Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsungrow-dbus.py
executable file
·286 lines (221 loc) · 10.1 KB
/
sungrow-dbus.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
#!/usr/bin/env python3
"""
A class to put a simple service on the dbus, according to victron standards, with constantly updating
paths. See example usage below. It is used to generate dummy data for other processes that rely on the
dbus. See files in dbus_vebus_to_pvinverter/test and dbus_vrm/test for other usage examples.
To change a value while testing, without stopping your dummy script and changing its initial value, write
to the dummy data via the dbus. See example.
https://github.com/victronenergy/dbus_vebus_to_pvinverter/tree/master/test
"""
from gi.repository import GLib
import platform
import argparse
import logging
import sys
import os
import dbus
# our own packages
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '../ext/velib_python'))
sys.path.insert(1, '/opt/victronenergy')
sys.path.insert(1, '/opt/victronenergy/dbus-mqtt/ext/velib_python/')
from vedbus import VeDbusService
from pymodbus.client.sync import ModbusTcpClient
log = logging.getLogger(__name__)
def twos_comp(val, bits=16):
"""compute the 2's complement of int value val"""
if (val & (1 << (bits - 1))) != 0: # if sign bit is set e.g., 8bit: 128-255
val = val - (1 << bits) # compute negative value
return val
def read(client, addr, n=1):
reg = client.read_input_registers(addr-1,n,unit=1).registers
reg = list(map(twos_comp, reg))
if n == 1:
reg = reg[0]
return reg
def roundu(v, n, unit):
'''
Convert value to string with n significant digits and add unit string to the end
'''
v = round(v,n) #+ unit
return v
# Need to make independent system busses otherwise you can't have multiple devices per process
# https://community.victronenergy.com/questions/46675/venus-os-driver-for-fronius-smart-meter.html
class SystemBus(dbus.bus.BusConnection):
def __new__(cls):
return dbus.bus.BusConnection.__new__(cls, dbus.bus.BusConnection.TYPE_SYSTEM)
class Reg:
def __init__(self, path, address):
pass
class SungrowProduct:
def __init__(self, client, productname, servicename, deviceinstance):
self._dbusservice = VeDbusService(servicename, bus=SystemBus())
self._client = client
self._paths = []
self._interval_ms = 1000
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
connection=str(self._client)
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/FirmwareVersion', 0)
self._dbusservice.add_path('/HardwareVersion', 0)
productid = 0
connected = 0
try:
productid=self.read(5000)
connected = 1
except:
log.info('not connected')
productid = 0
connected = 0
self._dbusservice.add_path('/ProductId', productid)
self._dbusservice.add_path('/Connected', connected)
GLib.timeout_add(self._interval_ms, self._update_robust)
def __iadd__(self, d):
path = d[0]
initial_value= 0
self._dbusservice.add_path(path, initial_value)
return self
def read(self, addr, n=1):
return read(self._client, addr, n)
def _update_robust(self):
log.debug('Update robust')
with self._dbusservice as s:
try:
self._update(s)
s['/Connected'] = 1
except:
log.exception('Exception doing update')
s['/Connected'] = 0
GLib.timeout_add(self._interval_ms, self._update_robust)
class SungrowInverter(SungrowProduct):
def __init__(self, client, servicename, deviceinstance):
super().__init__(client, 'Sungrow Inverter', servicename, deviceinstance)
# Fixed values
maxpower = 10 # self.read(XXX)
self._dbusservice.add_path('/Ac/MaxPower', maxpower)
position = 0 # where it's connected to the inverter. 0=AC input 1; 1=AC output; 2=AC input 2
self._dbusservice.add_path('/Position', position)
self += '/Ac/Energy/Forward', 'kWh', 5004 #Total produced energy over all phases = Total power yields
self += '/Ac/Power', 'W', 5009 # Total apparent power
# self += '/Ac/PowerLimit', 'W' # writeable # TODO
self += '/StatusCode', ''
self += '/FroniusDeviceType',''
for phase in range (0,3):
p = phase + 1
self += f'/Ac/L{p}/Current', 'A AC', 5022+phase, 0.1
self += f'/Ac/L{p}/Energy/Forward', 'kWh'
self += f'/Ac/L{p}/Power', 'W'
self += f'/Ac/L{p}/Voltage', 'V AC', 5019+phase, 0.1
#for path, settings in self._paths.items():
# self._dbusservice.add_path(
# path, settings['initial'], writeable=True, onchangecallback=self._handlechangedvalue)
self.phase_energies = [0,0,0]
def _update(self, s):
