1. Segger Real Time Transfer (RTT)

  • Prerequisite is a processor with memory background access support like ARM Cortex-M cores.
  • If you can use a Segger J-Link or an STM ST-Link debug probe (ST Microelectronics eval boards have it) this is an easy and fast way to use trice without any UART or other port.
  • Detailed description can be found in document UM08001_JLink.pdf in chapter 16 which is part of https://www.segger.com/downloads/jlink/#J-LinkSoftwareAndDocumentationPack.
  • Following examples are for Windows, but should work similar also on Linux and Darwin (MacOS).
  • The trice tool can use the Segger RTT protocol in different ways.
    • Hardware paths:
      • Use J-Link or J-Link OB (on-board). J-Link OB can be flashed to many ST Microelectronics evaluation boards (v2.0 link hardware) and for example also usable with NXP and Atmel. For that you can also use a spare STM32 evaluation board (10 EUR) with jumper changes and breakout wires.
      • Use ST-Link with gostlink. It uses only one USB endpoint so debugging and trice output in parallel is not possible.
      • Use some other Debug-Probe with target memory access (support welcome)
    • RTT channel selection (on target and on host)
      • RECOMMENDED:
        • trice l -p JLINK or shorter trice l for STM32F030R8 (default port is JLINK) starts in background a JLinkRTTLogger.exe which
          connects to J-Link and writes to a logfile which in turn is read by the trice tool. On exit the JLinkRTTLogger.exe is killed automatically.
          It expects a target sending messages over RTT channel 0 (other channels supported too).
          It is possible to start several instances on different channels as well as on different targets.
        • trice l -p STLINK starts in background a trice/third_party/goST/stRttLogger.exe which connects to J-Link and
          writes to a logfile which in turn is read by the trice tool. On exit the stRttLogger.exe is killed automatically.
          It expects a target sending messages over RTT channel 0 (other channels supported too).
          It is possible to start several instances on different channels as well as on different targets.
        • If you have the choice, prefer J-Link. It allows parallel debugging and trice output.
        • The full -args string is normally required and depends on the used device. Example: trice l -args="-Device STM32F070RB -if SWD -Speed 4000 -RTTChannel 0 -RTTSearchRanges 0x20000000_0x1000". Enter trice h -log and read info for -args switch:
        -args string
        Use to pass port specific parameters. The "default" value depends on the used port:
        port "COMn": default="", use "TARM" for a different driver. (For baud rate settings see -baud.)
        port "J-LINK": default="-Device STM32F030R8 -if SWD -Speed 4000 -RTTChannel 0 -RTTSearchRanges 0x20000000_0x1000",
                The -RTTSearchRanges "..." need to be written without extra "" and with _ instead of space.
                For args options see JLinkRTTLogger in SEGGER UM08001_JLink.pdf.
        port "ST-LINK": default="-Device STM32F030R8 -if SWD -Speed 4000 -RTTChannel 0 -RTTSearchRanges 0x20000000_0x1000",
                The -RTTSearchRanges "..." need to be written without extra "" and with _ instead of space.
                For args options see JLinkRTTLogger in SEGGER UM08001_JLink.pdf.
        port "BUFFER": default="0 0 0 0", Option for args is any byte sequence.
         (default "default")

2. J-Link option

  • Prerequisite is a SEGGER J-Link debug probe or a development board with an on-board J-Link option.

2.1. Convert a STM NUCLEO or DISCOVERY onboard ST-Link (valid for ST-Link v2 & v2.1, not for v3)

Following steps describe the needed action for a ST Microelectronics evaluation board and windows - adapt them to your environment.

2.1.1. First step (to do if some issues occur - otherwise you can skip it)

  • Get & install STM32 ST-LINK utility
  • Run from default install location "C:\Program Files (x86)\STMicroelectronics\STM32 ST-LINKUtility\ST-LINK Utility\ST-LinkUpgrade.exe")
  • Enable checkbox Change Type and select radio button STM32 Debug+Mass storage + VCP. The STM32Debug+ VCP won´t be detected by Segger reflash utility. ST-LINK-Upgrade.PNG

2.1.2. Second step

2.2. Some SEGGER tools in short

  • JLink.exe is the SEGGER J-Link commander. It starts the J-Link driver/server and the trice tool can connect to it:

    • Example:
      • Compile and flash ../test/MDK-ARM_LL_UART_RTT0_FLEX_STM32F030R8-NUCLEO-64 project

      • Open a commandline and run (for a different device add the -args switch with configuration):

        trice log -p JLINK
      • trice output is visible

      • With halt and go inside the Jlink window the MCU can get haltes and released

      • It is possible in parallel to debug-step with a debugger (tested with ARM-MDK)

  • PLUS:

  • works reliable

  • trice can connect over TCP localhost:19021 and display logs over RTT channel 0

  • MINUS:

  • Uses RTT up-channel 0 and therefore RTT up-channel 0 is not usable differently

  • No down-channel usable

  • JLinkRTTLogger.exe is usable for writing RTT channel N data from target into a file. The trice tool can watch this file and display them.

