We read every piece of feedback, and take your input very seriously.
To see all available qualifiers, see our documentation.
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
We deployed 6.1.0 on SH in Splunk Cloud. I replicated config from my sandbox instance, which works fine. In Splunk Cloud it terminates with exception:
04/01/2022 04:22:58.679 2022-01-04 04:22:58,679 DEBUG pid=32448 tid=MainThread file=geoipupdate.py:stream_events:242 | Modular input completed 04/01/2022 04:22:58.679 2022-01-04 04:22:58,679 INFO pid=32448 tid=MainThread file=geoipupdate.py:stream_events:236 | Completed Request 04/01/2022 04:22:58.675 NameError: name 'CalledProcessError' is not defined 04/01/2022 04:22:58.675 except CalledProcessError as e: 04/01/2022 04:22:58.675 File "/opt/splunk/etc/apps/SecKit_SA_geolocation/bin/SecKit_SA_geolocation_rh_updater.py", line 124, in post_update 04/01/2022 04:22:58.675 Traceback (most recent call last): 04/01/2022 04:22:58.675 During handling of the above exception, another exception occurred: 04/01/2022 04:22:58.675 subprocess.CalledProcessError: Command '['$SPLUNK_HOME/etc/apps/SecKit_SA_geolocation/bin/geoipupdate/linux_amd64/geoipupdate -v -d /opt/splunk/etc/apps/SecKit_SA_geolocation/data/ -f /tmp/GeoIPk0dr5sqd.conf']' returned non-zero exit status 1. 04/01/2022 04:22:58.675 output=stdout, stderr=stderr) 04/01/2022 04:22:58.675 File "/opt/splunk/lib/python3.7/subprocess.py", line 512, in run 04/01/2022 04:22:58.675 **kwargs).stdout 04/01/2022 04:22:58.675 File "/opt/splunk/lib/python3.7/subprocess.py", line 411, in check_output 04/01/2022 04:22:58.675 stderr=subprocess.STDOUT, 04/01/2022 04:22:58.675 File "/opt/splunk/etc/apps/SecKit_SA_geolocation/bin/SecKit_SA_geolocation_rh_updater.py", line 122, in post_update 04/01/2022 04:22:58.675 Traceback (most recent call last): 04/01/2022 04:22:58.675 2022-01-04 04:22:58,675 ERROR pid=32459 tid=MainThread file=SecKit_SA_geolocation_rh_updater.py:post_update:157 | Exception generated when attempting to backup a lookup file 04/01/2022 04:22:57.741 2022-01-04 04:22:57,741 INFO pid=32459 tid=MainThread file=SecKit_SA_geolocation_rh_updater.py:post_update:82 | Trying to update 04/01/2022 04:22:57.741 2022-01-04 04:22:57,741 INFO pid=32459 tid=MainThread file=SecKit_SA_geolocation_rh_updater.py:post_update:77 | Asked to update id=xxxxxx token=XXXXXXXXXXXXX db=GeoLite2-Country GeoLite2-City GeoLite2-ASN 04/01/2022 04:22:57.741 2022-01-04 04:22:57,741 INFO pid=32459 tid=MainThread file=SecKit_SA_geolocation_rh_updater.py:post_update:76 | Asked to update <seckit_helpers.rest_handler.RequestInfo object at 0x7f2599c95810> 04/01/2022 04:22:57.741 2022-01-04 04:22:57,741 INFO pid=32459 tid=MainThread file=SecKit_SA_geolocation_rh_updater.py:post_update:74 | Asked to update
The text was updated successfully, but these errors were encountered:
No branches or pull requests
We deployed 6.1.0 on SH in Splunk Cloud. I replicated config from my sandbox instance, which works fine. In Splunk Cloud it terminates with exception:
The text was updated successfully, but these errors were encountered: