-
Notifications
You must be signed in to change notification settings - Fork 3
/
Copy pathlsi.sh
292 lines (267 loc) · 12.3 KB
/
lsi.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
#!/bin/bash
#
#original script from:
# Calomel.org
# https://calomel.org/megacli_lsi_commands.html
# LSI MegaRaid CLI
# lsi.sh @ Version 0.05
#
# description: MegaCLI script to configure and monitor LSI raid cards.
# extended for moz internal use by David Joslin
# test for root - DJ
if [[ $EUID -ne 0 ]]; then
echo "This script must be run as root" 1>&2
exit 1
fi
if [ -e /usr/bin/aptitude ]; then
APT=/usr/bin/aptitude
elif [ -e /usr/bin/apt ]; then
APT=/usr/bin/apt
else
echo "can't find apt or aptitude" 1>&2
exit 1
fi
# Full path to the MegaRaid CLI binary - base on moz install - DJ
MegaCli="/usr/sbin/megacli"
# check if installed, install if not - DJ
if [ ! -e $MegaCli ]; then
CODENAME=`grep CODENAME /etc/lsb-release |cut -d"=" -f2`
echo "deb http://hwraid.le-vert.net/ubuntu $CODENAME main" >> /etc/apt/sources.list
wget -O - http://hwraid.le-vert.net/debian/hwraid.le-vert.net.gpg.key | sudo apt-key add -
$APT update
$APT -y install megacli megactl
fi
# The identifying number of the enclosure. Default for our systems is "8". Use
# "MegaCli64 -PDlist -a0 | grep "Enclosure Device"" to see what your number
# is and set this variable.
# Programatically define enclosure - DJ
ENCLOSURE=`$MegaCli -PDlist -a0|grep "Enclosure Device ID:"|head -n1|cut -d" " -f4`
if [ $# -eq 0 ]
then
echo ""
echo " OBPG .:. lsi.sh $arg1 $arg2"
echo "-----------------------------------------------------"
echo "status = Status of Virtual drives (volumes)"
echo "drives = Status of hard drives"
echo "ident \$slot = Blink light on drive (need slot number)"
echo "good \$slot = Simply makes the slot \"Unconfigured(good)\" (need slot number)"
echo "replace \$slot = Replace \"Unconfigured(bad)\" drive (need slot number)"
echo "progress = Status of drive rebuild"
echo "errors = Show drive errors which are non-zero"
echo "bat = Battery health and capacity"
echo "batrelearn = Force BBU re-learn cycle"
echo "logs = Print card logs"
echo "checkNemail = Check volume(s) and send email on raid errors"
echo "allinfo = Print out all settings and information about the card"
echo "settime = Set the raid card's time to the current system time"
echo "setdefaults = Set preferred default settings for new raid setup"
echo ""
exit
fi
# General status of all RAID virtual disks or volumes and if PATROL disk check
# is running.
if [ $1 = "status" ]
then
$MegaCli -LDInfo -Lall -aALL -NoLog
echo "###############################################"
$MegaCli -AdpPR -Info -aALL -NoLog
echo "###############################################"
$MegaCli -LDCC -ShowProg -LALL -aALL -NoLog
exit
fi
# Shows the state of all drives and if they are online, unconfigured or missing.
# if [ $1 = "drives" ]
# then
# $MegaCli -PDlist -aALL -NoLog | egrep 'Slot|state' | awk '/Slot/{if (x)print x;x="";}{x=(!x)?$0:x" -"$0;}END{print x;}' | sed 's/Firmware state://g'
# exit
# fi
# format drives output to be similar to megasasctl - DJ
if [ $1 = "drives" ] || [ $1 = "disks" ]
then
printf "%-8s | %-6s | %-10s | %-15s | %-30s\n" "Disk" "Errors" "SMART Err" "Type" "DISKGROUP"
FILE="/tmp/megacli_out"
$MegaCli -PDlist -aALL -NoLog > $FILE
for DRIVE in $(grep ^Slot $FILE|cut -d" " -f3); do
sed -n -e "/Slot Number: $DRIVE$/,/Enclosure Device ID:/ p" $FILE|sed -e '$d' > $FILE"_DRIVE_"$DRIVE
ERRORS=`grep Count: $FILE"_DRIVE_"$DRIVE|awk '{sum+=$4} END {print sum}'`
SMART=`grep S.M.A $FILE"_DRIVE_"$DRIVE|awk '{print $NF}'`
TYPE=`grep ^Firmware $FILE"_DRIVE_"$DRIVE| cut -d' ' -f3-`
if [ "$TYPE" != "JBOD" ]; then
DISKGROUP=`grep DiskGroup $FILE"_DRIVE_"$DRIVE| cut -d' ' -f3-`
else
DISKGROUP="n/a"
fi
printf "%-8s | %-6s | %-10s | %-15s | %-30s\n" "Slot $DRIVE" "$ERRORS" "$SMART" "$TYPE" "$DISKGROUP"
rm $FILE"_DRIVE_"$DRIVE
done
rm $FILE
exit
fi
# Use to blink the light on the slot in question. Hit enter again to turn the blinking light off.
if [ $1 = "ident" ]
then
$MegaCli -PdLocate -start -physdrv[$ENCLOSURE:$2] -a0 -NoLog
logger "`hostname` - identifying enclosure $ENCLOSURE, drive $2 "
read -p "Press [Enter] key to turn off light..."
