New features:

  • Stations identify themselves when reproducing recorded notification.
  • New labware configuration: wvr pcr plate configured in required protocols.

Protocol modifications:

  • Fixed m300 behaviour in C stations, as it was a mess dispensing mastermix in several wells with only one load.
  • Protocol B resusing tips now has an extra tiprack.
  • Protocol B does not stop automatically to let the user empty the trash anymore, now it has to be paused manually.

New release 1.10 18-Jun-2020

18 Jun 13:09
Compare
Choose a tag to compare

New features:

  • New labware configuration: Biotix tips for 300 and 1000 configured in all protocols.
  • New labware configuration: axygen pcr plate configured in required protocols.

Protocol modifications:

  • Waste disposal height modified, now the liquid waste is dispensed above the reservoir.
  • Aspiration in washes is modified from 220 to 210 ul to avoid the liquid touching the tip filters.
  • Change magnet height to 23 mm when using vwr deep well plates.
  • Removed reuse tips for elution steps in extraction protocol.
  • Now remove trash pause is prompted before the incubation pause.

Documentation:

  • Added calibration docs. Protocol, multichannel pipette and magdeck calibration.

New release 1.9 10-Jun-2020

10 Jun 11:18
Compare
Choose a tag to compare

Version 1.9

New features:

  • None

Protocol modifications:

  • Protocol B now aspirates larger volumes of supernatant and washes than dispensed, in order to remove residual volumes left due to pipetting error and drops attached to tips.

Bug fixes:

  • Fixed bug robot trying to send request when simulating

New release 1.8 01-Jun-2020

01 Jun 15:27
Compare
Choose a tag to compare

New features:

  • Reduced dispense speed when dispensing washes from the top of the wells to avoid spaying in protocol B.
  • Implemented reuse of tips for elutes in protocol B.
  • Added double definition of labware to fuse both reuse tips protocol B options in only one files.

Protocol modifications:

  • Increased supernatant removal to 810 ul to remove all of it in protocol B.
  • Removed reuse of first tip in washes in protocol B.
  • Protocol B labware layout has now two possible configurations, a legacy one for the old version of the protocol without tips reuse and the new optimised one.
  • Protocol C does not mix master mix any longer if not prepared in the machine to avoid creating bubbles.

Bug fixes:

  • Replaced default plate for biorad in protocol C.
  • Fixed tip tracking for the case where we have same p20 both multi-channel and single-channel in protocol C.
  • Fixed bug not transferring samples for exactly 8 samples with multi-channel in protocol C.
  • Fixed bug not changing trash for 48 samples exactly in protocol B.
  • Fixed bug added missing pick up tip for protocol C.
  • Fixed bug mm_tube not decalred in protocol C.

New release 1.7 29-09-2020

29 May 13:22
Compare
Choose a tag to compare

New features:

  • Added json sending using request. Requests python module is installed in all robots.
  • Automatic tests added using github actions for all protocols (except C station due to a bug in opentrons_simulate v.3.17.0 )
  • New protocol for using multi p20 pipette in station C for transferring extracts.
  • Now there are two pauses in B station for removing trash tips when > 48 samples. One after mix y another after remove_supernatant.
  • Added tip-reuse option for Station B protocol 1 (extraction).
  • Added labware definition for biotix tip rack 300 ul (needs testing).
  • Added labware definition for biotix tip rack 1000 ul (needs testing).
  • Added labware ecogen deepwell to protocols A (this was missing in last release).

Protocol modification:

  • For MM3 distribution in station C protocol 1 tip is changed every three columns.
  • Once mastermix is mixed in station C protocol 1 tip is changed.
  • Only one p20 rack tips in station C protocol 1 in slot 6.

Bug fixes:

  • Fixed unset variable in dispense_beads protocol 1 station B. 2ab984b

New release 1.6 22-May-2020

22 May 13:46
Compare
Choose a tag to compare

Hotfix:

  • Fix bug in hommogenize function in C protocol, used pip instead of
    p300.

New release 1.5 22-May-2020

22 May 11:21
Compare
Choose a tag to compare

Hotfix:

  • Removed comments where MAGNET_HEIGHT variable that were bothering
    opentronsweb

New release 1.4 20-May-2020

20 May 15:49
Compare
Choose a tag to compare

Version 1.4

Documentation:

  • Added user manual in spanish and english.
  • Added how to ethernet connect your robot.
  • Added how to calibrate.
  • Added ssh connection guide.

New features:

  • Voice messages language optional (spanish and english)
  • Added tip count reset option.
  • Added calibration scripts checking for all protocols.
  • Now beads dilution is optional in protocol 2 station A. b2b5444
  • Now volume_elute in station C is a parameter to be included by the user. 67f881f
  • Only pause for empty trash if samples > 48 in protocol B. 406c79a
  • Added json generation with run info in each protocol. This will be used for api connection with openrobots web.
  • New labware configuration for ecogen deep well, added to station A and B protocols.

Protocol modifications:

  • Now incubation time in protocol B is 7 minutes.
  • Reduced height in beads mix in protocol 2 station A, as it was taking some air sometimes. 53789ad
  • Increased height in beads mix in protocol 1 station B, as it was too close to the bottom.
  • Increased height in aspirates on on the plate above the magdeck, as it was sometimes touching the bottom.
  • Protocol now B starts with magdeck off. 6031d94
  • Fixed issue where m300 would go too deep and not aspire correctly in elution buffer. 40410be
  • Fixed issue where m300 would not aspirate correctly in all wells in supernatant removal, washes an elution when magnet is engaged. Aspiration height is increase to 1.5.

Bug fixes:

  • Fixed tip not dropping tip in p300 (protocol C) 9280ae8
  • Fixed correct pick up and drop tip for correct tip count for negative control (protocol C) 3483d15
  • Fixed correct drop tip for p300 (protocol C) 2e6cca7
  • Fixed tip count issue when only one pipette is used. 80b9567

New release 1.3 14-May-2020

14 May 15:00
Compare
Choose a tag to compare

Hotfix:

  • Fix bug in station C, save_tip_info() call missing. 46bc491

New release 1.2 12-May-2020

12 May 10:14
Compare
Choose a tag to compare

Hotfix:

  • Homogeneized imports sections across protocols
  • Added 'from os import subprocess' to support direct calls to subprocess()