Request support for EARU EAEMP3C-100-TY-W Smart Meter and Circuit Breaker 3-Phase #3003

Open
hemersonfds opened this issue Feb 24, 2025 · 0 comments
Labels
full_info All info needed was provided new device Unsupported device

Comments

@hemersonfds
Copy link

Log message

Este erro originou-se de uma integração personalizada.

Registrador: custom_components.tuya_local.config_flow
Fonte: custom_components/tuya_local/config_flow.py:421
integração: Tuya Local (documentação, problemas)
Ocorreu pela primeira vez: 23:36:00 (1 ocorrências)
Último registro: 23:36:00

Device matches earu_smart_wifi_circuit_breaker_with_energy_monitor with quality of 6%. DPS: {"updated_at": 1740364559.3010747, "1": 144542, "9": 0, "12": false, "13": 0, "15": 0, "16": true, "102": 30, "103": 41, "104": true, "105": 0, "106": "EwAAAAAAAAAAAA==", "107": 20, "109": "AAA8", "110": 0, "111": 1890, "112": 1, "118": 610, "119": 5, "120": 20, "121": 20, "122": 20, "123": 20, "124": 5, "125": 10, "127": "1", "128": "1", "129": "0", "131": 0, "132": 0, "133": 0, "134": "2", "135": 0, "136": 1, "137": 1}

