#!/usr/bin/python -u
# -*- coding: utf-8 -*-
from startstop import StartStop
import logging
import dbus
import monotonic_time
from gen_utils import States, dummy
remoteprefix = 'com.victronenergy.system'
name = "Generator0"
device_instance = 0
# List of the service/paths we need to monitor
monitoring = {
'com.victronenergy.settings': {
'/Settings/Relay/Function': dummy,
'/Settings/Relay/Polarity': dummy,
},
'com.victronenergy.system': {
'/Relay/0/State': dummy,
'/DeviceInstance': dummy,
}
}
# Determine if a startstop instance can be created for this device
def check_device(dbusmonitor, service):
# Built-in relay has not its own service so this check must always
# return false.
return False
def create(dbusmonitor, remoteservice, settings):
i = RelayGenerator(device_instance)
i.set_sources(dbusmonitor, settings, name, remoteservice)
return i
class RelayGenerator(StartStop):
_driver = 0 # Relay
_digitalInput = 0
def _remote_setup(self):
self.enable()
# Make sure that the relay polarity is set to normally open.
if self._dbusmonitor.get_value('com.victronenergy.settings', '/Settings/Relay/Polarity') == 1:
self._dbusmonitor.set_value('com.victronenergy.settings', '/Settings/Relay/Polarity', 0)
def _running_by_digital_input(self, path, value):
if path == '/DigitalInput/Running':
if value == 1: # Running
super()._generator_started()
else: # Stopped
super()._generator_stopped()
elif path == '/DigitalInput/Input':
self._digitalInput = value
if value == 0:
# No longer using the digital input to update runtime. Sync running with the state of startstop.
if (not self._generator_running and self._dbusservice['/State'] in (States.RUNNING, States.WARMUP, States.COOLDOWN, States.STOPPING)):
super()._generator_started() # Digital input was "Stopped", but control service is running -> Start counting runtime.
elif (self._generator_running and self._dbusservice['/State'] not in (States.RUNNING, States.WARMUP, States.COOLDOWN, States.STOPPING)):
super()._generator_stopped() # Digital input was "Running" but control service is stopped -> Stop counting runtime.
logging.info('No longer using digital input to count runtime for startstop instance %d' % device_instance)
else:
logging.info('Using digital input %d to count runtime for startstop instance %d' % (value, device_instance))
# Sync runtime counting with the state of the digital input.
if self._dbusservice['/DigitalInput/Running'] == 1:
super()._generator_started()
else:
super()._generator_stopped()
return True
def remove(self):
# Open the relay before stop controlling it
self._set_remote_switch_state(0)
StartStop.remove(self)
def _check_remote_status(self):
# Nothing to check
pass
def _get_remote_switch_state(self):
return self._dbusmonitor.get_value(self._remoteservice, '/Relay/0/State')
def _set_remote_switch_state(self, value):
self._dbusmonitor.set_value_async(self._remoteservice, '/Relay/0/State', value)
# No digital input to monitor the generator, assume that it runs based on the state of the relay
if self._digitalInput == 0:
super()._generator_started() if value else super()._generator_stopped()