Serial Reader for Great Scale XK-3190-A9 version Weigher


HOW ?

  1. Connect PC to XK-3190-A9 with RS422 Cable (15 pins)
  2. Run this Program and determine Port to listen, Baud Rate (9600 is default for this XK- version), time out and decode method (latin-1 is tested for proper result).
  3. Press Start Listen button to open port and start to listen the streaming serial data.
  4. Once you want to capture and save the data from stream, just press Pick data button to write data on pdf file, do it for that time to capture and save weight data.
  5. If you want to stop streaming process, just click Stop Listen to close the port, ensure that you must to close the streaming process by press stop button before starting new streaming process.