Product ID

4x198rybhwtzirm7

Product Name

EARU EAEMP3C-100-TY-W 3-PHASE SMART METER AND CIRCUIT BREAKER

DPS information

{
  "result": {
    "model": "{\"modelId\":\"e1kbzgpg\",\"services\":[{\"actions\":[],\"code\":\"\",\"description\":\"\",\"events\":[],\"name\":\"\",\"properties\":[{\"abilityId\":1,\"accessMode\":\"ro\",\"code\":\"total_forward_energy\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"1152\"},\"name\":\"正向总有功电量\",\"typeSpec\":{\"type\":\"value\",\"max\":99999999,\"min\":0,\"scale\":2,\"step\":1,\"unit\":\"kW·h\"}},{\"abilityId\":6,\"accessMode\":\"ro\",\"code\":\"phase_a\",\"description\":\"1,A相电压,电流及功率\\n2,大端模式,HEX格式,共8个字节\\n3,单位精度:电压,2字节,单位0.1V。电流,3字节,单位 0.001A 。A相有功功率,3字节,单位0.0001kW\\n4,报文格式\\n举例:08 80 00 03 E8 00 27 10 表示A相217.6V,A相电流1.000A,A相功率10.000KW\\n5,通信逻辑:\\n1)用户进面板,主动查询。用户进入面板,面板马上下发0x08到电表,电表上报数据到云平台,面板拿到数据,然后展示。 注:最新WIFI支持。   \\n2)电表基于一定周期上报数据。建议:在WIFI模式时,15秒上报一次。NB模式时,1个小时上报一次。\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"1152\"},\"name\":\"A相电压,电流及功率\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":7,\"accessMode\":\"ro\",\"code\":\"phase_b\",\"description\":\"1,B相电压,电流及功率\\n2,大端模式,HEX格式,共8个字节\\n3,单位精度:电压,2字节,单位0.1V。电流,3字节,单位 0.001A 。B相有功功率,3字节,单位0.0001kW\\n4,报文格式\\n举例:08 80 00 03 E8 00 27 10 表示B相217.6V,B相电流1.000A,B相功率10.000KW\\n5,通信逻辑:\\n1)用户进面板,主动查询。用户进入面板,面板马上下发0x00到电表,电表上报数据到云平台,面板拿到数据,然后展示。    \\n2)电表基于一定周期上报数据。建议:在WIFI模式时,15秒上报一次。NB模式时,1个小时上报一次。\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"1152\"},\"name\":\"B相电压,电流及功率\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":8,\"accessMode\":\"ro\",\"code\":\"phase_c\",\"description\":\"1,C相电压,电流及功率\\n2,大端模式,HEX格式,共8个字节\\n3,单位精度:电压,2字节,单位0.1V。电流,3字节,单位 0.001A 。C相有功功率,3字节,单位0.0001kW\\n4,报文格式\\n举例:08 80 00 03 E8 00 27 10 表示C相217.6V,C相电流1.000A,C相功率10.000KW\\n5,通信逻辑:\\n1)用户进面板,主动查询。用户进入面板,面板马上下发0x08到电表,电表上报数据到云平台,面板拿到数据,然后展示。    \\n2)电表基于一定周期上报数据。建议:在WIFI模式时,15秒上报一次。NB模式时,1个小时上报一次。\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"1152\"},\"name\":\"C相电压,电流及功率\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":9,\"accessMode\":\"ro\",\"code\":\"fault\",\"description\":\"1,告警\\n2,大端模式,HEX,4字节\\n3,报文格式\\n按照完整4个字节,对应的告警位上报告警;bit位,1表示有告警,0表示无告警;如果没用的告警位,补0。高位无定义,也补0;\\n举例:0X00 00 00 09,表示当前发生了漏电自检不正常告警和短路告警,无其它告警。\\n4,通信逻辑\\n只要有1个告警发生,就完整4个字节上报给面板;只要有1个告警关闭,就完整4个字节上报给面板,更新面板显示。\",\"extensions\":{\"iconName\":\"icon-baojing\",\"scope\":\"fault\",\"attribute\":\"1152\"},\"name\":\"故障告警\",\"typeSpec\":{\"type\":\"bitmap\",\"label\":[\"short_circuit_alarm\",\"surge_alarm\",\"overload_alarm\",\"leakagecurr_alarm\",\"temp_dif_fault\",\"fire_alarm\",\"high_power_alarm\",\"self_test_alarm\",\"ov_cr\",\"unbalance_alarm\",\"ov_vol\",\"undervoltage_alarm\",\"miss_phase_alarm\",\"outage_alarm\",\"magnetism_alarm\",\"credit_alarm\",\"no_balance_alarm\",\"phase_seq_err_alarm\",\"vol_unbalance_alarm\",\"low_current_alarm\"],\"maxlen\":20}},{\"abilityId\":11,\"accessMode\":\"rw\",\"code\":\"switch_prepayment\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_money\",\"attribute\":\"1152\"},\"name\":\"预付费功能开关\",\"typeSpec\":{\"type\":\"bool\"}},{\"abilityId\":12,\"accessMode\":\"rw\",\"code\":\"clear_energy\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"1152\"},\"name\":\"剩余可用电量清零\",\"typeSpec\":{\"type\":\"bool\"}},{\"abilityId\":13,\"accessMode\":\"ro\",\"code\":\"balance_energy\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"1152\"},\"name\":\"剩余可用电量显示 (kWh)\",\"typeSpec\":{\"type\":\"value\",\"max\":99999999,\"min\":0,\"scale\":2,\"step\":1,\"unit\":\"kW·h\"}},{\"abilityId\":14,\"accessMode\":\"rw\",\"code\":\"charge_energy\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_money\",\"attribute\":\"1152\"},\"name\":\"电量充值\",\"typeSpec\":{\"type\":\"value\",\"max\":999999,\"min\":0,\"scale\":2,\"step\":1,\"unit\":\"kW·h\"}},{\"abilityId\":15,\"accessMode\":\"ro\",\"code\":\"leakage_current\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-power1\",\"attribute\":\"1152\"},\"name\":\"剩余电流显示\",\"typeSpec\":{\"type\":\"value\",\"max\":1000,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"mA\"}},{\"abilityId\":16,\"accessMode\":\"rw\",\"code\":\"switch\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_power2\",\"attribute\":\"1153\"},\"name\":\"断路器开关\",\"typeSpec\":{\"type\":\"bool\"}},{\"abilityId\":17,\"accessMode\":\"rw\",\"code\":\"alarm_set_1\",\"description\":\"1,告警阈值使能控制及设置2  \\n2,HEX格式,大端模式, 总告警的数量*4字节= 设置告警总长度。\\n3,报文格式\\n每个告警由4个字节组成,第1个字节(表示该告警存在);第2个字节(发生此告警时,断路器控制模式(0X01拉闸,0X00不动作只告警);第3、4字节:设置告警阈值\\n举例:0X01 01 00 00 03 01 00 14,表示该断路器支持短路告警,发生该告警时,自动跳闸,阀值补0。支持过载告警,发生该告警时,拉闸动作,动作阀值20KW。无其它告警。\\n4,通信逻辑\\nA,配网成功后,按照上面的格式,主动上报给云平台,面板知道哪些告警是断路器当前支持的。设置不成功,重新配网再上报。\\nB,断路器上电时,也上报一次。\\nC,面板根据协议下发告警设置。\",\"extensions\":{\"iconName\":\"icon-dp_warming\",\"attribute\":\"1152\"},\"name\":\"告警设置1\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":18,\"accessMode\":\"rw\",\"code\":\"alarm_set_2\",\"description\":\"1,告警阈值使能控制及设置2  \\n2,HEX格式,大端模式\\n3,报文格式\\n每个告警由4个字节组成,第1个字节(表示该告警存在);第2个字节(发生此告警时,断路器控制模式(0X01拉闸,0X00不动作只告警);第3、4字节:设置告警阈值\\n举例:0X01 01 00 3C 03 01 00 F5,表示该断路器支持过流告警,发生该告警时,拉闸动作,动作阀值60A。支持过压告警,发生该告警时,拉闸动作,动作阀值245V\\n4,通信逻辑\\nA,配网成功后,按照上面的格式,主动上报给云平台,面板知道哪些告警是断路器当前支持的。设置不成功,重新配网再上报。\\nB,断路器上电时,也上报一次。\\nC,面板根据协议下发告警设置。\",\"extensions\":{\"iconName\":\"icon-dp_warming\",\"attribute\":\"1152\"},\"name\":\"告警设置2\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":101,\"accessMode\":\"rw\",\"code\":\"recover_sec\",\"description\":\"\",\"name\":\"合闸恢复时间(弃用)\",\"typeSpec\":{\"type\":\"value\",\"max\":99,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"秒\"}},{\"abilityId\":102,\"accessMode\":\"rw\",\"code\":\"recover_cnt\",\"description\":\"\",\"name\":\"重合闸允许次数\",\"typeSpec\":{\"type\":\"value\",\"max\":30,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"次\"}},{\"abilityId\":103,\"accessMode\":\"ro\",\"code\":\"temp_current\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_c\",\"attribute\":\"4096\"},\"name\":\"当前温度\",\"typeSpec\":{\"type\":\"value\",\"max\":200,\"min\":-20,\"scale\":0,\"step\":1,\"unit\":\"℃\"}},{\"abilityId\":104,\"accessMode\":\"rw\",\"code\":\"recover_enable\",\"description\":\"\",\"name\":\"重合闸允许使能\",\"typeSpec\":{\"type\":\"bool\"}},{\"abilityId\":105,\"accessMode\":\"rw\",\"code\":\"countdown_1\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_time2\",\"attribute\":\"4096\"},\"name\":\"倒计时\",\"typeSpec\":{\"type\":\"value\",\"max\":86400,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":106,\"accessMode\":\"rw\",\"code\":\"cycle_time\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_time3\",\"attribute\":\"4096\"},\"name\":\"循环定时\",\"typeSpec\":{\"type\":\"string\",\"maxlen\":255}},{\"abilityId\":107,\"accessMode\":\"rw\",\"code\":\"leak_delay\",\"description\":\