From f4398c0a3595a525518b40799ded56d7bfe46da0 Mon Sep 17 00:00:00 2001 From: Markus Lippert Date: Thu, 11 Apr 2024 07:08:33 +0200 Subject: [PATCH] add script for Engelmann SensoStar E --- docs/Smart-Meter-Interface.md | 79 +++++++++++++++++++++++++++++++++++ 1 file changed, 79 insertions(+) diff --git a/docs/Smart-Meter-Interface.md b/docs/Smart-Meter-Interface.md index 98d428eaee..155f699aad 100644 --- a/docs/Smart-Meter-Interface.md +++ b/docs/Smart-Meter-Interface.md @@ -3839,3 +3839,82 @@ Tested on an AEConversion INV500-90 with RS485 interface. print request data finished # ``` + +### Engelmann SensoStar E (Heat meter, used with Hichi IR interface) + +??? summary "View script" + ``` + >D + wkup=1 + + >B + ;setup sensor + ->sensor53 d0 + ->sensor53 r + + >S + ; this device is powered by battery + ; frequent requests will lead to blocking and reduces lifetime + ; starting sequence: + ;- press button on device once + ;- restart Tasmota with script activated (you have 5 minutes to do this) + ;- after 30s data is retrieved and logged (including SYSLOG depending on Tasmota log config) + ;- now every 45min a new request is done, updated in WebUI (and transferred by MQTT every TPER period); polling period needs to be less 60min to avoid sleep mode of device! + + if ((upsecs==1) or (upsecs%2700==0)) { + print read meter + =#readmeter + } + + if upsecs==30 { + ->sensor53 d1 + print read meter (dump) + =#readmeter + } + + if upsecs==60 { + ; disable dump + ->sensor53 d0 + } + + + >M 1 + +1,3,rE1,0,2400,WAERME,1 + 1,=so3,32 + 1,0478u32s@1,Zählernummer,,Zählernummer,0 + 1,0406u32s@1000,Energie,MWh,Energie,3 + 1,0413u32s@1000,Volumen,m³,Volumen,3 + 1,042bu32s@1,Leistung,W,Leistung,0 + 1,142bu32s@1,Max. Leistung,W,Max. Leistung,0 + 1,043bu32s@1000,Volumenstrom,m³/h,Volumenstrom,3 + 1,143bu32s@1000,Max. Volumenstrom,m³/h,Max. Volumenstrom,3 + 1,025buuUU@1,Vorlauftemperatur,°C,Vorlauftemperatur,0 + 1,025fuuUU@1,Rücklauftemperatur,°C,Rücklauftemperatur,0 + 1,0261ssSS@100,Temperaturdifferenz,°C,Temperaturdifferenz,2 + 1,0223uuUU@1,Betriebsdauer,Tage,Betriebsdauer,0 + 1,4406u32s@1000,Stichtag Energie,MWh,Letzter Stichtag Energie,3 + 1,4413u32s@1000,Stichtag Volumen,m³,Letzter Stichtag Volumen,3 + # + + #readmeter + print wakeup start + ;set serial protocol + sml(-1 1 "2400:8N1") + ;send 0x55 for 2,2 seconds with 8N1 (53x), 2400 baud (wakeup sequence) + for wkup 1 53 1 + sml(1 1 "55555555555555555555") + next + print wakeup end + wkup=1 + print wait for the meter + delay(350) + ;switch serial protocol + sml(-1 1 "2400:8E1") + print init MBus (1040004016); scan for device 00 + sml(1 1 "1040004016") + delay(350) + print request current data (107BFE7916) + sml(1 1 "107BFE7916") + print request current data finished + # + ```