-
Notifications
You must be signed in to change notification settings - Fork 0
/
sdfobject-timer.swagger.json
150 lines (150 loc) · 4.83 KB
/
sdfobject-timer.swagger.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
{
"swagger": "2.0",
"info": {
"title": "OMA/IPSO Timer (Object ID 3340)",
"version": "2022-02-22",
"license": {
"name": "BSD-3-Clause",
"x-copyright": "Copyright 2019 Open Mobile Alliance."
}
},
"schemes": [
"http"
],
"consumes": [
"application/json"
],
"produces": [
"application/json"
],
"paths": {
"/Omaipsotimerobjectid3340ResURI": {
"get": {
"description": " This IPSO object is used to time events and actions, using patterns common to industrial timers. A write to the trigger resource or On/Off input state change starts the timing operation, and the timer remaining time shows zero when the operation is complete. The patterns supported are One-Shot (mode 1), On-Time or Interval (mode 2), Time delay on pick-up or TDPU (mode 3), and Time Delay on Drop-Out or TDDO (mode 4). Mode 0 disables the timer, so the output follows the input with no delay. A counter is provided to count occurrences of the timer output changing from 0 to 1. Writing a value of zero resets the counter. The Digital Input State resource reports the state of the timer output.",
"parameters": [
{
"$ref": "#/parameters/interface"
}
],
"responses": {
"200": {
"description": "",
"schema": {
"$ref": "#/definitions/Omaipsotimerobjectid3340"
}
}
}
}
}
},
"parameters": {
"interface": {
"in": "query",
"name": "if",
"type": "string",
"enum": [
"oic.if.s",
"oic.if.baseline"
]
}
},
"definitions": {
"Omaipsotimerobjectid3340": {
"properties": {
"rt": {
"description": "The Resource Type.",
"items": {
"enum": [
"oic.r.o.timer"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"n": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/n"
},
"if": {
"description": "The OCF Interface set supported by this Resource.",
"items": {
"enum": [
"oic.if.s",
"oic.if.baseline"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"Delay_Duration": {
"description": "The duration of the time delay.",
"x-label": "Delay Duration",
"type": "number",
"x-unit": "s"
},
"Remaining_Time": {
"description": "The time remaining in an operation.",
"x-label": "Remaining Time",
"type": "number",
"x-unit": "s",
"readOnly": true
},
"Minimum_Off-time": {
"description": "The duration of the rearm delay (i.e. the delay from the end of one cycle until the beginning of the next, the inhibit time).",
"x-label": "Minimum Off-time",
"type": "number",
"x-unit": "s"
},
"On_Off": {
"description": "On/off control. Boolean value where True is On and False is Off.",
"x-label": "On/Off",
"type": "boolean"
},
"Digital_Input_Counter": {
"description": "The cumulative value of active state detected.",
"x-label": "Digital Input Counter",
"type": "integer",
"readOnly": true
},
"Cumulative_Time": {
"description": "The total time in seconds that the timer input is true. Writing a 0 resets the time.",
"x-label": "Cumulative Time",
"type": "number",
"x-unit": "s"
},
"Digital_State": {
"description": "The current state of the timer output.",
"x-label": "Digital State",
"type": "boolean",
"readOnly": true
},
"Counter": {
"description": "Counts the number of times the timer output transitions from 0 to 1.",
"x-label": "Counter",
"type": "integer"
},
"Timer_Mode": {
"description": "Type of timer pattern used by the timer. 1: One-shot, 2: On-Time or Interval, 3: Time delay on pick-up, 4: Time Delay on Drop-Out, 0: disables the timer.",
"x-label": "Timer Mode",
"maximum": 4,
"minimum": 0,
"type": "integer"
},
"Application_Type": {
"description": "The application type of the sensor or actuator as a string depending on the use case.",
"x-label": "Application Type",
"type": "string"
}
},
"type": "object",
"required": [
"Delay_Duration"
]
}
}
}