"\",\"name\":\"合闸恢复时间\",\"typeSpec\":{\"type\":\"value\",\"max\":99,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":108,\"accessMode\":\"rw\",\"code\":\"random_time\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_time2\",\"attribute\":\"4096\"},\"name\":\"随机定时\",\"typeSpec\":{\"type\":\"string\",\"maxlen\":255}},{\"abilityId\":109,\"accessMode\":\"rw\",\"code\":\"switch_inching\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_power2\",\"attribute\":\"4096\"},\"name\":\"点动开关(延时关)\",\"typeSpec\":{\"type\":\"string\",\"maxlen\":255}},{\"abilityId\":110,\"accessMode\":\"ro\",\"code\":\"reverse_energy_total\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"4096\"},\"name\":\"反向总有功电量\",\"typeSpec\":{\"type\":\"value\",\"max\":99999999,\"min\":0,\"scale\":2,\"step\":1,\"unit\":\"kW·h\"}},{\"abilityId\":111,\"accessMode\":\"ro\",\"code\":\"power_total\",\"description\":\"\",\"extensions\":{\"iconName\":\"icon-dp_lightning\",\"attribute\":\"4096\"},\"name\":\"总功率\",\"typeSpec\":{\"type\":\"value\",\"max\":900000,\"min\":0,\"scale\":3,\"step\":1,\"unit\":\"kW\"}},{\"abilityId\":112,\"accessMode\":\"ro\",\"code\":\"power_reactive\",\"description\":\"\",\"name\":\"Kvar.h\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":1,\"scale\":1,\"step\":1,\"unit\":\"Kvar\"}},{\"abilityId\":113,\"accessMode\":\"ro\",\"code\":\"pa_instant\",\"description\":\"数据内容:电压(2byte-0.1V),电流(3byte-0.001A)、有功功率(3byte-0.0001kw),无功功率(3byte-0.0001kvar),功率因数(2byte-0.001Pf),电网频率(2byte-0.00hz)\\n大端模式:hex格式,总共15个字节\",\"name\":\"A相电网详细数据\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":114,\"accessMode\":\"ro\",\"code\":\"pb_instant\",\"description\":\"数据内容:电压(2byte-0.1V),电流(3byte-0.001A)、有功功率(3byte-0.0001kw),无功功率(3byte-0.0001kvar),功率因数(2byte-0.001Pf),电网频率(2byte-0.00hz)\\n大端模式:hex格式,总共15个字节\",\"name\":\"B相电网详细数据\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":115,\"accessMode\":\"ro\",\"code\":\"pc_instant\",\"description\":\"数据内容:电压(2byte-0.1V),电流(3byte-0.001A)、有功功率(3byte-0.0001kw),无功功率(3byte-0.0001kvar),功率因数(2byte-0.001Pf),电网频率(2byte-0.00hz)\\n大端模式:hex格式,总共15个字节\",\"name\":\"C相电网详细信息\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":116,\"accessMode\":\"ro\",\"code\":\"energy_total\",\"description\":\"\",\"name\":\"总组合有功电能\",\"typeSpec\":{\"type\":\"value\",\"max\":999999,\"min\":1,\"scale\":3,\"step\":1,\"unit\":\"kwh\"}},{\"abilityId\":117,\"accessMode\":\"ro\",\"code\":\"energy_all\",\"description\":\"数据内容:总组合有功电能(4byte-0.01kwh),总正向有功电能(4-0.01kwh)、总反向有功电能(4-0.01kwh)\\n                  总组合无功电能(4byte-0.01kwh),总正向无功电能(4-0.01kwh)、总反向无功电能(4-0.01kwh)\\n\\t A相组合有功电能(4byte-0.01kwh),B相组合有功电能(4byte-0.01kwh),C相组合有功电能(4byte-0.01kwh)\\n大端模式:hex格式,总共 36字节\\n\",\"name\":\"电能详细数据\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":118,\"accessMode\":\"ro\",\"code\":\"power_factor\",\"description\":\"\",\"name\":\"功率因数\",\"typeSpec\":{\"type\":\"value\",\"max\":1000,\"min\":1,\"scale\":3,\"step\":1,\"unit\":\"pf\"}},{\"abilityId\":119,\"accessMode\":\"rw\",\"code\":\"power_on_delay\",\"description\":\"\",\"name\":\"上电延时通电时间\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":120,\"accessMode\":\"rw\",\"code\":\"alarm_v_delay\",\"description\":\"\",\"name\":\"过欠压事件恢复通电延时时间\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":121,\"accessMode\":\"rw\",\"code\":\"alarm_over_c_delay\",\"description\":\"\",\"name\":\"过流事件恢复上电延时时间\