w,,Lüftung = 250m³/h,Lüftung = 250m³/h,,,,15004103,,,,,, +w,,Lüftung = 255m³/h,Lüftung = 255m³/h,,,,15005203,,,,,, +w,,Lüftung = 260m³/h,Lüftung = 260m³/h,,,,15006203,,,,,, +w,,Lüftung = 265m³/h,Lüftung = 265m³/h,,,,15007303,,,,,, +w,,Lüftung = 270m³/h,Lüftung = 270m³/h,,,,15008403,,,,,, +w,,Lüftung = 275m³/h,Lüftung = 275m³/h,,,,15009403,,,,,, +w,,Lüftung = 280m³/h,Lüftung = 280m³/h,,,,1500a503,,,,,, +w,,Lüftung = 285m³/h,Lüftung = 285m³/h,,,,1500b603,,,,,, +w,,Lüftung = 290m³/h,Lüftung = 290m³/h,,,,1500c603,,,,,, +w,,Lüftung = 295m³/h,Lüftung = 295m³/h,,,,1500d703,,,,,, +w,,Lüftung = 300m³/h,Lüftung = 300m³/h,,,,1500e803,,,,,, +#######Weitere #####,,,,,,,,,,,,, +r;w,,Soll-Volumenstromkorrektur,Soll-Volumenstromkorrektur,,,,2000,,,D1B,,, +r;w,,Waermerueckgewinnung,Waermerueckgewinnung,,,,0a00,,,UCH,1=an;2=aus,, +*r,,,,,,B509,29,,,IGN:2,,, +r;w,,TempInletAir_SAI,Temperatur Zuluft,,,,0100,,,temp,,, +r;w,,TempOutsideAir_SAO,Temperatur Aussenluft,,,,0200,,,temp,,, +r;w,,TempWasteAir_EAI,Temperatur Abluft,,,,0300,,,temp,,, +r;w,,TempOutgoingAir_EAO,Temperatur Fortluft,,,,0400,,,temp,,, +r;w,,Roomtemp,Zimmertemperatur,,,,0000,,,temp,,, +r;w,,Unterdruckschutz,Unterdruckschutz,,,,4700,,,UCH,1=an;0=aus,, +r;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,, From f475769f17b5a70c050c83c764f36772174a74b4 Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 3 Feb 2022 17:05:37 +0100 Subject: [PATCH 02/11] add RecoVair 275 source: https://forum.fhem.de/index.php/topic,29737.msg1073625.html#msg1073625 --- ebusd-2.1.x/en/vaillant/15.vai00.csv | 8 ++++++++ 1 file changed, 8 insertions(+) create mode 100644 ebusd-2.1.x/en/vaillant/15.vai00.csv diff --git a/ebusd-2.1.x/en/vaillant/15.vai00.csv b/ebusd-2.1.x/en/vaillant/15.vai00.csv new file mode 100644 index 000000000..2bda64aeb --- /dev/null +++ b/ebusd-2.1.x/en/vaillant/15.vai00.csv @@ -0,0 +1,8 @@ +# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275,,,,,,,,,,, +# ##### Generell #####,,,,,,,,,,,,, +*r,,,,,,B509,0D,,,,,, +*w,,,,,,B509,0F,,,,,, +r;w,,Lüftungsstufe,Lüftungsstufe,,,,2400,,,UCH,1=Tag;2=Aus;3=Auto;5=Nacht,, +r;w,,Lüftung_HI,Lüftung_HI,,,,5800,,,BCD:2,,, +r,,Uhrzeit,Uhrzeit,,,,2C00,,,VTI,,, From 2f4d8b63154b153dadae0a863d32d54c23889ae8 Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 3 Feb 2022 17:41:32 +0100 Subject: [PATCH 03/11] Update c0.wtw04.csv --- ebusd-2.1.x/en/vaillant/c0.wtw04.csv | 72 +++++----------------------- 1 file changed, 12 insertions(+), 60 deletions(-) diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv index b21b56060..67a4105a0 100644 --- a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -3,65 +3,17 @@ ############ Luftvolumen################,,,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, *w,,,,,,B509,0E,,,,,, -w,,Lüftung = 50m³/h,Lüftung = 