interval_sec = self._interval_ms/1000.0
# HEY KB - for some reason the power in venus doesn't marry up with - basically anything in the Winet GUI
# check this as it may be lying to us?!
s['/Ac/Power'] = roundu(self.read(5031),1,'W')
s['/Ac/Energy/Forward'] = roundu(self.read(5004),1,'kWHr')
d = self.read(5019, 6)
for phase in range(3):
p = phase + 1
v = d[phase]*0.1 # Volts
i = d[phase + 3]*0.1 # Amps
phase_power = v * i # W
self.phase_energies[phase] += phase_power * interval_sec/3600.0/1000 # kWh
s[f'/Ac/L{p}/Voltage'] = roundu(v, 1,'V')
s[f'/Ac/L{p}/Current'] = roundu(i, 1,'A')
s[f'/Ac/L{p}/Power'] = roundu(phase_power, 1,'W')
s[f'/Ac/L{p}/Energy/Forward'] = roundu(self.phase_energies[phase],1,'kWHr')
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
class SungrowMeter(SungrowProduct):
def __init__(self, client, servicename, deviceinstance):
super().__init__(client, 'Sungrow Meter', servicename, deviceinstance)
# Fixed values
self._dbusservice.add_path('/DeviceType', 'Internal meter')
self += '/Ac/Energy/Forward', 'kWh', 5004 # Bought energy
self += '/Ac/Energy/Reverse', 'kWh', 5004 # Sold energy
self += '/Ac/Power', 'W', 5009 # Total apparent power
# self += '/Ac/PowerLimit', 'W' # writeable # TODO
self += '/StatusCode', ''
for phase in range (0,3):
p = phase + 1
self += f'/Ac/L{p}/Current', 'A AC', 5022+phase, 0.1
self += f'/Ac/L{p}/Energy/Forward', 'kWh'
self += f'/Ac/L{p}/Power', 'W'
self += f'/Ac/L{p}/Voltage', 'V AC', 5019+phase, 0.1
self.phase_energies = [0,0,0]
def _update(self, s):
interval_sec = self._interval_ms/1000.0
d = self.read(5083, n=5104-5083)
# Every second one is rubbish
d = d[::2]
s['/Ac/Power'] = roundu(d[0],1,'W') # W
log.debug('/Ac/Power %s', s['/Ac/Power'])
s['/Ac/Energy/Forward'] = roundu(d[8]*0.1,1,'kwHr') # Total import energy - kWh
s['/Ac/Energy/Reverse'] = roundu(d[6]*0.1,1,'kwHr') # total export energy - kWh
dvolts = self.read(5019, 6)
pd = d[1:] # phase data
for phase in range(3):
p = phase + 1
v = 0 # not supplied
i = 0 # not supplied
phase_power = pd[phase] # W
self.phase_energies[phase] += phase_power * interval_sec/3600.0/1000# kWh
s[f'/Ac/L{p}/Voltage'] = roundu(v, 1,'V')
s[f'/Ac/L{p}/Current'] = roundu(i, 1,'A')
s[f'/Ac/L{p}/Power'] = roundu(phase_power, 1,'W')
s[f'/Ac/L{p}/Energy/Forward'] = roundu(self.phase_energies[phase],1,'kwHr')
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
# === All code below is to simply run it from the commandline for debugging purposes ===
# It will created a dbus service called com.victronenergy.pvinverter.output.
# To try this on commandline, start this program in one terminal, and try these commands
# from another terminal:
# dbus com.victronenergy.pvinverter.output
# dbus com.victronenergy.pvinverter.output /Ac/Energy/Forward GetValue
# dbus com.victronenergy.pvinverter.output /Ac/Energy/Forward SetValue %20
#
# Above examples use this dbus client: http://code.google.com/p/dbus-tools/wiki/DBusCli
# See their manual to explain the % in %20
def main():
logging.basicConfig(level=logging.DEBUG)
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
client = ModbusTcpClient('192.168.20.23')
client.connect()
inverter = SungrowInverter(
client,
servicename='com.victronenergy.pvinverter.sungrow01',
deviceinstance=0,
)
meter = SungrowMeter(
client,
servicename='com.victronenergy.grid.sungrow01',
deviceinstance=0,
)
#o2 = SungrowInverter(
#servicename='com.victronenergy.dummyservice2.tty02',
# deviceinstance=1,
## paths={
# '/Ac/Energy/Forward': {'initial': 0, 'update': 1},
# '/Position': {'initial': 0, 'update': 0},
# '/Nonupdatingvalue/UseForTestingWritesForExample': {'initial': None},
# '/DbusInvalid': {'initial': None}
# })
logging.info('Connected to dbus, and switching over to GLib.MainLoop() (= event based)')
mainloop = GLib.MainLoop()
mainloop.run()
if __name__ == "__main__":
main()