-
Notifications
You must be signed in to change notification settings - Fork 0
/
sdfobject-rate.swagger.json
169 lines (169 loc) · 5.84 KB
/
sdfobject-rate.swagger.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
{
"swagger": "2.0",
"info": {
"title": "OMA/IPSO Rate (Object ID 3346)",
"version": "2022-02-22",
"license": {
"name": "BSD-3-Clause",
"x-copyright": "Copyright 2019 Open Mobile Alliance."
}
},
"schemes": [
"http"
],
"consumes": [
"application/json"
],
"produces": [
"application/json"
],
"paths": {
"/Omaipsorateobjectid3346ResURI": {
"get": {
"description": " This object type should be used to report a rate measurement, for example the speed of a vehicle, or the rotational speed of a drive shaft. It also provides resources for minimum and maximum measured values, as well as the minimum and maximum range that can be measured by the sensor. An example measurement unit is meters per second (m/s).",
"parameters": [
{
"$ref": "#/parameters/interface"
}
],
"responses": {
"200": {
"description": "",
"schema": {
"$ref": "#/definitions/Omaipsorateobjectid3346"
}
}
}
}
}
},
"parameters": {
"interface": {
"in": "query",
"name": "if",
"type": "string",
"enum": [
"oic.if.s",
"oic.if.baseline"
]
}
},
"definitions": {
"Omaipsorateobjectid3346": {
"properties": {
"rt": {
"description": "The Resource Type.",
"items": {
"enum": [
"oic.r.o.rate"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"n": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/n"
},
"if": {
"description": "The OCF Interface set supported by this Resource.",
"items": {
"enum": [
"oic.if.s",
"oic.if.baseline"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"Sensor_Value": {
"description": "Last or Current Measured Value from the Sensor.",
"x-label": "Sensor Value",
"type": "number",
"readOnly": true
},
"Sensor_Units": {
"description": "Measurement Units Definition.",
"x-label": "Sensor Units",
"type": "string",
"readOnly": true
},
"Min_Measured_Value": {
"description": "The minimum value measured by the sensor since power ON or reset.",
"x-label": "Min Measured Value",
"type": "number",
"readOnly": true
},
"Max_Measured_Value": {
"description": "The maximum value measured by the sensor since power ON or reset.",
"x-label": "Max Measured Value",
"type": "number",
"readOnly": true
},
"Min_Range_Value": {
"description": "The minimum value that can be measured by the sensor.",
"x-label": "Min Range Value",
"type": "number",
"readOnly": true
},
"Max_Range_Value": {
"description": "The maximum value that can be measured by the sensor.",
"x-label": "Max Range Value",
"type": "number",
"readOnly": true
},
"Current_Calibration": {
"description": "Read or Write the current calibration coefficient.",
"x-label": "Current Calibration",
"type": "number"
},
"Application_Type": {
"description": "The application type of the sensor or actuator as a string depending on the use case.",
"x-label": "Application Type",
"type": "string"
},
"Timestamp": {
"description": "The timestamp of when the measurement was performed.",
"x-label": "Timestamp",
"x-sdfType": "unix-time",
"type": "number",
"readOnly": true
},
"Fractional_Timestamp": {
"description": "Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).",
"x-label": "Fractional Timestamp",
"maximum": 1,
"minimum": 0,
"type": "number",
"x-unit": "s",
"readOnly": true
},
"Measurement_Quality_Indicator": {
"description": "Measurement quality indicator reported by a smart sensor. 0: UNCHECKED No quality checks were done because they do not exist or can not be applied. 1: REJECTED WITH CERTAINTY The measured value is invalid. 2: REJECTED WITH PROBABILITY The measured value is likely invalid. 3: ACCEPTED BUT SUSPICIOUS The measured value is likely OK. 4: ACCEPTED The measured value is OK. 5-15: Reserved for future extensions. 16-23: Vendor specific measurement quality.",
"x-label": "Measurement Quality Indicator",
"maximum": 23,
"minimum": 0,
"type": "integer",
"readOnly": true
},
"Measurement_Quality_Level": {
"description": "Measurement quality level reported by a smart sensor. Quality level 100 means that the measurement has fully passed quality check algorithms. Smaller quality levels mean that quality has decreased and the measurement has only partially passed quality check algorithms. The smaller the quality level, the more caution should be used by the application when using the measurement. When the quality level is 0 it means that the measurement should certainly be rejected.",
"x-label": "Measurement Quality Level",
"maximum": 100,
"minimum": 0,
"type": "integer",
"readOnly": true
}
},
"type": "object",
"required": [
"Sensor_Value"
]
}
}
}