50m³/h,,,,1500a600,,,,,, -w,,Lüftung = 55m³/h,Lüftung = 55m³/h,,,,1500b700,,,,,, -w,,Lüftung = 60m³/h,Lüftung = 60m³/h,,,,1500c800,,,,,, -w,,Lüftung = 65m³/h,Lüftung = 65m³/h,,,,1500d800,,,,,, -w,,Lüftung = 70m³/h,Lüftung = 70m³/h,,,,1500e900,,,,,, -w,,Lüftung = 75m³/h,Lüftung = 75m³/h,,,,1500fa00,,,,,, -w,,Lüftung = 80m³/h,Lüftung = 80m³/h,,,,15000a01,,,,,, -w,,Lüftung = 85m³/h,Lüftung = 85m³/h,,,,15001b01,,,,,, -w,,Lüftung = 90m³/h,Lüftung = 90m³/h,,,,15002c01,,,,,, -w,,Lüftung = 95m³/h,Lüftung = 95m³/h,,,,15003c01,,,,,, -w,,Lüftung = 100m³/h,Lüftung = 100m³/h,,,,15004d01,,,,,, -w,,Lüftung = 105m³/h,Lüftung = 105m³/h,,,,15005e01,,,,,, -w,,Lüftung = 110m³/h,Lüftung = 110m³/h,,,,15006e01,,,,,, -w,,Lüftung = 115m³/h,Lüftung = 115m³/h,,,,15007f01,,,,,, -w,,Lüftung = 120m³/h,Lüftung = 120m³/h,,,,15009001,,,,,, -w,,Lüftung = 125m³/h,Lüftung = 125m³/h,,,,1500a001,,,,,, -w,,Lüftung = 130m³/h,Lüftung = 130m³/h,,,,1500b101,,,,,, -w,,Lüftung = 135m³/h,Lüftung = 135m³/h,,,,1500c201,,,,,, -w,,Lüftung = 140m³/h,Lüftung = 140m³/h,,,,1500d201,,,,,, -w,,Lüftung = 145m³/h,Lüftung = 145m³/h,,,,1500e301,,,,,, -w,,Lüftung = 150m³/h,Lüftung = 150m³/h,,,,1500f401,,,,,, -w,,Lüftung = 155m³/h,Lüftung = 155m³/h,,,,15000402,,,,,, -w,,Lüftung = 160m³/h,Lüftung = 160m³/h,,,,15001502,,,,,, -w,,Lüftung = 165m³/h,Lüftung = 165m³/h,,,,15002602,,,,,, -w,,Lüftung = 170m³/h,Lüftung = 170m³/h,,,,15003602,,,,,, -w,,Lüftung = 175m³/h,Lüftung = 175m³/h,,,,15004702,,,,,, -w,,Lüftung = 180m³/h,Lüftung = 180m³/h,,,,15005802,,,,,, -w,,Lüftung = 185m³/h,Lüftung = 185m³/h,,,,15006802,,,,,, -w,,Lüftung = 190m³/h,Lüftung = 190m³/h,,,,15007902,,,,,, -w,,Lüftung = 195m³/h,Lüftung = 195m³/h,,,,15008a02,,,,,, -w,,Lüftung = 200m³/h,Lüftung = 200m³/h,,,,15009a02,,,,,, -w,,Lüftung = 205m³/h,Lüftung = 205m³/h,,,,1500ab02,,,,,, -w,,Lüftung = 210m³/h,Lüftung = 210m³/h,,,,1500bc02,,,,,, -w,,Lüftung = 215m³/h,Lüftung = 215m³/h,,,,1500cc02,,,,,, -w,,Lüftung = 220m³/h,Lüftung = 220m³/h,,,,1500dd02,,,,,, -w,,Lüftung = 225m³/h,Lüftung = 225m³/h,,,,1500ee02,,,,,, -w,,Lüftung = 230m³/h,Lüftung = 230m³/h,,,,1500fe02,,,,,, -w,,Lüftung = 235m³/h,Lüftung = 235m³/h,,,,15000f03,,,,,, -w,,Lüftung = 240m³/h,Lüftung = 240m³/h,,,,15002003,,,,,, -w,,Lüftung = 245m³/h,Lüftung = 245m³/h,,,,15003003,,,,,, -w,,Lüftung = 250m³/h,Lüftung = 250m³/h,,,,15004103,,,,,, -w,,Lüftung = 255m³/h,Lüftung = 255m³/h,,,,15005203,,,,,, -w,,Lüftung = 260m³/h,Lüftung = 260m³/h,,,,15006203,,,,,, -w,,Lüftung = 265m³/h,Lüftung = 265m³/h,,,,15007303,,,,,, -w,,Lüftung = 270m³/h,Lüftung = 270m³/h,,,,15008403,,,,,, -w,,Lüftung = 275m³/h,Lüftung = 275m³/h,,,,15009403,,,,,, -w,,Lüftung = 280m³/h,Lüftung = 280m³/h,,,,1500a503,,,,,, -w,,Lüftung = 285m³/h,Lüftung = 285m³/h,,,,1500b603,,,,,, -w,,Lüftung = 290m³/h,Lüftung = 290m³/h,,,,1500c603,,,,,, -w,,Lüftung = 295m³/h,Lüftung = 295m³/h,,,,1500d703,,,,,, -w,,Lüftung = 300m³/h,Lüftung = 300m³/h,,,,1500e803,,,,,, +# wartosc do wymnozenia przez 3/10 +w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, +#r,,VolumeFlowAct,,,,,1500,,,UIN,,, #######Weitere #####,,,,,,,,,,,,, -r;w,,Soll-Volumenstromkorrektur,Soll-Volumenstromkorrektur,,,,2000,,,D1B,,, -r;w,,Waermerueckgewinnung,Waermerueckgewinnung,,,,0a00,,,UCH,1=an;2=aus,, +r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, +r;wi,,BypassValve,,,,,0a00,,,onoff,,, *r,,,,,,B509,29,,,IGN:2,,, -r;w,,TempInletAir_SAI,Temperatur Zuluft,,,,0100,,,temp,,, -r;w,,TempOutsideAir_SAO,Temperatur Aussenluft,,,,0200,,,temp,,, -r;w,,TempWasteAir_EAI,Temperatur Abluft,,,,0300,,,temp,,, -r;w,,TempOutgoingAir_EAO,Temperatur Fortluft,,,,0400,,,temp,,, -r;w,,Roomtemp,Zimmertemperatur,,,,0000,,,temp,,, -r;w,,Unterdruckschutz,Unterdruckschutz,,,,4700,,,UCH,1=an;0=aus,, -r;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,, +r;w,,SAI_temperature,Supply air temperature,,,,0100,,,temp,,, +r;w,,SAO_temperature,Outside air temperature,,,,0200,,,temp,,, +r;w,,EAI_temperature,Exhaust air temperature,,,,0300,,,temp,,, +r;w,,EAO_temperature,Extract air temperature,,,,0400,,,temp,,, +r;w,,room_temperature,,,,,0000,,,temp,,, +r;w,,FrostProtection,,,,,4700,,,onoff,,, +r;w,,YieldTotal,,,,,4d00,,,UIN,,kWh, From 65d2a85ae4671a88569907b39476b8e2f08f47f2 Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 3 Feb 2022 17:47:20 +0100 Subject: [PATCH 04/11] Update 15.vai00.csv --- ebusd-2.1.x/en/vaillant/15.vai00.csv | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/ebusd-2.1.x/en/vaillant/15.vai00.csv b/ebusd-2.1.x/en/vaillant/15.vai00.csv index 2bda64aeb..530f0a69f 100644 --- a/ebusd-2.1.x/en/vaillant/15.vai00.csv +++ b/ebusd-2.1.x/en/vaillant/15.vai00.csv @@ -3,6 +3,6 @@ # ##### Generell #####,,,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, *w,,,,,,B509,0F,,,,,, -r;w,,Lüftungsstufe,Lüftungsstufe,,,,2400,,,UCH,1=Tag;2=Aus;3=Auto;5=Nacht,, -r;w,,Lüftung_HI,Lüftung_HI,,,,5800,,,BCD:2,,, -r,,Uhrzeit,Uhrzeit,,,,2C00,,,VTI,,, +r;w,,VentType,,,,,2400,,,UCH,1=Day;2=Out;3=Auto;5=Night,, +r;w,,VentHI,Wietrzenie,,,,5800,,,BCD:2,,, +r,,Time,,,,,2C00,,,VTI,,, From a3695e9e0fcf3743320d3fd0707162321f8be6a7 Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 3 Feb 2022 18:20:46 +0100 Subject: [PATCH 05/11] Update c0.wtw04.csv --- ebusd-2.1.x/en/vaillant/c0.wtw04.csv | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv index 67a4105a0..6772040a7 100644 --- a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -3,8 +3,7 @@ ############ Luftvolumen################,,,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, *w,,,,,,B509,0E,,,,,, -# wartosc do wymnozenia przez 3/10 -w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, +w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, wartosc do wymnozenia przez 3/10 #r,,VolumeFlowAct,,,,,1500,,,UIN,,, #######Weitere #####,,,,,,,,,,,,, r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, From 2bee1b6cfbe5bd441343d5f11fe3d1f161d1e8eb Mon Sep 17 00:00:00 2001 From: wedr0wycz Date: Fri, 4 Feb 2022 01:28:20 +0100 Subject: [PATCH 06/11] wi to w --- ebusd-2.1.x/en/vaillant/c0.wtw04.csv | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv index 6772040a7..bda75d80e 100644 --- a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -7,7 +7,7 @@ w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, wartosc do wymnozenia prz #r,,VolumeFlowAct,,,,,1500,,,UIN,,, #######Weitere #####,,,,,,,,,,,,, r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, -r;wi,,BypassValve,,,,,0a00,,,onoff,,, +r;w,,BypassValve,,,,,0a00,,,onoff,,, *r,,,,,,B509,29,,,IGN:2,,, r;w,,SAI_temperature,Supply air temperature,,,,0100,,,temp,,, r;w,,SAO_temperature,Outside air temperature,,,,0200,,,temp,,, From b2c6f40c55682f4d73f9374219f37c95bbc9ce71 Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Fri, 4 Feb 2022 16:32:32 +0100 Subject: [PATCH 07/11] Update 15.vai00.csv --- ebusd-2.1.x/en/vaillant/15.vai00.csv | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-) diff --git a/ebusd-2.1.x/en/vaillant/15.vai00.csv b/ebusd-2.1.x/en/vaillant/15.vai00.csv index 530f0a69f..7f1150b04 100644 --- a/ebusd-2.1.x/en/vaillant/15.vai00.csv +++ b/ebusd-2.1.x/en/vaillant/15.vai00.csv @@ -1,8 +1,9 @@ # type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment #,recov,RecoVair 275,,,,,,,,,,, -# ##### Generell #####,,,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, *w,,,,,,B509,0F,,,,,, -r;w,,VentType,,,,,2400,,,UCH,1=Day;2=Out;3=Auto;5=Night,, +*wi,#install,,,,,B509,0F,,,,,, +# ##### general #####,,,,,,,,,,,,, +r;w,,VentMode,,,,,2400,,,UCH,1=Day;2=Out;3=Auto;5=Night,, r;w,,VentHI,Wietrzenie,,,,5800,,,BCD:2,,, r,,Time,,,,,2C00,,,VTI,,, From c3fba2d336f89c00e54108a143ff572361dbc3ce Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 10 Feb 2022 13:47:14 +0100 Subject: [PATCH 08/11] new records from fhem/hasenhirn --- ebusd-2.1.x/en/vaillant/15.vai00.csv | 2 ++ 1 file changed, 2 insertions(+) diff --git a/ebusd-2.1.x/en/vaillant/15.vai00.csv b/ebusd-2.1.x/en/vaillant/15.vai00.csv index 7f1150b04..9886da17d 100644 --- a/ebusd-2.1.x/en/vaillant/15.vai00.csv +++ b/ebusd-2.1.x/en/vaillant/15.vai00.csv @@ -6,4 +6,6 @@ # ##### general #####,,,,,,,,,,,,, r;w,,VentMode,,,,,2400,,,UCH,1=Day;2=Out;3=Auto;5=Night,, r;w,,VentHI,Wietrzenie,,,,5800,,,BCD:2,,, +r;w,,Waermerueckgewinnung,Waermerueckgewinnung,,,,0a00,,,UCH,1=An;2=Aus,,,, +r,,Waermerueckgewinnung_Tage,Waermerueckgewinnung_Tage,,,,3600,,,,,,,, r,,Time,,,,,2C00,,,VTI,,, From e1eaf6526aa03ea91cf5040ac583a44ac38c70bc