-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathabstract.tex
22 lines (12 loc) · 6.87 KB
/
abstract.tex
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
% % % In the realm of photoemission spectroscopy, the exploration of large multi-dimensional phase spaces necessitates time-intensive data acquisition to ensure statistical robustness. Despite the unparalleled capabilities of free-electron lasers (FELs), in peak brightness and ultra- short pulsed X-rays, the limitations of low repetition rates prolong the data acquisition process. This impedes the agility of decision making that could otherwise enhance experimental results in the limited and valuable beamtime. By employing denoising strategies to mitigate noise while preserving intrinsic information, our proposed approach aims to streamline the data acquisition process, and effectively manage the escalating size and complexity of multi-dimensional photoemission data.
% % We present a deep learning approach based on the Noise2Noise framework to denoise multidimensional photoemission spectroscopy (MPES) data obtained with a time-of-flight momentum microscope. Specifically, a 3D U-Net architecture is trained using low- and high-count noisy data, enabling the model to learn noise characteristics without requiring clean images. Our approach excels at reconstructing images even at extremely low count levels (order of 10^-3 counts/pixel), where conventional denoising techniques simply fail. Tests show that a 10-min acquisition processed with our deep learning model resolves major features not even visible after multiple hours of measurement. The presented approach has the potential to streamline the MPES data acquisition process at table-top/laboratory sources as well as large-scale facilities like FEL FLASH. By utilizing our method in future studies, researchers will be able to efficiently optimize acquisition parameters; thus, significant beamtime could be conserved, or an existing beamtime budget could be used more effectively, allowing for the exploration of a broader parameter space.
% In the realm of photoemission spectroscopy, the exploration of large multi-dimensional phase spaces necessitates time-intensive data acquisition to ensure statistical robustness. Despite the unparalleled capabilities of free-electron lasers (FELs), in peak brightness and ultra-short pulsed X-rays, the limitations of low repetition rates prolong the data acquisition process. This impedes the agility of decision making that could otherwise enhance experimental results in the limited and valuable beamtime. By employing denoising strategies to mitigate noise while preserving intrinsic information, our proposed approach aims to streamline the data acquisition process, and effectively manage the escalating size and complexity of multi-dimensional photoemission data.
% We present an investigation into advanced denoising methodologies for multidimensional photoemission spectroscopy (MPES) data acquired with time-of-flight momentum microscopes. Our study focuses on two key approaches: (1) classical denoising with BM3D combined with variance stabilization via the Anscombe transform and (2) a 3D deep learning approach, using the UNET architecture, based on the Noise2Noise paradigm.
% In addition, we analyze that photoemitted electrons acquired using SASE free-electron lasers (FEL) deviate from the commonly assumed Poissonian statistics and instead adhere to a negative binomial distribution, reflecting the overdispersion intrinsic to these systems.
% Despite the non-Poissonian statistics Anscombe-BM3D approach shows promising results in noisy images due to moderate counts (order of \num{1e-2} average counts/voxel). Whereas, our deep learning approach demonstrates exceptional performance, particularly in extreme low-count regimes (order of \num{1e-3} average counts/voxel), where conventional denoising techniques fail. Remarkably, we show that MPES datasets from a 10-minute acquisition processed with our trained model can reveal major features that are unobserved even after hours of measurement.
% These methodologies have hence the potential to streamline data acquisition at both laboratory-scale table-top setups and large-scale facilities like FEL FLASH. By optimizing acquisition parameters, researchers can conserve valuable beamtime or extend the scope of their studies to broader parameter spaces, results that hold broader implications for related experimental techniques.
The probabilistic nature of photoemission, combined with the exploration of large multidimensional parameter spaces--including momentum, energy, time and spin polarization--necessitates time-intensive data acquisition to ensure statistical robustness. These measurements are especially important for capturing ultrafast phenomena, where pulsed light sources, such as free-electron lasers (FELs), become indispensable due to their ability to deliver high-brightness, ultrashort X-ray pulses. However, the low repetition rates of current FEL sources significantly extend acquisition times, impeding the real-time decision-making that could otherwise enhance experimental results. Hence, to optimize experimental outcomes for the valuable beamtimes, techniques that can harness the structures and correlations within the multidimensional space are necessary to accelerate data acquisition without compromising data fidelity.
To address these challenges, we present an investigation into advanced denoising methodologies for multidimensional photoemission spectroscopy (MPES) data acquired with time-of-flight momentum microscopes. We focus on two key approaches: (1) employing BM3D with variance stabilization through the Anscombe transform in moderately noisy datasets and (2) leveraging a deep learning-based 3D UNET architecture, based on the Noise2Noise paradigm, excelling in low-count regimes where classical methods fail.
We further establish that the photoemitted electron distributions measured with SASE FELs deviate from traditional Poissonian statistics, instead following negative binomial statistics, an outcome that has implications for denoising strategies in the MPES data.
Our results demonstrate that BM3D delivers robust denoising performance for datasets with moderate average-counts (on the order of \num{1e-2} counts per voxel). However, in extreme low-count regimes (on the order of \num{1e-3} counts per voxel), where most conventional denoising techniques fail, the deep learning-based approach achieves exceptional denoising performance. Remarkably, we show that MPES datasets acquired in just \num{10} minutes using an FEL light source can, when processed with our deep learning model, reveal key features that remain indistinguishable even after hours of conventional measurement.
The findings presented have therefore the potential to streamline data acquisition at both laboratory-scale table-top setups and large-scale facilities such as FEL FLASH. By optimizing acquisition parameters, researchers can conserve valuable beamtime or extend the scope of their studies to broader parameter spaces, results that hold broader implications for related experimental techniques.