$MegaCli -PdLocate -stop -physdrv[$ENCLOSURE:$2] -a0 -NoLog
exit
fi
# When a new drive is inserted it might have old RAID headers on it. This
# method simply removes old RAID configs from the drive in the slot and make
# the drive "good." Basically, Unconfigured(bad) to Unconfigured(good). We use
# this method on our FreeBSD ZFS machines before the drive is added back into
# the zfs pool.
if [ $1 = "good" ]
then
# set Unconfigured(bad) to Unconfigured(good)
$MegaCli -PDMakeGood -PhysDrv[$ENCLOSURE:$2] -a0 -NoLog
# clear 'Foreign' flag or invalid raid header on replacement drive
$MegaCli -CfgForeign -Clear -aALL -NoLog
exit
fi
# Use to diagnose bad drives. When no errors are shown only the slot numbers
# will print out. If a drive(s) has an error you will see the number of errors
# under the slot number. At this point you can decided to replace the flaky
# drive. Bad drives might not fail right away and will slow down your raid with
# read/write retries or corrupt data.
if [ $1 = "errors" ]
then
echo "Slot Number: 0"; $MegaCli -PDlist -aALL -NoLog | egrep -i 'error|fail|slot' | egrep -v ' 0'
exit
fi
# status of the battery and the amount of charge. Without a working Battery
# Backup Unit (BBU) most of the LSI read/write caching will be disabled
# automatically. You want caching for speed so make sure the battery is ok.
if [ $1 = "bat" ]
then
$MegaCli -AdpBbuCmd -aAll -NoLog
exit
fi
# Force a Battery Backup Unit (BBU) re-learn cycle. This will discharge the
# lithium BBU unit and recharge it. This check might take a few hours and you
# will want to always run this in off hours. LSI suggests a battery relearn
# monthly or so. We actually run it every three(3) months by way of a cron job.
# Understand if your "Current Cache Policy" is set to "No Write Cache if Bad
# BBU" then write-cache will be disabled during this check. This means writes
# to the raid will be VERY slow at about 1/10th normal speed. NOTE: if the
# battery is new (new bats should charge for a few hours before they register)
# or if the BBU comes up and says it has no charge try powering off the machine
# and restart it. This will force the LSI card to re-evaluate the BBU. Silly
# but it works.
if [ $1 = "batrelearn" ]
then
$MegaCli -AdpBbuCmd -BbuLearn -aALL -NoLog
exit
fi
# Use to replace a drive. You need the slot number and may want to use the
# "drives" method to show which drive in a slot is "Unconfigured(bad)". Once
# the new drive is in the slot and spun up this method will bring the drive
# online, clear any foreign raid headers from the replacement drive and set the
# drive as a hot spare. We will also tell the card to start rebuilding if it
# does not start automatically. The raid should start rebuilding right away
# either way. NOTE: if you pass a slot number which is already part of the raid
# by mistake the LSI raid card is smart enough to just error out and _NOT_
# destroy the raid drive, thankfully.
if [ $1 = "replace" ]
then
logger "`hostname` - REPLACE enclosure $ENCLOSURE, drive $2 "
# set Unconfigured(bad) to Unconfigured(good)
$MegaCli -PDMakeGood -PhysDrv[$ENCLOSURE:$2] -a0 -NoLog
# clear 'Foreign' flag or invalid raid header on replacement drive
$MegaCli -CfgForeign -Clear -aALL -NoLog
# set drive as hot spare
$MegaCli -PDHSP -Set -PhysDrv [$ENCLOSURE:$2] -a0 -NoLog
# show rebuild progress on replacement drive just to make sure it starts
$MegaCli -PDRbld -ShowProg -PhysDrv [$ENCLOSURE:$2] -a0 -NoLog
exit
fi
# Print all the logs from the LSI raid card. You can grep on the output.
if [ $1 = "logs" ]
