Using the AutoTunePID Library

The AutoTunePID library is a powerful tool for adaptive PID control in Arduino projects. It features automatic tuning based on methods like Ziegler-Nichols, Cohen-Coon, IMC, Tyreus-Luyben, and Lambda Tuning (CLD), as well as manual tuning options. This guide provides a detailed explanation of how to integrate and use the library effectively.


Table of Contents

  1. Initialization
  2. Setting the Setpoint
  3. Selecting the Tuning Method
  4. Manual Tuning
  5. Input and Output Filtering
  6. Anti-Windup
  7. Updating the Controller
  8. Retrieving PID Gains and Output
  9. Auto-Tuning Behavior
  10. Operational Modes
  11. Oscillation Modes
  12. Example Sketches
  13. Summary of Methods

Initialization

To initialize the AutoTunePID controller, you need to specify the minimum and maximum output values for the PID controller. Additionally, you can define the tuning method, which defaults to ZieglerNichols.

Example

#include "AutoTunePID.h"

// Create an instance of AutoTunePID with a specified output range
AutoTunePID pidController(0, 255, TuningMethod::ZieglerNichols);

In this example, the pidController is configured to output values between 0 and 255 using the Ziegler-Nichols tuning method.


Setting the Setpoint

The setpoint represents the target value that the system aims to achieve. Use setSetpoint() to define it.

Example

pidController.setSetpoint(100.0); // Set the target value to 100

This sets the desired system state to a value of 100.


Selecting the Tuning Method

The tuning method determines how the PID gains are calculated. Use setTuningMethod() to choose one of the following options:

  • TuningMethod::ZieglerNichols: A popular method for process control.
  • TuningMethod::CohenCoon: Useful for processes with significant time delays.
  • TuningMethod::IMC: Balances robustness and response speed.
  • TuningMethod::TyreusLuyben: Minimizes overshoot and improves stability.
  • TuningMethod::LambdaTuning: Uses the Lambda Tuning (CLD) method for systems with dead time.
  • TuningMethod::Manual: For direct user-defined gains.

Example

pidController.setTuningMethod(TuningMethod::LambdaTuning);

This sets the tuning method to Lambda Tuning (CLD) for systems with significant dead time.


Manual Tuning

If you prefer manual tuning, set the PID gains directly using setManualGains().

Example

pidController.setManualGains(1.0, 0.5, 0.1); // Set Kp, Ki, and Kd

This allows precise control over the proportional, integral, and derivative gains.


Input and Output Filtering

Input and output filtering smoothens noisy signals, enhancing the controller's performance. Enable filtering and define a smoothing factor (alpha) between 0.01 and 1.0. Smaller values result in more smoothing.

  • enableInputFilter(alpha): Smooths the input signal.
  • enableOutputFilter(alpha): Smooths the output signal.

Example

pidController.enableInputFilter(0.2); // Apply input smoothing with alpha = 0.2
pidController.enableOutputFilter(0.3); // Apply output smoothing with alpha = 0.3

These functions improve stability in systems prone to noise.


Anti-Windup

Anti-windup prevents the integral term from accumulating excessively when the output is saturated. Use enableAntiWindup() to enable or disable this feature and set a threshold.

Example

pidController.enableAntiWindup(true, 0.8); // Enable anti-windup with 80% threshold

This ensures the integral term is constrained when the output approaches its limits.


Updating the Controller

The update() function processes the current input and calculates the appropriate output. Call it within the control loop.

Example

void loop() {
    float sensorValue = analogRead(A0); // Read sensor input
    pidController.update(sensorValue);

    float output = pidController.getOutput();
    analogWrite(3, output); // Send output to the actuator
}

This example continuously updates the PID output based on the sensor reading.


Retrieving PID Gains and Output

Retrieve the computed or manually set PID gains and the current output value:

  • getKp(), getKi(), getKd(): Access the proportional, integral, and derivative gains.
  • getOutput(): Access the controller's current output.
  • getKu(): Retrieve the ultimate gain (Ku) from auto-tuning.
  • getTu(): Retrieve the oscillation period (Tu) from auto-tuning.

Example

float kp = pidController.getKp();
float ki = pidController.getKi();
float kd = pidController.getKd();

Serial.print("Kp: "); Serial.println(kp);
Serial.print("Ki: "); Serial.println(ki);
Serial.print("Kd: "); Serial.println(kd);

This prints the current PID parameters to the Serial Monitor.


Auto-Tuning Behavior

When auto-tuning is enabled, the library uses one of the supported methods (e.g., Ziegler-Nichols, Cohen-Coon, IMC, Tyreus-Luyben, or Lambda Tuning) to compute optimal gains. These gains are applied automatically after tuning completes.

Notes

  • Ensure the system can oscillate safely during the tuning process.
  • Adjust tuning duration and output limits to match your system's dynamics.

Operational Modes

The library supports multiple operational modes to adapt the PID controller's behavior based on the system's needs. Use setOperationalMode() to select one of the following modes:

  • Normal: Standard PID operation.
  • Reverse: Reverses the error calculation for cooling systems.
  • Hold: Stops all calculations to save resources.
  • Preserve: Minimal calculations to keep the system responsive.
  • Tune: Performs auto-tuning to determine Tu and Ku.
  • Auto: Automatically selects the best operational mode based on system behavior.

Example

pidController.setOperationalMode(OperationalMode::Tune); // Set mode to Tune for auto-tuning

This sets the operational mode to Tune, enabling auto-tuning.