Mon Sep 17 00:00:00 2001 From: wedr0wycz <98967693+wedr0wycz@users.noreply.github.com> Date: Thu, 10 Feb 2022 13:58:45 +0100 Subject: [PATCH 09/11] update from fhem/hasenhirn --- ebusd-2.1.x/en/vaillant/c0.wtw04.csv | 13 +++++++------ 1 file changed, 7 insertions(+), 6 deletions(-) diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv index bda75d80e..eacb7d4a1 100644 --- a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -1,18 +1,19 @@ # type (r[1-9] w u ),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment #,recov,RecoVair 275,,,,,,,,,,, -############ Luftvolumen################,,,,,,,,,,,,, +# ########### general ################,,,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, *w,,,,,,B509,0E,,,,,, +r;w,,BypassValve,,,,,0a00,,,onoff,,, +r;w,,FrostProtection,,,,,4700,,,onoff,,, +r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, +r;w,,room_temperature,,,,,0000,,,temp,,, w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, wartosc do wymnozenia przez 3/10 #r,,VolumeFlowAct,,,,,1500,,,UIN,,, -#######Weitere #####,,,,,,,,,,,,, -r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, -r;w,,BypassValve,,,,,0a00,,,onoff,,, +####### #####,,,,,,,,,,,,, *r,,,,,,B509,29,,,IGN:2,,, +*w,,,,,,B509,,,,,,, r;w,,SAI_temperature,Supply air temperature,,,,0100,,,temp,,, r;w,,SAO_temperature,Outside air temperature,,,,0200,,,temp,,, r;w,,EAI_temperature,Exhaust air temperature,,,,0300,,,temp,,, r;w,,EAO_temperature,Extract air temperature,,,,0400,,,temp,,, -r;w,,room_temperature,,,,,0000,,,temp,,, -r;w,,FrostProtection,,,,,4700,,,onoff,,, r;w,,YieldTotal,,,,,4d00,,,UIN,,kWh, From 97dd5236ca3677daaa006361cc23389bedf525df Mon Sep 17 00:00:00 2001 From: "mikopp@gmail.com" Date: Sun, 27 Apr 2025 11:06:23 +0200 Subject: [PATCH 10/11] I have a working version for both the recovair 275 and its remote control. * The Vent Volume is really a RPM value but the remote or system forces specific values and shows cubic meters. So the definition makes that east * The system sets cooling or bypass and not the inverse heat recovery * I tested the german version (english is copy paste) so please use that as the master if possible * I tested all items of remote control (vai) and can change mode and cooling days via a loxone automation, it works nicely * I tested the read items in wtw and they all work. writing works, however this gets immediately overwritten by the remote control and thus only makes sense if remote control is not there * As I have a working system I can answer questions and am happy to test things * John, we can also switch to german ... I'm from Austria --- ebusd-2.1.x/de/vaillant/15.vai00.csv | 10 ++++++++ ebusd-2.1.x/de/vaillant/c0.wtw04.csv | 31 ++++++++++++++++++++++++ ebusd-2.1.x/en/vaillant/15.vai00.csv | 15 ++++++------ ebusd-2.1.x/en/vaillant/c0.wtw04.csv | 35 +++++++++++++++++----------- 4 files changed, 71 insertions(+), 20 deletions(-) create mode 100644 ebusd-2.1.x/de/vaillant/15.vai00.csv create mode 100644 ebusd-2.1.x/de/vaillant/c0.wtw04.csv diff --git a/ebusd-2.1.x/de/vaillant/15.vai00.csv b/ebusd-2.1.x/de/vaillant/15.vai00.csv new file mode 100644 index 000000000..aadb8e4c9 --- /dev/null +++ b/ebusd-2.1.x/de/vaillant/15.vai00.csv @@ -0,0 +1,10 @@ +# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275 Fernbedienung,,,,,,,,,,, +*r,,,,,,B509,0D,,,,,, +*w,,,,,,B509,0E,,,,,, +r9;w,,Lueftungsstufe,Lüftungsstufe,,,,2400,,,UCH,1=Tag;2=Aus;3=Auto;5=Nacht,, +r;w,,Lueftung_HI,Lüftung_HI,,,,5800,,,HCD:2,,, +# Writing works but seems to have no effect, might be pass through to RecoVair itself +r9;w,,Kuehlung,Kühlung - Sommer Bypass,,,,0a00,,,UCH,1=AUS;2=EIN,,,, +r9;w,,Kuehlung_Tage,Kühlung Tage,,,,3600,,,UCH,,,,, +r,,Uhrzeit,Uhrzeit,,,,2C00,,,VTI,,, diff --git a/ebusd-2.1.x/de/vaillant/c0.wtw04.csv b/ebusd-2.1.x/de/vaillant/c0.wtw04.csv new file mode 100644 index 000000000..cfc4e5a57 --- /dev/null +++ b/ebusd-2.1.x/de/vaillant/c0.wtw04.csv @@ -0,0 +1,31 @@ +# type (r[1-9] w u ),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275,,,,,,,,,,, +############ Luftvolumen################,,,,,,,,,,,,, +*r,,,,,c0,B509,0D,,,,,, +*w,,,,,c0,B509,0E,,,,,, +r;w,,Lueftungsvolumen,Lueftung m³/h,,,,1500,,,UIN,166=50;183=55;200=60;216=65;233=70;250=75;266=80;283=85;300=90;316=95;333=100;350=105;366=110;383=115;400=120;416=125;433=130;450=135;466=140;483=145;500=150;516=155;533=160;550=165;566=170;583=175;600=180;616=185;633=190;650=195;666=200;683=205;700=210;716=215;733=220;750=225;766=230;783=235;800=240;816=245;833=250;850=255;866=260;883=265;900=270,m³/h, +r;w,,SollVolumenstromkorrektur,Soll-Volumenstromkorrektur,,,,2000,,,D1B,,, +r9;w,,Kuehlung,Sommer bypass,,,,0a00,,,UCH,1=AUS;2=EIN,, +r;w,,Lueftung_HI,Lüftung_HI,,,,5800,,,HCD:2,,, +#29 seems to ask for info/status information +*r,,,,,c0,B509,29,,,IGN:2,,,first 2 bytes in response are the ID field again +r9,,BypassStellung,BypassStellung,,,,0900,,,percent0,,, +r1,,TempInletAir_SAI,Temperatur Aussenluft,,,,0100,,,temp,,°C, +r1,,TempOutsideAir_SAO,Temperatur Zuluft (Bypass),,,,0200,,,temp,,°C, +r1,,TempWasteAir_EAI,Temperatur Abluft,,,,0300,,,temp,,°C, +r1,,TempOutgoingAir_EAO,Temperatur Fortluft,,,,0400,,,temp,,°C, +# This is either wrong or room temp correction is missing +r1;w,,Roomtemp,Zimmertemperatur,,,,0000,,,temp;sensor,,°C, +#r1;w,,RoomTempOffset,Raumisttemp. Korrekturwert,,,,"1F00",,,temp,,, +#r1,,RoomTempOffsetSelfWarming,Offset Eigenerwärmung,,,,"2000",,,temp,,, +# other things +r;w,,Unterdruckschutz,Unterdruckschutz,,,,4700,,,UCH,1=AN;0=AUS,, +r;w,,Filter,Filter Tage,,,,4600,,,HCD:2,,, +#r;w,,UNKOWN_2,,,,,4300,,,,,,2 