2024.6.30 -- Bugfix: Error submitting jobs with local forcefield files.
- 2024.6.29 -- Bugfix: factor of 2 for dihedrals and impropers in ligpargen
- The ligpargen tool was missing a factor of 2 in the dihedral and improper parameters.
- Corrected the search paths for forcefields.
- Improved the documentation.
- 2024.6.28 -- Added customizable local forcefields and LigParGen interface.
- Added the machinery to handle local forcefield files in either ~/.seamm.d/data/Forcefields (personal) or ~/SEAMM/data/Forcefields (site).
- Added 'ligpargen' command to access custom parameters from the LigParGen service at Yale University, ading them to the 'ligpargen.frc' personal forcefield, which is automatically included in 'oplsaa.frc' if it exists.
- 2024.1.10 -- Fixed PF6- issue in CL&P forcefield
- The angle parameters for PF6- in the CL&P forcefield only work if the 180º F-P-F angles are not included in the calculation. Replacing them with an equivalent periodic SHAPES-like potential almost works; however, since 0º is a valid angle and there are no 1-3 nonbonds, nothing keeps the F atoms apart. This is solved using a tabulated potential based on the SHAPES potential but with an added 1-3 repulsion large enough that the gradient is always pusing small angles apart, but not large enough to affect the minimum at 90º.
- 2023.9.14 -- Fixed errors! And added C2mim to test.
- The units of the torsions were incorrect in the last implementation.
- Added parameters for 1-alkyl-3-methylimidazolium cations from JCP 108, 2038 (2004)
- Tested much more thoroughly.
- 2023.9.13 -- Added parameters for TFSI to CL&P/OPLSAA
- Parameters for TFSI - bis[(trifluoromethyl)sulfonyl]imide
- 2023.9.8 -- Added more typing for OPLS-AA
- cyclopropane -CH2-, -CHR-, and -CR2-
- hexafluorobenzene
- difluorobenzene
- bromobenzene
- iodobenzene
- thiophenol
- alkyl nitriles
- nitroalkanes
- nitrobenzene
- methylene in phenylacetonitrile
- corrections to methylene nitrile anion
2023.9.7 -- Added typing in OPLS_AA for fluorobenzene
- 2023.9.6 -- Fixed issue with PF6- geometry
- The Lennard-Jones repulsive term added to the F-P-F angle was too weak, allowing the structure to get trapped in a symmetric state with ~40º angles.
- 2023.8.27 -- Fixed issue with angle in octahedral systems
- The SHAPES-type simple fourier potential used for octahedral complexes has a fals minimim at 0º. Added a LJ 1/R^12 repulsive term between the two end atoms of the angle to prevent small angles. This required using tabulated potentials in LAMMPS.
- 2023.5.1 -- Fixed bug in Lithium battery forcefield
- Fixed a typo in the angle type unit line which caused a crash
- 2023.4.6 -- Added Lithium battery forcefield
- An initial set of parameters for cathode materials, specifically LiCoO2.
- 2023.2.13 -- Added OPLS-AA forcefield
- Added parameters for OPLS-AA along with some extra parameters for ionic liquids * PF6- * ethylene carbonate (EC) and fluoronated EC (FEC)
- Added atom-typing templates for most of OPLS-AA. Still missing a few and amino acids and DNA not yet tested.
- Added extensive, almost-complete testing, for OPLS-AA
- Updated the README file to give a better description.
- Updated the short description in setup.py to work with the new installer.
- Added keywords for better searchability.
- Added support for OpenKIM potentials in LAMMPS
- Added the specialized NaCl_water forcefield for testing the MolSSI Driver Interface (MDI) metadynamics driver.
- Internal changes for compatibility