Logging and Performance Monitoring

The Shuriken library makes extensive use of the Event Tracing for Windows (ETW) for logging as well as for reporting performance.

Logging

The following table contains the explosed events:

Event Name Event ID Event Level Opcode Payload Message
MonitorStart 1 Informational Start Monitor has been started.
MonitorStop 2 Informational Stop Monitor has been stopped.
MonitorSuspend 3 Informational Suspend Monitor has been suspended.
MonitorResume 4 Informational Resume Monitor has been resumed.
StoppingDueToFailedUpdate 5 Error Info exception Stopping the monitoring because of an exception while updating the values: {0}
StoppingDueToFailedChangeNotifications 6 Error Info exception Stopping the monitoring because of an exception while sending the change notifications: {0}
FailedAttachingSystemEvent 7 Warning Info systemEvent, exception Failed attaching the system event '{0}': {1}
MissingMonitoringScope 8 Warning Info eventName, scope The {0} event handler is assigned, but the {1} is not available.
UnableInitiallyToReadProperty 9 Warning Info type, property, exception Cannot initially get the value of the '{1}' property of the '{0}' object: {2}
UnableSubsequentlyToReadProperty 10 Warning Info type, property, exception Cannot get the value of the '{1}' property of the '{0}' object: {2}
UnableInitiallyToInvokeCommandMethod 11 Warning Info type, property, method, exception Cannot initially invoke the '{2}' method of the '{1}' property of the '{0}' object: {3}
UnableSubsequentlyToInvokeCommandMethod 12 Warning Info type, property, method, exception Cannot invoke the '{2}' method of the '{1}' property of the '{0}' object: {3}
UnableToAnalyzeProperty 13 Warning Info type, property, exception Cannot analyze the value of the '{1}' property of the '{0}' object: {2}
UnableToRaisePropertyChangeNotification 14 Warning Info type, property, exception Cannot raise the change notification for the '{1}' property of the '{0}' object: {2}
UnableToRaiseCommandPropertyChangeNotification 15 Warning Info type, property, exception Cannot raise the change notification for the '{1}' command property of the '{0}' object: {2}
CommandFailed 16 Warning Info exception Command execution failed: {0}

All logging events are traced to the Operational channel.

Measuring Performance

The following table contains the explosed events:

Event Name Event ID Payload Remarks
PerformanceMonitoredProperties 19 count Number of monitored properties. Lower value is better. A high value can indicate an unnecessary observation or memory leaks (e.g. due to missing UI virtualization).
PerformanceCycleTime 20 elapsedMilliseconds Complete cycle time [ms]. Lower value is better. For smooth performance it should not exceed 15ms.
PerformanceLists 21 capacityThreadAffine, countThreadAffine, capacityThreadSafe, countThreadSafe Total number and number of used slots.
PerformanceListsWithChangedProperties 22 capacityThreadAffine, countThreadAffine, capacityThreadSafe, countThreadSafe Total number and number of used slots with changed properties.
PerformanceListsWithItemsToBeRemoved 23 capacityThreadAffine, countThreadAffine, capacityThreadSafe, countThreadSafe Total number and number of used slots with items to be removed.

All performance-related events are traced to the Analytic channel.

Capturing Events from the Application

Use the static events of the Shuriken.Diagnostics.EventListener class to receive notifications when events are traced.

Using the Output Window in Visual Studio

Capture events from the Operational channel and create debug message using the ToDebugMessage extension method (also defined in the Shuriken.Diagnostics.EventListener class). Consider surrounding the tracing with the #if DEBUG directive when the event handler only invokes the Debug.WriteLine method:

[STAThread]
static void Main()
{
#if DEBUG
    Shuriken.Diagnostics.EventListener.OperationalEvent += (_, e) => Debug.WriteLine(e.ToDebugMessage());
#endif

    var app = new App();
    app.InitializeComponent();

    var applicationMonitorScope = new ApplicationMonitorScope(new WpfNotificationContext(app.Dispatcher));
    try
    {
        app.Run();
    }
    finally
    {
        applicationMonitorScope.Dispose().GetAwaiter().GetResult();
    }
}

Note: use this approach to be notified when observed properties, commands' CanExecute and Execute methods throw exceptions.