bytes +#r9;w,,UNKOWN_3,,,,,0e00,,,,,,1 byte, seems an on off, very often +#r9;w,,UNKOWN_3,,,,,0f00,,,,,,1 byte, seems an on off, very often +#r5;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,kW/h, +,,,,,,,,,,,,, +########### not working #################,,,,,,,,,,,,, +#r5;w,,Heatrecovery,Wärmerückgewinnung,,,,8c03,,,UCH,0=auto;1=on;2=off,,Aktuelle Uhrzeit +#r;w,,Desiredtemp,Wunschtemp,,,,140e,,,temp,,°C, diff --git a/ebusd-2.1.x/en/vaillant/15.vai00.csv b/ebusd-2.1.x/en/vaillant/15.vai00.csv index 9886da17d..139516fdd 100644 --- a/ebusd-2.1.x/en/vaillant/15.vai00.csv +++ b/ebusd-2.1.x/en/vaillant/15.vai00.csv @@ -1,11 +1,12 @@ # type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment -#,recov,RecoVair 275,,,,,,,,,,, +#,recov,RecoVair 275 remote control,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, -*w,,,,,,B509,0F,,,,,, -*wi,#install,,,,,B509,0F,,,,,, +*w,,,,,,B509,0E,,,,,, +#*wi,#install,,,,,B509,0F,,,,,, # ##### general #####,,,,,,,,,,,,, -r;w,,VentMode,,,,,2400,,,UCH,1=Day;2=Out;3=Auto;5=Night,, -r;w,,VentHI,Wietrzenie,,,,5800,,,BCD:2,,, -r;w,,Waermerueckgewinnung,Waermerueckgewinnung,,,,0a00,,,UCH,1=An;2=Aus,,,, -r,,Waermerueckgewinnung_Tage,Waermerueckgewinnung_Tage,,,,3600,,,,,,,, +r9;w,,VentMode,,,,,2400,,,UCH,1=Day;2=Off;3=Auto;5=Night,, +r;w,,VentHI,Ventilation High time,,,,5800,,,HCD:2,,, +#Writing works but seems to have no effect, might be pass through to RecoVair itself +r9;w,,Cooling,Cooling - Summer Bypass,,,,0a00,,,UCH,1=Off;2=On,,,, +r9;w,,Cooling_days,Days that the cooling is enabled,,,,3600,,,UCH,,,,, r,,Time,,,,,2C00,,,VTI,,, diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv index eacb7d4a1..2ee07508f 100644 --- a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -3,17 +3,26 @@ # ########### general ################,,,,,,,,,,,,, *r,,,,,,B509,0D,,,,,, *w,,,,,,B509,0E,,,,,, -r;w,,BypassValve,,,,,0a00,,,onoff,,, -r;w,,FrostProtection,,,,,4700,,,onoff,,, +r;w,,ventilation,ventilation level,,,,1500,,,UIN,166=50;183=55;200=60;216=65;233=70;250=75;266=80;283=85;300=90;316=95;333=100;350=105;366=110;383=115;400=120;416=125;433=130;450=135;466=140;483=145;500=150;516=155;533=160;550=165;566=170;583=175;600=180;616=185;633=190;650=195;666=200;683=205;700=210;716=215;733=220;750=225;766=230;783=235;800=240;816=245;833=250;850=255;866=260;883=265;900=270,m³/h, wartosc do wymnozenia przez 3/10 r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, -r;w,,room_temperature,,,,,0000,,,temp,,, -w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, wartosc do wymnozenia przez 3/10 -#r,,VolumeFlowAct,,,,,1500,,,UIN,,, -####### #####,,,,,,,,,,,,, -*r,,,,,,B509,29,,,IGN:2,,, -*w,,,,,,B509,,,,,,, -r;w,,SAI_temperature,Supply air temperature,,,,0100,,,temp,,, -r;w,,SAO_temperature,Outside air