import cc1101
import logging
from time import sleep
TXGPIO = 26
SYMBOL_BAUD = 3300
REPEAT_COUNT = 10
BUTTONS = {
'power': 0x84,
'light': 0x82,
'speed1': 0x90,
'speed2': 0x94,
'speed3': 0xa0,
'speed4': 0xb0,
'speed5': 0xc4,
'speed6': 0xc0,
}
logger = logging.getLogger('control_fan')
def encode_command(raw_command: int) -> bytes:
encoded_command = 0
for i in reversed(range(13)):
if (raw_command & (1 << i)):
encoded_command = (encoded_command << 3) | 0b101
else:
encoded_command = (encoded_command << 3) | 0b100
return encoded_command.to_bytes(5)
def send_command(command: bytes):
with cc1101.CC1101() as transceiver:
transceiver.set_base_frequency_hertz(433.92e6)
transceiver.set_sync_mode(cc1101.SyncMode.NO_PREAMBLE_AND_SYNC_WORD)
transceiver.set_packet_length_mode(cc1101.PacketLengthMode.FIXED)
transceiver.set_packet_length_bytes(5)
transceiver.disable_checksum()
transceiver.set_symbol_rate_baud(SYMBOL_BAUD)
transceiver.set_output_power((0, 0xC0))
for x in range(REPEAT_COUNT):
transceiver.transmit(command)
sleep(0.015)
def control_fan(fan_id: int, command: str):
command_id = BUTTONS.get(command)
if not command_id:
logger.error(f'Can\'t find command "{command}"')
return
logger.info(f'Executing command {command} on fan id {fan_id}')
fan_id = fan_id & 0b11111
raw_command = (fan_id << 8) | command_id
encoded_command = encode_command(raw_command)
logger.debug(f'Encoded command = {encoded_command.hex()}')
send_command(encoded_command)