B120 - Panna Version 2.6.0.0 (32/64 bit)

10 Sep 18:49
Compare
Choose a tag to compare

10 September 2019 Version 2.6.0.0

  • Fixed firmware parameters Create/Load
  • Allow position zero vial start for rinse
  • versioning now visible in title bar
  • tabbing bugs resolved
  • minor GUI tweaks (refresh ports button etc.)

AS120 - EST Version 2.6.0.0 (32/64 bit)

10 Sep 18:46
Compare
Choose a tag to compare

10 September 2019 Version 2.6.0.0

  • Fixed firmware parameters Create/Load
  • Allow position zero vial start for rinse
  • versioning now visible in title bar
  • tabbing bugs resolved
  • minor GUI tweaks (refresh ports button etc.)

Theus Software 1.4

21 Jul 21:20
Compare
Choose a tag to compare

Version 1.4 Theus Software installation CD

Release 1.3.2 Flex OS

03 Aug 17:01
Compare
Choose a tag to compare

Release Notes for Flex OS 1.3.2
Fixes
Add temperature range validation to the spme fiber condition routine.
Make sure status packets that come back that have errors are not processed. If the new firmware version fetch fails, fall back to the old way of asking each micro.
Convert all incremental moves to absolute moves (except on start up). This is to help a communication issue where multiple incremental moves are made when an ACK is not received and causes the instrument to time out because it got in a bad position.
Update the dialog shown to the user for the validation errors to be more human readable (less code looking).
Add volume validation to routines.
Can no longer select head accessories that are already configured(unless MFX/MTX is present).
Using npm works again, used vue-cli-typescript instead of manually installing typescript
Change confirmation code over to electron way (fixes input breaking after interacting with the confirmation dialog)
Update VialPicker to have a vertical numbering option to show vial positions correctly for chilled tray.
Increase default timeout for predicates to 300,000 millis (5 min)
Make the drive check while looking for the flex storage exception log entry less annoying (didn't need a stack trace)
Add the ability to change the injection movement speed into the GC. Add explicit option for fast inject (hides pre/post injection delay options).
Updating movement speeds for exchanging head tools to use calibration profile instead of operational.
Add a check on the location of the incubator during calibration so that it is placed far enough away from the edge of the rail to accommodate the SPME disengage movements.
Update default motion profiles for UD calibration and FR operations.
Updated effectiveSelectedTray method to take into account if the selectedTray has been updated.
Bug fix to get the correct accessory and vial picker graphic to display every time the accessory is changed. Also automatically corrects vial position to the max for the given accessory if a position of greater value was selected before.
Extra logging of Plan generated for a sequence and non-status packets sent and received from the device.
Adding dialog to control PWM motors (SMM mixer) on the diagnostics screen.
Adding single magnet mixer information to the diagnostics screen.
Add connection status to the packet manager so that it can minimize verbose logging if exceptions are generated from a potential instrument.
Add sync calls in a different code location.
Add home check for incubator movement to the "Home" button on the diagnostics screen.
Position check for incubator during calibration.
If a position fault is detected, the head assumes a vial is attached and attempts to put it back in its home position. Added a check when putting samples in the incubator to make sure the sample isn't already in the incubator.
Update gitattributes so linguist doesn't count vendored files.
Change setting so default Application configuration runs on Windows.
Add README with new build instructions.
Sync project settings to make it more cloneable.
Adds BetterRPC and BetterPlugins into the flex-core project, as well as migrate from maven to gradle.
Add scrollbars back in.
Adding new error handling and recovery for Position Fault (fault can be generated from DRV boards). Increased strip distance to 60 steps from 50.
Position faults recorded in the logs should have text instead of the fault number.
Add stop and home check to syringe fill routine and start of spme extraction.
Refactor code to use incubator stop method used in other parts of code as well as ensure that the correct position was reached.
Adding chilled tray. Updated computed tray class to allow for vial positions that are computed column-wise instead of row wise (both are possible now).
Implement auto increment feature for syringe fill routine.

FlexOS Release 1.3.1

22 May 12:24
Compare
Choose a tag to compare
FlexOS Release 1.3.1 Pre-release
Pre-release

FlexOS Release 1.3.1
This is an official release of FlexOS.
Fixes
Adjust fiber conditioner heater PID "P" value.
Increase queue size and averaging to 20 for temperature displays. This helps smooth out the reported temperatures.
Remove enabling then disabling the Helium valve in the SPME fiber condition routine.
Add extra logging information on movement errors.
Relax position conditions on movements.
Include building and running instructions.
Added large waste station(100mL) accessory.

1.0.18 Flex Suite Software Release

20 May 19:00
Compare
Choose a tag to compare

24 April 2019 Version 1.0.18 (Flex Suite Release)

  • Updated Bug Fix for Incubator Home Routine.
    • Reduced step off home switch to 50 steps from 100 steps
    • Remove the Safety Blinks during the Home Switch checks.

Change Log - Flex Suite 1.0.18

-https://github.com/ESTAnalytical/Flex/tree/1.0.18_Release
ESTAnalytical/Flex#647
ESTAnalytical/Flex@f80c9ef

Nexis and Athena software installables

26 May 14:45
Compare
Choose a tag to compare

Nexis software release

Nexis 2.18.97 is for new AS 120NG driver and large volume trays

LGX 2.3.03 Release

15 Oct 22:16
Compare
Choose a tag to compare

2.3.03 Release - 10/12/2020

Update stir motor speed 75 ohm resistor
high speed = PWM 16 7.7 vdc no load
med speed = PWM 12 5.6 vdc no load
low speed = PWM 10 4.6 vdc no load
backwards compatibility for stir motor with resistor set registry InstrumentStirType to "5"

LGX 2.3.02 Release

03 Apr 19:00
Compare
Choose a tag to compare

2.3.02 Release - 03/17/2020

Update stir motor speed to remove 350 ohm resistor.
high speed = 5 6.5 vdc no load
med speed = 4 5.4 vdc no load
low speed = 3 3.7 vdc no load
backwards compatibility for stir motor with resistor set registry InstrumentStirType to "5"

2.3.05 EV Release

03 Oct 16:40
Compare
Choose a tag to compare

10/12/2020 - Version 2.3.05

  • Updated Software for new Flow Board Z183FP004 - New Flow sensor
    MPX4250 0-36 psi operating range.
    Create Registry key for new flow board implementation.
    Registry Type = REG_DWORD = "FlowBoardType"
    Case "NoKey"
    MPXMultiplier = 22.656 Old Flow Board
    Case "0"
    MPXMultiplier = 22.656 Old Flow board
    Case "1"
    MPXMultiplier = 8.075 NEW Flow Board

  • Updated Standby mode to not check for gas flow fault.
    Resolves issues with Nitrogen usage and new Standby flow after Bake mode
    and Centurion Minimizer plus enabled.

  • Update SYS default for Flow CV output limit to 4000 to help with Nitrogen as purge gas.