temperature,,,,0200,,,temp,,, -r;w,,EAI_temperature,Exhaust air temperature,,,,0300,,,temp,,, -r;w,,EAO_temperature,Extract air temperature,,,,0400,,,temp,,, -r;w,,YieldTotal,,,,,4d00,,,UIN,,kWh, +r9;w,,Cooling,Cooling - Summer Bypass,,,,0a00,,,UCH,1=Off;2=On,,,, +r;w,,VentHI,Ventilation High time,,,,5800,,,HCD:2,,, +#29 seems to ask for info/status information +*r,,,,,c0,B509,29,,,IGN:2,,,first 2 bytes in response are the ID field again +r9,,BypassValye,Bypass Position,,,,0900,,,percent0,,, +r1,,TempInletAir_SAI,Temperatur Aussenluft,,,,0100,,,temp,,°C, +r1,,TempOutsideAir_SAO,Temperatur Zuluft (Bypass),,,,0200,,,temp,,°C, +r1,,TempWasteAir_EAI,Temperatur Abluft,,,,0300,,,temp,,°C, +r1,,TempOutgoingAir_EAO,Temperatur Fortluft,,,,0400,,,temp,,°C, +# This is either wrong or room temp correction is missing +r1;w,,room_temperature,Room Temperature,,,,0000,,,temp;sensor,,°C, +#r1;w,,RoomTempOffset,Raumisttemp. Korrekturwert,,,,"1F00",,,temp,,, +#r1,,RoomTempOffsetSelfWarming,Offset Eigenerwärmung,,,,"2000",,,temp,,, +# Mike Kopp thinks this is "Unterdruckschutz +r;w,,FrostProtection,,,,,4700,,,onoff,,, +r;w,,Filter,Filter Days,,,,4600,,,HCD:2,,, +#r;w,,UNKOWN_2,,,,,4300,,,,,,2 bytes +#r9;w,,UNKOWN_3,,,,,0e00,,,,,,1 byte, seems an on off, very often +#r9;w,,UNKOWN_3,,,,,0f00,,,,,,1 byte, seems an on off, very often +#r5;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,kW/h, + From a398e9ef8613a746017a95d4ccfd30156f2c1165 Mon Sep 17 00:00:00 2001 From: mikopp Date: Sun, 4 May 2025 20:58:37 +0200 Subject: [PATCH 11/11] Found the settings for AIR1-AIR4, AIR HIGH and some others. Allowing autmation different air volumes even if remote is present --- ebusd-2.1.x/de/vaillant/15.vai00.csv | 8 ++++++++ 1 file changed, 8 insertions(+) diff --git a/ebusd-2.1.x/de/vaillant/15.vai00.csv b/ebusd-2.1.x/de/vaillant/15.vai00.csv index aadb8e4c9..843dc82ea 100644 --- a/ebusd-2.1.x/de/vaillant/15.vai00.csv +++ b/ebusd-2.1.x/de/vaillant/15.vai00.csv @@ -8,3 +8,11 @@ r;w,,Lueftung_HI,Lüftung_HI,,,,5800,,,HCD:2,,, r9;w,,Kuehlung,Kühlung - Sommer Bypass,,,,0a00,,,UCH,1=AUS;2=EIN,,,, r9;w,,Kuehlung_Tage,Kühlung Tage,,,,3600,,,UCH,,,,, r,,Uhrzeit,Uhrzeit,,,,2C00,,,VTI,,, +r;w,,Luftvolumen_High,Luftvolume in m3/h in Hi mode (HIGH),,,,4a00,,,UIN,,m3/h, +r;w,,Luftvolumen_minimum_Cool,Minimum Luftvolume in m3/h mit offenem Bypass (AIR5),,,,4800,,,UIN,,m3/h, +# not low something else +r;w,,Luftvolumen_Ferien,Luftvolume in m3/h im Ferien modus (AIR4),,,,4900,,,UIN,,m3/h, +r;w,,Luftvolumen_Nacht,Luftvolume in m3/h im Nacht modus (AIR1),,,,1800,,,UIN,,m3/h, +r;w,,Luftvolumen_Tag,Luftvolume in m3/h im Tag modus (AIR2),,,,1700,,,UIN,,m3/h, +r;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,kW/h, +r;w,,Alarm_Filter_FILT,Zeitraum zwischen 2 Alarmmeldungen fuer Filtertausch,,,,4500,,,UIN,,,