Notifications
You must be signed in to change notification settings - Fork 0
/
sdfobject-power_control.swagger.json
144 lines (144 loc) · 4.1 KB
/
sdfobject-power_control.swagger.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
{
"swagger": "2.0",
"info": {
"title": "OMA/IPSO Power Control (Object ID 3312)",
"version": "2022-02-22",
"license": {
"name": "BSD-3-Clause",
"x-copyright": "Copyright 2019 Open Mobile Alliance."
}
},
"schemes": [
"http"
],
"consumes": [
"application/json"
],
"produces": [
"application/json"
],
"paths": {
"/Omaipsopowercontrolobjectid3312ResURI": {
"get": {
"description": " This Object is used to control a power source, such as a Smart Plug. It allows a power relay to be turned on or off and its dimmer setting to be control as a % between 0 and 100.",
"parameters": [
{
"$ref": "#/parameters/interface"
}
],
"responses": {
"200": {
"description": "",
"schema": {
"$ref": "#/definitions/Omaipsopowercontrolobjectid3312"
}
}
}
}
}
},
"parameters": {
"interface": {
"in": "query",
"name": "if",
"type": "string",
"enum": [
"oic.if.s",
"oic.if.baseline"
]
}
},
"definitions": {
"Omaipsopowercontrolobjectid3312": {
"properties": {
"rt": {
"description": "The Resource Type.",
"items": {
"enum": [
"oic.r.o.power.control"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"n": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/n"
},
"if": {
"description": "The OCF Interface set supported by this Resource.",
"items": {
"enum": [
"oic.if.s",
"oic.if.baseline"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"On_Off": {
"description": "On/off control. Boolean value where True is On and False is Off.",
"x-label": "On/Off",
"type": "boolean"
},
"Dimmer": {
"description": "This resource represents a dimmer setting, which has an Integer value between 0 and 100 as a percentage.",
"x-label": "Dimmer",
"maximum": 100,
"minimum": 0,
"type": "integer",
"x-unit": "/100"
},
"On_time": {
"description": "The time in seconds that the device has been on. Writing a value of 0 resets the counter.",
"x-label": "On time",
"type": "integer",
"x-unit": "s"
},
"Cumulative_active_power": {
"description": "The cumulative active power since the last cumulative energy reset or device start.",
"x-label": "Cumulative active power",
"type": "number",
"x-unit": "Wh",
"readOnly": true
},
"Power_factor": {
"description": "If applicable, the power factor of the current consumption.",
"x-label": "Power factor",
"type": "number",
"readOnly": true
},
"Application_Type": {
"description": "The application type of the sensor or actuator as a string depending on the use case.",
"x-label": "Application Type",
"type": "string"
},
"Timestamp": {
"description": "The timestamp of when the measurement was performed.",
"x-label": "Timestamp",
"x-sdfType": "unix-time",
"type": "number",
"readOnly": true
},
"Fractional_Timestamp": {
"description": "Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).",
"x-label": "Fractional Timestamp",
"maximum": 1,
"minimum": 0,
"type": "number",
"x-unit": "s",
"readOnly": true
}
},
"type": "object",
"required": [
"On_Off"
]
}
}
}