Dell Unity
Metrics name | Type | Help |
---|---|---|
san_lun_number_read_io | gauge | LUN Read IOPS |
san_lun_number_write_io | gauge | LUN Write IOPS |
san_lun_read_kb | gauge | LUN Read Data Rate - KiB/s |
san_lun_write_kb | gauge | LUN Write Data Rate - KiB/s |
san_lun_response_time_ms | gauge | LUN Response Time - ms |
san_disk_number_read_io | gauge | Disk Read IOPS |
san_disk_number_write_io | gauge | Disk Write IOPS |
san_disk_read_kb | gauge | Disk Read Data Rate - KiB/s |
san_disk_write_kb | gauge | Disk Write Data Rate - KiB/s |
san_disk_response_time_ms | gauge | Disk Response Time - ms |
san_node_utilization | gauge | Total percentage of CPUs |
san_node_temperature | gauge | Node Temperature - degree Celcius |
SC 8000
Metrics name | Type | Help |
---|---|---|
san_controller_read_service_time_ms | gauge | Controller Read Response Time - ms/op |
san_controller_write_service_time_ms | gauge | Controller Write Response Time - ms/op |
san_controller_average_IOSize_kb | gauge | Controller Average Transfer Size - KiB/op |
san_controller_read_kb | gauge | Controller Read Data Rate - KiB/s |
san_controller_write_kb | gauge | Controller Write Data Rate - KiB/s |
san_controller_total_kb | gauge | Controller Total Data Rate - KiB/s |
san_controller_number_write_io | gauge | Controller Write I/O Rate - ops/s |
san_controller_number_read_io | gauge | Controller Read I/O Rate - ops/s |
san_controller_number_total_io | gauge | Controller Total I/O Rate - ops/s |
san_cpu_percent_usage | gauge | Controller The percent usage of the CPU |
san_memory_percent_usage | gauge | Controller The percent usage of the CPU |
san_volume_read_service_time_ms | gauge | Volume Read Response Time - ms/op |
san_volume_write_service_time_ms | gauge | Volume Write Response Time - ms/op |
san_volume_average_IOSize_kb | gauge | Volume Average Transfer Size - KiB/op |
san_volume_read_kb | gauge | Volume Read Data Rate - KiB/s |
san_volume_write_kb | gauge | Volume Write Data Rate - KiB/s |
san_volume_total_kb | gauge | Volume Total Data Rate - KiB/s |
san_volume_number_write_io | gauge | Volume Write I/O Rate - ops/s |
san_volume_number_read_io | gauge | Volume Read I/O Rate - ops/s |
san_volume_number_total_io | gauge | Volume Total I/O Rate - ops/s |
san_alert | gauge | SAN alert |
san_sc_total_capacity_mib | gauge | Total capacity of SC in MiB |
san_sc_use_capacity_mib | gauge | Use of SC in MiB |
san_sc_free_capacity_mib | gauge | Free of SC in MiB |
san_sc_server | gauge | Info servers for the Storage Center |
san_sc_info | gauge | SC information by DSM managed |
san_port_sc | gauge | Info port in SC |
san_controller_availableMemoryMib | gauge | Info and availableMemory in Mib of controller |
HP MSA
Metrics name | Type | Help |
---|---|---|
san_node_iops | gauge | The number of input/output operations per second in the node |
san_node_bps | gauge | Node throughput bytes per second |
san_pool_volumes | gauge | Number of volumes in the pool |
san_pool_bps | gauge | Pool throughput byte per second |
san_pool_iops | gauge | The number of input/output operations per second in the pool |
san_volume | gauge | Volume size |
Hitachi G700 (Through Ops Center)
Metrics name | Type | Help |
---|---|---|
san_port_total_io | gauge | Port total IO Rate - ops/s |
san_port_total_transfer | gauge | Port total Transfer Rate - kb/s |
san_pool_read_transfer | gauge | Pool read transfer rate - kb/s |
san_pool_write_transfer | gauge | Pool write transfer rate - kb /s |
san_pool_used_capacity_mib | gauge | Used capacity of pool in Mib |