Oscillation Modes

The library supports three oscillation modes for auto-tuning, which determine the amplitude of the oscillations during the tuning process:

  • Normal: Full oscillation (MaxOutput - MinOutput).
  • Half: Half oscillation (1/2 MaxOutput - 1/2 MinOutput).
  • Mild: Mild oscillation (1/4 MaxOutput - 1/4 MinOutput).

You can also set the number of oscillation steps for auto-tuning. The default steps for each mode are:

  • Normal: 10 steps.
  • Half: 20 steps.
  • Mild: 40 steps.

Example

pidController.setOscillationMode(OscillationMode::Half); // Set oscillation mode to Half
pidController.setOscillationSteps(15); // Set custom oscillation steps (default is 20 for Half mode)

This sets the oscillation mode to Half and overrides the default steps to 15.


Example Sketches

1. Ziegler-Nichols Example: Temperature Control

#include "AutoTunePID.h"
AutoTunePID tempController(0, 255, TuningMethod::ZieglerNichols);

void setup() {
    tempController.setSetpoint(75.0); // Target temperature
    tempController.enableInputFilter(0.1); // Enable input filtering
    tempController.enableAntiWindup(true, 0.8); // Enable anti-windup
    tempController.setOscillationMode(OscillationMode::Normal); // Set oscillation mode to Normal
    tempController.setOperationalMode(OperationalMode::Tune); // Set operational mode to Tune
}

void loop() {
    float temp = readTemperature(); // Read temperature sensor
    tempController.update(temp); // Update PID controller
    analogWrite(HEATER_PIN, tempController.getOutput()); // Control heater
    delay(100);
}

2. Cohen-Coon Example: Motor Speed Control

#include "AutoTunePID.h"
AutoTunePID motorController(0, 255, TuningMethod::CohenCoon);

void setup() {
    motorController.setSetpoint(1500); // Target RPM
    motorController.enableInputFilter(0.2); // Enable input filtering
    motorController.enableAntiWindup(true, 0.7); // Enable anti-windup
    motorController.setOscillationMode(OscillationMode::Half); // Set oscillation mode to Half
    motorController.setOperationalMode(OperationalMode::Tune); // Set operational mode to Tune
}

void loop() {
    float rpm = readEncoderSpeed(); // Read motor speed
    motorController.update(rpm); // Update PID controller
    analogWrite(MOTOR_PIN, motorController.getOutput()); // Control motor
    delay(100);
}

3. IMC Example: Pressure Control

#include "AutoTunePID.h"
AutoTunePID pressureController(0, 255, TuningMethod::IMC);

void setup() {
    pressureController.setSetpoint(100.0); // Target pressure
    pressureController.enableInputFilter(0.1); // Enable input filtering
    pressureController.enableAntiWindup(true, 0.8); // Enable anti-windup
    pressureController.setOscillationMode(OscillationMode::Normal); // Set oscillation mode to Normal
    pressureController.setOperationalMode(OperationalMode::Tune); // Set operational mode to Tune
}

void loop() {
    float pressure = readPressureSensor(); // Read pressure sensor
    pressureController.update(pressure); // Update PID controller
    analogWrite(PUMP_PIN, pressureController.getOutput()); // Control pump
    delay(100);
}

4. Tyreus-Luyben Example: Chemical Reactor Temperature Control

#include "AutoTunePID.h"
AutoTunePID reactorController(0, 255, TuningMethod::TyreusLuyben);

void setup() {
    reactorController.setSetpoint(80.0); // Target reactor temperature
    reactorController.enableInputFilter(0.1); // Enable input filtering
    reactorController.enableAntiWindup(true, 0.8); // Enable anti-windup
    reactorController.setOscillationMode(OscillationMode::Half); // Set oscillation mode to Half
    reactorController.setOperationalMode(OperationalMode::Tune); // Set operational mode to Tune
}

void loop() {
    float temp = readReactorTemperature(); // Read reactor temperature
    reactorController.update(temp); // Update PID controller
    analogWrite(HEATER_PIN, reactorController.getOutput()); // Control heater
    delay(100);
}

5. Lambda Tuning Example: Flow Control

#include "AutoTunePID.h"
AutoTunePID flowController(0, 255, TuningMethod::LambdaTuning);

void setup() {
    flowController.setSetpoint(50.0); // Target flow rate
    flowController.enableInputFilter(0.15); // Enable input filtering
    flowController.enableAntiWindup(true, 0.9); // Enable anti-windup
    flowController.setOscillationMode(OscillationMode::Mild); // Set oscillation mode to Mild
    flowController.setOperationalMode(OperationalMode::Tune); // Set operational mode to Tune
}

void loop() {
    float flowRate = readFlowSensor(); // Read flow sensor
    flowController.update(flowRate); // Update PID controller
    analogWrite(VALVE_PIN, flowController.getOutput()); // Control valve
    delay(100);
}

Summary of Methods

Method Description
setSetpoint(float setpoint) Sets the target value for the PID controller.
setTuningMethod(TuningMethod) Selects the tuning method.
setManualGains(float kp, ki, kd) Sets PID gains manually.
enableInputFilter(float alpha) Enables input filtering with a smoothing factor.
enableOutputFilter(float alpha) Enables output filtering with a smoothing factor.
enableAntiWindup(bool, float) Enables anti-windup with an optional threshold.
update(float currentInput) Updates the PID controller with the current input.
getOutput() Retrieves the computed PID output.
getKp(), getKi(), getKd() Retrieves the PID gains.
getKu(), getTu() Retrieves the ultimate gain and oscillation period.
setOperationalMode(OperationalMode) Sets the operational mode.
setOscillationMode(OscillationMode) Sets the oscillation mode for auto-tuning.
setOscillationSteps(int steps) Sets the number of oscillation steps for auto-tuning.