forked from vikt0rm/dbus-shelly-1pm-pvinverter
-
Notifications
You must be signed in to change notification settings - Fork 0
/
dbus-shelly-3em-pvinverter.py
executable file
·223 lines (172 loc) · 8.57 KB
/
dbus-shelly-3em-pvinverter.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
import platform
import logging
import sys
import os
import time
import requests
import configparser
if sys.version_info.major == 2:
import gobject
else:
from gi.repository import GLib as gobject
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
from vedbus import VeDbusService
class DbusShelly3emService:
def __init__(self, servicename, paths, productname='Shelly 3EM', connection='Shelly 3EM HTTP JSON service'):
config = self._getConfig()
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
customname = config['DEFAULT']['CustomName']
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
self._paths = paths
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unknown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductId', 0xFFFF)
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/CustomName', customname)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/Latency', None)
self._dbusservice.add_path('/FirmwareVersion', self._getShellyFWVersion())
self._dbusservice.add_path('/HardwareVersion', 0)
self._dbusservice.add_path('/Position', int(config['DEFAULT']['Position']))
self._dbusservice.add_path('/Serial', self._getShellySerial())
self._dbusservice.add_path('/UpdateIndex', 0)
# Add path values to dbus
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue)
# Last update
self._lastUpdate = 0
# Add _update function 'timer'
gobject.timeout_add(250, self._update) # pause 250ms before the next request
# Add _signOfLife 'timer' to get feedback in log every 5 minutes
gobject.timeout_add(self._getSignOfLifeInterval() * 60 * 1000, self._signOfLife)
def _getShellySerial(self):
meter_data = self._getShellyData()
if not meter_data['mac']:
raise ValueError("Response does not contain 'mac' attribute")
serial = meter_data['mac']
return serial
def _getShellyFWVersion(self):
meter_data = self._getShellyData()
if not meter_data['update']['old_version']:
raise ValueError("Response does not contain 'update/old_version' attribute")
ver = meter_data['update']['old_version']
return ver
def _getConfig(self):
config = configparser.ConfigParser()
config.read("%s/config.ini" % (os.path.dirname(os.path.realpath(__file__))))
return config
def _getSignOfLifeInterval(self):
config = self._getConfig()
value = config['DEFAULT']['SignOfLifeLog']
if not value:
value = 0
return int(value)
def _getShellyStatusUrl(self):
config = self._getConfig()
accessType = config['DEFAULT']['AccessType']
if accessType == 'OnPremise':
URL = "http://%s:%s@%s/status" % (config['ONPREMISE']['Username'], config['ONPREMISE']['Password'], config['ONPREMISE']['Host'])
URL = URL.replace(":@", "")
else:
raise ValueError("AccessType %s is not supported" % (config['DEFAULT']['AccessType']))
return URL
def _getShellyData(self):
URL = self._getShellyStatusUrl()
meter_r = requests.get(url=URL)
# Check for response
if not meter_r:
raise ConnectionError("No response from Shelly 3EM - %s" % (URL))
meter_data = meter_r.json()
# Check for JSON
if not meter_data:
raise ValueError("Converting response to JSON failed")
return meter_data
def _signOfLife(self):
logging.info("--- Start: sign of life ---")
logging.info("Last _update() call: %s" % (self._lastUpdate))
logging.info("Last '/Ac/Power': %s" % (self._dbusservice['/Ac/Power']))
logging.info("--- End: sign of life ---")
return True
def _update(self):
try:
# Get data from Shelly 3EM
meter_data = self._getShellyData()
# Send data to DBus
for i, phase in enumerate(['L1', 'L2', 'L3']):
pre = '/Ac/' + phase
emeter = meter_data['emeters'][i]
voltage = emeter['voltage']
current = emeter['current']
power = emeter['power']
total = emeter['total']
self._dbusservice[pre + '/Voltage'] = voltage
self._dbusservice[pre + '/Current'] = current
self._dbusservice[pre + '/Power'] = power
self._dbusservice[pre + '/Energy/Forward'] = total / 1000
self._dbusservice['/Ac/Power'] = meter_data['total_power']
self._dbusservice['/Ac/Energy/Forward'] = sum(emeter['total'] for emeter in meter_data['emeters']) / 1000
# Increment UpdateIndex - to show that new data is available
index = self._dbusservice['/UpdateIndex'] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice['/UpdateIndex'] = index
# Update lastupdate vars
self._lastUpdate = time.time()
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
# Return true, otherwise add_timeout will be removed from GObject
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
def main():
# Configure logging
logging.basicConfig(format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=logging.INFO,
handlers=[
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
logging.StreamHandler()
])
try:
logging.info("Start")
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
# Formatting
_kwh = lambda p, v: (str(round(v, 2)) + 'kWh')
_a = lambda p, v: (str(round(v, 1)) + 'A')
_w = lambda p, v: (str(round(v, 1)) + 'W')
_v = lambda p, v: (str(round(v, 1)) + 'V')
# Start our main-service
pvac_output = DbusShelly3emService(
servicename='com.victronenergy.pvinverter',
paths={
'/Ac/Energy/Forward': {'initial': None, 'textformat': _kwh}, # energy produced by pv inverter
'/Ac/Power': {'initial': 0, 'textformat': _w}, # power produced by pv inverter
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L1/Current': {'initial': 0, 'textformat': _a},
'/Ac/L2/Current': {'initial': 0, 'textformat': _a},
'/Ac/L3/Current': {'initial': 0, 'textformat': _a},
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
'/Ac/L1/Energy/Forward': {'initial': None, 'textformat': _kwh},
'/Ac/L2/Energy/Forward': {'initial': None, 'textformat': _kwh},
'/Ac/L3/Energy/Forward': {'initial': None, 'textformat': _kwh},
})
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
mainloop = gobject.MainLoop()
mainloop.run()
except Exception as e:
logging.critical('Error at %s', 'main', exc_info=e)
if __name__ == "__main__":
main()