then
$MegaCli -FwTermLog -Dsply -aALL -NoLog
exit
fi
# Use to query the RAID card and find the drive which is rebuilding. The script
# will then query the rebuilding drive to see what percentage it is rebuilt and
# how much time it has taken so far. You can then guess-ti-mate the
# completion time.
if [ $1 = "progress" ]
then
DRIVE=`$MegaCli -PDlist -aALL -NoLog | egrep 'Slot|state' | awk '/Slot/{if (x)print x;x="";}{x=(!x)?$0:x" -"$0;}END{print x;}' | sed 's/Firmware state://g' | egrep build | awk '{print $3}'`
$MegaCli -PDRbld -ShowProg -PhysDrv [$ENCLOSURE:$DRIVE] -a0 -NoLog
exit
fi
# Use to check the status of the raid. If the raid is degraded or faulty the
# script will send email to the address in the $EMAIL variable. We normally add
# this method to a cron job to be run every few hours so we are notified of any
# issues.
if [ $1 = "checkNemail" ]
then
EMAIL="raidadmin@localhost"
# Check if raid is in good condition
STATUS=`$MegaCli -LDInfo -Lall -aALL -NoLog | egrep -i 'fail|degrad|error'`
# On bad raid status send email with basic drive information
if [ "$STATUS" ]; then
$MegaCli -PDlist -aALL -NoLog | egrep 'Slot|state' | awk '/Slot/{if (x)print x;x="";}{x=(!x)?$0:x" -"$0;}END{print x;}' | sed 's/Firmware state://g' | mail -s `hostname`' - RAID Notification' $EMAIL
fi
fi
# Use to print all information about the LSI raid card. Check default options,
# firmware version (FW Package Build), battery back-up unit presence, installed
# cache memory and the capabilities of the adapter. Pipe to grep to find the
# term you need.
if [ $1 = "allinfo" ]
then
$MegaCli -AdpAllInfo -aAll -NoLog
exit
fi
# Update the LSI card's time with the current operating system time. You may
# want to setup a cron job to call this method once a day or whenever you
# think the raid card's time might drift too much.
if [ $1 = "settime" ]
then
$MegaCli -AdpGetTime -aALL -NoLog
$MegaCli -AdpSetTime `date +%Y%m%d` `date +%H:%M:%S` -aALL -NoLog
$MegaCli -AdpGetTime -aALL -NoLog
exit
fi
# These are the defaults we like to use on the hundreds of raids we manage. You
# will want to go through each option here and make sure you want to use them
# too. These options are for speed optimization, build rate tweaks and PATROL
# options. When setting up a new machine we simply execute the "setdefaults"
# method and the raid is configured. You can use this on live raids too.
if [ $1 = "setdefaults" ]
then
# Read Cache enabled specifies that all reads are buffered in cache memory.
$MegaCli -LDSetProp -Cached -LAll -aAll -NoLog
# Adaptive Read-Ahead if the controller receives several requests to sequential sectors
$MegaCli -LDSetProp ADRA -LALL -aALL -NoLog
# Hard Disk cache policy enabled allowing the drive to use internal caching too
$MegaCli -LDSetProp EnDskCache -LAll -aAll -NoLog
# Write-Back cache enabled
$MegaCli -LDSetProp WB -LALL -aALL -NoLog
# Continue booting with data stuck in cache. Set Boot with Pinned Cache Enabled.
$MegaCli -AdpSetProp -BootWithPinnedCache -1 -aALL -NoLog
# PATROL run every 672 hours or monthly (RAID6 77TB @60% rebuild takes 21 hours)
$MegaCli -AdpPR -SetDelay 672 -aALL -NoLog
# Check Consistency every 672 hours or monthly
$MegaCli -AdpCcSched -SetDelay 672 -aALL -NoLog
# Enable autobuild when a new Unconfigured(good) drive is inserted or set to hot spare
$MegaCli -AdpAutoRbld -Enbl -a0 -NoLog
# RAID rebuild rate to 60% (build quick before another failure)
$MegaCli -AdpSetProp \{RebuildRate -60\} -aALL -NoLog
# RAID check consistency rate to 60% (fast parity checks)
$MegaCli -AdpSetProp \{CCRate -60\} -aALL -NoLog
# Enable Native Command Queue (NCQ) on all drives
$MegaCli -AdpSetProp NCQEnbl -aAll -NoLog
# Sound alarm disabled (server room is too loud anyways)
$MegaCli -AdpSetProp AlarmDsbl -aALL -NoLog
# Use write-back cache mode even if BBU is bad. Make sure your machine is on UPS too.
$MegaCli -LDSetProp CachedBadBBU -LAll -aAll -NoLog
# Disable auto learn BBU check which can severely affect raid speeds
OUTBBU=$(mktemp /tmp/output.XXXXXXXXXX)
echo "autoLearnMode=1" > $OUTBBU
$MegaCli -AdpBbuCmd -SetBbuProperties -f $OUTBBU -a0 -NoLog
rm -rf $OUTBBU
exit
fi
### EOF ###