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":122,\"accessMode\":\"rw\",\"code\":\"alarm_low_c_delay\",\"description\":\"\",\"name\":\"失流事件恢复延时时间\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":123,\"accessMode\":\"rw\",\"code\":\"alam_v_cnt\",\"description\":\"\",\"name\":\"过欠压事件时间门限值\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":124,\"accessMode\":\"rw\",\"code\":\"alarm_over_c_cnt\",\"description\":\"\",\"name\":\"过流事件门限时间\",\"typeSpec\":{\"type\":\"value\",\"max\":999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":125,\"accessMode\":\"rw\",\"code\":\"alarm_low_c_cnt\",\"description\":\"\",\"name\":\"失流事件时间门限值\",\"typeSpec\":{\"type\":\"value\",\"max\":999,\"min\":1,\"scale\":0,\"step\":1,\"unit\":\"s\"}},{\"abilityId\":126,\"accessMode\":\"rw\",\"code\":\"alarm_set3\",\"description\":\"同告警设置1\",\"name\":\"告警设置3\",\"typeSpec\":{\"type\":\"raw\",\"maxlen\":128}},{\"abilityId\":127,\"accessMode\":\"ro\",\"code\":\"status\",\"description\":\"0.\\t不显示  1. 用电 。2 发电\",\"name\":\"状态\",\"typeSpec\":{\"type\":\"enum\",\"range\":[\"0\",\"1\",\"2\"]}},{\"abilityId\":128,\"accessMode\":\"ro\",\"code\":\"status_b\",\"description\":\"0.\\t不显示  1. 用电 。2 发电\",\"name\":\"状态\",\"typeSpec\":{\"type\":\"enum\",\"range\":[\"0\",\"1\",\"2\"]}},{\"abilityId\":129,\"accessMode\":\"ro\",\"code\":\"status_c\",\"description\":\"0.\\t不显示  1. 用电 。2 发电\",\"name\":\"状态\",\"typeSpec\":{\"type\":\"enum\",\"range\":[\"0\",\"1\",\"2\"]}},{\"abilityId\":130,\"accessMode\":\"ro\",\"code\":\"n_current\",\"description\":\"\",\"name\":\"零序电流\",\"typeSpec\":{\"type\":\"value\",\"max\":99999,\"min\":0,\"scale\":2,\"step\":1,\"unit\":\"A\"}},{\"abilityId\":131,\"accessMode\":\"ro\",\"code\":\"over_current_cnt\",\"description\":\"\",\"name\":\"过流次数\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"\"}},{\"abilityId\":132,\"accessMode\":\"ro\",\"code\":\"lost_current_cnt\",\"description\":\"\",\"name\":\"失流次数\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"\"}},{\"abilityId\":133,\"accessMode\":\"ro\",\"code\":\"leak_cnt\",\"description\":\"\",\"name\":\"漏电次数\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"\"}},{\"abilityId\":134,\"accessMode\":\"rw\",\"code\":\"swithc_power_save\",\"description\":\"0- OFF; 1-ON; 2-断电记忆\",\"name\":\"继电器上电状态设置\",\"typeSpec\":{\"type\":\"enum\",\"range\":[\"0\",\"1\",\"2\"]}},{\"abilityId\":135,\"accessMode\":\"rw\",\"code\":\"switch_delay\",\"description\":\"\",\"name\":\"开关延时\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"\"}},{\"abilityId\":136,\"accessMode\":\"rw\",\"code\":\"energy_pt\",\"description\":\"\",\"name\":\"电压倍率\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"\"}},{\"abilityId\":137,\"accessMode\":\"rw\",\"code\":\"energy_ct\",\"description\":\"\",\"name\":\"电流倍率\",\"typeSpec\":{\"type\":\"value\",\"max\":9999,\"min\":0,\"scale\":0,\"step\":1,\"unit\":\"\"}}]}]}"
  },
  "success": true,
  "t": 1740364435831,
  "tid": "cb3e3b70f25711ef9038422d1fbf5b4e"
}

Information about how the device functions

My product is not working properly. It even has a device type option, but the data is not loaded.

Below are some screenshots.

Image

Image

@hemersonfds hemersonfds added the new device Unsupported device label Feb 24, 2025
@make-all make-all moved this to 🔖 Ready in Tuya Local Feb 24, 2025
@make-all make-all added the full_info All info needed was provided label Feb 24, 2025