    • PLUS:

      • Can use RTT up-channel 0,1,2,...
      • Can run in several instances for the same target each on a different channel
    • MINUS:

      • Needs a running J-Link driver/server
      • Logs in a file, so trice needs to read from that file
      • ...
    • UNKNOWN:

      • If several instances can watch on different RTT channels and all goes in parallel to debugging.
    • TESTED:

      • Create file

      /c/Program\ Files\ (x86)/SEGGER/JLink/JLinkRTTLogger.exe -Device STM32F030R8 -if SWD -Speed 4000 -RTTChannel 0 triceRaw.log

      • Play file with -device RTTF
  • JLinkRTTClient.exe can be used for simple text transmitting to the target, it also displays strings from target coming over channel 0. It is not used by the trice tool.

    • PLUS:
      • target stimulation with proprietary protocol over RTT down-channel 0 possible
    • MINUS:
      • Unfortunately it cannot run separately parallel to stimulate the target with any proprietary protocol.

3. Software Setup example (JLinkRTTViewer.exe is depreciated, use JLink.exe instead!)

  • Build and flash ../test/MDK-ARM_LL_UART_RTT0_PACK_STM32F030R8-NUCLEO-64
  • In the SeggerRTT example projects you see how to setup.

4. Segger RTT

  • The main advantage here is, that no triceServe() nor any interrupt is needed in the background, because this job is automatically done by SeggerRTT. This way one can debug code as comfortable as with printf() but with all the TRICE advantages. Have a look here: SeggerRTTD.gif

5. Segger RTT unbuffered (PC side receiver -device=JLINK)

  • Avoid trice buffering inside target and write with TRICE macro directly into the RTT buffer

  • Write the bytes per trace directly (little time & some space overhead on target, but no changes on host side) - this is implemented as test example.

    triceBlockDiagramWithSeggerRTT.svg

6. Segger J-Link SDK (~800 EUR) Option

  • Segger offers a SeggerRTT SDK which allows to use more than just channel 0 and you can develop your own tooling with it.
  • The trice -port JLINK is ok for usage as is right now. However if you wish more comfort check here:
  • Question: How-to-access-multiple-RTT-channels
    • "Developer pack used to write your own program for the J-Link. Please be sure you agree to the terms of the associated license found on the Licensing Information tab before purchasing this SDK. You will benefit from six months of free email support from the time that this product is ordered."
    • https://www.segger.com/products/debug-probes/j-link/technology/j-link-sdk/

7. Additional Notes (leftovers)

  • Downloading RTT target package from https://www.segger.com/products/debug-probes/j-link/technology/about-real-time-transfer/.
  • Read the manual "C:\Program Files (x86)\SEGGER\JLink\Doc\Manuals\UM08001_JLink.pdf".
  • Extract "C:\Program Files (x86)\SEGGER\JLink\Samples\RTT\SEGGER_RTT_V672b.zip" to target project. Check for an update @ SEGGER.
  • Add SEGGER_RTTI.c to target project
  • Put into main(): char* s = "Hi5!\n"; SEGGER_RTT_Write(0, s, strlen(s));, compile & flash image
  • Start "C:\Program Files (x86)\SEGGER\JLink\JLinkRTTViewer.exe" & connect.
  • Reset target & Hi5! should be visible inside viewer window.
  • Now Hi5! should be visible inside terminal window when resetting target board.
  • Instead of "C:\Program Files (x86)\SEGGER\JLink\JLinkRTTViewer.exe" also "C:\Program Files (x86)\SEGGER\JLink\JLink.exe" could be started & then https://github.com/stalehd/jlinklogviewer.
  • What also works: "C:\Program Files (x86)\SEGGER\JLink\JLink.exe" followed by a terminal program like TeraTerm connected to localhost:19021.
  • https://github.com/stalehd/jlinklogviewer is integrated into the trice tool (-port JLINK option)

8. Further development

  • The GoST project offers a way around JLINK. Used -port STLINK instead.

  • Maybe libusb together with libjaylink offer some options too.

  • Checkout https://github.com/deadsy/jaylink.

  • "C:\Program Files (x86)\SEGGER\JLink\JMem.exe" shows a memory dump.

  • Go to https://libusb.info/

    • -> Downloads -> Latest Windows Binaries
    • extract libusb-1.0.23 (or later version)
libusb-1.0.23\examples\bin64> .\listdevs.exe
2109:2811 (bus 2, device 8) path: 6
1022:145f (bus 1, device 0)
1022:43d5 (bus 2, device 0)
0a12:0001 (bus 2, device 1) path: 13
1366:0105 (bus 2, device 10) path: 5
  • Repeat without connected Segger JLink
libusb-1.0.23\examples\bin64> .\listdevs.exe
2109:2811 (bus 2, device 8) path: 6
1022:145f (bus 1, device 0)
1022:43d5 (bus 2, device 0)
0a12:0001 (bus 2, device 1) path: 13
  • In this case 1366:0105 (bus 2, device 10) path: 5 is missing, so vid=1366, did=0105 as example
  • On Windows install WSL2. The real Linux kernel is needed for full USB access.